TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

Similar documents
FEATURES DESCRIPTION MODEL 110B. Power Supply

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

REX F-0-9 Standalone or Access Controller

IEI emerge MicroNode Install and Setup Guide. Contents

Connecting a Cisco Output Module

Connecting a Cisco Reader Module

Connecting a Cisco Input Module

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

UC-2000 Installation Manual Unicorn Computers Technology Limited

Installing the DX LCD Display

Access Terminal IF-800

TruPortal Dual Door Interface Module Quick Reference

RBR-SB-KTZ001 LAR 2. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Number of optical axis

CM-110SK Standalone Keypad Installation Instructions

Quick Start Installation Guide

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Digital Keypad Introduction

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

EL-ST100 KEYPAD CONTROLLER

DOLXFD1000B. Waterproof Access Control/Reader

Operating instructions. Speed monitor D / / 2014

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

LON Module for Variable Speed Drive

MIC-2 MKII, Multi-instrument DATA SHEET

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Stand-alone Proximity Access Control

BA/BS4S Temperature Sensor Installation & Operating Instructions

IPassan Installation guide

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

APP 700 Technical Specification

IF-80x Outdoor Terminal

Content. Product Description

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

USB 2.0 CAT5E/6/7 EXTENDER

Excel Smart I/O Compact

CP150B Vandal & Weather Resistant Keypad Security Systems

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

LTEC Heat Pump DDC Controller

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

USB 3.1 CAT6A/7 EXTENDER

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

User Manual. PCKeypad Wireless Keypad

Operating instructions. Switching amplifier DN0210 DN / / 2015

Pen Drive USB Datalogger!

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Magnetic Style Safety Interlock Switches

Access control panel U-Prox IC E (Elevator control)

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

NS1 Connection Unit Guide

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Fingerprint Access Control F1. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RТTH DUAL ROOM SWITCH

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

FX06 Field Controller

Waterproof. Keypad/Reader/Controller

1.5 Solid State Relays

W3-H Waterproof Keypad/Reader/Controller

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

VIDI-AC-2CS Access Controller/ Reader

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Voice Alarm System VX-3000 Series

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

Voice Alarm System VX-3000 Series

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Quick Start Installation Guide

HI SEC Integrated Systems

Classification Enclosure rating Input voltage Type of

DS A 10/99 MN 500 I/A SERIES MICRONET MN 500 CONTROLLERS APPLICATION SPECIFICATION

Back Mount SIP Access Control Intercom Installer s Guide

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Two Door Controller GEN-045

USER MANUAL. 621T DVI Optical Transmitter. 621R DVI Optical Receiver MODEL: P/N: Rev 8

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

PR602LCD v1.0 Installer Manual Rev. A

Room unit with PPS2 interface

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

FX Input/Output (I/O) Modules XM07 and XM14

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Operating instructions. Standstill monitor A / / 2011

Transcription:

TKL19 (RTUL19) Installation Manual Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

CONTENTS 1.1 Wall Set Up for the Cable Trays... 3 1.2 Electrical Connections... 4 1.3 LONWORKS Data Cables... 6 1.4 Mounting the Wall Bracket... 7 1.5 Cable Connections... 8 1.5.1 LON Cable... 8 1.5.2 Power Supply Cable +12VDC... 9 1.5.3 Input Cable 1 Door Contact... 10 1.5.4 Input Cable 2 - Button... 11 1.5.5 Output Cable Relay 1- Door Open... 12 1.5.6 Output Cable Relay 2 Signal Light... 15 1.6 Mounting the Device on the Wall Bracket... 17 1.7 Identification Using the Service Pin... 18 1.8 Identification Using the Neuron ID... 19 2.1 TemaKey TKL19 (RTU-L19 code 1500154xx)... 20 2.1.1 Supplied Parts... 21 2.1.2 Optional Parts... 21 2.2 Recycling... 22 Page 2 of 24

PREPARATIONS 1.1 Wall Set Up for the Cable Trays The cables must: 1) Protrude from the wall. 2) Come out at 120cm from ground (see Figure 1) (advised). cable tray cables 120 cm Floor Figure 1: Wall Set Up for the Cable Trays Version: 1.0 EN Page 3 of 24

