COUNTIS ECi2 ECi3. Operating instructions Multi-utility pulse concentrator F GB D I NL E P

Similar documents
EC700. Pulses concentrator. User instructions

COUNTIS ATv2/ATiv2 GB

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

DIRIS D-30 DIRIS Digiware D-40 DIRIS Digiware D-50 Control and power supply interface

DIRIS Digiware DC Measurement and monitoring system for DC electrical installations

Module with RS485 communication option for

DIRIS N. Electrical network analysis system for quality control of your facilities

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

STATYS XS 16A / 32A CONFIGURATION MANUAL.

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

MDC-20. Maximum Demand predictive Control. Description

DIRIS B-10 & B-30. Multifunction meters and associated current sensors INSTRUCTION MANUAL. en/diris-b

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Multifunction Transducer MT440

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

RXTH DUAL ROOM SENSOR / SWITCH

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Programmable Relay ZEN V2 Units

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

CEM-C6 INSTRUCTION MANUAL (M187B B)

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Operating Instructions

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

RXTP ROOM TEMPERATURE

Neon pr. ph/ ORP measurement. Applications. Description

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Operating instructions. Speed monitor D / / 2014

DIRIS. The multi-function measurement UL range for managing your electrical networks

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

DIRIS Digiware D and C Communication and control power interfaces

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

ATS CONTROLLER OPERATING MANUAL

MIC-2 Multi-instrument DATA SHEET

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

mark150s mark150/485s DDC controllers Summary

SM210 RS485 - JBUS/MODBUS for SM102E. User instructions

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DIRIS A & DIRIS B Power Metering and Monitoring Devices

RTD-W Installation Instructions

Power Meter PowerMonitor 500

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

COUNTIS E. Active and reactive energy meters and multi-utility pulse concentrators

TIME SERVER NETSILON. Quick start.

Installation Manual. Multi Power Controller MPC-1 multi-line D

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

DIRIS Ap. Out 0/4 20 ma. Industrial Switching & Protection Systems

Operating instructions. Switching amplifier DN0210 DN / / 2015

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

DIRIS A. The multifunction multi-measurement station MADE TO MEASURE

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

Voltage Transducer UMT516 / MT516

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Installing and Configuring Rialto Analytic Appliances

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

RТTH DUAL ROOM SWITCH

DIRIS A. The multi-function measurement range MADE TO MEASURE

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

WEBVIEW Software solution for energy monitoring and analysis

DATA SHEET Compact Genset Controller, CGC 200

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

E2Q4 Square Proximity Sensor

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

RS 485 Mini Modbus 1AO

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

DIRIS A. The multi-function measurement range MADE TO MEASURE

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

DIRIS N300/N600 Network analysers Network quality control and analysis system

COUNTIS E. Active and reactive energy meters and multi-utility pulse concentrators

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Products no longer available

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

RS485 MODBUS Module 6RO

DIRIS A-30 Multifunction power metering & monitoring device - PMD

Temperature/Process Controllers Manual

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

CDD4 Duct Carbon Dioxide Transmitter

Making Hazardous Operations Safe and Productive

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Transcription:

COUNTIS ECi2 ECi3 Operating instructions Multi-utility pulse concentrator F GB D I NL E P

GB Contents HAZARDS AND WARNING...3 INITIAL CHECKS...3 INTRODUCTION...4 JBUS/MODBUS COMMUNICATION...6 INSTALLATION...7 CONFIGURATION...10 USE...11 PROGRAMMING...12 TECHNICAL CHARACTERISTICS...13 TROUBLESHOOTING...14 2 COUNTIS ECi - Ref.: 538 470 A

HAZARDS AND WARNING Qualified personnel and correct operation The equipment described in this document may only be installed, commissioned and operated by trained, qualified personnel. Failure to follow the procedures given in these instructions does not imply liability on the part of the manufacturer. Standards, directives, legal provisions and local regulations must be complied with. Risk of electrocution, burns or explosion before working on the device, isolate all dangerous live components, always use an appropriate voltage detection device to confirm the absence of voltage, replace all components, doors and covers before reconnecting this device to the power supply, always use the appropriate specified voltage to supply this device. Failure to comply with these precautions could result in serious injuries. Risk of damage to the device Ensure the correct: voltage across the AUX SUPPLY power supply terminals, 110-400 Vac / 50-60 Hz, voltage across the OUTPUT relay, 250 Vac or 30 Vdc. INITIAL CHECKS For the safety of personnel and equipment, it is essential to read all of these instructions before using the device for the first time. Confirm the following points upon receipt of the package containing the COUNTIS ECi : the packaging is in good condition, the product is in good condition, the device part number matches that specified on your order, the contents of the package: 1 product, 1 resistance for line impedance ref: 48990019, 1 mini CD, 1 quick start instructions. 3 COUNTIS ECi - Ref.: 538 470 A

