Installation and User Manual

Similar documents
Single Door Standalone Access Control User Manual

Waterproof. Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

DG-800 Stand-Alone Proximity Reader Instruction Manual

W3-H Waterproof Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

W3-M. Metal waterproof standalone access control/reader. User Manual

CM-110SK Standalone Keypad Installation Instructions

User Manual. PCKeypad Wireless Keypad

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

DOLXFD1000B. Waterproof Access Control/Reader

VIS-3200 / VIS-3201 User Manual

VIDI-AC-2CS Access Controller/ Reader

BC Digital Keypad. User Manual

Fingerprint Access Control F1. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Digital Keypad Introduction

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Stand-alone Proximity Access Control

User Manual. Split access control with intelligent secured power supply.

-DTZ001- Stand-Alone Proximity Access Control. User Manual

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

RBR-SB-KTZ001 LAR 2. User Manual

RFID/Digital Access Control Keypad

1. Product Specification

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Installing Keypad and Backplate

HSY-S209 EM Metal waterproof access control system User Manual

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Proximity Card and Pin Reader Installation Manual

EL-ST100 KEYPAD CONTROLLER

ACTsmart2 Product Range Operating and Installation Instructions

Metal Standalone Keypad Access Control S100

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CP150B Vandal & Weather Resistant Keypad Security Systems

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

AS Keypad User Manual

7612 Programming Instructions

IBA-7612 Programming Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

CC Series metal access control Manual

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

REX F-0-9 Standalone or Access Controller

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Specifications: Features:

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ONYX FINGERPRINT PASSWORD LOCK MANUAL

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Access Control Keypad

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

FTK5 PROXIMITY KEYPAD

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL


TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Access control panel U-Prox IC E (Elevator control)

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

The HAUSSMANN RIRI keypad

Two Door Controller GEN-045

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0

Set-up of ZK RFID Pin Pad

Documentation on all Paxton products can be found on our web site -

2000 Series e/em Style Keypad Installation and Programming Manual

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

DG Series. Access Control Proximity Readers DG-160 DG-800

CM-500 SK 500 USER CODES KEYPAD

USERS MANUAL.

Installers & User guide Smart Mortise.

MANUAL PIN CODE KEYPAD February 2013

Installers & User guide Smart Mortise.

GV-Card Reader. User s Manual

MS-5000: MiniStar Reader

Non-contact or proximity card access control using the manual

MS-7000: SuperStar Reader

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Installation & User Manual V1.0

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Index. Disable or Enable Code 06. Definition 02 Factory Default Settings 03 Important Notes 03 Change Master Code 03 Add Code 04

K44 Code lock. Technical manual

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

KP2000E/EM Series Style Keypad

Welcome Contents Diagram

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Transcription:

S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1

Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support 2500 users utilizing three access modes; Card only - Card plus PIN - Card or PIN S2 can operate in standalone mode, with its internal relay activating when an authorized user is granted access or can interface to 3 rd party products via its 26 Bit Wiegand output Installation Drill a hole in the wall to match the location of the cable at the rear of the S2 or mount a suitable wall mount junction box Thread the cable through cable hole and connect related cables. Take care to insulate the unused cables to prevent shorting Fix the back cover to the wall or distribution box with screws and secure the controller to the back casing Connection Diagram 2

