SP-5T Common Line Intercom System

Similar documents
Command Talk-Back & Public Address System ETB-5 / ETB-10 / ETB-10A / ETB-100 / ETB-100A

STENTOFON PRO700 ExchangElEss IntERcOm

INSTALLATION INSTRUCTIONS LKP-957

bi-way starter kit lbb 7026/65 MI v.1.2 mounting guide

Data Network Guidelines for Ships

AlphaCom SIP GSM Gateway

Configuration Manual. Flowire Converter FCDC1 / FCDC2 TECHNICAL MANUAL A100K11422

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

PRO700 EXCHANGELESS INTERCOM CRITICAL COMMUNICATION

PO Box 409 Hanover, MD TEL (410)

VINGTOR talk-back & intercom systems

STENTOFON PULSE SERVERLESS INTERCOM

NATIVE IP PUBLIC ADDRESS & GENERAL ALARM SYSTEM

INSTALLATION INSTRUCTIONS

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

NATIVE IP PUBLIC ADDRESS & GENERAL ALARM SYSTEM

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

INSTALLATION INSTRUCTIONS. This document describes the installation procedure for the SAB-400 and SAB-401 Station Audio Board.

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

(DISTRIBUTED AMPLIFIER BASED DESIGN) (NON BLOCKING TYPE).

INSTALLATION INSTRUCTIONS

AD-1 POWER SUPPLY. AD-1 listed AC ADAPTER. Supplies 12 Vdc to both AP-1TB and remote speaker/microphone.

INT-HD52 Quick Install Guide

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

Advanced Visual Solutions Ltd

PM1. Paging Microphone. Installation and User Guide

CS2000 Conference systems

LS351 Desktop, single circuit unit, with XLR connectors (XLR3F, XLR3M loop-through). Local plug-in PSU option.

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

poly-planar Marine Audio System

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

INSTALLATION INSTRUCTIONS

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

GARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1

Technical data sheet 6211, Telephone, Industrial, UpN, IP56 Art. no

MCS 50. Discussion Control Unit. 1 of 7

Audio Specialties Group Products Division MODEL AOB-2 INTERCOM-AUDIO INTERFACE ADAPTOR

IC-I AND IC-I F GENERAL DESCRIPTION SPECIFICATIONS. Output Impedance: Phones: 60 ohms (Unit is designed for use with ohm phones.

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

ONBOARD ROLLING STOCK COMMUNICATION

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

V-9939C MICROPHONE ADAPTER

CORRIGENDUM No: 1 to the TECHNICAL SPECIFICATIONS

PUBLIC ADDRESS SYSTEM

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

INTERCOM SYSTEM Model ICA900

Connexus Communications Limited STENTOFON PULSE Intercom for Everyone

FUSION MS-RA70/MS-RA70N Installation Instructions

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Audio Specialties Group Products Division MODEL AOB-2 INTERCOM-AUDIO INTERFACE ADAPTOR

RD-44 Audio Network Control Panel

Serverless Page/Party

Technical data sheet 7211, Telephone, Industrial, VoIP, IP56 Art. no

MODEL 805 USER MANUAL

ET 908. IP-Intercom Module ET 908 DATASHEET PRELIMINARY

TELIKOU Intercom System

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

MASELEC MTC-6 master transfer and monitor system

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

LSP 500 PRO. Wireless Integrated Professional Audio System FEATURES ARCHITECT S SPECIFICATION

AP-4 4 ZONE AUDIO BASE STATION INSTALLATION AND OPERATING INSTRUCTIONS

Technical data sheet 6223, Telephone, Console, UpN, IP22 Art. no

Model SAP612 Source Assign Panel User Manual

SS-22 USER MANUAL. Revision 01 Original document 04 May 2006 Revision 02 Cosmetic changes 23 January 2008 CONTENTS

Installation Manual. Balboa Bluetooth Audio (bba 2)

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

AN-3000A IC(A6) INDUSTRIAL HEADSET (FOR ICOM A6 A24)

User Manual MP-HDDE2. HDMI Audio Splitter/De-embedder 1x2. All Rights Reserved. Version: MP-HDDE2_2016V1.0

HP4 headphone amplifier. user manual

CU 4005 CDS 4000 Central Control Unit for 50 Conference Units

DVS-21 product catalogue 2015 V1.03. Table of contents:

