Intelligent Double Conversion On-Line UPS Superior Power Protection PowerOn's sophisticated double conversion design continually regenerates utility power to provide the ultimate in power protection: Stabilizes voltages and frequencies and filters out electric noise. Isolates valuable equipment against harmful power disturbances. Intelligent, User-Friendly, and Reliable Large Format LCD Display PowerOn's easy-to-read 32 character dot-matrix LCD screen displays lots of useful information, including UPS operating status (normal or abnormal), sixteen different specific abnormal conditions, and eleven realtime power measures including input voltage,output voltage, current, battery voltage, and battery discharge level. Self-Diagnosis PoweOn's intelligent microprocessor ensures your equipmen is properly protected at all times by self-testing the UPS for reliable operation not only every time the unit is powered on but also every two weeks or over any other time period set by the user. Control from Front Panel or Remote Location PowerOn provides maximum flexibility by allowing the user to control the following important functions from the LCD display or from a remote location: Turn off AC input to perform AC failure test Transfer static bypass switch to bypass loop or back to inverter loop Shut down or restart UPS Clear historical log True RS232 Interface Port PowerOn's true RS232 interface port and proprietary communications protocol provide powerful remote access and remote control capabilities. Fenton's UPSilon 2000 software offers the network administrator convenient, enhanced power monitoring and management capabilities at the touch of a keyboard.
A Total Computer Power Protection and Management Solution Detailed Historical Log PowerOn logs every operating action and abnormal power condition into its memory, allowing you to better understand your power environment and confirm that the UPS is providing valuable protection for your equipment and data. Pure Sinewave Output Fenton's state-of the-art IGBT (Insulated Gate Bipolar Transistor) inverter offers premium performance and efficiency. In conjunction with PowerOn's outstanding control circuitry, the inverter provides clean and pure sinewave power with less than 3% total harmonic distortion under linear load and less than 5% under computer load. Intelligent Battery Monitoring PowerOn's batteries are tested automatically every two weeks by default or over any other period that is configured using the UPSilon2000 software. Once a weak battery is detected, an indicator lights up to remind the user to replace the batteries. Automatic Static Bypass Switch PowerOn utilizes a fast and robust hybrid static bypass switch to reliably handle three times rated current. The switch is automatically activated by overload, inverter voltage out of proper range, and high temperature conditions. It can also be manually activated. When conditions return to normal, the bypass switch is automatically deactivated. Convenient System Power Control Unlike most UPSs which require the load to be turned off when the UPS is initially turned on the user, PowerOn's special constant current circuitry allows the UPS to be turned on while the load is also in the "ON" position. This ability to simultaneously power up the connected equipment by turning on the UPS is a great convenience for applications where the UPS is turned on and off on a daily or frequent basis.
Site Wiring Fault Indicator and Control Improper site wiring can be hazardous and cause equipment damage. PowerOn not only indicates when hot, neutral and ground conductors are mis-wired, it actually prohibits operation until the faulty wiring is corrected. Stylish, Ergonomic Design PowerOn's sleek profile and two-tone finish look attractive in even the most contemporary office environments. And for ease of use and safety, PowerOn features casters and stop level controls. SmartLoadTM Overload and Short Circuit Protection In both utility and inverter modes, PowerOn's intelligent SmartLoadTM circuitry provides advanced protection against damage caused by overloads and short circuits. Overloads are automatically handled according to a precise bypass shutdown procedure that uses a preprogrammed curve to track load against time; while short circuits cause PowerOn to shut itself off instantly to ensure safety and avoid the nuisance and disruption of tripping the house breaker. High Compatibility with Generators PowerOn was specially designed to provide high compatibility with most types of generators, which provide inherently unstable output frequencies. This important compatibility is achieved through the use of dual input and output frequency sensors and our sophisticated PLL circuitry. Long Runtime Applications For customers who require longer battery backup runtimes than the standard PowerOn can provide, Fenton offers two different solutions. Solution #1: Customers can purchase a Fenton external battery bank. These battery banks, which can be connected to a standard PowerOn UPS, feature sealed lead-calcium batteries in an attractive steel case, with convenient built-in charger, circuit breaker, and ventilation fan. Three different models are available. Model No. Battery Tyee Dimensions (W x D x H mm/in.) Built-in Charger Wt. (kg./lb.) BOH26 16 x 12V/26AH 390x680x700/15.4x26.8x27.6 218V/4A 176/387 BOH40 16 x 12V/40AH 390x825x845/15.4x32.5x33.3 218V/4A 272/599 BOH65 16 x 12V/65AH 520x825x845/20.5x32.5x33.3 218V/8A 412/906 The total runtime provided by each of these battery banks when used with a given model of PowerOn, at respective full load of the UPS, is shown in the chart below. Please note that these runtimes represent total system runtime including the runtime provided by the internal batteries in PowerOn and the external battery bank. Runtimes are for reference only and will vary according to operating variables, battery age, and actual equipment load. PowerOn Standard Model BOH26 BOH40 BOH65 H4000 75 Minutes 2 Hours 3 Hours H6000 5 Minutes 1.25 Hours 2.2 Hours H8000 25 Minute 45 Minutes 80 Minutes H010K 25 Minute 35 Minutes 55 Minutes Solution #2: If even longer runtimes are required, customers can purchase special extended runtime versions of PowerOn that come with higher rated internal chargers (and no internal batteries). Customers can then connect PowerOn to their own larger battery banks, sized according to the runtime required. The appropriate extended runtime PowerOn model is determined according to the battery bank AH ratings shown in the chart below. Please note: for very long runtime applications, it may be more economical to use a generator in conjunction with a standard PowerOn UPS. UPS Model H40C1 H40C2 H60C1 H60C2 H60C3 H80C2 H80C3 H10KC2 H10KC3 VA Rating 4000 4000 6000 6000 6000 8000 8000 10K 10K Charger Rating 4A 8A 4A 8A 12A 8A 12A 8A 12A Suggested Battery AH Rating 40-70 70-120 40-70 70-120 120-180 70-120 120-180 70-120 120-180
