Emergency Dispatch Console Furniture

Similar documents
Standards for Computer Workstations at Duke Contents

COMPUTER WORKSTATION CHECKLIST

Dual Monitor Sit-to-stand Workstation

FREEDOM CONSOLE. Console and Technical Furniture solutions for the fast pace of 24/7 Command Centers and Mission Critical Operations Centers.

Go from sit to stand, with one touch. Dual Monitor Sit-to-stand Workstation. StarTech ID: BNDSTSDUAL

Product Profile. Links to PROJECT PHOTOS & OPTIONS ALBUMS Inside COMPLETE CONSOLE FURNITURE SOLUTIONS MODULAR UNIT DESIGN CUSTOM COLORS

Operation Centre Desk

Data Centre Peripherals

Lake County Housing Authority North U.S. Highway 45 Grayslake, IL 60030

It s a fact... You should know what you can do to solve your computer-related discomfort.

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic Project Charter Township of Shelby Fire Stations #2 #3 & #4 to Fire Station #1

Sovella Concept Workstation. Solutions A to Z DEDICATED TO HUMAN WORKSPACE.

TechCart TM. quality mobile furnishings designed for a wide variety of work environments

CONSOLE FURNITURE OPTIONS

workstation acessories ErgoChair ergonomic chair designed for the factory worker

Charts + Carts + Accessories

ERGONOMIC WORKSTATION SET-UP CHECKLIST

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

E-SOC CONTROL STATION. TEL: WEB: winsted.com

REQUEST FOR PROPOSAL (RFP) NO Computer Equipment Desktop, Laptops, Chromebooks, Chromeboxes

Knürr Synergy The New Product Family For Uniform Equipment In Your Control Room. Knürr Technical Furniture

Information Technology. Furniture

INVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702)

Technical environment solutions. Profile. Advanced Console System

CONTENDER CONSOLE. Console and Technical Furniture solutions for the fast pace of 24/7 Command Centers and Mission Critical Operations Centers.

Computer Hardware MOUNTING SOLUTIONS

DSE User Checklist. User name Workstation location

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Lincoln County, Georgia. Office 365 & Antivirus

Display Screen Equipment

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

-ADVERTISEMENT FOR REQUEST FOR PROPOSALS-

DSE Workstation Assessment Checklist

STORAGE & ACCESSORIES

TechCart Mobile furniture designed for a wide variety of work environments

Possible solutions, (depending on further analysis)

Passage Desking System

Create extra desk space and tidy up your cubicles

ADDENDUM #1 Boulder Office of Emergency Management Ambulance Services for Boulder County RFS #

Workstations WORKSTATIONS

In this video we are going to see how a personal computer hardware is organised

Sit-to-Stand Workstation

DOCKING STATION SPECIFICATIONS

Genesis Adjustable desk system WASHINGTON STATE CORRECTIONAL INDUSTRIES

Request for Proposals. Information Technology Consultant and Network & Information Technology Support Services

BID SPECIFICATIONS COMPUTER HARDWARE FOR CHARLESTON R-1 BOARD OF EDUCATION CHARLESTON, MO

Table of Contents. 1 Introduction. 2 Facility and Space Planning Requirements

Go from sit to stand, with one touch

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Hosted VoIP Unified Communications Service

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

Trak Mobile TV Stand

MultiTable Electric ModDesk Pro

SECTION 6. COMPUTER ACCESSORIES

Vertiv VR Rack 1.0 GENERAL

PRESTIGE ASCEND CONSOLES PRESTIGE

MERIT SERIES. For Today's Sensible Buyer MANUFACTURED IN THE USA

MESACONTRACT i n c o r p o r a t e d

ViewPoint Monitoring Console System

Mobile Powered Workstations & Accessories Product Overview

Set up dual monitors, side by side or stacked

Contact or for more information.

TV & Office Solutions by equip solutions with a high value of benefit

FOUNDATION DESKS FOUNDATION. Foundation Executive Workstation.

P R O D U C T C A T A L O G

Wall-Mounted Sit-Stand Desk - Single Monitor

BOOKCASES & STORAGE. A place for everything MANUFACTURED IN THE USA

VDU workstation checklist

Request for Proposal Palos Heights School District 128 Network Infrastructure and WIFI E-Rate Form 470: Palos Heights, IL 60463

Applications : LA-51-1 LA-52-1 LA-51-2 LA Features : LA-51-3 LA-52-3 LCD SUPPORTER KEYBOARD ARM

UltraRack. Advanced Data Centre Enclosures SR SERIES

TIER 1 DEPARTMENTAL COMPUTER WORKSTATION EVALUATION FORM UC-DAVIS OCCUPTIONAL HEALTH SERVICES, ERGONOMICS PROGRAM Tel: (530)

FURNITURE WITH INTEGRATED AV AND IT

CONFERENCE ROOMS. Furniture that facilitates collaboration MANUFACTURED IN THE USA

EDUCATION & TRAINING. Engaged in Teaching & Learning MANUFACTURED IN THE USA

Workstation Hutch. Spacious and well-lit workspace.