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

TELIKOU Intercom System FT-800 (7+1) Channel Main Station Instruction Manual

Installation Manual. Balboa Bluetooth Audio bba 2

STENTOFON SIP. UNIFIED COMMUNICATION One System, One Language, Endless Possibilities

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

CS-1 Active Full Range Integrated Commercial Audiovisual System

IP Desktop Intercom Stations 12 NIB 001 Series

Connexus Communications Limited STENTOFON SIP UNIFIED COMMUNICATION One Network, One Language, Endless Possibilities

Cube67 - Modular I/O station

INSTALLATION AND MOUNTING MANUAL

AP-16TB 8 ZONE AUDIO BASE STATION INSTALLATION AND OPERATING INSTRUCTIONS

ICM-400 Series Intercom Stations

MPS01. Paging and Emergency Microphone

Rev. Date Author Status/Comments Mar 2010 HKL

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

Digital Intercom Stations DTM Series

Page/Talk Industrial Desk Sets

WIRELESS INTERCOM SYSTEM Service Information

FPA-1 Facility Port Adapter Installation Guide

Transcription:

SP-5T Common Line Intercom System TECHNICAL & USER MANUAL

About this Document Document Scope This document describes the system features, available equipment, typical configurations, simplified wiring and technical specifications for the SP-5T Common Line Intercom System. Publication Log Rev. Date Author Comments 0.0 2002.05.07 SEN First release Zenitel Marine. main units with new circuit, balanced output. Ver. 01 0.1 2002.08.20 SEN Documents for Ver. 02 in addition SP-5MT & HT with new PCB. Type VP1207 (Ecas) same function. 1.0 2010.08.25 SEN New front and back page, new datasheets Doc.no. SP-5T_ut Rev.01 is replaced by document no. Handheld mic type H66-SP5 1.1 2011.04.11 HKL Headset type SP5-36-PELP Proofread and converted all contents into Indesign format Related Documentation Documentation Datasheet - SP-5MT Datasheet - SP-5HT Datasheet - SP-36-PELP Datasheet - H66-SP5 Datasheet - Power Amplifier VPA-120 Datasheet - Power Amplifier VPA-240 Datasheet - Power Amplifier VPA-400 Datasheet - Amplifier Rack RS-3C Cable Connection Diagram - SP-5T Cable Connection Diagram - SP-5T Ver. 02 Wiring Diagram - Amplifier Rack RS-3C Installation & User Manual - VPA-120/VPA-240/VPA-400 Doc. no. A100K10948 A100K10947 A100K10949 A100K10944 A100K10504 A100K10505 A100K10506 A100K10711 SP-5T_cc_wd SP-5T Ver.02_cc_wd RS-3C_wd rev.02 A100K10875 Zenitel Norway AS and its subsidiaries assume no responsibilities for any errors that may appear in this publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty by Zenitel Norway AS. The information in this publication may be updated or changed without notice. Product names mentioned in this publication may be trademarks and are used only for identification. Zenitel Norway AS 2011 2 SP-5T Technical & User Manual

Contents 1 General Description...4 2 Installation Instructions...5 2.1 General...5 2.2 Cable Requirements...5 2.3 Level Adjustment...5 3 User Instructions...6 4 Connection Diagrams & Dimension Drawings...7 4.1 SP-5T Ver. 02 Cable Connection Diagram...7 4.2 SP-5T Cable Connection Diagram...8 4.3 SP-5MT Microphone Station...9 4.4 SP-5HT Microphone Station...9 4.5 SP5-36-PELP Headset...10 4.6 H66-SP5 Handheld Microphone...10 5 Specifications... 11 5.1 SP-5MT Microphone Station... 11 5.2 SP-5HT Microphone Station... 11 5.3 SP5-36-PELP Headset... 11 5.4 H66-SP5 Handheld Microphone... 11 SP-5T Technical & User Manual 3

1 General Description The SP-5T Common Line Intercom System provides All-to-All communication between a specified numbers of microphone or headset stations. The number of stations that can be connected depends on output power and loudspeaker tapping. LLNote that product versions 01 & 02 have the same functions, except they have different PCBs. The system consists of : Watertight Microphone station, type SP-5MT --for handheld microphone, type H66-SP5 Watertight Microphone station, type SP-5HT --for headset with boom-microphone, type SP5-36-PELP 100V line loudspeaker for each station Rack, type RS-3C with VPA-120, VPA-240, or VPA-400 power amplifier 4 SP-5T Technical & User Manual

