Surge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online

Similar documents
Surge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online

Surge Protection. A complete offering of surge protection products for homes, businesses, schools and light commercial applications.

Protection for All Your Appliances and Electronics

Application Description. Telephone and Cable Accessories. Type CHSP Surge Protection

Presenter Information

CHSPMAX CHSP Max 120/240 Ac Power, 2500J

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

BSPD Surge Protective Devices

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

Table Residential Surge Products Product Catalog Number Price U.S.S Stage 1 CHSP Micro. CHSP 3-Way. CHSP Ultra

Eaton s SPD Series for integration into electrical distribution equipment

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Surg Sur e P ot r ection

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GUIDE TO VERIFYING SURGE PROTECTIVE DEVICES INSTALLED IN LIGHTNING PROTECTION SYSTEM INSTALLATIONS ARE COMPLIANT WITH UL 96A.

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Surge Protective Devices. STV100K Series. Instruction Manual

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protection Devices (SPD)

White Paper Surge Protective Devices in Automatic Transfer Switches

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Miniature Circuit Breakers and Supplementary Protectors. Contents

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

SECTION SURGE PROTECTIVE DEVICES

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Circuit Breakers NEED

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

60103 Circuit Breaker

Residential Renovation Loadcenters and Accessories

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Surge Protection (TVSS)

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

SECTION ( ) LIGHTING CONTROL PANELBOARD

Innovative Technology line filters and surge protectors

Internal Modular SPDs

R-LB R-LX Series Installation, Operation & Maintenance Manual

PDI Modular Compact Remote Power Panel

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

THE SURGE PROTECTION SOLUTION

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

Recp HG Ig SGL 20A 125V 2P3W STR B&S or

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR

GE Digital Energy. Power Quality

920 Remote Control (RC) Switches

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

Grid to Chip Surge Protection Product Catalog

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Powering innovation. Powering efficiency. Powering home

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

US CATALOG. SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential.

ASCO 920 Remote Control (RC) Switches

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Surge Protective Devices. STV25K Series. Instruction Manual

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

The protection you rely on

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

B. System Design and Performance Requirements

TST SERIES. Din Rail Surge Protective Device for SCADA Systems. Meter-Treater, Inc. Dimensions. Product Specifications. Notes

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

BUSSMANN. North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES. Application note 3193

Instruction Manual IM E Table of Contents

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

SECTION SWITCHBOARDS

Square D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

TDX Series. Transient Discriminating TM TVSS

CLiP 4X 24VAC EXTERIOR IP67 LINEAR LED ACCENT LIGHTING, LOW-POWER

Applying branch circuit breakers and supplementary protectors in North America

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

Transcription:

Surge Protection Surge Protection Devices.1 Product Description....................................... Application Description.................................... Standards and Certifications................................ Product Selection......................................... Learn Online V1-T- V1-T- V1-T-3 V1-T-4 Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com V1-T-1

Revision notes Volume 1 Residential and Light Commercial, CA0810000E Tab Surge Protection Revision date Section Change page(s) Description 0/19/018 All All Change to revision date to match print version, February 018

.1 Surge Protection Surge Protection Devices Contents Description Standards and Certifications............... Product Selection....................... Page V1-T-3 V1-T-4 Product Description Due to the evolution of electronics and microprocessors in the home, there is a continuous challenge to provide quality (clean) power for electronic loads such as appliances, computers/home office and entertainment systems. Surges caused by lightning, utility grid switching and other sources travel on current carrying conductors throughout the home, which can affect and destroy sensitive electronic loads. Eaton offers a comprehensive family of surge products for use at service entrances. These products can help protect sensitive electronics against the damaging effects of surges. Application Description Two-Stage Protection Two stages of surge suppression are recommended to provide the best protection for electronic equipment. Two-stage surge suppression should be provided for all cables entering a home, including power, Internet and coaxial. Service Entrance Surge Protection Eaton s service entrance surge protection units provide premier surge protection for AC power at the service entrance. These products provide protection for residential electrical equipment by reducing power surges to an acceptable level for surge strips to handle at the point of use. UL 1449 3rd Edition Type 1 and Type Surge Protection Type 1 Surge Protective Device (SPD) Permanently connected Type 1 SPDs are intended for installation between the secondary of the service transformer and the line side of the service equipment overcurrent device, as well as the load side, including watt-hour meter socket enclosures, and are intended to be installed without an external overcurrent protective device. Type 1 devices are dual-rated for Type applications as well, providing the highest ratings available for installation at the service entrance Eaton s CHSPT1 products provide Type 1 surge protection in accordance with UL 1449 3rd Edition. These units can be universally mounted outside any manufacturer s primary service equipment Type Surge Protective Device Permanently connected Type SPDs are intended for installation on the load side of the service equipment overcurrent device, including SPDs located at the branch panel CHSPT products provide Type surge protection in accordance with UL 1449 3rd Edition. These units can be mounted outside of any manufacturer s loadcenter or inside an Eaton Surge/Surge Ready loadcenter. Eaton also offers accessories to the CHSPT line for cable protection Factory-Installed Surge Protection Eaton s loadcenters with factoryinstalled surge protection include a CHSPTULTRA and a two-pole 50 A circuit breaker. These loadcenters increase the effectiveness of surge protection due to reduced lead length. A modified deadfront allows for easy viewing of indicating lights for status indication Surge Panel Surge Ready Loadcenter The Surge Ready loadcenter provides a mounting provision for the CHSPTULTRA. This loadcenter has a modified deadfront to allow for viewing of indicating lights V1-T- Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com

