Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Similar documents
Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Documentation. Mains filter AX2090-NF50. Version: Date:

Documentation. KL2784 und KL2794. Four channel digital output terminals with MOSFET transistors. Version: Date:

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

CU port USB 2.0 hub. Version: 1.1 Date:

Documentation. KL28xx. HD Bus Terminals, digital output 24 V DC. Version: Date:

C9900-P223 and C9900-P224

Documentation. KM3701, KM3702 and KM3712. Pressure Measuring Module. Version: Date:

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

CU Compact-Flash card adapter for USB. Version: 1.0 Date:

C9900-P208 and C9900-P209

Documentation for. TwinSAFE User. Tool to modify the User Administration of a TwinSAFE Logic. Version: Date:

Documentation KL2602, KL2622. Two-channel Relay Output Terminals. Version: Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Operating manual ELX9012, ELX9410, ELX9560. ELX System Terminals. Version: Date:

Description AX5805. List of permissible motors. Version: Date:

TC3 Interface for Matlab /Simulink

Documentation KL Channel Accurate Input Terminals for PT100 (RTD) Version: Date:

Installation- and Operating instructions for CU CFast card adapter with USB connector. Version: 1.1 Date:

Operating manual ELX channel digital input terminal for NAMUR sensors, Ex i. Version: Date:

Documentation KL2791. Single channel speed controller terminals for AC motors. Version: Date:

Documentation. FC2001 and FC2002. Lightbus PCI Interface Cards. Version: Date:

Documentation KL6781. M-Bus Master Terminals. Version: Date:

Documentation. EL28xx. Digital HD output Terminals. Version: Date:

Installation- and Operating instructions for CU CP-Link 4 transmitter box The Two Cable Display Link. Version: 1.

Operating manual ELX3152. Two channel, analog input terminal, 0/4 20 ma, single ended, 16 Bit, Ex i. Version: Date: 1.5.

Manual. PLC Lib: Tc2_SMI. TwinCAT 3. Version: Date:

Documentation. FC7501 and FC7502. SERCOS interface PCI Cards. Version: Date:

Documentation. KL85xx und KL9309. Manual operating modules with K-Bus interface. Version: Date:

Description AX5805. Default values for the permissible motors. Version: Date:

Manual. PLC Lib: Tc2_DMX. TwinCAT 3. Version: Date:

Manual. TC3 EtherCAT Simulation. TwinCAT 3. Version: Date: Order No.: TE1111

Manual. TC3 Virtual Serial COM. TwinCAT 3. Version: Date: Order No.: TF 6360

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

Manual. PLC Lib: Tc2_Coupler. TwinCAT 3. Version: Date:

KL5151/KS5151, KL5152/KS5152

Documentation KL3214. Four-channel HD input terminal for 3-wire connection of resistance sensors. Version: Date:

Documentation. KL31x2. 2 Channel Accurate Analog Terminals. Version: Date:

Manual. TC3 Power Monitoring. TwinCAT 3. Version: Date: Order No.: TF3650

KL2751/KS2751, KL2761/KS2761

Manual. TwinCAT MC Flying Saw. TwinCAT 3. Version: Date: Order No.: TF5055

PLC Lib: Tc3_MC2_AdvancedHoming

Manual. Software Protection. TwinCAT 3. Version: Date:

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

Application Note FC1100/FC1121 (EtherCAT Slave Card)

KL4414, KL4418, KL4424, KL4428

KL3444, KL3448, KL3454 und KL3458

Application Note FC1100/FC1121 (EtherCAT Slave Card)

Installation and Operating instructions for. Control Cabinet PC C6210. Version: 1.4 Date:

Documentation KL6224. IO-Link Terminal. Version: Date:

KL4404, KL4408, KL4434, KL4438

Operation Manual BK5000. Bus Coupler for CAN-CAL Version: 1.12

Documentation KL3681, KS3681. Multimeter Terminals. Version: Date:

Manual. PLC Lib: Tc2_Drive. TwinCAT 3. Version: Date:

Installation and Operating instructions for C Ultra compact Industrial PC. Version: 1.3 Date:

Documentation KL2542. Two channel output stage terminal for DC motors. Version: Date:

Manual CX Audio interface for CX20x0. Version: Date:

Documentation KL4132. Dual-channel analog output terminal, -10 V to +10 V, 16 Bit. Version: Date:

Installation and Operating instructions for C / Fanless Control Cabinet Industrial PC. Version: 1.0 Date:

Installation and Operating instructions for. Control Cabinet PC C6240 from Version: 2.0 Date:

EL9820/EL9821 Evaluation Kit. Version: 1.3 Date:

Installation and Operating instructions for Control Cabinet PC C6915

Installation and Operating instructions for Industrial PC series C61xx from Version: 3.0 Date:

Installation and Operating instructions for. Control Cabinet PC C6250 up to Version: 1.6 Date:

Documentation. EL20xx, EL2124. Digital Output Terminals. Version: Date:

KL2532/KS2532, KL2552/KS2552

Operating instructions for KL2904. TwinSAFE output terminal with 4 fail-safe outputs. Version: Date:

Documentation EL PROFINET DEVICE Supplement. Version: Date:

Documentation KL3214. Four-channel HD input terminal for 3-wire connection of resistance sensors. Version: Date:

KL , KS

Manual. PLC Lib: Tc2_Standard. TwinCAT 3. Version: Date:

Operation Manual for. EJ19xx and EJ29xx. TwinSAFE EJ Modules with digital fail-safe in and outputs. Version: Date: 1.2.

Documentation. EPI2xxx, ERI2xxx. IO-Link-Box Modules with digital outputs. Version: Date:

Operating Instructions

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Installation and Operating instructions for Industrial PC series C61xx up to Version: 2.6 Date:

Analog display for resistance current

Documentation. KL401x, KL402x. Single- and Dual-Channel Analog Output Terminals 0 to 20 ma and 4 to 20 ma. Version: Date: 4.

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Documentation. EL95xx. Power supply terminals. Version: Date:

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

KL304x, KL305x. Documentation. Single-, Dual- and Four-Channel Analog Input Terminals, Measuring range: ma and ma, Single ended

Manual. MATLAB /Simulink. TwinCAT 3. Version: Date:

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Documentation. EPI2xxx. IO-Link-Box Modules with digital inputs. Version: Date:

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Installation- and Operating instructions for. Build-in Industrial PCs C3620, C3640 from Version: 3.0 Date:

Documentation. KL400x. Single-, Dual and Four-Channel Analog Output Terminals, (0V...10V) Version: Date:

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Transcription:

Documentation KM2002, KM2004, KM2008 Terminal modules with digital outputs, 24 V, 0.5 A Version: Date: 3.2.0 2017-01-23

Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety instructions... 5 1.3 Documentation Issue Status... 6 2 Product overview... 7 2.1 Terminal Modules - System Overview... 7 2.2 KM2002... 10 2.2.1 Introduction... 10 2.2.2 Technical data... 11 2.3 KM2004... 12 2.3.1 Introduction... 12 2.3.2 Technical data... 13 2.4 KM2008... 14 2.4.1 Introduction... 14 2.4.2 Technical data... 15 2.5 KM plug-in connectors... 15 2.5.1 Ordering information for KM plug-in connector... 15 2.5.2 Technical Data... 16 3 Mounting and Wiring... 17 3.1 Recommended mounting rails... 17 3.2 Dimensions... 17 3.3 Mounting and demounting - terminals with traction lever unlocking... 19 3.4 Mounting and demounting - terminals with front unlocking... 21 3.5 Wiring... 23 3.6 Connection... 25 4 Access from the user programm... 26 4.1 Process Image... 26 5 Appendix... 27 5.1 Support and Service... 27 KM2002, KM2004, KM2008 Version: 3.2.0 3