Collaboration & Video Conferencing

RDM Industrial Products Inc.

Site Readiness Guide. September 2015

Collaboration & Video Conferencing

Purchasing Department Finance Group INVITATION TO BID

ASSEMBLY INSTRUCTIONS

Table of Contents INTRODUCTION STREAMLINE CONSOLE. Overview..1. Overview..2. Features...2. Packing List..3. Assembly.. 4 ~ 6.

M-VIEW MONITOR WALLS. TEL: WEB: winsted.com

SECTION N -- ELECTROSTATIC DISCHARGE (ESD)

Shelves, Keyboard Trays and Gland Plates Folding Shelves

City of St. Louis. Treasurer's Office

CT12. Carl s Table. Its innovative design and usability earned Carl s Table Best of NeoCon 2008, awarded by international leaders in product design.

TH ST N OAK PARK HEIGHTS, MN P F

BID NOTICE FLORISSANT VALLEY FIRE PROTECTION DISTRICT. Robert Corey Chief of Department

CITY OF DERBY. REQUEST FOR BIDS Bid #

iplantables Your Choice! Helping You See the Big Picture Complete Hardware & Software Solutions for

All company and product names are or Registered Trademarks of their respective owners.

Dual Gas Spring Desktop Mount

INSTALLATION INSTRUCTIONS

Classic ipad/tablet Stand Display

Exam Room Solutions. Option A Option B Options C 1 & C 2 C 1 C 2. Option D Option E

PROJECTOR LIFTS CUSTOM E-CATALOG draperinc.com/av

Table of Contents. Overview...2. Features...2. Packing List...3. Assembly...5. Installation...8. Front Panel...9

Transcription:

Request for Proposal Emergency Dispatch Console Furniture Requirements Menominee County E-911 Department s intent is to develop and purchase three (3) standard workstations which will be utilized for Emergency Medical Dispatching of Police, Fire, Emergency Medical Services and other positions within the organization. Vendors and subcontractors must have certificate of liability and workers compensation insurance. Following is a specification that has been developed for the Emergency Medical Dispatching workstations for your consideration and response. This specification was developed with the comfort, safety and productivity of Menominee County E-911 employees as its primary focus, and is not intended to mirror the performance characteristics of a specific manufacturer s product, but to establish performance criteria required to best accommodate a range of users. Any manufacturer s product which meets these performance requirements will be given serious consideration. THIS WORKSTATION SHALL ACCOMMODATE BOTH STAND-UP AND SIT-DOWN POSITIONS IN ONE UNIT SPECIFICATIONS - Sit - Stand Adjustable Height Workstation Stability Function Requires completely separate independent electric floor supported, adjustable work surfaces for both monitor and keyboard. Console must demonstrate stability at full extension. Maximum deflection of ½ is allowed when a horizontal load of 100 lbs. is applied to the center of each work surface. Each work surface (input and monitor) shall have a separate lifting equipment weight capacity of 300lbs. minimum which does not include weight of work surface. Keyboard/Input Surface - Sitting/Standing

Keyboard Surface height requirements are considered paramount to proper ergonomic positioning. All proposers must clearly identify the height range of the keyboard/input surface. Keyboard surface shall have static load capacity of 500 lbs to prevent damage from users sitting / leaning on or using the surface as an aid in standing. Keyboard surface must lower to elbow height dimension (approx. 22") from the floor to the top of the keyboard surface. Keyboard surface must raise to at least standing elbow height (approx.. 46.5") from the floor to the home row of keyboard. o Keyboard Surface width must accommodate multiple keyboards or other input devices and still provide room for note taking on either right or left hand side of 3 keyboards and 3 mice. Monitor Surface - Sitting/Standing Monitor Surface height requirements are considered paramount to proper ergonomic positioning. All proposers must clearly identify the adjustment range of the monitor. Monitor Surface must lower to allow positioning of monitor so that the gaze angle of the seated user to the center of the screen ranges between -15 and -25 from horizontal eye level. Monitor Surface must raise to 48" to allow positioning of monitor so that the gaze angle of the user standing to the center of the screen ranges between -15 and -25 from horizontal eye level Monitor Surface must be wide and deep enough to accommodate up to Six 26 inch LCD flat panel monitors. If monitors are stacked monitor surface must be able to lower below the keyboard surface to maintain proper viewing angles for most users. Monitor surface must be engineered to anticipate the possibility of technicians needing to stand or kneel on console to service equipment and shall be capable of supporting a 500 lb. static load. Laminate Console Tops and Side Surfaces Keyboard, Monitor and fixed height surfaces must be non-glare, high pressure laminate. All corners of input surface must be rounded minimum of 3" radius Console Control Electronics