Programming 0 - Resetting to Factory Defaults To reset to factory defaults, power off then press and hold the * key while powering up. S2 will beep twice and the LED will glow orange. Release the * key and the S2 will be ready for one of the following options: 1) Presenting the Add User Master Card to S2 s Reader to add a new user 2) Presenting the Delete User Master Card to delete a current user 3) Presenting a blank EM card to replace an Add User Master Card or Delete User Master Card. In this case the first blank card presented will become the new Add User Master Card and the second blank card presented will become the new Delete User Master Card. The LED will flash Red confirming that S2 has been reset to factory defaults and new Master Cards added. If the new Master Cards are not presented within 10 seconds S2 will resume User Operating Mode and the LED will glow steady Red When resetting to factory defaults the user's information is still retained 1 - Entering Programming Mode (Default Master Code = 888888) Press * then enter the Master Code followed by (e.g. * 888888 ) S2 will enter Program Mode, the LED will flash Green for one second and then glow steady Red while S2 awaits Program Option Commands. To Exit Program Mode press *. If no keys are pressed for 60 seconds S2 will automatically exit Program Mode and resume Operation Mode The following options can be accessed and programmed in Program Mode 2 - Changing the Master Code (Master Code must be 6 digits long) (Can only be done in Master Programming Mode) Press 0 - The LED will glow Orange. Enter a New Code followed by then re-enter the same New Code followed by. The LED will flash Green if successful Press 0 New Code Confirm New Code 3 - Adding Users (Can only be done in Master Programming Mode) Up to 2500 user cards can be added. The first two options are available in Program Mode only and the third is also available in Operation Mode 3.1 Adding Card Users Automatically in Program Mode (Not recommended) Press 1 - The LED will glow Orange. Present a blank card to the Reader. S2 will automatically assign the first card as User Card 1. When successful the LED will flash Green. Repeat this process for all new cards and then press Press 1 Present Card 1 Present Card 2 Present Card 3 This method is not recommended because S2 will automatically allocate added cards to the next available empty card slot. This makes it difficult to delete a card as its allocated card slot (ID number) will not be known 3

3.2 Adding Card Users Manually (Recommended method) Press 1 - The LED will glow Orange. Enter the ID Number (Memory slot number 1 -> 2500 of the card you wish to add) followed by. Present the new card to the Reader. When successful the LED will flash Green. If more cards are to be added repeat the process. Press to end Press 1 Enter ID No.1 Present Card 1 Enter ID No.2 Present Card 2 S2 will auto assign PIN 1234 (Factory Default) to programmed cards. If the system is set for Card AND PIN for access you must go to User Settings and assign an individual PIN to each card This is the recommended method of adding Card Users as the ID Number of all cards programmed will be known making it easy to select any individual card you may wish to delete 3.3 Adding PIN Only Users (No card) Press 1 - The LED will glow Orange. Enter the ID Number (Memory slot number 1 -> 2500 of the User) followed by. Enter a PIN for that User. When successfully added the LED will flash Green. Press to end. If more Users are to be added repeat the process for each User Press 1 Enter ID No.1 Enter PIN 1 Enter ID No. 2 Enter PIN 2... All PIN numbers must be 4 Digits of any number combination, however they must not be 1234 3.4 Adding Card Users Sequentially Multiple Users can be added sequentially as either a Card or Pin Press 1 Present Card 1 to the Reader Enter ID No.1 Present Card 2 to the Reader Enter ID No. 2 Enter PIN 3 Enter ID No. 3 3.5 Adding Users with the Add User Master Card User Cards can be added anytime without entering Program Mode by using the Add User Master Card that comes with the unit (or card that you have programmed) Present Add User Master Card to the Reader - The LED will glow Orange. Present the Card to be added. When successfully added the LED will flash Green. Present any additional cards to be added in sequence. When complete Present Add User Master Card again. The LED will flash Red Present Add User Master Card to the reader Present each Card to be added to the reader in sequence Present Add User Master Card to the reader to exit If the card being added is already in the system S2 will respond with 3 beeps 4