Surge Protection.1 Two-Stage Protection 1 CHSP installed at the service entrance panel. SurgeTrap surge traps and strips located where sensitive electronics are plugged in. Plug-On Surge Protection Type CHSA For use on single-phase 10/40 Vac systems. The CHSA easily plugs into a single-phase Type CH loadcenter and occupies two 3/4-inch (19.1 mm) pole spaces, similar to a two-pole Type CH breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHSA LED visual indicators will signal the need for a replacement. This device is suitable for service entry locations when installed in accordance with NEC guidelines Type CLSURGE For use on single-phase 10/40 Vac systems. CLSURGE easily plugs into a singlephase Type BR loadcenter and occupies two 1-inch (5.4 mm) pole spaces similar to a two-pole Type BR breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the CLSURGE LED visual indicators will signal the need for replacement. This device is suitable for service entry locations when installed in accordance with NEC guidelines. This unit is also classified by UL for use in select GE, ITE/Siemens and Crouse-Hinds panels Type BRSURGE For use on single-phase 10/40 Vac systems. This easily plugs into a singlephase Type BR loadcenter and occupies two 1-inch (5.4 mm) pole spaces similar to a two-pole Type BR breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the BRSURGE LED visual indicators will signal the need for replacement. This device is suitable for service entry locations when installed in accordance with NEC guidelines Type CHQSA For use on single-phase, 10/40 Vac systems. This unit easily plugs into a Square D single-phase loadcenter Type QO and occupies two 3/4-inch (19.1 mm) pole spaces similar to a two-pole Type QO breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHQSA LED visual indicators will signal the need for a replacement. This device is suitable for service entrance locations installed in accordance with NEC guidelines. This device is UL classified to be used in place of Square D Type QO surge arresters (refer to Pub-3974) Type BRSURGECSA For use on single-phase 10/40 Vac systems. This easily plugs into a singlephase Type BR loadcenter and occupies two 1-inch (5.4 mm) pole spaces similar to a two-pole Type BR breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the BRSURGECSA LED visual indicators will signal the need for replacement. This device is suitable for service entry locations when installed in accordance with Canadian Electrical Code. This device is CSA listed to be used in a Type BR loadcenter Type 3 Point-of-Use Surge Protection Point-of-use surge protectors such as surge receptacles are installed within 30 ft of conductor length from the service panel and are designed to offer premium surge protection for specific electronics while providing innovative features to enhance user convenience. Standards and Certifications CHSPT1 Products: UL 1449 3rd Edition Type 1 CHSPT Products: UL/cUL 1449 3rd Edition Type CHSPCABLE: UL 6500, cul NEMA 3R Enclosure for CHSPCABLE: UL 50 Enclosure BRSURGE, CHSA, BRSURGECSA, CHQSA, CLSURGE: UL 1449 3rd Edition plug-in type; Type SPD Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com V1-T-3

