Digital Vane Thermo-Anemometer Model

Similar documents
Heavy Duty Mini Vane CFM Thermo Anemometer

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

Hygro Thermo-Anemometer Model

User's Guide. Heavy Duty Differential Pressure Manometer. Model

User's Guide. Datalogging Light Meter with PC Interface. Model

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Heavy Duty Datalogger Module

Heavy Duty Vibration Meter

User Guide. Moisture Meter. Model MO250

Heavy Duty Datalogger Module

User's Guide. Model Laser Photo Tachometer

Mini Photo Tachometer Model Mini Contact Tachometer Model

User s Manual. Model and Sound Level Calibrators

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User's Guide. Digital Sound Level Meter. Model

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

User's Guide. Video Borescope. Model BR100

Heavy Duty Datalogging Light Meter

User's Guide. Temperature / Humidity Datalogger. Model 42270

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

User s Guide. 600A AC Clamp Meter. Model 38387

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

Laser Photo/ Contact Tachometer. m/min. ft/min

Heavy Duty Hot Wire CFM Thermo-Anemometer

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Heavy Duty Psychrometer + IR Thermometer Model HD500

3-Axis G-Force Datalogger

True RMS AC Voltage/Current Datalogger

User's Manual Sound Level Alert Model SL130

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Guide. Hot Wire Thermo-Anemometer. Model

User's Manual. Digital Sound Level Meter. Model

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Integrating Sound Level Datalogger Model

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Manual. VA893 Thermo Anemometer

Digital Sound Level Meter

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Model High Precision Quad Output DC Power Supply

User's Guide Video Borescope Model BR200

Power Analyzer Datalogger Model

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

Dual Input, 3-Display Thermometer/Datalogger Model

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

User Guide. ExStik FL700. Fluoride Meter

Mini Digital Multimeter

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Large Vane CFM/CMM Thermo-Anemometer

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

User's Guide. Mini Microscope. Model MC108

Mini Environmental Quality Meter

Anemometer SD Card Datalogger. Instruction Manual

Mini Environmental Quality Meter

Anemometer/Thermometer

Digital Air Velocity/Flow Meter

Large Vane CFM/CMM Anemometer / Psychrometer

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

User Guide. Conductivity Meter. Model EC210

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

Torque Meter. Instruction Manual

VANE ANEMOMETER HUMIDITY/TEMP.

Vibration Meter SD Card real-time datalogger

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

DAF4207SD USER S MANUAL

DIGITAL ANEMOMETER Model : AM-4203

Mini Environmental Quality Meter

ENVIRONMENT METER WITH DATALOGGING SD CARD

4-Channel Thermometer / Datalogger

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

Datalogging Hot Wire CFM Anemometer

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200. Anemometer Thermometer AN200 UNITS NEXT AREA RECALL.

Hygro-Thermometer / Datalogger

Heavy Duty Differential Pressure Manometer. Model User's Guide

User Manual. Data Logging Anemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Heavy Duty Vibration Meter

CFM/CMM Hot-Wire Thermoanemometer

MINI ANEMOMETER- PSYCHROMETER WITH COMPASS AND MEMORY USER S MANUAL

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

12-Channel Thermocouple Datalogger

Light Meter SD Card real-time datalogger

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Mini Environmental Quality Meter

Digital Air Velocity Meter DC580. The Value Leader TM

TA 888 Hot Wire Anemometer

Transcription:

User's Guide Digital Vane Thermo-Anemometer Model 451104

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Introduction Congratulations on your purchase of the Extech 451104 Vane Thermo-Anemometer. This device measures air velocity and temperature, displaying both simultaneously. The measurement vane is built into the meter for ease of use. This meter stores the highest (MAX), lowest (MIN), and average (AVG) readings for easy recall. The built-in RS-232 PC Interface jack can be used to capture readings on a PC as they are taken using the optional Model 407752 interface kit. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service Meter Description 1. Air velocity sensor with built-in Temperature sensor 2. Data Hold button 1 3. Min/Max/Avg Record button 4. Unit of measure button 5. ON-OFF power button 6. Set-up key (used for programming as described in this manual) 7. LCD air velocity display 8. LCD temperature display 9. RS-232 PC port 5 6 9 2 3 4 7 8 Note that the battery compartment is located on the back of the meter 2

