SIMATIC PC-based controller

Similar documents
PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 412. Function. Programmable properties

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power losses

CPU 412H. Function. Parameterizable properties

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

Product type designation

General information. Display. Control elements. Supply voltage

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Multi Panel options. SIMATIC WinAC MP 2/169

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage

SIPLUS CPU 313C-2DP. Function

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. Supply voltage. Input current

General information. Supply voltage

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

Data sheet CPU 015PN (015-CEFPR01)

Data sheet CPU 315SN/PN ECO (315-4PN33)

WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

Data sheet CPU 015PN (015-CEFPR00)

Data sheet SLIO CPU 015PN (015-CEFPR01)

SIMATIC S Central processing units

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

CP ADVANCED. Function

Data sheet VIPA CPU 214PG (214-2BE03)

General information. Display. Supply voltage. Input current

Data sheet CPU 013C (013-CCF0R00)

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet VIPA CPU 214NET PG (214-2BT13)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet CPU 315SB/DPM (315-2AG12)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SIMATIC. Windows Automation Center RTX WinAC RTX Introduction 1. Product overview 2. Installation 3. Getting started 4

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

PC-based Control Open, flexible and reliable. Product Brief February 2004

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet CC 03, Commander Compact (603-1CC21)

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

S7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

1 What's new in SIMATIC imap STEP 7 AddOn?

Data sheet VIPA CPU 115DP (115-6BL22)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

SIMOTION P PC-based SIMOTION P350-3

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

1 1 Introduction Basics New Functions in DPV Example: Evaluation of Interrupt Information from OB 40 with SFB

SIMATIC NET. S7-CPs for Industrial Ethernet CP Manual Part B3S. Release 02/2006 C79000 G8976 C201 03

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

Short Description. Version

Transcription:

Siemens AG 2011 /2 /2 SIMATIC WinAC RTX /9 SIMATIC WinAC RTX F /16 SIMATIC WinAC ODK Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial Siemens ST 70 2011

SIMATIC WinAC RTX Siemens AG 2011 Overview SIMATIC WinAC RTX: Optimized for applications that require a high degree of flexibility and integration capability. The software solution for tasks that require hard deterministic behavior and high performance. With real-time expansion for assuring deterministic behavior for the control section. New with WinAC RTX 2010: Operation under Windows 7 Web server New PROFINET functions: - Isochronous mode - Shared Device - Media redundancy - IP configuration Technical specifications 6ES7 671-0RC0-0YA0 Product type designation SIMATIC WinAC RTX 2010 Product version Hardware product version - Firmware version V4.6 associated programming package STEP7 as of V5.5 + HW update / imap V3.0 SP1 Memory Work memory integrated (for program) 4 Mbyte; Adjustable; depends on n Paged Memory Pool integrated (for data) 4 Mbyte; Adjustable; depends on n Paged Memory Pool Load memory integrated RAM, CPU-blocks DB Number, Size, FB Number, Size, FC Number, Size, OB Number, Size, Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Number of delay alarm OBs 1; OB 20 Mbyte; Adjustable; depends on n Paged Memory Pool 65 535; Limited only by RAM set for data 65 536; Limited only by RAM set for code 65 536; Limited only by RAM set for code Limited only by RAM set for code 6ES7 671-0RC0-0YA0 OB Number of time alarm OBs 9; OB 30-3 Number of process alarm OBs 1; OB 40 Number of ODK OBs 3; OB 52-54 Number of DPV1 alarm OBs 3; OB 55-57 Number isochronous mode OBs 2; OB 61-62 Number of startup OBs 2; OB 100, 102 Number of asynchronous error 7; OB 0, 2-5, 6, OBs Number of synchronous error 2; OB 121, 122 OBs Nesting depth per priority class 24 additional within an error OB 24 CPU processing times for bit operations, min. 0.004 μs; typ. for fixed point arithmetic, min. 0.003 μs; typ. for floating point arithmetic, min. 0.004 μs; typ. Reference platform Pentium IV, 2.4 GHz Counters, timers and their retentivity S7 counter Number 204 Retentivity - can be set - lower limit 0 - upper limit 2047 -preset Counting range - can be set - lower limit 0 - upper limit 999 IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) /2 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX S7 times Number 204 Retentivity - can be set - lower limit 0 -upperlimit 2047 - preset 0 Time range - lower limit 10 ms -upperlimit 9990s IEC timer present Type Number Data areas and their retentivity Retentivity without UPS and PS Extension Board SFB Unlimited (limited only by RAM capacity) 12 KB with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request all data Retentivity with UPS Flag Number, 16 Kibyte of which retentive MB 0 to MB 1633 Retentivity preset MB 0 to MB 15 Number of clock memories Data blocks Number, Size, Retentivity adjustable Retentivity preset Local data adjustable, preset 32 Kibyte per priority class, 61 440 byte Address area I/O address area overall 16 Kibyte Outputs 16 Kibyte of which, distributed - DP interface, inputs 16 Kibyte - DP interface, outputs 16 Kibyte - PN interface, inputs 16 Kibyte - PN interface, outputs 16 Kibyte Process image Inputs, adjustable Kibyte Outputs, adjustable Kibyte Inputs, default 512 byte Outputs, default 512 byte Subprocess images Number of subprocess images, 15 Digital channels Inputs 12 000 Outputs 12 000 6ES7 671-0RC0-0YA0 Limited only by available retentive memory (NVRAM, or file storage) ; via non-retain property on DB 6ES7 671-0RC0-0YA0 Analog channels Inputs 000 Outputs 000 Hardware configuration Submodules Number of submodules, max 4 of which PROFIBUS, 4; Supported interfaces: see 1st and 2nd interface of which Industrial Ethernet, 1; Supported interfaces: see 3rd and 4th interface Number of operable FMs and CPs (recommended) FM FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 CP, point-to-point 2; CP 340, CP 341 distributed CP, LAN Over PC CP Time Clock Hardware clock (real-time clock) battery-backed and synchronizable Runtime meter Number Clock synchronization to PC-CP, slave on Ethernet via NTP S7 message functions Number of login stations for 62 message functions, SCAN procedure Process diagnostic messages ; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ simultaneously active Alarm-S blocks, Alarm -blocks Number of instances for alarm and S7 communication blocks, Process control messages Test commissioning functions Status/control Status/control variable Forcing Forcing Status block Single step 20;ofatotalof20forall 4000 Number of breakpoints 20 Diagnostic buffer present Number of entries, 3200 - can be set -preset 120 Siemens ST 70 2011 /3