.1 Surge Protection Product Selection CHSPT1ULTRA CHSPT1MAX CHSPT1MICRO CHSPT1-08Y SP1DINRAILKIT SPD Type 1 CHSP Service Entrance Surge Protection UL 1449 3rd Edition Product Features Commercial grade AC power protection Type 1 surge device for installation before or after the main service disconnect Convenient mounting options universal fit to any manufacturer s equipment Clear, visible LED indication displaying status of the surge protector Number Connection Enclosure Voltage Phase CHSPT1ULTRA CHSPT1MAX CHSPT1MICRO CHSPT1-08Y Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. Permanently connected device installed before or after the service disconnect overcurrent device. 100/00 Vac, 110/0 Vac, 10/40 Vac 100/00 Vac, 110/0 Vac, 10/40 Vac 100/00 Vac, 110/0 Vac, 10/40 Vac NEMA 4 10/08 Vac Threephase wye Accessory for Type 1 CHSP Service Entrance Surge Protection Number Description SP1DINRAILKIT Mounting kit for wall or DIN rail installation. 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I n : Nominal Discharge Current is the current that the device can withstand for 15 impulses. 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one time surge current rating per phase. For warranty details, go to www.eaton.com/surgetrap. Frequency (Hz) MCOV 1 VPR I 3 n SCCR 4 Single 50/60, 150 V L N Single 50/60, 150 V L N Single 50/60, 150 V L N 50/60, 150 V L N, 600 V L N, 600 V L N, 600 V L N, 600 V L N 0 ka 00 ka 50 ka 0 ka 00 ka 45 ka 0 ka 00 ka 36 ka 0 ka 00 ka 50 ka Surge Current Capacity, Per Phase Rating 5 V1-T-4 Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com

Surge Protection.1 CHSPTULTRA CHSPTSURGE SPD Type CHSP Service Entrance Surge Protection UL 1449 3rd Edition; cul Product Features AC power protection Universally connects to any manufacturer s loadcenter (breaker box) Quick connect design easy to mount cable protection modules LED status indication Number Connection Enclosure Voltage Phase CHSPTULTRA CHSPTSURGE Can be attached to the outside of any manufacturer s loadcenter (breaker box). This product should be connected on the load side of the loadcenter main service disconnect through a dedicated circuit breaker (follow NEC Guidelines). Can be attached to the outside of any manufacturer s loadcenter (breaker box). This product should be connected on the load side of the loadcenter main service disconnect through a dedicated circuit breaker (follow NEC Guidelines). NEMA 4 10/40 Single 60 150 V L N, Vac rated line voltage NEMA 4 10/40 Single 60 150 V L N, Vac rated line voltage 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I n : Nominal Discharge Current is the current that the device can withstand for 15 impulses. 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one time surge current rating per phase. 6 When used with a 50 A two-pole circuit breaker, 10 ka when used with a 15 A two-pole circuit breaker. For warranty details, go to www.eaton.com/surgetrap. Surge Current Frequency (Hz) MCOV 1 VPR I 3 n Capacity, Per SCCR 4 Phase Rating 5, 800 V N G, 600 V L G, 800 V N G, 600 V L G 0 ka 6 ka 108 ka (L1 N 54 ka, L1 G 54 ka, L-N 54 ka, L G 54 ka) 5 ka ka 36 ka (L1 N 18 ka, L1 G 18 ka, L N 18 ka, L G 18 ka) Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com V1-T-5

.1 Surge Protection CHSPCABLE Accessories for CHSP Type Service Entrance Protection Number Description Installation CHSPCABLE Quick Connect design add additional telephone and AC protection modules; protects two quad shield cables; bi-directional Indoor installation; or rain-tight when used with recommended enclosure Surge Current Capacity 10 ka per line 145 V DC Breakdown Voltage Voltage CHSPTPACK CHSPTPACK -Pack: CHSPTULTRA + CHSPCABLE; Surge protection for AC power and cable see individual product features See individual product ratings CHSP3RTELCABLE CHSP3RTELCABLE Raintight enclosure for CHSPTELE and CHSPCABLE; top or bottom feed; enclosure only, surge not included; accommodates up to two devices CHSPFMKIT CHSPFMKIT Flushmount kit for: CHSPTULTRA, CHSPTMAX, CHSPTSURGE, CHSPCABLE MSEGR MSEGR Outdoor communication grounding device; meets 008 NEC requirements for intersystem bonding termination Note For warranty details, go to www.eaton.com/surgetrap. V1-T-6 Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com