All electronic control boxes which power the height adjustment of the surfaces shall be mounted in easily accessible location for trouble shooting. Dispatchers and service technicians shall not be required to crawl under consoles and look up at the bottom of the surface. All console control electronics shall be labeled for easy identification. This include cables, electric boxes and pathways. Acoustical Panel System Specified to provide for cable management, visual separation of tasks and both sound barrier and sound absorptive functions. Consoles without panel divider systems do not meet base bid requirements. Panel frames shall be minimum 14 ga. cold rolled steel with powder coat paint finish and slotted uprights to support components at 1 centers or equal. Internal Cable management within the panel frame system is required. Please state your panel frame internal CAT5e cable capacity. Shelving / Rackmount Enclosures Rackmount Enclosures shall have ventilated back panels for heat dissipation. Cable Management Cable pathways must be easy for the tech to access from the front of the console. Consoles which require rear access will not be considered. Monitor and keyboard cables must have separate pathways from the computer to the end point. Supplier shall provide premium quality extension cables as required to connect monitors, keyboards, mice and all devices to CPUs. CPU Enclosures shall be available in sizes to accommodate mini-tower cases up to 8 wide x 18 high and be available in 1, 2, 3, unit capacity. shall be a minimum of 29 deep (deeper is preferred) in order to accommodate CPUs and cabling.

shall have at a minimum of two of the three front, rear and top access points depending on layout. shall have an internal motion sensing LED service light as standard equipment. Rotating Resource Guide Shall be available in 36 or 41 diameter. Capacity to hold 2 levels of 3 ring binders. Shall have a weight capacity of 500 pounds. Rotating Resource Guide shall have the ability to be positioned under a peninsula top style work surface. Adjustable Monitor Rack Parabolic monitor rack shall be curved to match the cockpit shape of the workstation and achieve as close to equal focal lengths from the user s eyes to the face of each monitor as possible and also position monitors for a view angle perpendicular to the screen. Parabolic monitor rack shall be available in various sizes to accommodate up to six 26 inch monitors on a single or dual level. Monitor rack shall be designed to permit stacking of a single monitor up to a complete additional row without removal or disassembly of any existing monitors or any portion of the base unit. Monitor rack shall have simple and clean cable management on the back. Vendor shall supply premium quality cable extensions as required to reach CPUs in CPU cabinets and provide adequate length to extend CPUs for service. Keyboard Surface Data Connection Center (KSDCC) A KSDCC shall be located in the center of the back edge of the keyboard surface to provide an easy, instantly accessible location to plug in keyboards, mice and touch screen monitors if so equipped. The KSDCC shall incorporate an integral wire management channel along the back side of the keyboard surface to provide a place for mouse and keyboard cables to be stored and easily retrieved by the user to re-position keyboards or mice for either

right or left hand use and to prevent cables from hanging down into knee/foot space. Vendor shall supply appropriate number of panel mount extension cables of sufficient length to reach CPUs with each KSDCC specified. Project Administrator: Mailing Address for Project: Brian Barrette, E-911 Director Menominee County Central Dispatch bbarrette@menomineeco.com 839 10 th Avenue (County Administrator s Office) Menominee, MI 49858 (906) 863-6614 Instructions to bidders: Menominee County is currently accepting proposals for two (2) E-911 Dispatch Workstation Units and three (3) E-911 Dispatch Workstation Units (separate proposals). Workstations should accommodate both stand-up and sit-down positions. Itemized pricing should include all materials, hardware, warranties/maintenance agreements and all labor on installation/removal of current workstations. A general scope of the project can be obtained from the Menominee County E-911 Director, Brian Barrette at 906-863-6614 or online at www.menomineecounty.com under Latest News. A mandatory walkthrough of the E-911 Dispatch Center will be held on January 9 th, 2018 at 11:00 AM Any interested vendors must attend the walkthrough. Proposals are to be: Sealed and have the name, address and contact information of the bidder on the outside of the envelope and identified as: E911 Dispatch Workstations. Mailed/delivered by January 19th, 2018 at 3:00 pm To: Menominee County Administrator, 839 10 th Ave., Menominee, MI 49858. Proposal Opening will be held at 5:30 PM on January 22, 2018 at the Menominee County E-911 Governing Board Meeting; Stephenson City Hall/Fire Hall, W628 Samuel St., Stephenson, MI 49887. Menominee County reserves the right to accept or reject any and all bids.

Menominee County reserves the right to: Accept any or reject any/all proposals received; Waive defects, modify irregularities, informalities, or inconsistencies in any proposal received; Select or negotiate with any vendor s, proposal or any portion of a proposal that appears, in the opinion of the Menominee County 911 Department to be most advantageous to the Menominee County 911 Department; Negotiate any aspect of the proposal with any vendor and negotiate with more than one vendor at a time; Increase and/or decrease quantities of individual items based upon line item pricing; Terminate negotiations and select the next most responsive vendor, prepare and release a new Request for Proposals, or take such other action as the Menominee County 911 Department deems appropriate.