SIMATIC WinAC RTX Siemens AG 2011 6ES7 671-0RC0-0YA0 Communication functions PG/OP communication Data record routing ; Only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC Routing Global data communication S7 basic communication S7 communication as server as client User data per job, ; When using BSEND/ USEND Web server Number of HTTP clients 2 User-defined websites Open IE communication TCP/IP - Number of connections, 32 - Data length for connection t type 01H, - Data length for connection 65 534 byte type 11H, - Data length, 65 534 byte ISO-on-TCP (RFC1006) - Number of connections, 32 - Data length, 65 534 byte UDP - Number of connections, 32 - Data length, 1472byte Number of connections overall 96 usable for PG communication - reserved for PG communication 1 usable for OP communication - reserved for OP communication 1 PROFINET CBA (at set setpoint communication load) Setpoint for the CPU 20 % communication load Number of remote 64 interconnection partners Number of functions, master/ 30 slave Total of all Master/Slave 1000 connections Datalengthofallincoming 600byte connections master/slave, Data length of all outgoing 600byte connections master/slave, Number of device-internal and 500 PROFIBUS interconnections 6ES7 671-0RC0-0YA0 PROFINET CBA (at set setpoint communication load) Datalengthofdevice-internal 4000byte und PROFIBUS interconnections, Data length per connection, 1400byte Remote interconnections with acyclic transmission - Sampling frequency: 500 ms Sampling time, min. - Number of incoming interconnections 100 - Number of outgoing interconnections 100 - Data length of all incoming 2000byte interconnections, - Data length of all outgoing 2000byte interconnections, - Data length per connection, 1400byte Remote interconnections with cyclic transmission - Transmission frequency: 10 ms Transmission interval, min. - Number of incoming interconnections 200 - Number of outgoing interconnections 200 - Data length of all incoming 400byte interconnections, - Data length of all outgoing 400byte interconnections, - Data length per connection, 250 byte HMI variables via PROFINET (acyclic) - Number of stations that can 3 log on for HMI variables (PN OPC/iMap) - HMI variable updating 500 ms - Number of HMI variables 200 - Data length of all HMI 2000byte variables, PROFIBUS proxy functionality - - Number of linked PROFIBUS 16 devices - Data length per connection, 240 byte; Slave-dependent 1st interface Type of interface CP 5611-A2, CP 5621, integrated PB interface of the SIMATIC PC Max. no. of simultaneously 1 operable CPs Physics RS 45 / PROFIBUS Isolated Power supply to interface does not exist (15to30VDC), Number of connection resources Functionality MPI DP master DP slave /4 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX DP master Number of connections, - PG/OP communication -Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support ; Only in conjunction with isochronous mode - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slaveto-slave communication) - DPV0 - DPV1 Transmission rate, 12 Mbit/s Number of DP slaves, 64 Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte 2nd interface Type of interface Max. no. of simultaneously operable CPs Physics Isolated Functionality MPI DP master DP slave 6ES7 671-0RC0-0YA0 CP 5613, CP 5613-A2, CP 5603 4 RS 45 / PROFIBUS DP master Number of connections, 50 - PG/OP communication -Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support ; Only in conjunction with isochronous mode - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves 6ES7 671-0RC0-0YA0 DP master - Direct data exchange (slaveto-slave communication) - DPV0 - DPV1 Transmission rate, 12 Mbit/s Number of DP slaves, 125 Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte 3rd interface Type of interface PROFINET Max. no. of simultaneously operable CPs 1; Intel Pro/1000 (Intel 2571EB, 2573L, 2574L, 2541PI; non-shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, x7b, IPC4x7C, IPC6x7C, IPCx7C Ethernet Physics Isolated Integrated switch Number of ports 1 automatic detection of ; 10/100 Mbit/s transmission speed Autonegotiation Autocrossing Media redundancy Functionality PROFINET IO Controller PROFINET IO Device PROFINET CBA Open IE communication PROFINET IO Controller - PG/OP communication -Routing ; S7 routing - S7 communication - Isochronous mode - Open IE communication Transmission rate, min. 100 Mbit/s Transmission rate, 100 Mbit/s Max. number of connectable 12 IO devices for RT - of which in line, 12 Siemens ST 70 2011 /5