4 - Deleting Users (Can only be done in Master Programming Mode) 4.1 Deleting Users Automatically Press 2 -The LED will glow Orange. Present each Card to be Deleted to the reader in sequence. As each card is successfully deleted the LED will then flash Green. Press to exit Press 2 Present Card 1 to be deleted Present Card 2 to be deleted Present Card 3 to be deleted 4.2 Deleting Users Manually If the card to be deleted is lost or unavailable the ID Number of the User (Memory Slot the User is programmed into) must be used to identify the User Press 2 - The LED will glow Orange. Enter the ID number of the User to be deleted then press. When successfully deleted the LED will flash Green. Repeat this process for any more Users to be deleted Press 2 Enter ID Number of the User to be deleted Enter ID Number of the next User to be deleted 4.3 Deleting ALL users Press 2 - The LED will glow Orange. Press 0000 followed by the button. The LED will then flash Green confirming that all Users have been deleted Press 2 0000 4.4 Deleting Users using the Delete User Master Card Cards may be deleted anytime without entering Programming mode using the Delete User Master Card that comes with the S2 (or other programmed card) Present Delete User Master Card to the Reader - The LED will glow Orange. Present the Card to be Deleted. When successfully Deleted the LED will flash Green. Present any additional Cards to be Deleted in sequence. Present the Delete User Master Card to the reader again to complete. The LED will flash Red Present the Delete User Master Card to the Reader Present each Card to be added to the Reader in sequence Present the Delete User Master Card to the Reader If the card being deleted is not in the system the S2 will respond with 3 beeps 5

6 Door Access Control Settings (Can only be done in Master Programming Mode) Three programming options for Door Access Control are provided; Card Only, Card AND PIN or Card OR PIN 6.1 Grant Access by Card Only 6.2 Grant Access by Card AND PIN Press 30 Press 31 6.3 Grant Access by Card OR PIN Press 32 (Factory Default ) 7 Door Relay Time Setting (Unlock Time) > Default = 5 Seconds (Can only be done in Master Programming Mode) This option sets the activation time of the Relay when Access is granted by Card or PIN Press 4 Enter Activation time (0->99 Seconds) 8 Door Open Detection Settings (Can only be done in Master Programming Mode) These options are used to Enable / Disable the D_In (Door Switch Input). Press 60 Press 61 Disables the Door Open Detection Input (Factory Default) Enables the Door Open Detection Input When enabled: If the door is opened normally but not closed within 1 minute the buzzer will sound for 1 minute If the door is forced open (opened by an unauthorized user) the buzzer and alarm output will be activated 9 Security Mode Settings for Invalid Access Attempts (Can only be done in Master Programming Mode) Three options are provided for programming Keypad Lockout / Alarm Output in the event that multiple invalid Access attempts are made. Programming any option will override all previous settings Press 70 Normal Status (No Alarm Output or Keypad Lockout) (Factory Default) When enabled, the number of keypad entries is unrestricted (no Alarm Output or Keypad lockout regardless of the number of invalid code entries) Press 71 Keypad Lockout When enabled, the Keypad will lockout for 10 minutes if there are 10 successive invalid card presentations or 10 successive incorrect PIN numbers entered within a 10 minute period Press 72 Alarm Output 6

When enabled, the S2 Buzzer will sound and the Alarm Output will be activated if there are 10 successive invalid Card presentations or 10 successive incorrect PIN numbers entered within a 10 minute period 10 Site Code Setting (for Wiegand Output) (Can only be done in Master Programming Mode) When a valid User Code is entered the Wiegand Output will transmit the Site Code along with the 4 Digit PIN number entered as the Wiegand Card Number Example - If the PIN used is 8888 and the Site Code is 029 then the full 8 digit, 26 Bit Wiegand number transmitted on the Wiegand Output is 029 08888 The default Site Code is 029 however an alternative Site Code may be programmed Press 81 Enter Required Site Code (0->255) Site Code must be between 0 and 255 11 Setting the Address of the Reader (Default 0) (Can only be done in Master Programming Mode) When using S2 with security equipment that supports addressable readers such as Ness D8XD / 16XD Panels, Ness 6DA controllers etc it may be necessary to set the address of the reader When programmed to Address 0 (Default) the Wiegand Output uses standard 26 Bit Wiegand protocol. When set to address 1, 2 or 3 the Wiegand Output appends Ness encrypted protocols to S2 s address 0 - S2 Address 0 (Default) 1 - S2 Address 1 2 - S2 Address 2 3 - S2 Address 3 Press 82 Enter Address (0->3) (Factory Default is 0 - Standard 26 Bit Wiegand output) 12 Alarm Output Time (Default 1 Minute) (Can only be done in Master Programming Mode) This option sets the Alarm Output Time (duration) of S2 s Alarm Output Press 9 Enter Alarm Time in Minutes (1->3) (Factory Default is 1-1 Minute) 7