Foreword 1 Foreword 1.1 Notes on the documentation Intended audience This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the documentation and the following notes and explanations are followed when installing and commissioning these components. It is the duty of the technical personnel to use the documentation published at the respective time of each installation and commissioning. The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards. Disclaimer The documentation has been prepared with care. The products described are, however, constantly under development. We reserve the right to revise and change the documentation at any time and without prior announcement. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation. Trademarks Beckhoff, TwinCAT, EtherCAT, Safety over EtherCAT, TwinSAFE, XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. Patent Pending The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries. The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany Copyright Beckhoff Automation GmbH & Co. KG, Germany. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. 4 Version: 3.2.0 KM2002, KM2004, KM2008

Foreword 1.2 Safety instructions Safety regulations Please note the following safety instructions and explanations! Product-specific safety instructions can be found on following pages or in the areas mounting, wiring, commissioning etc. Exclusion of liability All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. Personnel qualification This description is only intended for trained specialists in control, automation and drive engineering who are familiar with the applicable national standards. Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note. The safety instructions must be read carefully and followed without fail! DANGER WARNING CAUTION Attention Serious risk of injury! Failure to follow the safety instructions associated with this symbol directly endangers the life and health of persons. Risk of injury! Failure to follow the safety instructions associated with this symbol endangers the life and health of persons. Personal injuries! Failure to follow the safety instructions associated with this symbol can lead to injuries to persons. Damage to the environment or devices Failure to follow the instructions associated with this symbol can lead to damage to the environment or equipment. Tip or pointer This symbol indicates information that contributes to better understanding. Note KM2002, KM2004, KM2008 Version: 3.2.0 5

Foreword 1.3 Documentation Issue Status Version Comment 3.2.0 Technical data for KM plug-in connectors updated 3.1.0 Technical data for KM plug-in connectors extended Update structure 3.0.0 Migration Update structure Technical data updated 2.0.0 Notes about wiring and mounting updated Technical data updated 1.0.2 Technical data updated Pinning of terminal block X1 corrected 1.0.1 Notes about wiring and mounting updated Notes about wiring technique corrected Technical data updated 1.0.0 KM2004 and KM2008 added Mounting and demounting added Dimension drawings added 0.1 first preliminary documentation for KM2002 Firm and hardware versions Documentation version Hardware version KM2002 KM2004 KM2008 3.2.0 06 05 04 3.1.0 06 05 04 3.0.0 06 05 04 2.0.0 05 03 02 1.0.2 02 02 00 1.0.1 01 00 00 1.0.0 01 00 00 0.1 00 - - The hardware version can be found in the serial number printed at the top of the terminal module. Syntax of the serial number Structure of the serial number: WW YY FF HH WW - week of production (CW, calendar week) YY - year of production FF - firmware version (n/a for digital modules) HH - hardware version Example with Ser. No.: 35 05 00 01 35 - week of production 35 05 - year of production 2005 00 - firmware version 00 01 - hardware version 01 6 Version: 3.2.0 KM2002, KM2004, KM2008

Product overview 2 Product overview 2.1 Terminal Modules - System Overview Fig. 1: Bus Terminal Block Better sensor and actuator functionality makes machines and systems more and more powerful. The Bus Terminal reliably meets increased requirements for I/O signals through its modularity and compact design. The existing Beckhoff Bus Terminal system is complemented by the new version of the EMxxxx / KMxxxx Terminal Module with increased packing density. In many areas of application, cost benefits can be realized through lower overall installed size and application-specific signal mix. The new Terminal Modules are fully system-compatible. Like the Bus Terminals, they are bus-neutral and can therefore be operated with any Beckhoff Bus Coupler and Bus Terminal Controller. Like the standard Bus Terminals, the EM / KM modules are integrated in the I/O system and connected with the internal terminal bus (E-bus / K-bus). Bus Terminals and terminal modules can be combined without restriction. Plug connector Like for the Bus Terminals, no tools are required for the wiring. Spring-loaded technology is used, however the connection layer is pluggable (fixed wiring). Fig. 2: Pluggable connection (fixed wiring) KM2002, KM2004, KM2008 Version: 3.2.0 7

