ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

Similar documents
ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

CS485. User s Manual. Version ZYPEX, Inc.

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

User s Manual Pulse Encoder Interface Module OTAC-01

115/230 VAC Digital Input Module OHDI-01

Adapter Kit - Remote QSI Electronics Installation Instructions

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Accessories IC690ACC900

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

TRANSDUCER T4311, T4411

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

Serial Communication Converters & Adapters Instruction Manual

Connecting a Cisco Input Module

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

ICF-1150 Series Quick Installation Guide

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

RS485 MODBUS Module 6RO

DSE2548 LED expansion module INTRODUCTION

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

T2314, T2414. Instruction Manual

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

DATA CONNECT ENTERPRISE

ECL Comfort 296 / 310 controllers Modbus networking guide

Introduction. General Ratings

RS-485 module. Data sheet. for electricity meters

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Dimensional drawings. Dimensional drawings

Manual Fiber Optic Interfaces

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

Carbon Monoxide Sensor - ModBus

T2314, T2414. Instruction Manual

RS 485 Mini Modbus 1AO

RS485 MODBUS Module 8I8O

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MED102A. Industrial Serial to Single-mode Fiber Converter

RS485 MODBUS Module 8AO

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Remote announciator igl-ra15

Advanced Visual Solutions Ltd

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

DESIGN GUIDE FOR INFINITY SYSTEMS

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

vacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives

IFC 100 Supplementary instructions

Integrity Instruments

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Two Door Controller GEN-045

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

MODEL DRIVER Ic Ip VDC

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

PROFIBUS-DP/MODBUS RTU REPEATER

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

205 CPU NETWORK ADAPTER F2-UNICON

ICF-1150 Series Quick Installation Guide

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

Quadrature Encoder User's Manual. Specification and Installation Guide. NetLinc, TLAser400 & PTRBe. Oct 2015

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

icex-cmtm General specs and Installation guide

MOTION COORDINATOR MC405 Quick Connection Guide

ABB general machinery drives ACS350, 0.5 to 10 hp

Submittal Data Sheet WAGO Node for itm

RTU560 Remote Terminal Unit Connections and Settings

RS485 MODBUS Module 8I8RO

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Belimo Gateway MP to Modbus RTU - UK24MOD

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

ABB low voltage drives

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

Installation & Operation Guide

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

BACnet Protocol Converter Kit for Use with Bacharach MultiZone Gas Monitors. Installation Manual

Resolver to Digital Expansion Board

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Environdata FA ma Converter Guide

Transcription:

ABB Drives User s Manual RS-485 Adapter Board FRSA-00

Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1 Mechanical Installation... 2 2.2 Electrical Installation... 3 2.3 Bus Termination... 3 2.4 Drive Parameter Settings... 4 2.5 RS-485 Network Configuration... 4 3 APPLICATION GUIDELINES... 5 3.1 Overview... 5 3.2 RS-485 Network Topology... 5 3.3 Application Guideline Summary... 8 1

1 INTRODUCTION 1.1 Overview This section contains a description of RS-485 adapter board. The FRSA-00 RS- 485 Adapter Board and the FMBA-01 Modbus RTU Adapter Module are both used to support the ACS350 Modbus-RTU communication protocol. 1.2 Technical Data of RS-485 Link Medium: Shielded twisted pair cable, impedance 100 to 150 ohms Termination: 120 ohms (FRSA built in) Topology: Trunk line, drop lines allowed Transfer Rate: 115.2 kb/s maximum Serial Communication Type: Asynchronous, half-duplex RS-485 Protocol: Modbus-RTU 1.3 RS-485 Bus Topology RS-485 is a physical layer of a two-wire, half-duplex, multipoint serial connection. The FRSA-00 and the FMBA-01 both support two-wire + ground RS-485 networks. A RS-485 networks requires an applied voltage between -7 to +12 volts DC for proper operation. The purpose of the ground wire is to connect the RS-485 signal ground of each node to one common ground potential. As the total distance of the network increases, there can be significant differences in the voltage level of ground. If the sum of the ground-voltage difference and the differential-data signal is greater than the specified applied voltage, network data could be lost; and/or damage to the RS-485 communication port and/or the drive I/O could result. The proper method to install an RS-485 network can be found in the industry standard Publication TSB89, Application Guidelines for TIA-EIA-485-A. This standard can be ordered online at http://www.tiaonline.org/standards/catalog/ See Figures 2 & 3 for the basic guidelines for wiring an RS-485 network, with recommendations for shielded twisted-pair cabling and correct location of termination resistors. Figures 4 6 are examples of various RS-485 network configurations. 2 INSTALLATION 2.1 Mechanical Installation (Refer to Figure 1) 1) Remove the drive s terminal cover. 2) Remove the option board fastening screw from the drive. 3) Use the standoff supplied with the FRSA kit and the screw removed in step 2 to mount the FRSA board. 4) Tighten the FRSA fastening screw. 5) Install the clamping plates 6) Replace the drive s terminal cover. 2