Surge Protection.1 Type BR and CH Surge Breakers Product Description The CH and BR surge breaker is designed to provide premier AC power surge protection for sensitive electronics and appliances from the damaging effects of electrical surges. In addition, the surge breaker is a functional two-pole thermal magnetic breaker. The combination of circuit protection and surge protection provides extra flexibility and space saving in the loadcenter. Type CH Surge Breakers Type BR Surge Breakers Number 1 Poles Type CH Surge Breakers CH30SUR Two-pole 10 kaic Product Features Complete home surge protection for all circuits plus a functional two-pole thermal magnetic breaker LEDs provide protection status Plug-on connection to the busbar provides superior protection and easy installation for new construction or renovation Eliminates the potential for incorrect installation of externally mounted surge devices (longer lead lengths can reduce protection levels) Ampere Rating Voltage Phase 30 10/40 Vac Single 50/60 150 V L N, CH50SUR 50 10/40 Vac Single 50/60 150 V L N, Type BR Surge Breakers BR30SUR Two-pole 10 kaic 30 10/40 Vac Single 50/60 150 V L N, BR50SUR 50 10/40 Vac Single 50/60 150 V L N, 1 Clamshell packaging available with CS modification code on the end of catalog number. MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 3 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 4 I n : Nominal Discharge Current is the current that the device can withstand for 15 impulses. 5 SCCR: The amount of current the product can withstand under short-circuit conditions. 6 Surge Current Capacity: The maximum one time surge current rating per phase. Frequency (Hz) MCOV VPR 3 I 4 n SCCR 5 Surge Current Capacity, Per Phase Rating 6 10 ka 10 ka 36 ka (L1 N 36 ka, L N 36 ka) 10 ka 10 ka 36 ka (L1 N 36 ka, L N 36 ka) 10 ka 10 ka 36 ka (L1 N 36 ka, L N 36 ka) 10 ka 10 ka 36 ka (L1 N 36 ka, L N 36 ka) Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com V1-T-7

.1 Surge Protection Surge Protection Receptacles with LED Indicators and Audible Alarm Product Description Two-pole, three-wire grounding 15 A, 15 Vac; 0 A, 15 Vac; NEMA 5-15R and 5-0R 536_S IG5350_S IG108 109 35MS Number Color Suffix For ordering devices, include catalog number followed by the color suffix: BL (Blue), GY (Gray), RD (Red), RN (Orange), V (Ivory), W (White) (Blue) (Gray) (Red) (Orange) (Ivory) (White) Compliances, specifications and availability are subject to change without notice. ArrowLink option available. Add M suffix to standard catalog number (example 8300WS, 8300WSM). Build-to-spec customizable devices. Ampere Rating Voltage NEMA Description Receptacles with Audible Alarm and LED Indicators, Back and Side Wire 56 S BL, GY, V, W 15 15 Vac 5-15R Surge duplex receptacle IG56 S BL, GY, RN, V, W IG Surge duplex receptacle 536 S BL, GY, V, W 0 15 Vac 5-0R Surge duplex receptacle IG536 S BL, GY, RN, V, W IG Surge duplex receptacle 560 Joules, max. surge current 18 ka per mode Receptacles with LED Indicators, Back and Side Wire 550 S BL, GY, V, W 15 15 Vac 5-15R Surge duplex receptacle IG550 S BL, GY, RN, V, W IG Surge duplex receptacle 5350 S BL, GY, V, W 0 15 Vac 5-0R Surge duplex receptacle IG5350 S BL, GY, RN, V, W IG Surge duplex receptacle 840 Joules, max. surge current 18 ka per mode Receptacles with Audible Alarm 108 V, W 15 15 Vac 5-15R Surge duplex receptacle IG108 V, W IG Surge duplex receptacle 110 BL, V, W 0 15 vac 5-0R Surge duplex receptacle IG110 V, W IG Surge duplex receptacle 340 Joules, max. surge current 1 ka per mode Number Color Suffix Ampere Rating Voltage Description Multimedia Wallplates with Surge Protectors 35MS- W 15 15 Multimedia wallplate with recessed duplex surge receptacle cetlus listed to UL1863 & ANSI/UL 60950-1, CSA C. no. 60950-1-03; complies with all TIA/EIA 568-A & 570-B requirements Number Color Suffix Description Replacement Surge Bloc Module 109 A, BL, GY, V, W Replacement module Number Color Suffix Description Accessories for Surge Protection Receptacles PJ6BL BL 1-Gang mid-size decorator polycarbonate wallplate PJ6W W 1-Gang mid-size decorator polycarbonate wallplate PJ6IG RN 1-Gang mid-size decorator polycarbonate wallplate, pre-marked ISOLATED GROUND BL GY RD RN V W V1-T-8 Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com