Product overview Connection Plug connectors are available for single and triple conductor connection methods. Fig. 3: Terminal module with plug connector for single conductor connection method (ZS2001-0002) Fig. 4: Terminal module with plug connector for triple-conductor connection method (ZS2001-0004) Packing density The Terminal Modules combine 16, 32 or 64 digital inputs or outputs on a very small area. This compact and slimline design enables very high packing densities, leading to smaller control cabinets and terminal boxes. 8 Version: 3.2.0 KM2002, KM2004, KM2008

Product overview Fig. 5: Terminal module with 16 channels Fig. 6: Terminal module with 32 channels Fig. 7: Terminal module with 64 channels KM2002, KM2004, KM2008 Version: 3.2.0 9

Product overview 2.2 KM2002 2.2.1 Introduction Fig. 8: Digital Terminal Module with 16 output channels Digital Terminal Module with 16 output channels (24 V DC ) The terminal module KM2002 combines 16 digital outputs with 8 channels per plug connector in a compact design with high packing density. The binary control signals are transferred (electrically isolated) to the actuators at the process level. Like the standard Bus Terminals, the terminal modules are integrated in the Beckhoff I/O system. Plug connectors with spring connections enable plug-in wiring and are available with 1 or 3 pins. LEDs integrated in the connector indicate the signal state for each channel directly at the wire. The outputs are protected against overload and short circuit. Table 1: Ordering information for terminal modules with 16 digital inputs Ordering name KM2002-0000 KM2002-0001 KM2002-0002 KM2002-0004 Scope of supply digital output module, 16 channels (0.5 A), without connectors digital output module, 16 channels (0.5 A), with 2 connectors ZS2001-0001 digital output module, 16 channels (0.5 A), with 2 connectors ZS2001-0002 digital output module, 16 channels (0.5 A), with 2 connectors ZS2001-0004 See also chapter ordering information for KM plug-in connectors [} 15]. 10 Version: 3.2.0 KM2002, KM2004, KM2008

Product overview 2.2.2 Technical data Technical data KM2002 Number of outputs 16 (2 x 8) Nominal voltage 24 V DC (-15%/+20%) Load type Output current per channel Short circuit current Breaking energy (inductive) Power supply for the electronics Current consumption from K-bus Current consumption from the load voltage (24 V) With of an Bus Terminal block Electrical isolation Bit width in the output process image Dimensions with connector (W x H x D) Weight (without connector) Permissible ambient temperature range during operation Permissible ambient temperature range during storage Permissible relative humidity ohmic, inductive, lamp load max. 0.5 A 0.6... 1.0 A < 150 mj/channel via the K-Bus typically 5 ma typically 15 ma max. [} 18] 64 standard bus terminals or 80 cm (for this a KM2002 is equivalent to 2 standard bus terminals) 500 V (K-Bus / signal voltage) 16 bit approx. 26.5mm x 100 mm x 71mm (aligned width: 24mm), see dimensional drawing [} 17] approx. 70 g 0 C...+55 C -25 C...+85 C 95%, no condensation Mounting [} 21] on 35 mm mounting rail according to EN 60715 Vibration / shock resistance conforms to EN 60068-2-6 / EN 60068-2-27 EMC resistance burst / ESD conforms to EN 61000-6-2 / EN 61000-6-4 Protection class Installation position Approval IP20 variable CE KM2002, KM2004, KM2008 Version: 3.2.0 11

Product overview 2.3 KM2004 2.3.1 Introduction Fig. 9: Digital Terminal Modules with 32 output channels Digital Terminal Modules with 32 output channels (24 V DC ) The terminal module KM2004 combines 32 digital outputs with 8 channels per plug connector in a compact design with high packing density. The binary control signals are transferred (electrically isolated) to the actuators at the process level. Like the standard Bus Terminals, the terminal modules are integrated in the Beckhoff I/O system. Plug connectors with spring connections enable plug-in wiring and are available with 1 or 3 pins. LEDs integrated in the connector indicate the signal state for each channel directly at the wire. The outputs are protected against overload and short circuit. Table 2: Ordering information for terminal modules with 32 digital inputs Ordering name KM2004-0000 KM2004-0001 KM2004-0002 KM2004-0004 Scope of supply digital output module, 32 channels (0.5 A), without connectors digital output module, 32 channels (0.5 A), with 4 connectors ZS2001-0001 digital output module, 32 channels (0.5 A), with 4 connectors ZS2001-0002 digital output module, 32 channels (0.5 A), with 4 connectors ZS2001-0004 See also chapter ordering information for KM plug-in connectors [} 15]. 12 Version: 3.2.0 KM2002, KM2004, KM2008