SIMATIC WinAC RTX Siemens AG 2011 6ES7 671-0RC0-0YA0 PROFINET IO Controller IRT, Prioritized startup - Number of IO Devices, 32 Activation/deactivation of IO Devices - Number of IO Devices that can be simultaneously activated/deactivated, IO Devices changing during operation (partner ports), Device replacement without swap medium Send clock times 1ms Updating time 1-512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data) Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per address area, 2kbyte - User data consistency, 256 byte SIMATIC communication PG/OP communication S7 routing S7 communication Number of connections, 16 Open IE communication Open IE communication, Number of connections, 32 Local port numbers used at 0, 20, 21, 23, 25, 0, 102, the system end 135, 161, 00, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Keep-alive function, 4th interface Type of interface PROFINET Max. no. of simultaneously operable CPs 1; CP 1616 (HW release or above), CP 1604 (HW release 7 or higher), integrated PN interface of SIMATIC PC and S7-mEC Ethernet Physics Isolated Integrated switch Number of ports 3 automatic detection of ; 10/100 Mbit/s transmission speed Autonegotiation Autocrossing Media redundancy Switchovertimeonlinebreak, typically Number of stations in the ring, 200 ms 50 6ES7 671-0RC0-0YA0 Change of IP address at runtime, Number of connection resources 32 Functionality PROFINET IO Controller PROFINET IO device PROFINET CBA Open IE communication Web server PROFINET IO Controller - PG/OP communication -Routing ; S7 routing - S7 communication - Isochronous mode - Open IE communication Transmission rate, min. 100 Mbit/s Transmission rate, 100 Mbit/s Max. number of connectable 256 IO Devices for RT - of which in line, 256 Number of IO Devices with 64 IRT and the option "high flexibility" - of which in line, 32 Number of IO Devices with 64 IRT and the option "high performance", - of which in line, 32 IRT, Prioritized startup - Number of IO Devices, 32 Activation/deactivation of IO Devices - Number of IO Devices that can be simultaneously activated/deactivated, IO Devices changing during operation (partner ports), Device replacement without swap medium Send clock times 250 μs, 500 μs, 1 ms Updating time 0.25...512 depending on the send cycle Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per address area, 2kbyte - User data consistency, 256 byte SIMATIC communication PG/OP communication S7 routing S7 communication Number of connections, 32 Open IE communication Open IE communication, Number of connections, 32 Local port numbers used at the system end 0, 20, 21, 25, 0, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 /6 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX 6ES7 671-0RC0-0YA0 6ES7 671-0RC0-0YA0 Isochronous mode Isochronous mode Number of DP masters with isochronous mode User data per isochronous slave, Equidistance Shortest clock pulse 2 12 byte 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image Programming Programming language STEP7 ; As of V5.5, Engineering Tools (optional) LAD FBD STL SCL CFC GRAPH HiGraph Nesting levels Know-how protection User program protection/ password protection Software libraries Easy Motion Control Software redundancy ; As of V1.2, only operation of WinAC RTX with WinAC RTX Open Development interfaces CCX (Custom Code Extension) ; WinAC ODK V4.2 or higher SMX ; WinAC ODK V4.2 (Shared Memory Extension) or higher -Inputs 4Kibyte -Outputs 4Kibyte CMI (Controller Management Interface) Number of simultaneously active DPSYC_FR D_ACT_DP RD_REC ; WinAC ODK V4.2 or higher 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all Number of simultaneously active WR_REC WR_PARM PARM_MOD WR_DPARM DPNRM_DG RDSYSST Number of simultaneously active SFBs RD_REC WR_REC Hardware requirements Hardware required Required memory on hard disk, min. Work memory, min. Processor Multi- system Hyper-threading Operating systems Operating system Windows NT 4.0 Windows 2000 Windows XP Windows XP embedded - Supported HAL types under Windows XP Windows embedded Standard 7 Windows 7 Windows Vista Dimensions and weight Weight Weight, approx. 20;ofatotalof20forall 20;ofatotalof20forall 20;ofatotalof20forall 20;ofatotalof20forall 20;ofatotalof20forall 20;ofatotalof20forall 20;ofatotalof20forallSFBs 20;ofatotalof20forallSFBs PC with color monitor, keyboard, mouse or pointing device for Windows 100 Mbyte 1Gbyte Intel Celeron M, 900 MHz or compatible ; Dual Pentium, CoreDuo, Core2Duo or compatible ; Professional, SP2 and SP3 ; With the delivery image of the SIMATIC PC ACPI uni PC, ACPI multi PC, MPS multi PC ; Professional, Enterprise, Ultimate (only 32 bit) 100 g; with packaging Siemens ST 70 2011 /7

