Tech Note: Measurement of New Ridge Technologies PMD Sources with Adaptif s A2000

Similar documents
MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Module

Configuration of Light Sources

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Introduction: Experiment 1: Wave Properties of Light

The LLCP series follows the Mueller Matrix design while the LSDP series uses conventional designs

Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017

Raman Spectrometer Installation Manual

Or in the U.S., call Agilent Technologies at (8 am - 8 pm EST)

MonoVista CRS+ Raman Microscopes

OIW-EX 1000 Oil in Water Monitors

POL-001 Fiber-Optic In-Line Polarizer. Operation Manual

Quick Value Statistics in Presentation

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL

Operating instructions - Cary 100 Bio UV-visible Spectrophotometer

40 and 100 Gigabit Ethernet Consortium Clause 86 40GBASE-SR4 and 100GBASE-SR10 PMD Test Suite v0.1 Technical Document

Operating Procedure for Horiba Raman Microscope

CS260 Contractor Series OTDR

STS Spectrometer Getting Started

67 Series Spectrophotometer PC Software

PCD 005 PolaMIX. Operation Manual

Radiance, Irradiance and Reflectance

Considerations on X00 Gb/s 40-80km interfaces with appropriate support for DWDM systems. Peter Stassar HUAWEI TECHNOLOGIES CO., LTD.

LED MINISPECTROMETER LMS-R

DLIT and FLIT Reconstruction of Sources

Spectrometer Visible Light Spectrometer V4.4

UNIT 102-9: INTERFERENCE AND DIFFRACTION

AKELA Vector Network Analyzer (VNA) Quick Start Guide

Alpy 600 Mixed Mode Calibration

Optical Spectrum Analyzer AQ6330. Full featured optical spectrum analyzer with compact and lightweight design

VCSEL-Friendly 1310nm Serial PMD Specifications

WHITE PAPER. How to Generate a Ray Set from an RSMX Source Model. Zemax A Radiant Zemax Company

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Leica 3D Disto PROJECTOR function for stair case applications

Welcome to noiselab Express 1.0

StellarNet Single-Channel SpectraWiz for LabVIEW

Fluorimeter User s Booklet

This presentation takes you through Region of Interest (ROI) Analysis.

Roughness measuring systems m rail trolley m rail m wheel

Introduction to Raman spectroscopy measurement data processing using Igor Pro

Non-scanning Hyperspectral Imaging and Spectral Video Technique for Object Documentation

SUPPLEMENTARY INFORMATION

Agilent 81910A Photonic All-Parameter Analyzer User s Guide

AON Agile Optical Networks Measuring the Optical Signal-to-Noise Ratio in Agile Optical

Solar Module Quantum Efficiency Characterization System (LabVIEW Sheds Light on Solar Cell Quality Improvements)

Agilent 8509A/B Lightwave Polarization Analyzer. User s Guide

OIW-EX Series of Oil In Water Analyzers MiView Handbook Document code: OIW-HBO-0013 Version: EX July 2013

RoHS COMPLIANT 2002/95/EC

Operation Manual of J.A. Woollam Ellipsometer

Time-Resolved measurements by FEL spontaneous emission: A proposal for sub-picosecond pumps & probe structural and spectrometric investigations

Optical Component Test Agilent Multi-Wavelength Meters

AxoStep TM Imaging Mueller Matrix Polarimeter

IgorCD Procedures. Data -> Load CD Data

MassHunter File Reader

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

1. Getting Started: Brief Step-By-Step Guide (PDF File)

Protein Deconvolution Quick Start Guide

AQ6375. "LONG-WAVE" Optical Spectrum Analyzer. Telecom and Beyond QUALITY INNOVATION FORESIGHT

PowerMax-Pro USB and RS Sensors

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

Agilent N5393C PCI Express Electrical Performance and Compliance Software Release Notes

Hyperspectral Chemical Imaging: principles and Chemometrics.

Q Exactive HF-X Software Manual

Open Excel by following the directions listed below: Click on Start, select Programs, and the click on Microsoft Excel.

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

7310 and 7315 Glossary of Icons. Operating Manual

Optical Loss Budgets

PI Scanner User Guide

Multivariate Calibration Quick Guide

A Walk Through the MSA Software Spectrum Analyzer Mode 12/12/09

OPTICAL COHERENCE TOMOGRAPHY:SIGNAL PROCESSING AND ALGORITHM

Stereo DEM Extraction from Radar Imagery Geomatica 2014 Tutorial

dscope Series III Applications Manual - Auto Sequence by Ian Heaton

Optics for nonlinear microscopy

1 Introduction. ThinPrint Client Installation Page 1

FTB-5240S/BP NETWORK TESTING OPTICAL

Instruction Manual of Modelling of Trap Detectors Using Matlab

Agilent 6400 Series Triple Quadrupole LC/MS System

RgBLase LLC P/N: FB 671 XXX Diode Pumped Solid State Laser Module

Instruction for Mass Spectra Viewer

CoSMoS Starter Guide 1.4 Hoskins Lab Last Modified 03/03/2017 Chris DeCiantis

Agilent MassHunter Qualitative Data Analysis

(0, 1, 1) (0, 1, 1) (0, 1, 0) What is light? What is color? Terminology

GeoTASO Project Summary and Relevance. Jim Leitch Ball Aerospace

SystemVue 2011 Fundamentals (version ) LAB EXERCISE 1. SystemVue Basics

Stereo DEM Extraction from Radar Imagery Geomatica 2015 Tutorial

Positioning system of a metrological AFM: design considerations

Leica 3D Disto PROJECTOR in stair case

Training Tracker 6. Release Windows Mobile Software for OPN computer directions, llc 3 Gamecock Avenue Suite 308-A Charleston SC 29407

Theory and Measuring of Antireflection Coatings

Spectroscopic Analysis: Peak Detector

Spectral Color and Radiometry

TTR500 Series Vector Network Analyzers Demonstration Guide

CoSMoS Starter Guide 1.6 Hoskins Lab Last Modified 03/30/2017 Chris DeCiantis

EDX Spectra. Used to set the amount of time for which the spectrum will be acquired (dwell), and to perform the following functions:

37 (15 pts) Apply Snell s law twice (external, then internal) to find it emerges at the same angle.