INTRODUCTION The COUNTIS ECi is a pulse concentrator equipped with 7 digital inputs (logic or pulse signal), 2 analogues 0/4-20 ma inputs (model ECi3) and an RS485 connection to the JBUS/MODBUS protocol. It centralises and memorises pulses or logical signals in the output of electrical (COUNTIS E type), gas, heating oil, water and compressed air meters or measurement units (DIRIS type) in order to: send them via the RS485 communication output to a remote energy management system (ENERGY REPORTING ), display a large number of these items on its local display screen for direct reading of information, generate event alarms (1 dedicated relay output). The COUNTIS ECi enables advanced customisation of all items, facilitating direct reading of information concentrated in this way: metering unit per input: kwh, m³ currency / input:, K,, $, logical inputs (NO/NF, delay) or pulses (weight, synchronisation source, time intervals for load graphs), logical output: configurable alarm, NO/NF and time delay, analogue inputs: 0 or 4/20 ma, min/max in physical unit, time interval for load graphs. (ECi3 version) It is also possible to display, at any time: the physical status of each of the 7 digital inputs (contact open or closed, pulses present or not), the physical and functional status of the logical output (contact open or closed, output active or inactive), the status of 5 customisable events: date, activation time, duration, type (logical, threshold, or combination of 2 events), severity (4 information levels), the relative value (%) and absolute value (in the chosen unit) of the 2 analogue inputs. (ECi3 version) The communication interface of COUNTIS ECi is 2-wire RS485 type using JBUS/MODBUS protocol and enables: remote access to all information produced by COUNTIS ECi units, above and beyond that displayed on its screen (cf. application note or JBUS/MODBUS table), this COUNTIS to be operated from a PC or programmable logical controller (API/PLC). This product can be configured locally (PROG menu) or by remote communication. The COUNTIS ECi2 has the following functionalities, with direct reading on the display and values saved to memory: Total and partial metering in the chosen unit with currency equivalent, Daily, weekly, monthly or annual metering, Partial metering from the last synchro trigger (in progress), Metering on customised trigger (Perso), For each input, it memorises pulses by integrating them over a programmable interval (from 1 to 60 min in 1 min steps) to reconstitute a load graph. Whatever the chosen integration interval, the load graph is created over a sliding period of 17 days. All information is accessible through JBUS/MODBUS. 4 COUNTIS ECi - Ref.: 538 470 A

The COUNTIS ECi3 has the functionalities of the COUNTIS ECi2. It also has 2 analogue 0/4-20 ma inputs with the following functionalities: Instantaneous relative (%) and absolute (in the chosen unit) values,with direct reading on the display, For each analogue input, it memorises values by integrating them over a programmable interval (from 1 to 60 min in 1 min steps) to reconstitute a load graph, Whatever the chosen integration interval, the "analogue input" load graph is created over a sliding period of 17 days, All information is accessible through JBUS/MODBUS. A B C D E F G A B D F G Backlight LCD display and and C Keys to scroll through Menu functions (right-left) E Keys to scroll through Menu sub-functions (top-bottom) Access key for programming functions (PROG) LED to indicate communication frame on RS485 port addressed by it 5 COUNTIS ECi - Ref.: 538 470 A

JBUS/MODBUS COMMUNICATION RS485 MEDIA In a standard configuration, one RS485 connection enables 32 UL* to be connected to a PC or PLC over 1200 metres using the JBUS/MODBUS protocol. * 1 UL = 1 Countis ECi. Recommendations: An LIYCY type shielded twisted pair must be used. In a disturbed environment, we recommend using a shielded twisted pair with general LIYCY-CY shielding. If the distance is greater than 1200 m and/or there are more than 32 COUNTIS, it is necessary to connect a repeater (1 channel) or a spark arrester (2 channels) to enable the connection of additional COUNTIS. (with communication interface over more than 1200 m) For more information on the connection procedure, refer to the technical bulletin available on the web site: www.socomec.com Important: It is essential to connect a resistance of 120 Ohms to the 2 ends of the connection; this can be found in the product packaging. Other solutions are available (modem, fibre optic, etc.); please ask for details. JBUS/MODBUS PROTOCOL The JBUS/MODBUS protocol operates on a master/slave structure: Reading (Function 3), Writing (Function 6 or 16), broadcast option at address 0. The communication method is RTU (Remote Terminal Unit) with hexadecimal characters comprising a minimum of 8 bits. JBUS/MODBUS TABLE File Ref: 538471 Can be downloaded from the web site: www.socomec.fr R=120Ω R=120Ω R=120Ω R=120Ω R=120Ω R=120Ω 6 COUNTIS ECi - Ref.: 538 470 A

