VAN WALT Monitoring your needs

Similar documents
Aqua4Plus 2.0. Control Software for LevelSCOUT, BaroSCOUT, PT2X, CT2X PROUDLY MADE IN THE USA

Remote Water Level Monitoring Technical Note Product: HOBO RX3000 Station

Diver-Office Premium DEMONSTRATION EXCERCISE

INSTRUCTION MANUAL. AquiStar PT2X-BV. Barometric/Vacuum Sensor and Datalogger

ZLog Z6R Altitude Data Recording and Monitoring System

HOW TO USE THE EXPORT FEATURE IN LCL

Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Part #: MAN-BHW-GS Doc #: B. 28 HOBOware Getting Started Guide

Quick Start Guide Levelogger Series

AquaTroll 600 Configuration and MultiLogger Integration

BaroSCOUT. Barometric/Temperature Smart Sensor and Datalogger ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

Flo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT

BaroSCOUT. Barometric/Temperature Smart Sensor and Datalogger ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

User Guide. Levelogger Series Software Version 4

INW LevelSCOUT Level/Temperature Smart Sensor and Datalogger

Using the Hotwire Anemometer

The Art of Measuring. User Manual English. Paraly SW 112. Latest Product Information:

Remote Water Level Monitoring Technical Note Product: HOBO RX3000 Station

LevelSCOUT. Level/Temperature Smart Sensor and Datalogger ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

RST INSTRUMENTS LTD.

Microsoft Access 2010

Tutorial 3 - Performing a Change-Point Analysis in Excel

TRIDENT MOISTURE METER MEASUREMENT SYSTEM

Kulite DAQ. Data Acquisition Software User s Manual. Version 3.2.0

Microsoft Access 2013

Microsoft Access 2013

Display & Log Unit. Mikael Larsmark. November 22, 2006

Mission Guide: GUI Windows

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

User Guide. Levelogger Series Software Version 4

Overview Recap 1. Modifying an App 2. Add an additional Database a. b.

Operator Quick Guide ORBISPHERE 3650

Basic Tasks in ArcGIS 10.3.x

OPERATIONS & MAINTENANCE MANUAL

About the GS4200-USB

LevelSCOUT. Level/Temperature Smart Sensor and Datalogger ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

Datalogging Conductivity/ TDS Meter. Instruction Manual

**These steps start after you have a complete model and decide to start rendering views.

ADS PrimeWorks User Manual

Manual Lindab Analysis. PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function. Art. n.

TRIO-TECH SOFTWARE CONTENTS

Quick Start Guide Levelogger Series

More Skills 11 Export Queries to Other File Formats

Aqua4Plus. Control Software for Seametrics Smart Sensors ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE.

NPA/ChipCap Sensor Evaluation Kit: Pressure, Humidity & Temperature

Client Care Desktop V4

Software for HOBO loggers

DPL4000 Portable Low Range Dew Point Analyzer

Geomagic Leica Tracker Plug-In 1.0 User s Manual

Mini Mini GlobiLab Software Quick Start Guide

Quick Guide. NomaSense or O 2. USB cable. Temperature probe PT100. Short optical fiber

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

HI 9828 Multiparameter Water Quality Meter...

Pearson CTC User Roles Update and Security Audit Process

Greyline Logger. Greyline Logger

Autodesk Moldflow Insight AMI Analysis Overview Tutorial

HI 9828 Multiparameter Water Quality Meter...

INSTRUCTION MANUAL. AquiStar Aqua4Plus. Control Software for INW Smart Sensors

Client Care Desktop v4.3. Document Manager V4.3

Introduction. Mail Merge. Word 2010 Using Mail Merge. Video: Using Mail Merge in Word To Use Mail Merge: Page 1

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

1 Exporting Files from Maestro Easy Dental Scan Great Lakes Orthodontics

ESI Inc. GS4200-USB Troubleshooting. Phone: Fax:

DataPro Designer Quick Start Guide

DOC Flo-Ware 4 Software. User Manual. July 2010, Edition 1. Hach Company, All rights reserved. Printed in the U.S.A.