Product overview 2.3.2 Technical data Technical data KM2004 Number of outputs 32 (4 x 8) Nominal voltage 24 V DC (-15%/+20%) Load type Output current per channel Short circuit current Breaking energy (inductive) Power supply for the electronics Current consumption from K-bus Current consumption from the load voltage (24 V) With of an Bus Terminal block Electrical isolation Bit width in the output process image Dimensions with connector (W x H x D) Weight (without connector) Permissible ambient temperature range during operation Permissible ambient temperature range during storage Permissible relative humidity ohmic, inductive, lamp load max. 0.5 A 0.6... 1.0 A < 150 mj/channel via the K-Bus typically 5 ma typically 15 ma max. [} 18] 64 standard bus terminals or 80 cm (for this a KM2004 is equivalent to 4 standard bus terminals) 500 V (K-Bus / signal voltage) 32 bit approx. 75mm x 100 mm x 55mm (aligned width: 73mm), see dimensional drawing [} 18] approx. 150 g 0 C...+55 C -25 C...+85 C 95%, no condensation Mounting [} 19] on 35 mm mounting rail according to EN 60715 Vibration / shock resistance conforms to EN 60068-2-6 / EN 60068-2-27 EMC resistance burst / ESD conforms to EN 61000-6-2 / EN 61000-6-4 Protection class Installation position Approval IP20 variable CE KM2002, KM2004, KM2008 Version: 3.2.0 13

Product overview 2.4 KM2008 2.4.1 Introduction Fig. 10: Digital Terminal Modules with 64 output channels Digital Terminal Modules with 64 output channels (24 V DC ) The terminal module KM2008 combines 64 digital outputs with 8 channels per plug connector in a compact design with high packing density. The binary control signals are transferred (electrically isolated) to the actuators at the process level. Like the standard Bus Terminals, the terminal modules are integrated in the I/ O system. Plug connectors with spring connections enable plug-in wiring and are available with 1 or 3 pins. LEDs integrated in the connector indicate the signal state for each channel directly at the wire. The outputs are protected against overload and short circuit. Table 3: Ordering information for terminal modules with 64 digital inputs Ordering name KM2008-0000 KM2008-0001 KM2008-0002 KM2008-0004 Scope of supply digital output module, 64 channels (0.5 A), without connectors digital output module, 64 channels (0.5 A), with 8 connectors ZS2001-0001 digital output module, 64 channels (0.5 A), with 8 connectors ZS2001-0002 digital output module, 64 channels (0.5 A), with 8 connectors ZS2001-0004 See also chapter ordering information for KM plug-in connectors [} 15]. 14 Version: 3.2.0 KM2002, KM2004, KM2008