INSTALLATION The COUNTIS ECi meter can be mounted on a 35 mm rail (EN 60715TH35). It must be used inside electrical cabinets. Connection Aux.: 110 400 Vac 120 300 Vdc Fus.: 0.5 A gg / BS 88 2A gg + - 250Vac 3A Relay 30Vdc / 1A 0/4...20mA Sensor 0.14 / 2.5 mm 2 0.14 / 2.5 mm 2 5 mm 0.6 Nm 0.2 / 6 mm 2 0.2 / 4 mm 2 8 mm 0.6 Nm R=120Ω RS485 7 COUNTIS ECi - Ref.: 538 470 A

Connecting logical inputs - Internal polarisation, cable length 1000 m max, 1.5 mm² min. - External polarisation, cable length 1000 m max, 1.5 mm² min. DC Stabilized + - power supply AC 10-30 Vdc 8 COUNTIS ECi - Ref.: 538 470 A

Connecting analogue inputs (COUNTIS ECi3 version) - Passive sensor 0/4...20mA + - 0/4...20mA Passive sensor + - DC AC Stabilized power supply - Active sensor 0/4...20mA + - 0/4...20mA Active sensor 9 COUNTIS ECi - Ref.: 538 470 A

CONFIGURATION To enter configuration mode, press the PROG key for 3 sec. You are asked for a code: Normal user: code 1000 (default value, configurable number): all parameters can be modified EXCEPT those locked by the code 6825. Advanced user: code 6825 (not configurable): allows access to all parameters accessible with the code 1000, as well as sensitive "maintenance" parameters: Factory settings and Input Reset. After 1 min if a key is not pressed = automatic exit from programming mode. The configuration is not saved. To save and quit programming mode, press and hold PROG. 10 COUNTIS ECi - Ref.: 538 470 A

Total / Partial Day / Week Month / Year OnGoing / Custom The screens presented in the USAGE / PROGRAMMING charts are not all visible: their display depends on the version of your COUNTIS ECi and their configuration. Log. Inputs Input/State/Pulse Ana In 1 Rel / Abs Alarm 1 Type / Sever / State Date / Time Total and partial metering Analogue input: Digital input: Logical input, physical status and presence of pulses relative value (%) and absolute value Date and time setting Event 1 information: type, seriousness, status Tot / Part Cost Idem Input 2 > Daily and weekly metering Analogue input: Dig. Stat/Phys/Func Ana In 2 Rel / Abs relative value (%) and absolute value Alarm 1 Date / Duration Top Synchro Last Top Inputs 1 to 7 if logical programming Monthly and yearly metering Date and time of last sync signal Date and time of start of event 1 and duration if completed Output Dig. Stat/Phys/Func Logical output and functional status Idem Alarm 2 > Alarm 5 Metering since the last sync signal and personal metering Equivalent in currency of Total and Partial metering. Name, software version Information and product serial no. Name / Ver / SN. USE 11 COUNTIS ECi - Ref.: 538 470 A

PROGRAMMING Hold down for 3 seconds. The screens presented in the USAGE/PROGRAMMING charts are not all visible: their display depends on the version of your COUNTIS ECi and their configuration. Modification with code 1000 Modification with code 6825 Mode Pulse meter, logical status or deactivated Inputs Cost Currency Currency setting Output Src / Type / Delay Logical output setting: source of control, NO/ NC type and time Ana In 1 Type / Unit Typical setting: 0/20mA, 4/20mA or deactivated and unit Alarm 1 Mode / Sever Mode: logical, analogue, combination or deactivated Com JBUS Adress / Mode Mode, address setting * Date Day / Month / Year Day, month, year setting Language English Language selection Maintenance Factory Cfg / Action Reset to factory settings Type / Delay NO/NC type and time Enable / Cost Currency conversion activation Ana In 1 Min / Max Sensor setting (mesurement range) Alarm 1 Src / Type Logical alarm setting: source and type Com JBUS Baudrate/ Stop / Parity Speed, stop, parity setting Heure Hour / Minute / Second Hours, minutes, seconds setting Lock Code 1000 Password selection, used for modifying the config. Maintenance Input Reset / Src / Act Input reset Unit / Weight Pulse weight and unit Idem Input 2 > Input 7. Ana In 1 Synchro / Integ Sync source and integration time Alarm 1 Src1 / Src2 / Type Setting of combination alarm: source 1, source 2 and type Display Contr./ Backl./ Timeout Contrast, brightness, standby setting Synchro / Integ Sync source and integration time Idem Ana In 2. Alarm 1 Src / Type / Hyst Setting of analogue alarm: source, type and hysteresis Reset/ Partial/ Custom Pulse metering reset Alarm 1 Low / High Setting of analogue alarm: low or high limit Idem Input 2 > Input 7. Idem Alarm 2 > Alarm 5. * MANUAL mode This mode enables manual configuration of all communication parameters JBUS/MODBUS: Address, Speed, Parity, Stop bit. AUTO mode This mode enables automatic configuration of most of the communication parameters (Speed, Parity, Stop bit). Only the communication address for the COUNTIS has to be entered. The mode only functions under the following conditions: Communication speed between 9600 and 38400 baud. JBUS/MODBUS frame format: - 8 bits + 2 stop + no parity, - 8 bits + 1 stop + parity. 12 COUNTIS ECi - Ref.: 538 470 A