SIMATIC WinAC RTX Siemens AG 2011 Ordering data Order. Order. SIMATIC WinAC RTX 2010 J 6ES7 671-0RC0-0YA0 CP 5623 communication C 6GK1562-3AA00 Software PLC for PC-based automation tasks with stringent PCI Express x1 card (32 bit) for deterministic requirements; connection to PROFIBUS incl. PROFIBUS and PROFINET; DP-Base software with NCM PC; CD-ROM with electronic DP-RAM interface for DP master documentation d, e, f; or DP slave, incl. PG and FDL single license, executable under protocols; single license for Windows XP SP2 and SP3 as well 1 installation, runtime software, as Windows 7 (32 bit) software and electronic manual on CD-ROM, Class A, for SIMATIC WinAC RTX 2010 J 6ES7 671-0RC0-0YE0 operating system support see Upgrade SIMATIC NET software; For upgrading from basic/rtx German/English V3.x, V4.0, V4.1 2005, 200 and CP 1616 communication 6GK1 161-6AA01 2009; single license, executable under Windows XP SP2 and SP3 and PCI Card (32 bit; 3.3/5 V universal Windows 7 (32 bit) key) with ASIC ERTEC 400 for connecting PCs to PROFINET IO CP 5611 A2 communication 6GK1 561-1AA01 with 4-port real-time switch (RJ45); incl. IO-Base software for PCI card (32 bit) for connection of PROFINET IO controller a programming device or PC (RT operation) and NCM PC; to PROFIBUS single license for one installation, runtime software, software and CP 5621 communication electronic manual on CD-ROM, Class A, for 32 bit Windows XP PCI Express x1 card (32 bit) for C 6GK1 562-1AA00 Professional; connection of a programming German/English device or PC to PROFIBUS CP 1604 Microbox Package 6GK1 160-4AU00 PCI Express x1 card (32 bit) C 6GK1 562-1AM00 CP 5621 and MPI cable, 5 m Package for implementing the CP 1604 in the SIMATIC Microbox CP 5603 Microbox Package I 6GK1 560-3AU00 PC; comprising the CP 1604, Comprising CP 5603 module and connection board, power supply Microbox expansion frame and expansion frame for Microbox PC; for use with CP 5613 A2 communication 6GK1 561-3AA01 Development Kit DK-16xx PN IO; NCM PC PCI card (32 bit; 3.3 V/5 V) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocol; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows 2000 Professional/ Server, Windows XP Professional, German/English C: Subject to export regulations AL: N and ECCN: 5D002ENCU I: Subject to export regulations AL: N and ECCN: EAR99H J: Subject to export regulations AL: N and ECCN: EAR99S / Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX F Overview SIMATIC WinAC RTX F: Optimized for applications that demand a high degree of flexibility and integration capability and that must also satisfy safety requirements up to SIL 3 (IEC 6150). The software solution for tasks that require hard deterministic behavior and high performance. With real-time expansion for assuring deterministic behavior for the control section. Distributed I/O can be connected over PROFIBUS and/or PROFINET, also safety-related over PROFIsafe. Technical specifications 6ES7 671-1RC0-0YA0 Product type designation SIMATIC WinAC RTX F 2010 Product version Hardware product version - Firmware version V4.6 associated programming package STEP7 as of V5.5 + HW update / imap V3.0 SP1 / option package S7 Distributed Safety V5.4 + SP5 / S7 F Configuration Pack V5.5 + SP6 + HF1 Memory Work memory integrated (for program) 4 Mbyte; Adjustable; depends on n Paged Memory Pool integrated (for data) 4 Mbyte; Adjustable; depends on n Paged Memory Pool Load memory integrated RAM, CPU-blocks DB Number, Size, FB Number, Size, FC Number, Size, OB Number, Size, Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Adjustable; depends on n Paged Memory Pool 65 535; Limited only by RAM set for data 65 536; Limited only by RAM set for code 65 536; Limited only by RAM set for code Limited only by RAM set for code 6ES7 671-1RC0-0YA0 OB Number of delay alarm OBs 1; OB 20 Number of time alarm OBs 9; OB 30-3 Number of process alarm OBs 1; OB 40 Number of ODK OBs 3; OB 52-54 Number of DPV1 alarm OBs 3; OB 55-57 Number isochronous mode OBs 2; OB 61-62 Number of startup OBs 2; OB 100, 102 Number of asynchronous error 7; OB 0, 2-5, 6, OBs Number of synchronous error OBs 2; OB 121, 122 Nesting depth per priority class 24 additional within an error OB 24 CPU processing times for bit operations, min. 0.004 μs; typ. for fixed point arithmetic, min. 0.003 μs; typ. for floating point arithmetic, min. 0.004 μs; typ. Reference platform Pentium IV, 2.4 GHz Counters, timers and their retentivity S7 counter Number 204 Retentivity - adjustable -lower limit 0 - upper limit 2047 -preset Counting range - adjustable -lower limit 0 - upper limit 999 IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) Siemens ST 70 2011 /9