1.2 Electrical Connections The RTU is powered at low voltage (12VDC 160mA), preferably using a power supply module with battery backup (RTU-Qxx), or using an ordinary power supply having the same characteristics. The power cables must be dimensioned as indicated in the table below. The maximum allowable voltage drop on the power cable is 1V. Cable length(m) = 1V / (I[A] load x 2 x (res [Ohm/km] /1000)) Cabl e Type AWG mm2 ohm/ Km 160 [ ma] 320 [ ma] 12 3. 3 5. 7 548 274 14 2 8. 8 355 178 16 1. 3 14 223 112 18 0. 9 21 149 74 20 0. 6 34 92 46 22 0. 35 52 60 30 24 0. 2 85 37 18 Ext ensi on [ m] based on l oad The device is equipped with 2 non-removable cables of 2m length: Two-pole, twisted, unpolarized cable dedicated to the LON line connection - LON a 0,325 mm 2 white - LON b 0,325 mm 2 orange Ten-pole cable, providing the following signals: - +12VDC 0,34 mm 2 red - GND 0,34 mm 2 black - INPUT 1 + 0,22 mm 2 green / white - INPUT 2 + 0,22 mm 2 gray / green - RELAY 2 contact C 0,22 mm 2 brown - RELAY 2 contact NC 0,22 mm 2 white - RELAY 2 contact NO 0,22 mm 2 blue - RELAY 1 contact C 0,56 mm 2 green - RELAY 1 contact NC 0,56 mm 2 yellow - RELAY 1 contact NO 0,56 mm 2 gray The signals must be connected using a shunt box with IP protection level in conformance with the type of environment in which it is to be used: - IP55 for moist environments - Recessed box or IP31 at least for inside installations The shunt box must be positioned within the perimeter controlled by the access control system. Page 4 of 24

If necessary, the repeater relays must be inserted inside the box for electrical locking commands and the signal light. 2-pole LON cable 4 mm diameter 2 metri 6,10 cm 8,00 cm Figure 2: Position and dimensions of the non-removable cables Shunt Box 2 meters 4,20 cm Cable +12VDC Cable LON Cable IN 1 Cable IN 2 Cable OUT 1 Cable OUT 2 RTUL19 15,60 cm 7,20 cm 10 pole cable 8.6mm diameter Figure 3: Shunt Box Page 5 of 24

1.3 LONWORKS Data Cables The LONWORKS 1 data cables must be double twisted-pair cables In a free topology configuration, the overall length of the sections must not exceed 500m In a bus configuration, the overall length of the sections must not exceed 2700m In the free topology configuration, the 50ohm terminator must be enabled by inserting the appropriate jumper into the FTT10A plug-in on the CTU- PLG06 board inside the TemaServer In a bus configuration, two terminators must be inserted at the two ends of the bus (resistance of 100ohm 1% ½W) The LONWORKS 1 data cables must be dimensioned according to the indications in Table 1 Cable Type Extension [m] based on cable capacitance AWG mm 2 Ohm/Km 50nF/Km 100nF/K 200nF/K 500nF/K 1uF/Km m m m 12 3.3 5.7 2676 1892 1338 846 598 14 2 8.8 2153 1523 1077 681 482 16 1.3 14 1707 1207 854 540 382 18 0.9 21 1394 986 697 441 312 20 0.6 34 1096 775 548 346 245 22 0.35 52 886 626 443 280 198 24 0.2 85 693 490 346 219 155 Table 1: Length/Capacitance of LONWORKS 1 Cables The FTT10A Echelon v1.2 User s Guide suggests using the cables as indicated in Table 2. Make and Model AW G Bus Connection Max Length total [m] Free Topology Connection Nodeto-Node Max Length [m] Free Topology - Connection Max Length total [m] Belden 85102 16 2700 500 500 Belden 8471 16 2700 400 500 Level IV (twisted pair, 22 1400 400 500 solid, unshielded) JY (St) 2x2x0,8 (4 solid wires, spiraltwisted, shielded) 20 900 320 500 TIA Cat5 / 900 250 450 Table 2: Suggested LONWORKS Cables 1 LONWORKS is a trademark of the Echelon Corporation Page 6 of 24

1.4 Mounting the Wall Bracket Mount the bracket onto the wall as follows: 1. Placing the bracket against the wall to indicate the proper positions of the holes, make the holes for the two bolts that will go into the wall to hold the bracket (the bolts are included in the installation kit) 2. Make sure that the cable tray bathces with the hole for the passage of the cables 3. Screw in the bolts. Hole for Cables Hole for inserting bolt and screw to press against the anti-removal/anti-open tamper Holes for wall mounting Figure 4: Wall Bracket: Front View and Side View Page 7 of 24

