Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Similar documents
USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

These specifications apply to the 1 m and 3 m TriaxM-TriaxM. it in a manner not described in this document.

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

1- or 2-Port, High-Speed/FD, USB CAN Interface Device

ATCA Contents. Definitions SPECIFICATIONS. FPGA Module for ATCA

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

NI 6581/6581B Specifications

illustrate the performance of a representative module.

NI PXIe-7971R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

NI PXIe-7976R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

Note Using the PXIe-7915 in a manner not described in this document might impair the protection the PXIe-7915 provides.

Compact Vision System with USB3 Vision and Reconfigurable I/O

1 Gbps, 20 Channel, LVDS Digital I/O Adapter Module

Power and I/O Accessory

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Thermal Kit for NI sbrio-9607/9627/9637

NI 9402 DATASHEET. 4 DIO, LVTTL, Bidirectional, 55 ns. BNC connectivity CompactDAQ counter compatibility Individually configurable channel directions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

C SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISON

This document contains specifications for the PXIe-1084 chassis.

This document provides installation, configuration, and reference information for the PXIe-8301 remote control module.

NI 9220 DATASHEET. 16 AI, ±10 V, 16 Bit, 100 ks/s/ch Simultaneous

NI 9223 Datasheet DATASHEET. 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

NI 9201 DATASHEET. 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate

NI 9266 Datasheet DATASHEET. 8 AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI 9269 DATASHEET. 4 AO, ±10 V, ±40 V Stacked, 16 Bit, 100 ks/s/ch Simultaneous

NI crio Processor. Operating System SPECIFICATIONS. Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

NI PXI-2567 Specifications

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

NI cdaq Processor. Operating System. Network/Ethernet Port DEVICE SPECIFICATIONS. NI CompactDAQ Four-Slot Controller

GETTING STARTED GUIDE NI Synchronization Module

PCI Express, 16-Bit, 32-Channel, 1 MS/s Analog Output Device

NI cdaq Processor. Operating System. Network/Ethernet Port DEVICE SPECIFICATIONS. NI CompactDAQ Eight-Slot Controller

NI cdaq Processor. Operating System. Network/Ethernet Port DEVICE SPECIFICATIONS. NI CompactDAQ Eight-Slot Controller

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

GETTING STARTED GUIDE NI Port, RS232 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI 9775 DATASHEET. 4-Ch, ±10 V, 20 MS/s, 14-Bit Digitizer

GETTING STARTED GUIDE NI Port, RS485/RS422 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

GETTING STARTED GUIDE TRC NI-XNET LIN Transceiver Cable. This document explains how to connect the TRC-8546.

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Note Using the PXIe-5764 in a manner not described in this document might impair the protection the PXIe-5764 provides.

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI sbrio Processor SPECIFICATIONS. Single-Board RIO OEM Devices

1.33 GHz Dual-Core CPU, 1 GB DRAM, 4 GB Storage, Artix-7 A50T FPGA, 4-Slot CompactRIO Controller

GETTING STARTED GUIDE TRC NI-XNET CAN HS/FD Transceiver Cable. This document explains how to connect the TRC-8542.

Electrical. SPECIFICATIONS SH Cable

SCC-RLY01 Relay Module

SCC-AO10 Isolated Analog Output Module

1.60 GHz Quad-Core CPU, 4 GB DRAM, 16 GB Storage, Kintex-7 325T FPGA, 8-Slot CompactRIO Controller

1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller

1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, Kintex-7 70T FPGA, Extended Temperature, 4-Slot CompactRIO Controller

1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, Kintex-7 70T FPGA, 8-Slot CompactRIO Controller

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

1.60 GHz Quad-Core CPU, 4 GB DRAM, 16 GB Storage, Kintex-7 325T FPGA, 8-Slot CompactRIO Controller

SH Cable Specifications

This document contains installation instructions and signal information for the NI 6581/6581B.

Intelligent Real-Time Embedded Controller for CompactRIO

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

NI crio-9012/9014. Safety Guidelines for Hazardous Locations USER MANUAL AND SPECIFICATIONS. Intelligent Real-Time Embedded Controllers for CompactRIO

NI 6521 Specifications

NI Safety Guidelines USER MANUAL AND SPECIFICATIONS. Ethernet Expansion Chassis for C Series Modules

NI PXI-1042 Series Power Supply Shuttle

PXIe Contents. Electromagnetic Compatibility Guidelines USER MANUAL. Dual-Port 10 Gigabit Ethernet Peripheral Module

NI sbrio Processor SPECIFICATIONS. Single-Board RIO OEM Devices

NI sbrio Processor SPECIFICATIONS. Single-Board RIO OEM Devices

Reconfigurable Embedded Chassis with Integrated Intelligent Real- Time Controller for CompactRIO

NI Serial Hardware Specifications Guide

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

Low-Cost Multifunction DAQ for USB

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI 6251 M Series Data Acquisition:16 AI, 1.25 MS/s, 24 DIO, 2 AO

