LCI User Manual mantracourt.com

Similar documents
LCI Load Cell Junction Box with Fault Monitor

DS485DIS Digital Strain RS458 Display Module

DSCUSB Standard User Manual. mantracourt.com DSCUSB. Digital Sensor Card USB Strain Gauge Input

LCT-1 User manual_v1_2017_03_30. LCT-1 Ultimate. Load Cell Tester Issue: Revision A User s Guide

FSU User Manual. mantracourt.com FSU-SSB. Fast Strain USB Strain Gauge Input

PSD Strain Gauge or Load Cell Hand Held Display TEDS enabled

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

PRODUCT SPECIFICATION. PC Board Relays. Series.

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

CA-A480-A Elevator Controller. Reference & Installation Manual

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Series 8000 RF Signal Switch Solution

Operating Manual RISH DPM Hz

Mini Digital Multimeter

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Power Meter PowerMonitor 500

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

User's Guide. Extech AM A AC Analog Clamp Meter

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

User's Manual Sound Level Alert Model SL130

ICA S & H Strain Gauge or Load Cell Embedded Analogue Amplifier. User Benefits. Ideal Applications

MTP INSTRUCTION MANUAL

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

ACLD Channel Opto-isolated Digital Input Board

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Series 8000 RF Signal Switch Solution

Tempco Instruction Manual

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

User's Guide. Phase Sequence and Motor Rotation Tester Model

Operating Instructions. For. Level Control Module. Model SSR 1000

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

M260 Load Cell Amplifiers

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Operating instructions Evaluation system for flow sensors VS / / 2013

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

User's Guide. Model High Precision Quad Output DC Power Supply

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

PGR-3200 MANUAL INSULATION MONITOR

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

AirTest Model CN9000 Series Sensor Controller

User s Guide. 600A AC Clamp Meter. Model 38387

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

BA505C 2-wire 4/20mA manual setpoint station Issue 6

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Plus-X 300. Installation and Operation Manual

ES-600 Ozone Controller Operation Manual

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

87421/22A Power Supply. Operating and Service Manual

Model Number Structure

Intrinsically Safe Barriers

OZONE SWITCH Model OS-6. OS-6 Features

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Analog Interface Unit Operation Manual

User Guide. Moisture Meter. Model MO250

USER MANUAL. WBI412F41 AC current transducer

InCos-P Pressure sensor 20 Pa Pa

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

iconverter 2-Module Power Chassis

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

USER MANUAL. WBI414F21 AC current transducer

Solid State Relays with Failure Detection Function

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CERTIFICATE of EU TYPE-APPROVAL

AE21 SERIES DISPLAY CONTROL TERMINAL

Transcription:

LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor

Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence of Operations... 4 Chapter 4 Specifications of the LCI... 7 Wiring Conditions... 8 Warranty... 8 1

LCI User Manual Chapter 1 Introduction to the LCI The LCI, Load Cell Failure Alarm, provides connectivity for 1 to 4 load cells to a Host instrument. The LCI s function is to continuously monitor the condition of the individual load cells and set an alarm condition, by de-energising an on-board relay, if any of the faults listed below are detected. Continuous detection and diagnosis of fault conditions prevents the incorrect weighing of product and the subsequent technical and commercial problems resulting from such situations. Any load cell malfunction is immediately reported by an alarm condition, avoiding incorrect material levels so that there is the continued assurance of correct product quantities. The avoidance of batch wastage or product recall, reduction in plant downtime and increased safety, together with aids for installation and commissioning all contribute to the LCI becoming an essential element for all weighing systems. An on-board microprocessor, 4½ digit display and six user switches provide a high level of intelligence enabling the following features:- 1. Load cell error detection: upon detecting an error, the alarm relay contact activates, the red Alarm LED illuminates and the display shows the load cell in error and the error code(s) (see chapter 3). An error is detected if any of the following occur: One or more of the load cells are out of balance with the pre-set error band Any load cell is operating outside its pre-set range The load cell excitation voltage drops Any of the load cells or its associated cabling become open or short circuit 2. A display of the mv output of each load cell or the average of the summed mv values of all the load cells. 4V to 12V Version: The latest version of the LCI (PCB issue 4 onwards) has been re-designed to enable it to operate from an excitation supply between 4V and 12V without requiring any special set-up procedure or link options. Host requirements: The Host must be capable of supplying power to the LCI as well as excitation for the load cells (see Chapter 4 for specifications). The Host s excitation supply feeds the load cells via a low voltage-drop reverse polarity protection circuit. An integral 5V regulator powers the on-board electronics. The LCI is compatible with Mantracourt s range of intelligent weighing instruments e.g. ADW15, LCA15, LCA20, LCD20, SMW etc. as well as suitable third-party products. 2