1.5 Cable Connections 1.5.1 LON Cable 2 meters 6,10 cm LON A LON B Note: connection not polarized Figure 5: LON (1) Cable Connection Page 8 of 24

1.5.2 Power Supply Cable +12VDC 2 meters 6,10 cm 12VDC (red) GND (black) Figure 6: Power Supply Connection Page 9 of 24

1.5.3 Input Cable 1 Door Contact The balanced input 1 is dedicated to door status control; the balancing resistances must be positioned near the clean sensor contact. IN1 (green / white) magnetic door contact White NC CONTACT Yellow GND (black) Figure 7: Connection for Balanced Input 1 Door Contact Page 10 of 24

1.5.4 Input Cable 2 - Button Balanced input 2 is dedicated to status control of the Open button; the balancing resistances must be positioned near the clean contact of the button. IN2 (green / gray) button contact White NO CONTACT Yellow GND Figure 8: Connection for Balanced Input 2 - Button Page 11 of 24

1.5.5 Output Cable Relay 1- Door Open The Relay 1 output is used for door control. It makes both NO and NC contacts available. The external load can be powered directly by AC or DC, in accordance with the following limits: - Minimum Load: 12VDC / 10mA Voltage Working Current Peak Current max 0.5 Sec (inductive load) Suppressor 12VDC 3A 10A 1N4004 Diode 30VDC 2A 10A 1N4004 Diode 42VDC 0.5A 7A 1N4004 Diode 42VAC 0.5A 7A MOV 75Vrms Inductive load with direct current: In this case it is mandatory to use the 1N4004 diode, which is provided, (or an equivalent) in parallel to the coil of the electrical locking device, to increase the life of the relay inside the RTU see Figure 9. Inductive load with alternating current: In this case it is mandatory to use the MOV (75VAC), which is provided, (or an equivalante) in parallel to the coil of the electrical locking device, to increase the life of the relay inside the RTU see Figure 10. Life: assuming the relay is activated 200 times a day and that the voltage/current limits of the preceding table are respected, the life is guaranteed for at least 6 years; if the relay is activated less frequently, the life of the relay increases proportionally. In case of excessive use (> 200 operations / day) it is suggested to use an external relay. Page 12 of 24

VEXT _+VDC 1N4004 Diode Transient Suppressor Green = C Yellow = NC Gray = NO VEXT_GND coil for electrical locking device/repeater Relay 1 Figure 9: Connection for Output Relay 1 (NO) Door Open DC Voltage VEXT _Vac2 VEXT_Vac1 Mov75Vac Soppressore di transienti Green = C Yellow = NC Gray = NO Bobina elettroserratura / relè di ripetizione Rele 1 Figure 10: Connection for Output Relay 1 (NO) Door Open AC Voltage Page 13 of 24

1.5.5.1 Using an External Relay In case of excessive use or use under elevated current or voltage, you must insert a relay capable of supporting the load for a higher number of operations. The coil for the repeater relay must always be equipped with transient suppressors, as can be seen in Figures 9 and 10. It is also suggested to use a transient suppressor on the load in order to prolong the life of the external relay. Mov75Vac Transient Suppressor Vac coil for electrical locking device/repeater NC NO Vac C VEXT _relay VEXT_relay coil for repeater relay Transient Suppressor: Vext AC = Mov75Vac Vext DC = diodo 1N4004 Relay 1 Figure 11: Connection for Output Relay 1 (NO) External Relay Page 14 of 24

1.5.6 Output Cable Relay 2 Signal Light Output Relay 2 is used for signaling the status of the door (gateway occupied / free ) and provides both NO and NC contacts. The external load can be powered directly from AC or DC power, in accordance with the following limits: Voltage Working Current Peak Current (max 0.5 Sec) Suppressor 30VDC 0.5 A 2 A 1N4004 Diode 30VAC 0.5 A 2 A MOV 75Vrms Inductive load with direct current: In this case, it is mandatory to use a repeater relay and a 1N4004 diode in parallel to the coil for the electrical locking device in order to increase the life of the relay inside the RTU see Figure 12. Inductive load with alternating current: In this case, it is mandatory to use a repeater relay and the MOV (75VAC) in parallel to the coil for the electrical locking device in order to increase the life of the relay inside the RTU see Figure 13. Life: assuming the relay is activated 200 times a day and that the voltage/current limits of the preceding table are respected, the life is guaranteed for at least 6 years; if the relay is activated less frequently, the life of the relay increases proportionally. In case of excessive use (> 200 operations / day) it is suggested to use an external relay. Page 15 of 24