USER SETTINGS (User Settings can be programmed by the User at any time without entering Program Mode) Assigning a PIN to a CARD If the system is programmed for access is to be granted with Card and PIN (Programming Option 32 set) a PIN for each Card must be assigned using this option. (The Factory Default when cards are first programmed into the system is PIN 1234) Press * Present the Card to the Reader Enter Old PIN (Default 1234) Enter NEW PIN Repeat the NEW PIN Assigning a PIN to a ID Number This option also assigns a PIN to a Card, but if the card is unavailable you can assign it to the User s ID Number (Memory slot Number) Press * Enter the ID Number the PIN will be assigned to Enter Old PIN Enter New PIN Repeat the NEW PIN OPERATION Unlocking the Door By Card OR PIN. If the Door Access Control Setting (Section 6) is programmed to Card or PIN, access will be granted by presenting a valid Card to the Reader or by entering a valid PIN Either Present Card to Reader OR Enter 4 Digit PIN followed by If successful, the LED will flash Green and the Relay will activate for the Unlock time If unsuccessful, the S2 will sound 3 Beeps and the likely cause will be a non valid Card (unprogrammed or incorrectly programmed) or incorrect PIN entry (refer to Programming Section 3, Adding Users ) If a Card is presented and the LED glows steady S2 is waiting for a PIN to be entered. If this is not intended refer to Programming Section 6 Door Access Control Settings and select the correct Access Setting 8

Unlocking the Door By Card AND PIN If Door Access Control is set to Card (Section 6), access will be granted by presenting a valid Card to the Reader. The LED will glow RED upon the presentation of the valid Card in readiness for a PIN entry within 5 seconds. If the Card and PIN combination are both valid the LED will flash Green for the unlock time and the Relay will activate for the unlock period. If no PIN is entered within 5 seconds S2 will time out and the LED will return to its normal red Flashing mode. Present Card to Reader AND Enter 4 Digit PIN followed by S2 will sound 3 beeps if the entered PIN is invalid or incorrect Resetting / Restoring an Alarm If an Alarm occurs for any reason e.g. Door Forced Open or Open Too Long it can be reset by presenting A valid card to the Reader or by entering the Master Code Present a Valid Card to Reader OR Enter Master Code followed by Indicators / Warnings (LED and Buzzer) 9

Specifications Features Appearance Waterproof Description Metal case, anti-explosion and anti-tamper IP65 Input voltage DC: 12-24V AC: 12-18V Users(max) 2500 PIN Master Card Proximity Reader (RFID) Connect External reader Connect High Power Alarm Dimensions 4 digits Add/Delete User Supports Wiegand 26bits, PIN/Wiegand output is a virtual number, Site Code / Reader Address is set within the S2 Controller Can Connect any External EM/HID/IC readers with Wiegand 26 bit Output External Current of the Alarm <=3A 135mm x 57mm x 25mm Operating Voltage DC:12~24V AC: 12~18V Current Card Reading Distance Operating Temperature Lock Output Load Idle 35mA / Active <80mA 3~6 cm -40~60 Deg C 2A Max Head Office: 4/167 Prospect Hwy, Seven Hills NSW, Australia Phone +61 2 8825 9222 email : ness@ness.com.au Sydney Office - (02) 8825 9222 Melbourne Office -(03) 9875 6400 Brisbane Office - (07) 3399 4910 Perth Office -(08) 9328 2511 Adelaide Office - (08) 8152 0000 Email customerservice@ness.com.au 10