Chapter 2 Installing the LCI The LCI is supplied as a single PCB unit with four fixing centres to accommodate M4 screws. Case options are IP65 ABS (as standard), stainless steel, or DIN rail mounting. Installation of the LCI is simplified by the provision of six two-part plug-in connectors for wiring to the Host, the load cells and the alarm relay. Connection details are shown in the diagram below:- LCI Connection Details Important Note: When connecting less than four load cells to the LCI, start at channel one and fill the remaining channels in numerical order. Set the no C parameter accordingly (see table below). LCI Connections to LCB & ADW15 Details LCI LCA20 LCD20 LCB ADW15 +Ex +E & +S +E & +S +E & +S 5 & 6 +S +IN +IN +IN 4 Scr SCR SCR SCR 1 -S -IN -IN -IN 3 -Ex -E & -S -E & -S -E & -S 1 & 2 3

Chapter 3 Setting up the LCI The LCI features a 4-digit red LED display, four programming keys and two function keys. On Power Up, the display will show either good or display an error code e.g. 1Er5 which, in this case, would refer to Load Cell 1 with error condition 5. Sequence of Operations Programmer Keys 1 Used to scroll through and change the set-up data by displaying mnemonics for each configurable parameter followed by the appropriate data and stores the data in non-volatile memory. 2 Selects the display digit to be modified. Selection is indicated by a flashing digit. 3 Increments each selected display digit 0-9, or 9 to +9 for the most significant digit depending on whether the - sign is illuminated or not. 4 Saves the current value into non-volatile memory, exits the menu and resets the display to showing good or an error display. If, during the programming sequence, setting or interrogation is not completed, the display will revert to the status message after 2 minutes. Password Protection A 4 digit password number must be entered. The number is accessed when PASS is displayed. At this point, it is necessary to enter the factory-set number (1111). 4

Configurable Parameters Code Range Function 1111 Security password 1 to 4 Number of load cells ± 50.00 Load cell operating range Minimum (see 1) ± 50.00 Load Cell operating range Maximum (see 2) 0 to 50.00 Permissible error band between load cells (see 3) 0 to 25.0 Time in seconds before the alarm trips (see 4) 1. This is the lowest operating level (in mv) of any load cell connected. The alarm will activate if any load cell falls below this value. 2. This is the highest operating level (in mv) of any load cell connected. The alarm will activate if any load cell exceeds this value. 3. This is the permissible difference (in mv) between any 2 load cells. The alarm will activate if this value is exceeded. 4. This is the time (in seconds) an error must be present before the error alarm is displayed and output via the relay. The Error Displays on the LCI Note: On Power Up the display will show either good or ( ). Listed below is the range of errors which may occur, due to fault conditions in the weighing system, load cells or associated wiring. Display digit 1 shows which load cell is in error. Digits 2 and 3 show an error by displaying 4 displays any of five fault conditions as follows:-. Display digit Error Condition 1 An open or short circuit on the load cell or connectors (Check wiring and power supply) Error Condition 2 The load cell input is open circuit or has exceeded ± 50mV (Check wiring and power supply) Error Condition 3 Operating outside the pre-set maximum and minimum range ( & ) (Check wiring, cell mounting, Max /Min operating ranges) Error Condition 4 The load cell balance has exceeded the pre-set balance band ( ) (Check wiring, cell mounting, error band values) Error Condition 5 Open circuit of the excitation on the load cell or wiring. (Check wiring) Notes: 5

1. An open or short circuit may cause multiple errors. The display will cycle through multiple errors, displaying each code for 1 second. 2. To locate faults, start with the load cell, which displays the most errors. 3. The Set button automatically steps through the parameters and their values. During this function all other keys are disabled. 4. The red LED will be off during a healthy state and illuminated if an error occurs. The alarm relay is energised during a healthy state and drops out if an error occurs (fail safe). The Millivolt Display readings on the LCI To view the average of all of the load cell signals, press the mv button. To view the individual load cell signals, hold down the mv button and at the same time press and hold buttons 1 to 4 to select each load cell in turn. 6