Operation Meter Power 1. This meter is powered by one 9V battery. To replace or install the battery, refer to the section Battery Replacement. 2. Press the ON-OFF button to turn the meter on. If the meter does not switch on, check the battery. 3. When the meter switches on it runs through a 2-second self-test. When the self-test is finished, the VEL display icon will appear in the upper left hand corner of the LCD. VEL is the Air Velocity indicator. When it appears, the meter is ready for use. Air Velocity Measurements 1. Turn the meter on and hold the measurement vane in the path of the air stream. 2. Read the Air Velocity and Temperature measurements on the LCD display. Air Velocity readings are displayed in the center of the LCD while the Temperature reading is shown on the bottom right of the LCD. Data Hold In cases where it is difficult to see the LCD display while taking a measurement, the meter can freeze the measurement on the LCD for later viewing. 1. At any time during a measurement, press the HOLD button to freeze the reading. The Hold display icon will switch on to alert the user that the meter is in the HOLD mode. 2. To exit this mode, press the HOLD button again (the Hold display icon will switch off). Selecting the units of measure The meter can be used in either the feet per minute / o F mode or the meters per second / o C mode. In the ft/m mode, the available air velocity units are ft/min (feet per minute), mil/h (miles per hour) and knots (nautical miles per hour). Use the UNIT button to change the unit of measure. In the m/s mode, the available air velocity units are m/s (meters per second), km/h (kilometers per hour) and knots (nautical miles per hour). To change from one mode to the other, follow these steps: 1. With the meter off, press and hold the SETUP button. 2. Press and release the ON button and at the second beep release the SETUP button. 3. The LCD will indicate Air Velocity units and temperature units. 4. Press the HOLD button to set the units to meters per second (m/s) and o C. Press the SETUP button to set the units to feet per minute (ft/m) and o F). 5. Press the RECORD button and an S will appear. 6. Press the HOLD button to save the setting. 7. 1200 or 2400 will appear on the LCD. This is the RS-232 PC Interface baud rate. 8. Press the HOLD button to set the baud rate to 1200 or the SETUP button to select a 2400 baud rate. 9. Press the RECORD button and an S will appear. 10. Press the HOLD button to save the setting and return to the normal operating mode. 3

Minimum, Maximum, and Average Record / Recall This meter can be placed in the RECORD mode and keep track of the highest (MAX), lowest (MIN), and average (AVG) readings. The MIN, MAX, and AVG readings can be viewed at any time at the press of a button. To use these features, follow these steps: 1. Press the RECORD mode until a beep is heard 2. The REC display indicator will appear. The meter is now keeping track of the highest, lowest, and average readings 3. Now use the RECORD button to move between the four displays listed below: MAX mode: The MAX display mode shows the highest reading encountered since the meter was placed in the RECORD mode. In this mode the MAX and REC indicators will be on the LCD. MIN mode: The MIN display mode shows the lowest reading encountered since the meter was placed in the RECORD mode. In this mode the MIN and REC indicators will be on the LCD. AVG MODE: The AVG display mode shows a running average of the readings. In this mode the AVG and REC indicators will be on the LCD. REC only mode: In this mode the meter is still tracking the MIN, MAX, and AVG readings but only displaying the current readings. In this mode, only the REC display icon will be on. 4. To exit the RECORD mode press and hold the RECORD button until two beeps are heard. When the meter has successfully exited the RECORD mode, the MIN, MAX, AVG, and REC indicators will be off. 5. Note that the RECORD mode time limit is two (2) hours. Automatic Power OFF The meter has an Auto-Power OFF feature that preserves battery life by automatically turning the meter off after 20 minutes. Warning tones are sounded immediately before the meter switches off. When the meter is in the RECORD mode (explained in the MIN-MAX- AVG RECORD/RECALL section) the Auto Power OFF feature is disabled. To disable the Auto-Power OFF feature without having to access the RECORD/RECALL mode, follow the procedure below: 1. Turn the meter OFF 2. Press and hold the ON-OFF and HOLD keys simultaneously 3. Release the ON key while continuing to press the HOLD key 4. A letter n will appear on the LCD 5. Release the HOLD key 6. The meter s Auto-Power OFF feature has now been disabled. Keep in mind that the next time the meter is used, the Auto-Power OFF feature will be enabled. 4

PC Interface The meter is equipped with an RS-232c PC interface jack (3.5mm phono) for connection to a PC. The cable to connect the meter to the PC is included in the optional 407752 data acquisition kit. The kit includes Windows TM software that allows the user to store readings in a text file and display real-time measurements in a series of selectable formats. For more information or specific operating instructions, refer to the User Guide included with the 407752 kit or contact Extech Instruments. Battery Replacement The meter is powered by one 9V Battery. If the display does not switch on when the ON-OFF button is pressed, replace the battery using the procedure below. 1. Remove the Phillips head screw at the rear of the meter (refer to diagram) 2. Open the battery compartment by removing the compartment cover 3. Unsnap the old battery from the red and black wire connectors 4. Snap in the new battery and carefully dress the red and black wires so that they do not crimp or rest in the hinges of the compartment cover 5. Close the compartment cover 6. Tighten the Phillips head screw to secure the compartment 5

Specifications General Specifications Display Operating Temperature Operating Humidity Meter Power Battery life Auto Power OFF Weight Meter Dimensions Sensor Vane Diameter Accessories Dual LCD display: 0 to 9999 digits for Air Velocity and 0 to 1999 digits for Temperature readings 14 F to 122 F (-10 C to 50 C) 80% Relative Humidity (maximum) 9V battery 100 hours of continuous use Meter turns off after 20 minutes automatically 1.5 lb (680g) 7.20 x 2.99 x 1.77 (183 x 76 x 45 mm) 2.9 (70mm) 9V battery and hard carry case Range Specifications Range Resolution Accuracy (% Full Scale) 80-5900 ft/min 1 0.40 30.00 m/sec 0.01 0.9 68.0 mph ± 3% 0.8 58.0 knots 1.4 108.0 km/hr 0.1-10.0 to 50.0 o C ± 1C o 14.0 to 122.0 o F ± 2F o 0.1 o 6

Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Copyright 2003 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 7