2 Installation Instructions 2.1 General For proper installation and operation of the SP-5T system, we recommend reading this section thoroughly together with the installation drawings. Make sure that all mounting and cabling are correct before switching the system on. The amplifier rack and power supply is for installation indoors while the weatherproof and rugged microphone stations and loudspeakers are for outdoor use. Amplifier rack RS-3C/VPA The amplifier rack and power supply should be mounted in a normal and ventilated indoor environment with a temperature of 0-55 C. It is equipped with screw terminals for cables with a maximum length of 2.5 mm 2. Microphone station type SP-5MT & Headset station type SP-5HT The Microphone/Headset stations and loudspeakers are weatherproof and designed for outdoor use. It is equipped with screw terminals for cables with a maximum length of 2.5 mm 2. LLCaution: Use separate cables for input and output signals. 2.2 Cable Requirements All signal cables have to be approved ship cables with twisted pair at a minimum of 2 x 0.75 mm 2 and outer screen. The screens must be interconnected in junction boxes and grounded in terminal X2-1 in amplifier rack RS-3C only. They are open in SP- 5T stations. LLNote that proper grounding is essential for reliable operation. 2.3 Level Adjustment Adjust the volume control at the rear of the amplifier with a screw driver until you have a suitable power level. This volume is now permanently set. The power amplifier VPA-120, VPA-240 or VPA-400 must always be in the ON position. SP-5T Technical & User Manual 5

3 User Instructions To use the system: Press the TALK button and speak clearly into the microphone. When you press the TALK button and speak into the microphone or headset microphone from any station, you can be heard in all other loudspeakers or headsets. The station s own loudspeaker will be muted. 6 SP-5T Technical & User Manual

4 Connection Diagrams & Dimension Drawings 4.1 SP-5T Ver. 02 Cable Connection Diagram SP-5T Technical & User Manual 7

4.2 SP-5T Cable Connection Diagram 8 SP-5T Technical & User Manual

4.3 SP-5MT Microphone Station 224 63 204 82 124 PG-13 PG-11 PG-11 PG-11 PG-13 Mounting holes diam. 6.0 mm 4.4 SP-5HT Microphone Station 224 63 124 PG-13 PG-11 PG-11 PG-11 PG-13 204 82 Mounting holes diam. 6.0 mm SP-5T Technical & User Manual 9

4.5 SP5-36-PELP Headset 95 60 200 10m cable 10m cable 55 110 40 124 40 Headset holder 55 18 38 4.6 H66-SP5 Handheld Microphone Ø 54 54 24 81 52 10 SP-5T Technical & User Manual

5 Specifications 5.1 SP-5MT Microphone Station Material Color IP rating Dimensions (WxHxD) Weight Operating voltage Loudspeaker output Cable requirements Bayblend plastic housing Grey IP-65 224 x 124 x 63 mm 0.9 kg 24V DC 100V, balanced Twisted pair with outer screen, input and output must be in separate cables Connections Screw terminals for cable max. 2.5 mm 2 Accessories Handheld microphone H66-SP5 5.2 SP-5HT Microphone Station Material Color IP rating Dimensions (WxHxD) Weight Operating voltage Loudspeaker output Cable requirements Bayblend plastic housing Grey IP-65 224 x 124 x 63 mm 0.9 kg 24V DC 100V, balanced Twisted pair with outer screen, input and output must be in separate cables Connections Screw terminals for cable max. 2.5 mm 2 Accessories Headset SP5-36-PELP 5.3 SP5-36-PELP Headset Connections Headset Color IP rating Weight 7-pin plug Peltor MT 7H7A Black IP-54 1.2 kg 5.4 H66-SP5 Handheld Microphone Type/article no. Holmco 66 / 84-15-06980 DC resistance Microphone sensitivity Power capacity LS sensitivity 200 ohm 0.5 mv/dyne/sq.cm at 1 khz 0.2 W (0.5 W peak) Working temperature -30 to +60 C IP rating Color Weight 57 db/mw at 1 khz and 50 cm distance, i.e. 80 db at 0.2W audio-frequency power IP-66 Black 0.3 kg SP-5T Technical & User Manual 11

www.vingtor.com Zenitel Norway AS DOC NO. support@vingtor.com VINGTOR products are developed and marketed by Zenitel Norway AS. The company s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001:2008. Zenitel Norway AS reserves the right to modify designs and alter specifications without prior notice, in pursuance of a policy of continuous improvement. 2011 Zenitel Norway AS.