Surge Protection.1 Factory-Installed Surge Protection Includes a CHSPTULTRA and a two-pole 50 A circuit breaker Increases the effectiveness of surge protection due to reduced lead length Surge Installed Surge Ready Loadcenters Provides a mounting provision for CHSPTULTRA A modified deadfront allows for easy viewing of indicating lights Surge Ready A modified deadfront allows for easy viewing of indicating lights for status indication Surge Installed Loadcenters Cover Number Number Description Combination Surface CHSUR4N5L 1 4 ckt, 5 A, convertible CHSUR8LF CHSUR8LS CHSUR4L5L 1 4 ckt, 5 A, convertible CHSUR8LF CHSUR8LS CHSUR4B00L 1 4 ckt, 00 A, main breaker CHSUR8LF CHSUR8LS CHSUR3N5K 1 3 ckt, 5 A, convertible CHSUR8KF CHSUR8KS CHSUR3L5K 1 3 ckt, 5 A, convertible CHSUR8KF CHSUR8KS CHSUR3B00K 1 3 ckt, 00 A, main breaker CHSUR8KF CHSUR8KS CHSUR3B150K 1 3 ckt, 150 A, main breaker CHSUR8KF CHSUR8KS CHSUR3B100K 1 3 ckt, 100 A, main breaker CHSUR8KF CHSUR8KS CHSUR4L15E 1 4 ckt, 15 A, convertible CHSUR8EF CHSUR8ES CHSUR4B100E 1 4 ckt, 100 A, main breaker CHSUR8EF CHSUR8ES BRSUR4040N00 40/40 ckt, 00 A, convertible Cover included BRSUR4040L00 40/40 ckt, 00 A, main lug Cover included BRSUR4040B00 40/40 ckt, 00 A, main breaker Cover included BRSUR3040N00 30/40 ckt, 00 A, convertible Cover included BRSUR3040L00 30/40 ckt, 00 A, main lug Cover included BRSUR3040B00 30/40 ckt, 00 A, main breaker Cover included Surge Ready Loadcenters (Provision Only, CHSPTULTRA and Breaker Not Included) Cover Number Number Description Combination Surface CHEC4N5L 1 4 ckt, 5 A, convertible CHSUR8LF CHSUR8LS CHEC4L5L 1 4 ckt, 5 A, convertible CHSUR8LF CHSUR8LS CHEC4B00L 1 4 ckt, 00 A, main breaker CHSUR8LF CHSUR8LS CHEC3L5K 1 3 ckt, 5 A, convertible CHSUR8KF CHSUR8KS CHEC3N5K 1 3 ckt, 5 A, convertible CHSUR8KF CHSUR8KS CHEC3B00K 1 3 ckt, 00 A, main breaker CHSUR8KF CHSUR8KS CHEC3B150K 1 3 ckt, 150 A, main breaker CHSUR8KF CHSUR8KS CHEC3B100K 1 3 ckt, 100 A, main breaker CHSUR8KF CHSUR8KS CHEC4L15E 1 4 ckt, 15 A, convertible CHSUR8EF CHSUR8ES CHEC4B100E 1 4 ckt, 100 A, main breaker CHSUR8EF CHSUR8ES 1 Order cover separately. With main lugs installed. Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com V1-T-9

.1 Surge Protection BRSURGE CLSURGE CHSA BRSURGECSA CHQSA SPD Type Plug-On Surge Protection UL 1449 3rd Edition Product Features Convenient surge protection for the loadcenter Number Description Connection Voltage Phase BRSURGE CLSURGE CHSA UL for use in a single-phase Type BR loadcenter. This unit is classified by UL for use in select GE, ITE/Siemens and Crouse- Hinds panels (refer to Pub. No. 5655B65H01 for additional details). UL and CSA for use in a Type CH loadcenter. BRSURGECSA CSA for use in an Eaton Type BR loadcenter. CHQSA This device is UL classified to be used in place of Square D Type QO surge arresters (refer to Pub-3974). Plug on to the 10/40 loadcenter bus; Vac see instructions. Plug on to the 10/40 loadcenter bus; Vac see instructions. Plug on to the 10/40 loadcenter bus; Vac see instructions. Plug on to the 10/40 loadcenter bus; Vac see instructions. Plug on to the 10/40 loadcenter bus; Vac see instructions. 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I n : Nominal Discharge Current is the current that the device can withstand for 15 impulses. 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one-time surge current rating per phase. For warranty details, go to www.eaton.com/surgetrap. Surge Current Frequency (Hz) MCOV 1 VPR I 3 n Capacity, Per SCCR 4 Phase Rating 5 Single 60 150 V L1 N, Single 60 150 V L1 N, Single 60 150 V L1 N, Single 60 150 V L1 N, Single 60 150 V L1 N, 600 V L1 N, 600 V L1 N, 600 V L1 N, 600 V L1 N, 600 V L1 N, 3 ka 10 ka 18 ka 3 ka 10 ka 18 ka 3 ka 10 ka 18 ka 3 ka 10 ka 18 ka 3 ka 10 ka 18 ka V1-T-10 Volume 1 Residential and Light Commercial CA0810000E February 018 www.eaton.com