TECHNICAL CHARACTERISTICS Min Max Units Comments Auxiliary power supply AC voltage 110 400 Vac +/-10%, 45/65Hz, 5VA DC voltage 120 300 Vdc +/-10%, 5VA Climate Ambient temperature -10 55 C IEC 60068-2-1/ -2-2 Storage temperature -20 70 C IEC 60068-2-1/ -2-2 Ambient humidity 95 %RH IEC 60068-2-30 Vibration Vibration 2 G IEC 60068-2-6 10 to 100Hz Case Dimensions 73x90x67 mm L x W x H Weight 215 g Protection index of enclosure IP51/IP20 Front/Case Electrical safety Cat. Install. /degree of pollution III/2 IEC 61010-1 ed. 3 (300Vac Ph/N) Updating period Display 1 Sec RS 485 communication 0,5 Sec Digital inputs Direct voltage 10 30 Vdc Terminal 50 reference Current 2 15 ma According to IEC 62053-31 Class B Line length 1000 m Min. section 1.5mm² (#16AWG) Pulse duration 30 ms max. 16Hz Power consumption per input 0,4 VA Internal digital input polarisation power supply Voltage 10 15 Vdc (Max. 35mA) Analogue inputs Current 25 ma Accuracy 0.5 % % full scale Response time 500 ms Input resistance 200 Ω Power consumption per input 0,1 VA Relay output Set-up (contact setting) Mechanical strength AC breaking DC breaking 1 contact (NO, NC) 10 5 cycles 250Vac/3A 30Vdc/1A RS485 bus communication (JBUS/MODBUS protocol) Line length 1200 m Number of equipment 32 2 shielded wires + half duplex Modulation speed 9.6K, 19.2K, 38.4Kbds This symbol indicates that the product may not be disposed of with other household waste, so as not to harm the environment or human health (WEEE directive, 2002/96/EC). Please refer to the standard terms of sale of Socomec for more information on the method for disposing of this product. Compliant with RoHS directive. COUNTIS ECi complies with the following European directives: - Electromagnetic Compatibility Directive, no. 2004/108/EC (2004/12/15) - Low Voltage Directive, no. 2006/95/EC (2006/12/12) Device fully protected with double insulation. 13 COUNTIS ECi - Ref.: 538 470 A

TROUBLESHOOTING Device not switched on Check the power supply cable. 110 400 Vac or 120 300 Vdc between terminals 20 and 22, if there is voltage present and the device does not switch on, please return the device to us. Faulty communication Check configuration in MANUAL mode: address, speed, parity, stop bit (p.12) and cabling (p.6). For more information on the RS485 connection procedure, refer to the technical bulletin available on the web site: www.socomec.fr The meter does not advance incrementally Poor connection. Go to the menu E. Digital. (p.11) Connect the input to be tested to terminal + 51 (p.8) to verify that the "pulse detected" pictogram changes state correctly. 14 COUNTIS ECi - Ref.: 538 470 A

SOCOMEC - Ref.: 538 470 A - 02/11 HEAD OFFICE SOCOMEC GROUP S.A. capital 11 302 300 R.C. Strasbourg 548500 149 B 1, Rue de Westhouse - B.P. 60010 - F-67235 Benfeld Cedex - FRANCE www.socomec.com INTERNATIONAL SALES DEPARTMENT SOCOMEC 1, rue de Westhouse - B.P. 60010 F - 67235 Benfeld Cedex - FRANCE Tél. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00 scp.vex@socomec.com This document is not a contract. SOCOMEC reserves the right to modify features without prior notice in view of continued improvement.