Chapter 4 Specifications of the LCI Faults Monitored Powering Indication Setting Method Connections Dimensions Environmental Enclosure Material Load Cell out of pre-set balance range Load Cell out of pre-set operating range Low/high excitation Open circuit of any load cell connection Short circuit between any load cell connections Internal load cell fault (bridge imbalance) By Load Cell Excitation from Host 4 digit 7-segment LED display for set up, load cell error type, individual mv and average mv. 6 buttons for reading & set up 2 part terminals, up to 2.5mm² cable 4 x 5 way for load cell connection 1 x 5 way for LCI output and power input 1 x 3 way alarm relay contacts 200 x 120 x 75mm. (PCB dimensions 170 x 100mm excluding mounting material) Sealed to IP65 with cable glands & blanking plugs fitted CE Compliance. Grey ABS Parameters Min Typical Max Units Power supply voltage (from Host excitation supply) 4 5/10 12 Vdc Note 1 Power supply current (from Host excitation supply) - 70 80 ma Note 2 Load cell excitation 350R load cell 4 5/10 12 V Load cell resistance (typically 350-700R) 300 350 1000 Ohm Load cell sensitivity 1.0 2.0 5.0 mv/v Number of load cells selectable 1-4 Output load (Host input impedance) 1M - - Ohm Bandwidth (*display only) - 100 - Hz Zero temp. coefficient (*display only) @ 2mV/V @4V - 0.008 0.02 %FR/ C excitation Span temperature coefficient (*display only) - 0.001 0.0025 %/ C Linearity (*display only) - - 0.03 %FR 90 day Stability (*display only) - - 0.01 % 90 day Stability (*display only) - - 0.01 %FR Operating temperature range -10-85 C Storage temperature range -40-95 C Humidity - 95 - % Scan Speed for alarm output (4 cells) - 40 100 ms Display range -50 - +50 mv Relay contacts SPCO current (normally energized) - - 1 A Relay contacts SPCO DC voltage (normally energized) - - 24 VDC Relay contacts SPCO AC voltage (normally energized) - - 120 VAC Alarm operating speed for less than 1mV change - 100 - ms mv measurement accuracy individual cell (*display only) - - ±0.1 mv 7

Note 1: Derived from Host Instrument Note 2: Excluding load cell excitation current (*display only) denotes that the specification applies to the on-board display only, not the Host instrument. CE Approvals European EMC Directive 2014/30/EU BS EN 61326-1:2013 BS EN 61326-2-3:2013 Wiring Conditions Load Cell and Host cable connections should use individually screened twisted multi-pair cables (e.g. Farnell 118-2117) Terminate all screens at SCR. SCR should be connected to a good Earth. The earth connection should be of sufficient cross sectional area to ensure a low impedance to attenuate RF interference. Warranty All LCI products from Mantracourt Electronics Ltd., ('Mantracourt') are warranted against defective material and workmanship for a period of three (3) years from the date of dispatch. If the 'Mantracourt' product you purchase appears to have a defect in material or workmanship or fails during normal use within the period, please contact your Distributor, who will assist you in resolving the problem. If it is necessary to return the product to 'Mantracourt' please include a note stating name, company, address, phone number and a detailed description of the problem. Also, please indicate if it is a warranty repair. The sender is responsible for shipping charges, freight insurance and proper packaging to prevent breakage in transit. 'Mantracourt' warranty does not apply to defects resulting from action of the buyer such as mishandling, improper interfacing, operation outside of design limits, improper repair or unauthorised modification. No other warranties are expressed or implied. 'Mantracourt' specifically disclaims any implied warranties of merchantability or fitness for a specific purpose. The remedies outlined above are the buyer s only remedies. 'Mantracourt' will not be liable for direct, indirect, special, incidental or consequential damages whether based on the contract, tort or other legal theory. Any corrective maintenance required after the warranty period should be performed by 'Mantracourt' approved personnel only. In the interests of continued product development, Mantracourt Electronics Limited reserves the right to alter product specifications without prior notice. 8

Document Title: LCI User Manual Applies To: LCI Part Number: 517-164 Issue Number: 1.7 Dated: 22 November 2016 In the interests of continued product development, Mantracourt Electronics Limited reserves the right to alter product specifications without prior notice. www.mantracourt.com 9