Signaling Device (LED) VEXT VEXT Relay 2 Brown = C White = NC Blue = NO Figure 12: Connection for Output Relay 2 (NO) Resistive Load AC/DC Voltage Mov x Vac Transient Suppressor NC NO Vac_lamp C VEXT_relay coil for repeater relay Transient Suppressor: Vext AC = Mov75Vac Vext DC = diodo 1N4004 Vac_lamp Brown = C White = NC Blue = NO VEXT _relay Relay 2 Figure 13: Connection for Output Relay 2 (NO) Inductive Load Repeater Relay Page 16 of 24

1.6 Mounting the Device on the Wall Bracket Figure 14: Mounting 1) The RTUL19 is positioned atop the wall bracket protrusion 2) The back part is aligned with the wall by rotating 3) The RTUL19 is mounted onto the bracket using screws Page 17 of 24

ACTIVATION 1.7 Identification Using the Service Pin To identify the node, you can call the service pin using the relay-reed found inside the device (see Figure 15). Use the following steps for this procedure: 1. Place a small magnet as indicated in Figure 15 to call the service pin. The signal is linked to the yellow service LED (at the center), which will blink throughout the operation. 2. The TemaServer will send a wink command in response to the service pin, which lights the yellow LED and the buzzer three times. This allows you to verify that communications are operational to and from the TemaServer. 3. Check to see that the service LED is off at the end of the operation. Position of magnet The LED goes yellow Figure 15: Calling the Service Pin Using a Magnet Page 18 of 24

1.8 Identification Using the Neuron ID The label with the neuron ID that comes with the kit must be applied by the installer on the appropriate identification sheet. You also must indicate the location of the terminal in the appropriate box (see example in Table 3). Description of Location Entrance to Offices, First Floor, Stairway E Description of TemaServer Panel2, Entrance, First Floor, Stairway E RTUL19 Table 3: Example of Compiled Identification Sheet Page 19 of 24

2 TECHNICAL DATA 2.1 TemaKey TKL19 (RTU-L19 code 1500154xx) Parameter Value Power Supply 12V DC ±15% 100mA nominal (1.4W), 160mA max (2W) Weight 0.3 kg Dimensions Degree of Protection Operational Temperature 156 Lu x 40 La x 27 sp mm IP55-20 to 60 C Storage Temperature -20 to 70 C Relative Humidity of Storage LED 0 to 95 % without condensation 1 LED tricolor Red / Green / Yellow Buzzer 1 Inputs 2 balanced inputs with 4 statuses: normal, alarm, cut, short Output Relay 1 Electrical Locking Device Command Contacts: C / NC / NO (see page 12) Output Relay 2 Antenna proxy LONWORKS 2 Connection Conformance to Norms Lamp Command Contacts: C / NC / NO (see page 15) 125KHz for HID cards reading distance 0 to 40 mm (MD-15W internal controller) "Free Topology" type connected with unshielded double twisted pair cable FT3120 Smart Transceiver, 78Kbps Directive EMC 89/336/EEC, 92/31/EEC, Low Voltage Directive 72/23/EEC, 93/68/EEC: EN60950 / EN55022-B / ETSI EN300-330 / EN55024 2 LONWORKS is a trademark of the Echelon Corporation Page 20 of 24

2.1.1 Supplied Parts KIT of resistances for input balancing Fisher bolts for wall mounting Fisher bolt for tamper 1N4004 Diode 2 MOV 75Vrms 2 2 White resistances 2 Yellow resistances 2 (S4 type) + screws 1 (S4 type) + screws 2.1.2 Optional Parts TORX TX10 Screwdriver Code 1500108AA Page 21 of 24

2.2 Recycling In application of directive 2002/96/EC regarding electrical and electronic waste devices, in vigor from 13 August 2005, Honeywell engages, when requested by the customer, to the collection, treatment, recovery, and proper disposal of all devices produced. All users within the European Union are hereby informed of the requirement for the proper elimination of the product as regulated by laws, rules, and local procedures. Page 22 of 24

Notes: Page 23 of 24

Figure 16: Temakey TKL19 Page 24 of 24