Cornell Spectrum Imager (CSI) Open Source Spectrum Analysis with ImageJ Tutorial

NMR Training VNMRJ 4.2A/VNMRS 400

X-Lab Pro 5 Operator Manual

ChromQuest 5.0 Quick Reference Guide

Transcription:

Tech Note: adaptif A2000 set up to measure NRT-40133A DGD states Tunable Laser adaptif A2000 PMD measurement NRT PMDS (DUT) Settings at NRT-40133A 1. Calibrate at desired wavelength (e.g. 1550.0 nm) 2. Set to PMD state to (0,0) New Ridge Technologies, LLC +1 443 255 7360 Page 1 adaptif PHOTONICS GmbH +49 40 76629-2160

Settings at adaptif A2000 polarization NAVIGATOR 3. Double-click on PDL/PMD measurement from the Application folder at left of main screen 4. Set Sweep Rate to 5.0 nm/sec 5. Start Wavelength = below the NRT-40133A calibration wavelength (e.g. 1549.5 if calibrated to 1550.0 nm) 6. End Wavelength = above the NRT-40133A calibration wavelength (e.g. 1550.5 if calibrated to 1550.0 nm) 7. Run measurement by pressing on Single Measurement adaptif A2000 Post Processing 8. Set Resolution (nm) to 0.020 or 0.030 For rapidly varying DGD spectra smaller resolution may be necessary to capture all of the features. However, smaller resolution may also increase the measurement noise. This often results in incorrect SOPMD, PDC and/or Depolarization outputs as they are calculated from derivatives of the noisier signal. New Ridge Technologies, LLC Page 2 adaptif PHOTONICS GmbH

Comparison of NRT-40133A DGD state with of ADAPTIF A2000 Measurement Set the NRT-40133A to the desired state, and then measure with the adaptif A2000 ( Single Measurement ). After scanning the PMD state set Y-axis on adaptif A2000 and measure the DGD max and min across the scan. Repeat this for the SOPMD, Depolarization and the PCD on the A2000. The scaling can be changed using the arrow-buttons (automatic scaling) or the tool-button (manual scaling) on the toolbar on the left of the screen: This should match the DGD spectrum on the PMDS (PMDS Tools Spectral and PSP Viewer). New Ridge Technologies, LLC Page 3 adaptif PHOTONICS GmbH

adaptif A2000 set up to measure NRT-10033A DGD states 1. Calibrate at desired wavelength (e.g. 1550.0 nm) 2. Set to PMD state to (0,0). Settings at adaptif A2000 polarization NAVIGATOR 3. Double-click on PDL/PMD measureme nt from the Application folder at left of main screen 4. Set Sweep Rate to 5.0 nm/sec 5. Start Wavelength = below the NRT-40133A calibration wavelength (e.g. 1549.5 if calibrated to 1550.0 nm) 6. End Wavelength = above the NRT-40133A calibration wavelength (e.g. 1550.5 if calibrated to 1550.0 nm) New Ridge Technologies, LLC Page 4 adaptif PHOTONICS GmbH

7. Run measurement by pressing on Single Measurement adaptif A2000 Post Processing 8. Set Resolution (nm) to 0.020 or 0.030 For rapidly varying DGD spectra smaller resolution may be necessary to capture all of the features. However, smaller resolution may also increase the measurement noise. This often results in incorrect SOPMD, PDC and/or Depolarization outputs as they are calculated from derivatives of the noisier signal. Comparison of NRT-10033A DGD state with of ADAPTIF A2000 Measurement Set the NRT-10033A to the desired state, and then measure with the adaptif A2000 ( Single Measurement ). After scanning the PMD state set Y-axis on adaptif A2000 and measure the DGD max and min across the scan. Repeat this for the SOPMD, Depolarization and the PCD on the A2000. The scaling can be changed using the arrow-buttons (automatic scaling) or the tool-button (manual scaling) on the toolbar on the left of the screen: New Ridge Technologies, LLC Page 5 adaptif PHOTONICS GmbH

This should match the DGD spectrum on the PMDS (PMDS Tools Spectral and PSP Viewer), as shown with the NRT-10033A example above. Below is an example and comparison of measurements made on the PMD state (0, 1700) generated by an NRT-10033A. The green data points connected with the green traces were measured employing the Jones Matrix Eigen-analysis measurement technique with an Agilent 8509B. This measurement is time consuming and cumbersome although quite accurate. The blue traces were measured with the Adaptif A2000. The A2000 is capable of much wider PMD spectral scans, in far less time, and provides the same results. On the left side are superimposed JME measurements. The wider blue traces were made with the A2000. On the right side is the NRT-10033A spectral and PSP viewer for the state corresponding to the set state (0, 1700). The A2000 accurately measures the PMD set PMD state. Note the difference between the measured PCD and the set PCD is a factor of 1. After researching into the definition of PCD both Adaptif and NRT agree on the PCD standard shown at the right. New Ridge Technologies, LLC Page 6 adaptif PHOTONICS GmbH