1 2 3 4 5 6 Figure 1 2.2 Electrical Installation FRSA CONNECTION (Table 1) X1 DESCRIPTION 1 SHLD Bus cable shield 2 DATA_B Data positive 3 DATA_A Data negative 4 GND_B Signal Ground 1 Note 1: GND_B terminal does not provide galvanic isolation from the drive I/O. Terminal 4, GND_B is at the same potential as the drive I/O ground.. This difference makes the FMBA-01 the ACS350 Modbus solution for applications requiring long network cable distances with possible ground potential differences between the serial connection and other drive I/O.A ground potential difference outside of the allowable applied voltage of -7 to +12 VDC can damage both the FRSA-00 communication port and the drive s I/O terminals. 2.3 Bus Termination Bus termination is required to prevent signal reflections from the bus cable ends. The FRSA board is equipped with the internal bus termination, which is configurable with jumper J1 pins. Termination should be activated on devices located at bus ends and deactivated on other devices. See the Figures below. 3

2.4 Drive Parameter Settings See the drive manual for the serial communication settings. 2.5 RS-485 Network Configuration Figure 2 Figure 3 ALTERNATIVE RS-485 WIRING WITH SHIELD TERMINATED AT EACH NODE ACS350 FRSA-00 RS-485 ACS350 FRSA-00 RS-485 J1 120 Ω Termination Resistor Activated J1 X1 X1 1 2 3 4 1 2 3 4 Note: Drawing shows connectivity only. Use Belden 9842 cable or equivalent. Belden 9842 cable is a dual twisted pair cable with a wave impedance of 120 Ω. Connect both wires of second twisted pair to ground. 120 Ω Termination Resistor Deactivated 120 Ω Termination Resistor Activated RS-485 MASTER CONTROLLER 4

3 APPLICATION GUIDELINES 3.1 Overview This section provides examples of different network topologies and provides suggestions to apply the best ABB Modbus RS-485 solution for the ACS350. Since, the FRSA-00 is not galvanically isolated from the ACS350 I/O terminal ground. Special considerations need to be made when applying the FRSA-00. In comparison, the FMBA- 01 adapter module provides galvanic isolation from the drive I/O, isolating the serial communication ground from the I/O ground. This difference makes the FMBA-01 the ACS350 Modbus solution for applications requiring long network cable distances with possible ground potential differences between the serial connection and other drive I/O. 3.2 RS-485 Network Topology Figure 4: Is an example of a single enclosure network configuration with a common ground point and all network nodes are in close proximity to one another. This is an example of a network configuration where the FRSA-00 or the FMBA-01 could be applied. Figure 4 5

Figure 5 GND NEG POS SHLD Figure 5: Is an example of a multiple enclosure network configuration. Each enclosure has a unique connection point to ground. If the maximum ground voltage difference is within the allowable range of -7 to +12VDC the FRSA-00 or the FMBA-01 could be applied. If the ground voltage difference may deviate outside of the allowable range the FMBA-01 should be used. 6

Figure 6 Figure 6: Is an example of a multiple enclosure network configuration utilizing both the RS-485 port and drive I/O. Each enclosure has a unique connection point to ground and multiple power sources. This is an example of a network configuration where the FMBA-01 should be applied. 7

3.3 Application Guideline Summary This section is a summary of Figures 4 6 and can also be used as a guideline to determine the best ACS350 Modbus solution for a specific network configuration. This table should only be used as a guide. Each installation needs to be evaluated and tested. Table 2 RS485 Network Guidelines: Selecting FRSA or FMBA Installation FRSA-00 FMBA-00 Application requires both drive I/O and communication NO YES port Application requires no drive I/O YES YES Communication network is compact. (see system drawings for examples) YES YES These application guidelines should be used as a guide to determine the best ACS350 Modbus solution for your specific network configuration. Following these guidelines and implementing reliable engineering and installation practices will significantly improve the reliability of the network. However, the suggestions in this manual do not guarantee a reliable and robust network. 8

Notes: 9

3AUA0000019066 REV. A/ EN Effective: 06/18/2007 ABB INC. Low Voltage Drives 16250 W. Glendale Drive New Berlin, WI 53151 Telephone (800) 752-0696 Fax (800) 785-0397 Internet http://www.abb.us/drives http://www.abb-drives.com