Intelligent Power Management Power failures can occur at any time, including when they are least expected and most unwelcome. To protect your data and operations at all times, including during unattended use, PowerOn is available with UPSilon2000 intelligent monitoring and automatic shutdown software. During a power interruption, UPSilon2000 broadcasts a warning message to all workstations on the network, urging users to finish up all current tasks. When the administrator is unavailable to shut down the systern during an extended power interruption, UPSilon2000 automatically commences a graceful shutdown of the operating system after a user-configured time countdown or when the UPS batteries become low on power. UPSilon2000 can notify an off-site administrator of the power situation by paging him or her through a modem. Other UPSilon2000 power management functions include scheduling automatic System boot up and shutdown, monitoring the condition of the UPS battery, and logging and analyzing abnormal utility power conditions. Used in conjunction with an SNMP adapter, PowerOn TM and UPSilon2000 are powerful tools for the most sophisticated network administrator. UPS software and hardware accessories: UPSilon2000 UPS Monitoring and Automatic Shutdown software for following OS is included: --- Windows 95, 98, 2000, Me, NT and XP; Linux, FreeBSD and Novell Netware. Software for other operating systems also available. SNMP adapter is optional. Illustration of Internet Application for PowerOn TM Plus SNMP Adapter
Specification MODEL NO. H4000 H6000 H8000 H010K TYPE: Intel Microprocessor-Controlled Fully Intelligent Double Conversion On-Line CAPACITY VA Rating 4000 6000 8000 10K Watt Rating 3200 4800 6400 8000 INPUT Voltage 110,208,220V +20/-20% 208, 220V +20/-20% 1-phase 220, 230; +20/-20%; 240V +15/-25% 120, 240V +15/-25% 240V +15/-25% 3-phase 208/120V, 380/220V +20/-20% Wiring Single phase: L-N+G or split-phase: L-N-L+G 3-phase: Y connection + ground Frequency 50/60Hz +/- 5% tracking range OUTPUT Voltage (on Battery) Single or split phase; voltage same as input nominal; Single phase 208, 220, 230, or 240V related to input Regulation +/-2% upon changes of line or load; with +/-10% adjustable range Frequency 50/60Hz +/-0.5% (free-running) Waveform Pure sinewave; THD < 3% at linear load; < 5% at 0.7 p.f. load Transient Under full load change, recover within 100 milliseconds Synchronization 1Hz/sec. slew rate; Inverter Hz free running when I/P Hz over +/- 5% Crest factor Better than 3:1 BATTERY Lead-acid maintenance-free, life 3-5 years Specification 12V/7AH 16 pcs 12V/17AH 16 pcs 12V17AH 16 pcs 12V/17AH 16 pcs Runtime (full/half) 11 / 24 minutes 20 / 45 minutes 12 / 26 minutes 8 / 18 minutes Recharge to 90% Within 8 hours STATIC SWITCH Hybrid (triac + relay) type with current-limited inrush protection Auto Mode Active when inverter voltage over +/- 10% range, inrush overload, over temperature; auto resume Manual Mode Push control keyboard to manually transfer from inverter to bypass and vice versa Transfer Time 4 milliseconds max. CONTROL PANEL General Microprocessor monitors, controls, and displays system operation status, operation history, and ten alarm messages Control Keys 8 keys to manipulate: 1. Control on/off of AC input or system; bypass loop activation 2. Display operating status & Data 3. Setting of system parameters 4. Alarm silence LCD Display Two line 32 character alphanumerical display provides 1. System operating status (auto display). 2. Data such as O/P Volt., Amp., etc LED Display Utility; On Battery; Inverter O/P; Overload; System Fault; Weak Battery; Out of Sync. COMMUNICATION (DB9) Signals Provides both serial signal for UPS software & contact closure signal for Novell/AS400 application Application contact closure signal provides signal of UPS on/bypass/power failure/low battery PROTECTION Overload 120% 30 mins.; 150% 25 secs. Shortcircuit Cut off outputs of both inverter & bypass, never trips house breaker Thermal Internal thermal switch to protect from over-temperature, then transfer to bypass loop Circuit Breaker Protect AC input & battery loops EMI Filter 10-100Khz at 40dB; 100Khz-100Mhz at 70dB MECHANICAL Dimensions WxDxH (mm/in) 260x600x700 / 10.2x24x28 390x680x700 / 15.4x27x28 390x790x820 / 15.4x31.32.3 Net Weight (kgs/lbs) 96/211 185/407 220/484 280/616 Connection hard-wiring for both input and output Acoustic Noise <50dBA <55dBA <55dBA <60dBA Environment 0-40 degrees C, 0-90% RH non-condensing OPTIONS 1. Intelligent UPS Software Package : consult your distributor for details 2. Long Runtime Modes : 4 amp. charger - H40C1, H60C1, 8 amp. charger - H40C2, H60C2, H80C2, H10KC2 12 amp. charger - H60C3, H80C3, H10KC3 (battery not included)* 3. Input Isolation Transformer for Universal Input Voltage Selection 4. Socket panel for installing U.S. twist-locking sockets. Dimension includes the height of casters. Metapo, Inc Please consult with factory for battery application. The above specification is subject to change without prior notice. Fenton UPS All tradenames mentioned are the properties of their respective owners. 2380 Qume Drive, Suite D * 10KVA requires additional battery bank. San Jose, CA 95129 Product Introduction Tel: (408) 943-9308 Fax: (408) 943-9309 E-mail : support@metapo.com