SIMATIC WinAC RTX F Siemens AG 2011 S7 times Number 204 Retentivity - adjustable -lower limit 0 - upper limit 2047 - preset 0 Time range -lower limit 10 ms - upper limit 9990s IEC timer present Type Number Data areas and their retentivity Retentivity without UPS and PS Extension Board SFB Unlimited (limited only by RAM capacity) 12 KB with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request all data Retentivity with UPS Flag Number, 16 Kibyte of which retentive MB 0 to MB 1633 Retentivity preset MB 0 to MB 15 Number of clock memories Data blocks Number, Size, Retentivity adjustable Retentivity preset Local data adjustable, preset 32 Kibyte per priority class, 61 440 byte Address area I/O address area overall 16 Kibyte Outputs 16 Kibyte of which, distributed - DP interface, inputs 16 Kibyte - DP interface, outputs 16 Kibyte - PN interface, inputs 16 Kibyte - PN interface, outputs 16 Kibyte Process image Inputs, adjustable Kibyte Outputs, adjustable Kibyte Inputs, default 512 byte Outputs, default 512 byte Subprocess images Number of subprocess images, 15 Digital channels Inputs 12 000 Outputs 12 000 6ES7 671-1RC0-0YA0 Limited only by available retentive memory (NVRAM, or file storage) ; via non-retain property on DB 6ES7 671-1RC0-0YA0 Analog channels Inputs 000 Outputs 000 Hardware configuration Submodules Number of submodules, max 4 of which PROFIBUS, 4; Supported interfaces: see 1st and 2nd interface of which Industrial Ethernet, 1; Supported interfaces: see 3rd and 4th interface Number of operable FMs and CPs (recommended) FM CP, point-to-point CP, LAN Time Clock Hardware clock (real-time clock) battery-backed and synchronizable 4; FM distributed: FM 350-1, FM 350-2, FM 351, FM 352 / FM 352-5, FM 353, FM 354, FM 355, FM 355-2 2; CP 340, CP 341 distributed Over PC CP Runtime meter Number Clock synchronization to PC-CP, slave on Ethernet via NTP S7 message functions Number of login stations for 62 message functions, SCAN procedure Process diagnostic messages ; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ simultaneously active Alarm-S 20; of a total of 20 for all blocks, Alarm -blocks Number of instances for alarm 4000 and S7 communication blocks, Process control messages Test commissioning functions Status/control Status/control variable Forcing Forcing Status block Single step Number of breakpoints 20 Diagnostic buffer present Number of entries, 3200 - adjustable -preset 120 /10 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX F 6ES7 671-1RC0-0YA0 Communication functions PG/OP communication Data record routing ; Only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC Routing Global data communication S7 basic communication S7 communication as server as client User data per job, ; Depends on which block is used: BSEND/USEND or PUT/GET Web server Supported Number of HTTP clients 2 User-defined websites Open IE communication TCP/IP - Number of connections, 32 - Data length for connection type t 01H, - Data length, 65 534 byte ISO-on-TCP (RFC1006) - Number of connections, 32 - Data length, 65 534 byte UDP - Number of connections, 32 - Data length, 1472byte Number of connections overall 96 usable for PG communication - reserved for PG communication 1 usable for OP communication - reserved for OP communication 1 PROFINET CBA (at set setpoint communication load) Setpoint for the CPU communication load 20 % Number of remote interconnection 64 partners Number of functions, master/slave 30 Total of all Master/Slave connections 1000 Data length of all incoming 600byte connections master/slave, Data length of all outgoing 600byte connections master/slave, Number of device-internal and 500 PROFIBUS interconnections Data length of device-internal und 4000byte PROFIBUS interconnections, Data length per connection, 1400byte 6ES7 671-1RC0-0YA0 PROFINET CBA (at set setpoint communication load) Remote interconnections with acyclic transmission - Sampling frequency: Sampling 500 ms time, min. - Number of incoming interconnections 100 - Number of outgoing interconnections 100 - Data length of all incoming interconnections, 2000byte - Data length of all outgoing interconnections, 2000byte - Data length per connection, 1400byte Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. 10 ms - Number of incoming interconnections 200 - Number of outgoing interconnections 200 - Data length of all incoming interconnections, 400byte - Data length of all outgoing interconnections, 400byte - Data length per connection, 250 byte HMI variables via PROFINET (acyclic) - Number of stations that can log 3 on for HMI variables (PN OPC/ imap) - HMI variable updating 500 ms - Number of HMI variables 200 - Data length of all HMI variables, 2000byte PROFIBUS proxy functionality - - Number of linked PROFIBUS 16 devices - Data length per connection, 240 byte; Slave-dependent 1st interface Type of interface Max. no. of simultaneously operable CPs Physics Isolated Power supply to interface (15 to 30 V DC), Number of connection resources Functionality MPI DP master DP slave CP 5611-A2, CP 5621, integrated PB interface of the SIMATIC PC 1 RS 45 / PROFIBUS does not exist Siemens ST 70 2011 /11