Manual Whisker Annotator

v CMS-Wave Analysis SMS 12.2 Tutorial Prerequisites Requirements Time Objectives

Instruction Manual. for the. LeveLine. Range of Level and Baro Logging Probes and associated LeveLine Meter, Utilities & Accessories

HOBOlink User s Guide

Managing CSC within SoftPro 360

Technical Note: Interfacing a C-sense pco 2 Sensor to a Campbell Scientific CR1000 Datalogger

BlueDAQ QUICK START GUIDE Software for use with models BSC4D, BSC8D, BX8 and 9330

Getting Started. onset computer corporation. Software for HOBO Data Loggers & Devices

Exporting distribution lists from Thunderbird to Outlook

Gauss/Tesla Meters. Application Note January 2013 Data Logging using HyperTerminal and SCPI Commands on the 8000 Series

Thermo-Anemometer Data Logger Model 1227

Level TROLL 100 and Level TROLL 200 Operator s Guide

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Unit 12. Electronic Spreadsheets - Microsoft Excel. Desired Outcomes

Contents. Contents... 1 Introduction... 4 An Overview of HOBOware... 4

ASM-IV ARGUS SURFACE METER

Brief Risk Overview (BRO) User Guide

Contents. Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Contents Introduction... 3 An Overview of HOBOware...

Microsoft Access 2010

ICM Logger Database Configuration Synchronization

Levelogger Series. (Levelogger Gold, Barologger Gold, Levelogger Junior, LTC Levelogger Junior and Rainlogger) User Guide - Software Version 3.4.

- MANUAL FOR PC CONNECTION -

onset computer corporation Lite HOBOware Software for HOBO Data Loggers & Devices User s Guide Doc #: C

Vibration Meter SD Card real-time datalogger

Enterprise Navigation

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

User Guide. Levelogger Series - Software Version 4.3.2

About this Guide How the Document is Organized... 5 Definition of Terms Chapter 1 PMManager and Devices... 6

KWJ-WSN & USB Gateway. Quick Start Guide

Direct Image Viewer User Tutorial

PELICAN Data Warehouse

Global Water globalw.com. For Use With WQ-FDO Sensor and GL Data Logger. Global Water. Instrumentation, Inc.

Benchtop Multi-parameter Water Quality Meter

Introduction to Computer Science

8.0.6 New Features Guide Auto Window/Level Adjustments

Transcription:

The LevelSCOUT is an absolute pressure logger: that means that in addition to the pressure due to the water column above the sensor, it is also measuring the atmospheric pressure. To obtain just the pressure due to the water column, you must subtract the atmospheric pressure. This could be achieved automatically with the software (Aqua4Plus), if in addition to the LevelSCOUT you have been using a BaroSCOUT to record the barometric (atmospheric) pressure. Top of Well BaroSCOUT Barometric Sensor Must stay above water level! LevelSCOUT Absolute Pressure / Level Sensor Air Pressure Air+Water Pressure Depth-to-Water (*) Column of Water (**) Figure 1 MA198V1_19/12/2016_JO

From the version 1.9.10 of the Aqua4Plus software, in addition to the barometric compensation, there is also the choice to enter a depth to water offset, and in this way compensated values could be presented related to a datum, for example Top of Well. A. SETUP 1. Start with BaroSCOUT a. Connect the BaroSCOUT to the USB communication cable, click on the Scan Button to find the BaroSCOUT. b. Setup the logging schedule on the BaroSCOUT. Name your file by entering a name on the File Name Box. Remember to check mark the Set Sensor Clock on the Logging Schedule Screen. c. Click the Start Button. d. In order that the time sequences are fully populated we would always recommend that you set and start the BaroSCOUT first and read it last. 2. Now follow with the LevelSCOUT: connect it to the USB cable, and repeat steps a), b) and c) from above. 3. Deploying of the LevelSCOUT and depth-to-water measurement: the dip measurement can be made at any point in the time sequence, but good practice prefers that you do this at deployment. We would recommend that you use the top of the well as your initial datum: this is for practical reasons, as there is a clear edge against which to measure. This initial dip to water measurement should be done AFTER deployment of the logger, and this is especially important in narrow diameter wells because of the logger s water displacement. Take time over the measurement and make sure that is as accurate as possible, ensuring that your dip meter is straight and without any kinks. Once measurement has been made, record this value and the exact time in your field notes.