Product overview 2.4.2 Technical data Technical data KM2008 Number of outputs 64 (8 x 8) Nominal voltage 24 V DC (-15%/+20%) Load type Output current per channel Short circuit current Breaking energy (inductive) Power supply for the electronics Current consumption from K-bus Current consumption from the load voltage (24 V) With of an Bus Terminal block Electrical isolation Bit width in the output process image Dimensions with connector (W x H x D) Weight (without connector) Permissible ambient temperature range during operation Permissible ambient temperature range during storage Permissible relative humidity ohmic, inductive, lamp load max. 0.5 A 0.6... 1.0 A < 150 mj/channel via the K-Bus typically 5 ma typically 15 ma max. [} 18] 64 standard bus terminals or 80 cm (for this a KM2008 is equivalent to 8 standard bus terminals) 500 V (K-Bus / signal voltage) 64 bit approx. 123mm x 100 mm x 55mm (aligned width: 121mm), see dimensional drawing [} 18] approx. 225 g 0 C...+55 C -25 C...+85 C 95%, no condensation Mounting [} 19] on 35 mm mounting rail according to EN 60715 Vibration / shock resistance conforms to EN 60068-2-6 / EN 60068-2-27 EMC resistance burst / ESD conforms to EN 61000-6-2 / EN 61000-6-4 Protection class Installation position Approval IP20 variable CE 2.5 KM plug-in connectors 2.5.1 Ordering information for KM plug-in connector Fig. 11: KM plug-in connector for single-wire connection (ZS2001-0001, ZS2001-0002) KM2002, KM2004, KM2008 Version: 3.2.0 15

Product overview Fig. 12: KM plug-in connector for tree-wire connection (ZS2001-0004) Ordering name Signal LEDs Wiring technique single-wire two-wire three-wire ZS2001-0001 no yes no no ZS2001-0002 yes yes no no ZS2001-0004 yes yes yes yes 2.5.2 Technical Data Technical Data ZS2001-0001 ZS2001-0002 ZS2001-0004 Number of terminal points 10 10 30 Signal LEDs no yes yes Nominal voltage Nominal current Cycle of connector operation 25 Wire size width Maximum outer diameter of the conductor Wire stripping length Dimensions (w x h x d) 24 V DC 2 A Solid: 0.2 mm 2... 1.0 mm 2 (H05V-U, H07V-U) stranded: 0.2 mm 2... 1.5 mm (H05V-K, H07V-K) with ferrule: 0.2 mm 2... 1.0 mm 2 (ferrule to DIN 46 228 pt 1) 0.2 mm 2... 0.75 mm 2 (ferrule with plastic collar to DIN 46 228 pt 4) 2.9 mm 8 mm, 10 mm for use with ferrule app. 42mm x 10.3mm x 26.9mm app. 42mm x 12.7mm x 26.9mm Weight app. 11 g app. 13 g app. 23 g Permissible ambient temperature range during operation Permissible ambient temperature range during storage Permissible relative humidity 0 C... +55 C -25 C... +55 C 80%, no condensation Vibration / shock resistance conforms to EN 60068-2-6 / EN 60068-2-27 EMC resistance burst / ESD conforms to EN 61000-6-2 / EN 61000-6-4 Protection class Installation position IP20 variable app. 42mm x 20.8mm x 26.9mm 16 Version: 3.2.0 KM2002, KM2004, KM2008

Mounting and Wiring 3 Mounting and Wiring 3.1 Recommended mounting rails Terminal Modules und EtherCAT Modules of KMxxxx and EMxxxx series, same as the terminals of the EL66xx and EL67xx series can be snapped onto the following recommended mounting rails: DIN Rail TH 35-7.5 with 1 mm material thickness (according to EN 60715) DIN Rail TH 35-15 with 1,5 mm material thickness Note Pay attention to the material thickness of the DIN Rail Terminal Modules und EtherCAT Modules of KMxxxx and EMxxxx series, same as the terminals of the EL66xx and EL67xx series does not fit to the DIN Rail TH 35-15 with 2,2 to 2,5 mm material thickness (according to EN 60715)! 3.2 Dimensions KM10x2, KM20x2 Fig. 13: Dimensions KM10x2, KM20x2 KM2002, KM2004, KM2008 Version: 3.2.0 17

Mounting and Wiring KM10x4, KM20x4 Fig. 14: Dimensions KM10x4, KM20x4 KM10x8, KM20x8 Fig. 15: Dimensions KM10x8, KM20x8 Width of a Bus Terminal block Attention Pay attention to the maximum with and the current consumption A maximum of 64 Bus Terminals or Bus Terminal Modules may be aligned to a Bus Coupler! An overall with of 80 cm must not be exceeded! Also take care that the current consumption of the Bus Terminals / Bus Terminal Modules does not overstrain the K-Bus power supply of the Bus Coupler! 18 Version: 3.2.0 KM2002, KM2004, KM2008