SIMATIC WinAC RTX F Siemens AG 2011 6ES7 671-1RC0-0YA0 DP master Number of connections, - PG/OP communication -Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support ; Only in conjunction with isochronous mode - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-toslave communication) - DPV0 - DPV1 Transmission rate, 12 Mbit/s Number of DP slaves, 64 Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte 2nd interface Type of interface CP 5613, CP 5613-A2, CP 5603, CP 5623 Max. no. of simultaneously operable 4 CPs Physics RS 45 / PROFIBUS Isolated Functionality MPI DP master DP slave DP master Number of connections, 50 - PG/OP communication -Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support ; Only in conjunction with isochronous mode - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-toslave communication) - DPV0 - DPV1 6ES7 671-1RC0-0YA0 DP master Transmission rate, 12 Mbit/s Number of DP slaves, 125 Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte 3rd interface Type of interface PROFINET Max. no. of simultaneously operable CPs 1; Intel Pro/1000 (Intel 2571EB, 2573L, 2574L, 2541PI; nonshared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, x7b, IPC4x7C, IPC6x7C, IPCx7C Ethernet Physics Isolated Integrated switch Number of ports 1 Automatic detection of transmission ; 10/100 Mbit/s speed Autonegotiation Autocrossing Media redundancy Functionality PROFINET IO controller PROFINET IO device PROFINET CBA Open IE communication PROFINET IO controller - PG/OP communication -Routing ; S7 routing - S7 communication - Isochronous mode - Open IE communication Transmission rate, min. 100 Mbit/s Transmission rate, 100 Mbit/s Number of connectable 12 IO devices, Number of connectable 12 IO devices for RT, - of which in line, 12 IRT, Prioritized startup - Number of IO devices, 32 Activation/deactivation of IO devices - Number of IO devices that can be simultaneously activated/ deactivated, /12 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX F PROFINET IO controller IO devices changing during operation (partner ports), Device replacement without swap medium Send clock times Updating time Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per address area, 2Kibyte - User data consistency, 256 byte SIMATIC communication PG/OP communication S7 routing S7 communication Number of connections, 16 Open IE communication Open IE communication, Number of connections, 32 Local port numbers used at the system end 1 ms 1-512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data) 0, 20, 21, 23, 25, 0, 102, 135, 161, 00, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Keep-alive function, 4th interface Type of interface PROFINET Max. no. of simultaneously operable 1; CP 1616 (HW release or CPs above), CP 1604 (HW release 7 or higher), integrated PN interface of SIMATIC PC and S7-mEC Physics Ethernet Isolated Integrated switch Number of ports 3 Automatic detection of transmission ; 10/100 Mbit/s speed Autonegotiation Autocrossing Media redundancy Switchover time on line break, 200 ms typically Number of stations in the ring, 50 Change of IP address at runtime, Number of connection resources 32 Functionality PROFINET IO controller PROFINET IO device PROFINET CBA Open IE communication Web server 6ES7 671-1RC0-0YA0 6ES7 671-1RC0-0YA0 PROFINET IO controller - PG/OP communication -Routing ; S7 routing - S7 communication - Isochronous mode - Open IE communication Transmission rate, min. 100 Mbit/s Transmission rate, 100 Mbit/s Number of connectable 256 IO devices, Number of connectable 256 IO devices for RT, - of which in line, 256 Number of IO devices with IRT and 64 the option "high flexibility" - of which in line, 32 Number of IO devices with IRT and 64 the option "high performance", - of which in line, 64 IRT, Shared device, Prioritized startup - Number of IO devices, 32 Activation/deactivation of IO devices - Number of IO devices that can be simultaneously activated/ deactivated, IO devices changing during operation (partner ports), Device replacement without swap medium Send clock times 250 μs, 500 μs, 1 ms Updating time 0.25...512 depending on the send cycle Address area - Inputs, 16 Kibyte - Outputs, 16 Kibyte User data per address area, 2Kibyte - User data consistency, 256 byte SIMATIC communication PG/OP communication S7 routing S7 communication Number of connections, 32 Open IE communication Open IE communication, Number of connections, 32 Local port numbers used at the system end Isochronous mode Isochronous mode Number of DP masters with isochronous mode User data per isochronous slave, 0, 20, 21, 25, 0, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 2 12 byte Siemens ST 70 2011 /13