B. DATA RETRIEVAL AND COMPENSATION 1. Once you have completed your recording time, you should retrieve the data from the BaroSCOUT and LevelSCOUT: connect to the USB cable, scan for the sensor, and retrieve data 2. Open the Barometric Compensation Utility (on the Utilities Menu of the Aqua4Plus). The following dialog will open: 3. First, select one or more absolute data files to be converted. Click the top Browse button and navigate to the file(s) you want to convert. To select one file, simply double-click on the file name. To select two or more files, click on the first file, then hold down the Ctrl key and click on each of the other files you want to convert. Then click OK. 4. Next, select the barometric file you wish to use for the compensation. Click on the lower Browse button and navigate to the file you want to use. Double-click on the file name. 5. If you do NOT want to provide a manual depth to water reading, do not checkmark the box I want to provide a depth-to-water reference, and proceed to step 7. 6. If you want to enter a manual depth-to-water reading, checkmark the box I want to provide a depth-to-water reference. One of the following boxes will display, depending on whether you are converting one or many data files. For each sensor, enter the date/time and

Depth-to Water Reference for a Single Sensor Depth-to Water Reference for a Multiple Sensor measurement you took previously. If you are converting several files, you have the option to enter depth-to-water offsets for each sensor or to checkmark the box in the Skip column, if not needed for a particular sensor. Click OK to continue. 7. To begin the conversion, click OK. 8. Aqua4Plus will take each record in the absolute data file, apply the depth-to-water offset (if applicable) and the barometric reading closest in time to that reading, and then create a new, converted file. The original data files will have an extension of.a4d. The compensated files will have the same file names but with an extension of.a4b. A compensated file will be created for each original data file.

C. VIEWING AND EXPORTING THE COMPENSATED DATA 1. To view your newly compensated files, click on the Open button. A File Open box will be displayed 2. On the file type box, click the down arrow and select Aqua4Plus Compensated Files. The box will then list your compensated files. (If you select Aqua4Plus Data Files instead, original data files will be listed.) Double-click on the file you want to open. Your data will display in the File Display window. The values on the Pressure column represent the barometrically compensated pressure.

3. To export your data to a coma separated value file or an Excel file, click the Export button. Exports will show general file information and calibration values for both the original data file and the barometric file that was used to do the conversion. The data will be displayed in the following columns. Rec#: Date/Time: Pressure: Temperature: Sensor Pressure: Barometric Date/Time: Record number in the original data file Date and time of sample from original data file Barometrically compensated pressure Temperature Pressure from the original data file (absolute pressure) The time of the reading in the barometric file that was used for each line in the data file. 4. In case you have introduced a Depth-to-Water manual measurement (as shown below on the spreadsheet 1), the values on the compensated pressure column, will already have the calculation made to show the values referenced to the Top of the Well (or whichever reference you have taken to make the initial depth-to-water manual measurement): see figure 1, Depth-to-Water (*). Normally the first measurements shown on the table are taken out of the water, and they will represent the cable length used to deploy the LevelSCOUT Manual depth-to-water date/ time and measurement 1st measurement out of water: represents cable length Compensated pressure data, referenced to the top of the well (depth to Original absolute pressure data water values) Spreadsheet 1, with Depth-to-Water values Date/time of record that was used from the barometric file

5. In case you have not introduced a Depth-to-Water measurement (as shown below on the spreadsheet 2), the values on the compensated pressure column will show no other correction or calculation apart from the barometrically compensation, so they will be showing the value of the water column above the LevelSCOUT: see figure 1, Column of Water (**) 1st measurement out of water: 0 cm water column Compensated pressure data, with actual water column values Original absolute pressure data Date/time of record that was used from the barometric file Spreadsheet 2, with water column values