Mounting and Wiring 3.3 Mounting and demounting - terminals with traction lever unlocking The terminal modules are fastened to the assembly surface with the aid of a 35 mm mounting rail (e.g. mounting rail TH 35-15). Note WARNING Fixing of mounting rails The locking mechanism of the terminals and couplers extends to the profile of the mounting rail. At the installation, the locking mechanism of the components must not come into conflict with the fixing bolts of the mounting rail. To mount the recommended mounting rails under the terminals and couplers, you should use flat mounting connections (e.g. countersunk screws or blind rivets). Risk of electric shock and damage of device! Bring the bus terminal system into a safe, powered down state before starting installation, disassembly or wiring of the Bus Terminals! Mounting Fit the mounting rail to the planned assembly location. and press (1) the terminal module against the mounting rail until it latches in place on the mounting rail (2). Attach the cables. Demounting Remove all the cables. Thanks to the KM/EM connector, it is not necessary to remove all the cables separately for this, but for each KM/EM connector simply undo 2 screws so that you can pull them off (fixed wiring)! Lever the unlatching hook on the left-hand side of the terminal module upwards with a screwdriver (3). As you do this an internal mechanism pulls the two latching lugs (3a) from the top hat rail back into the terminal module, the unlatching hook moves forwards (3b) and engages KM2002, KM2004, KM2008 Version: 3.2.0 19

Mounting and Wiring In the case 32 and 64 channel terminal modules (KMxxx4 and KMxxx8 or EMxxx4 and EMxxx8) you now lever the second unlatching hook on the right-hand side of the terminal module upwards in the same way. Pull (4) the terminal module away from the mounting surface. 20 Version: 3.2.0 KM2002, KM2004, KM2008

Mounting and Wiring 3.4 Mounting and demounting - terminals with front unlocking The terminal modules are fastened to the assembly surface with the aid of a 35 mm mounting rail (e.g. mounting rail TH 35-15). Note WARNING Fixing of mounting rails The locking mechanism of the terminals and couplers extends to the profile of the mounting rail. At the installation, the locking mechanism of the components must not come into conflict with the fixing bolts of the mounting rail. To mount the recommended mounting rails under the terminals and couplers, you should use flat mounting connections (e.g. countersunk screws or blind rivets). Risk of electric shock and damage of device! Bring the bus terminal system into a safe, powered down state before starting installation, disassembly or wiring of the Bus Terminals! Mounting Fit the mounting rail to the planned assembly location. and press (1) the terminal module against the mounting rail until it latches in place on the mounting rail (2). Attach the cables. Demounting Remove all the cables. Lever the unlatching hook back with thumb and forefinger (3). An internal mechanism pulls the two latching lugs (3a) from the top hat rail back into the terminal module. KM2002, KM2004, KM2008 Version: 3.2.0 21

Mounting and Wiring Pull (4) the terminal module away from the mounting surface. Avoid canting of the module; you should stabilize the module with the other hand, if required. 22 Version: 3.2.0 KM2002, KM2004, KM2008

Mounting and Wiring 3.5 Wiring WARNING Risk of electric shock and damage of device! Bring the bus terminal system into a safe, powered down state before starting installation, disassembly or wiring of the Bus Terminals! Supply voltage connection The illustration shows the connection of the supply voltage for the module electronics and the actuators to two KM connectors. Fig. 16: Supply voltage connection Note Power the internal electronics the positive supply voltage to terminal location +24 V the negative supply voltage to terminal location 0 V KM2002, KM2004, KM2008 Version: 3.2.0 23

Mounting and Wiring Connecting the actuators Pin assignment for channels 1 to 16 Channel Terminal point at KM connector 1 0 X0 2 1 X0 3 2 X0 4 3 X0 5 4 X0 6 5 X0 7 6 X0 8 7 X0 9 0 X1 10 1 X1 11 2 X1 12 3 X1 13 4 X1 14 5 X1 15 6 X1 16 7 X1 For terminal modules with more than 16 channels, you will find the assignment of the channels to the additional KM connectors in the description of the Process image [} 26]. 24 Version: 3.2.0 KM2002, KM2004, KM2008