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

SCXI -1313A Terminal Block

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

Reconfigurable Embedded Chassis with Integrated Intelligent Real- Time Controller for CompactRIO SAFE MODE CONSOLE OUT IP RESET NO APP USER1 NO FPGA

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Low-Cost Digital I/O Device for USB

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

General Purpose Inverter Controller RIO Mezzanine Card. Figure 1. NI 9683

The following figure shows an example of a properly connected NI FlexRIO device. Figure 1. NI FlexRIO Device

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

Transcription:

SPECIFICATIONS USB-6501 24-Channel, 8.5 ma, Digital I/O Device Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. The following characteristic specifications describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty. Typical specifications describe the performance met by a majority of models. Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing. Specifications are Typical unless otherwise noted. Conditions Specifications are valid at 25 C unless otherwise noted. All voltages are relative to COM unless otherwise noted. Digital I/O Number of lines P0.<0..7> 8 P1.<0..7> 8 P2.<0..7> 8 Direction control Output driver type Input or output, software-selectable Active drive (push-pull) or open collector (open-drain), software selectable Pull-up resistor 4.7 kω Vbus (nominally 5 V) Absolute voltage range Power-on state -0.5 V to 5.8 V with respect to GND Input (high impedance)

Digital Logic Levels Input low voltage Input high voltage Input leakage current Output low voltage, open collector or active drive I OL = 2 ma I OL = 8.5 ma Output high voltage, active drive 1 I OH = -2 ma I OH = -8.5 ma Output high voltage, open collector I OH = -0.4 ma, nominal I OH = -7.5 ma, with external pull-up resistor Counter -0.3 V minimum, 0.8 V maximum 2.0 V minimum, 5.8 V maximum 50.0 μa maximum 0.4 V maximum 0.8 V maximum 2.8 V minimum, 3.6 V maximum 2.0 V minimum, 3.5 V maximum 2.0 V minimum, 5.0 V maximum 2.0 V minimum Number of counters Resolution Counter measurements Maximum input frequency Minimum high pulse width Minimum low pulse width 1 (P2.7 can be configured as a counter) 32 bits Falling edge counting 5 MHz 100 ns 100 ns Bus Interface USB specification USB 2.0 Full Speed (12 Mb/s) 1 The total current sourced by all DO lines simultaneously should not exceed 65 ma. 2 ni.com USB-6501 Specifications

External Voltage +5 V output Voltage Current 4.00 V minimum, 5.25 V maximum 230 ma maximum Power Requirements USB Input voltage Active current Suspend current 4.50 VDC to 5.25 VDC, in configured state 80 ma typical, 500 ma maximum 500 μa maximum, all DIO lines disconnected Physical Characteristics Dimensions Weight Without connectors With connectors 6.35 cm 8.51 cm 2.31 cm (2.50 in. 3.35 in. 0.91 in.) 8.18 cm 8.51 cm 2.31 cm (3.22 in. 3.35 in. 0.91 in.) 84 g (3 oz) USB connector USB series B receptacle (1) I/O connectors Type 16-position (screw terminal) plug headers (2) Screw terminal wiring Torque for screw terminals 16 AWG to 28 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end 0.22 N m to 0.25 N m (2.0 lb in. to 2.2 lb in.) USB-6501 Specifications National Instruments 3

Figure 1. USB-6501 Dimensions 81.81 mm (3.221 in.) 23.19 mm (0.913 in.) NATIONAL INSTRUMENTS 76.09 mm (2.996 in.) 85.09 mm (3.350 in.) 63.50 mm (2.500 in.) 72.65 mm (2.860 in.) If you need to clean the module, wipe it with a dry towel. Safety Voltages Connect only voltages that are within these limits. Channel-to-COM (one channel) Channels-to-COM (one port, all channels) ±30 V max, Measurement Category I ±8.9 V max, Measurement Category I Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics Caution Do not use this module for connection to signals or for measurements within Measurement Categories II, III, or IV Note Measurement Categories CAT I and CAT O (Other) are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. 4 ni.com USB-6501 Specifications

Environmental Temperature (IEC 60068-2-1 and IEC 60068-2-2) Operating 0 C to 55 C Storage -40 C to 85 C Humidity (IEC 60068-2-56) Operating 5% to 90% RH, noncondensing Storage 5% to 90% RH, noncondensing Pollution Degree (IEC 60664) 2 Maximum altitude 2,000 m Indoor use only. Hazardous Locations This device is not certified for use in hazardous locations. Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions EN 55022 (CISPR 22): Class A emissions EN 55024 (CISPR 24): Immunity AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions USB-6501 Specifications National Instruments 5

FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations and certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 6 ni.com USB-6501 Specifications

电子信息产品污染控制管理办法 ( 中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物质指令 (RoHS) 关于 National Instruments 中国 RoHS 合规性信息, 请登录 ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) USB-6501 Specifications National Instruments 7

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2015 2017 National Instruments. All rights reserved. 375268C-01 September 22, 2017