SIMATIC WinAC RTX F Siemens AG 2011 6ES7 671-1RC0-0YA0 6ES7 671-1RC0-0YA0 Equidistance Shortest clock pulse Programming Programming language STEP 7 LAD FBD STL SCL CFC GRAPH HiGraph Nesting levels Know-how protection User program protection/ password protection Block encryption Software libraries Easy Motion Control Software redundancy Open Development interfaces CCX (Custom Code Extension) SMX (Shared Memory Extension) -Inputs -Outputs CMI (Controller Management Interface) Number of simultaneously active DPSYC_FR D_ACT_DP RD_REC WR_REC WR_PARM PARM_MOD WR_DPARM DPNRM_DG RDSYSST 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image ; As of V5.5 + HW update/s7 F Configuration Pack V5.5 + SP6 + HF1/option package S7 Distributed Safety V5.4 + SP5 or higher ; As of V1.2, only for operation of WinAC RTX (F) with WinAC RTX (F) ; WinAC ODK V4.2 or higher ; WinAC ODK V4.2 or higher 4Kibyte 4Kibyte ; WinAC ODK V4.2 or higher 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all 20; of a total of 20 for all Number of simultaneously active SFBs RD_REC WR_REC Hardware requirements Hardware required Required memory on hard disk, min. Work memory, min. Processor Multi- system Hyper-threading Operating systems Operating system Windows NT 4.0 Windows 2000 Windows XP Windows XP embedded - Supported HAL types under Windows XP Windows embedded Standard 7 Windows 7 Windows Vista Dimensions and weight Weight Weight, approx. 20; of a total of 20 for all SFBs 20; of a total of 20 for all SFBs PC with color monitor, keyboard, mouse or pointing device for Windows 100 Mbyte 1Gbyte Intel Celeron M 900 MHz or compatible (older PC systems with Programmable Interrupt Controllers (PIC) are not suitable for WinAC RTX F 2010.) ; Professional, SP2 and SP3 ; With the delivery image of the SIMATIC PC ACPI uni PC, ACPI multi PC, MPS multi PC ; Professional, Enterprise, Ultimate (only 32 bit) 100 g; with packaging /14 Siemens ST 70 2011