Mounting and Wiring 3.6 Connection The actuators can be connected in single- (see example, terminal point 0), two- (see example, terminal point 3) or three wire technique (see example, terminal point 6). Fig. 17: Connection KM2002, KM2004, KM2008 Version: 3.2.0 25

Access from the user programm 4 Access from the user programm 4.1 Process Image KM2002 The process image of the terminal module KM2002 consists of 2 byte output data. Byte offset Format Output data KM plug-in connector 0 byte DataOUT (channel 1 to 8) X0 1 byte DataOUT (channel 9 to 16) X1 KM2004 The process image of the terminal module KM2004 consists of 4 byte output data. Byte offset Format Output data KM plug-in connector 0 byte DataOUT (channel 1 to 8) X0 1 byte DataOUT (channel 9 to 16) X1 2 byte DataOUT (channel 17 to 24) X2 3 byte DataOUT (channel 25 to 32) X3 KM2008 The process image of the terminal module KM2008 consists of 8 byte output data. Byte offset Format Output data KM plug-in connector 0 byte DataOUT (channel 1 to 8) X0 1 byte DataOUT (channel 9 to 16) X1 2 byte DataOUT (channel 17 to 24) X2 3 byte DataOUT (channel 25 to 32) X3 4 byte DataOUT (channel 33 to 40) X4 5 byte DataOUT (channel 41 to 48) X5 6 byte DataOUT (channel 49 to 56) X6 7 byte DataOUT (channel 57 to 64) X7 26 Version: 3.2.0 KM2002, KM2004, KM2008

Appendix 5 Appendix 5.1 Support and Service Beckhoff and their partners around the world offer comprehensive support and service, making available fast and competent assistance with all questions related to Beckhoff products and system solutions. Beckhoff's branch offices and representatives Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: http://www.beckhoff.com You will also find further documentation for Beckhoff components there. Beckhoff Headquarters Beckhoff Automation GmbH & Co. KG Huelshorstweg 20 33415 Verl Germany Phone: +49(0)5246/963-0 Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with other, wide-ranging services: support design, programming and commissioning of complex automation systems and extensive training program for Beckhoff system components Hotline: +49(0)5246/963-157 Fax: +49(0)5246/963-9157 e-mail: support@beckhoff.com Beckhoff Service The Beckhoff Service Center supports you in all matters of after-sales service: on-site service repair service spare parts service hotline service Hotline: +49(0)5246/963-460 Fax: +49(0)5246/963-479 e-mail: service@beckhoff.com KM2002, KM2004, KM2008 Version: 3.2.0 27

Table of figures Table of figures Fig. 1 Bus Terminal Block... 7 Fig. 2 Pluggable connection (fixed wiring)... 7 Fig. 3 Terminal module with plug connector for single conductor connection method (ZS2001-0002). 8 Fig. 4 Terminal module with plug connector for triple-conductor connection method (ZS2001-0004).. 8 Fig. 5 Terminal module with 16 channels... 9 Fig. 6 Terminal module with 32 channels... 9 Fig. 7 Terminal module with 64 channels... 9 Fig. 8 Digital Terminal Module with 16 output channels... 10 Fig. 9 Digital Terminal Modules with 32 output channels... 12 Fig. 10 Digital Terminal Modules with 64 output channels... 14 Fig. 11 KM plug-in connector for single-wire connection (ZS2001-0001, ZS2001-0002)... 15 Fig. 12 KM plug-in connector for tree-wire connection (ZS2001-0004)... 16 Fig. 13 Dimensions KM10x2, KM20x2... 17 Fig. 14 Dimensions KM10x4, KM20x4... 18 Fig. 15 Dimensions KM10x8, KM20x8... 18 Fig. 16 Supply voltage connection... 23 Fig. 17 Connection... 25 28 Version: 3.2.0 KM2002, KM2004, KM2008