Siemens AG 2011 SIMATIC WinAC RTX F Ordering data Order. Order. SIMATIC WinAC RTX F 2010 J 6ES7 671-1RC0-0YA0 CP 5623 communication C 6GK1 562-3AA00 SIMATIC WinAC RTX F 2010 I 6ES7 671-1RC0-0YE0 upgrade CP 5611 A2 communication 6GK1 561-1AA01 PCI card (32 bit) for connection of a programming device or PC to PROFIBUS CP 5621 communication PCI Express x1 card (32 bit) for C 6GK1 562-1AA00 connection of a programming device or PC to PROFIBUS PCI Express x1 card (32 bit) C 6GK1 562-1AM00 CP 5621 and MPI cable, 5 m CP 5603 Microbox Package I 6GK1 560-3AU00 Comprising CP 5603 module and Microbox expansion frame CP 5613 A2 communication 6GK1 561-3AA01 PCI card (32 bit; 3.3 V/5 V) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocol; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows 2000 Professional/ Server, Windows XP Professional, German/English PCI Express x1 card (32 bit) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master or DP slave, incl. PG and FDL protocols; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English CP 1616 communication PCI Card (32 bit; 3.3/5 V universal key) with ASIC ERTEC 400 for connecting PCs to PROFINET IO with 4-port real-time switch (RJ45); incl. IO-Base software for PROFINET IO controller (RT operation) and NCM PC; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows XP Professional; German/English CP 1604 Microbox Package Package for implementing the CP 1604 in the SIMATIC Microbox PC; comprising the CP 1604, connection board, power supply and expansion frame for Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC 6GK1 161-6AA01 6GK1 160-4AU00 C: Subject to export regulations AL: N and ECCN: 5D002ENCU I: Subject to export regulations AL: N and ECCN: EAR99H J: Subject to export regulations AL: N and ECCN: EAR99S Siemens ST 70 2011 /15

SIMATIC WinAC ODK Siemens AG 2011 Overview SIMATIC WinAC software PLCs support powerful interfaces which permit close meshing of the control task with PC-based applications. WinAC ODK allows the user to develop applications or to integrate already existing applications into the control task. New with WinAC ODK V4.2: CCX interface: - New SFB 65003 for asynchronous execution of ODK applications - Expansion of data access functions - Creation of Windows DLL with C# and VB SMX interface: - Access to the Shared Memory interface under IntervalZero RTX - Expansion of data access functions - Creation of Windows applications with C# and VB Supports MS Visual Studio 2005 and 200 (under Windows) Technical specifications 6ES7 06-1CC03-0BA0 Product type designation SIMATIC WinAC ODK V4.2 Programming Open Development interfaces CCX (Custom Code Extension) SMX (Shared Memory Extension) CMI (Controller Management Interface) Hardware requirements Hardware required Required memory on hard disk, min. Work memory, min. Processor Software requirement Software required Operating systems Operating system Windows XP Dimensions and weight Weight Weight, approx. ; WinAC RTX 200 (V4.4) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher,.net 2003, 2005, 200; Microsoft Visual Basic 2005, 200; Microsoft Visual C# 2005, 200 ; WinAC RTX 200 (V4.4) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher,.net 2003, 2005, 200; Microsoft Visual Basic 2005, 200; Microsoft Visual C# 2005, 200 ; WinAC RTX 2005 SP2 (V4.3) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher,.net 2003, 2005, 200; Microsoft Visual Basic V6.0 SP5 or higher,.net 2003, 2005, 200; Microsoft Visual C#.net 2003, 2005, 200 PC with color monitor, keyboard, mouse or pointing device for Windows 30 Mbyte 512 Mbyte Intel Pentium 00 MHz Microsoft Visual Developer Studio, for details see interfaces; CCX and SMX realtime applications in addition: IntervalZero SDK V.1 (SDK version must match the WinAC RTX version) ; Professional, SP2 and SP3 200 g Ordering data Order. SIMATIC WinAC ODK V4.2 for integration of C/C++ code in WinAC PLCs, executable under Windows XP SP2 or SP3; CD- ROM with electronic documentation Single license J 6ES7 06-1CC03-0BA0 J: Subject to export regulations AL: N and ECCN: EAR99S /16 Siemens ST 70 2011