PACSystems* IC698ACC701C

Similar documents
PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PSA140

PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

PACSystems RX3i IC695PSA140

PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

PACSystems RX7i IC698CHS009/119

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

A PACSystems RX3i Ethernet NIU I/O Station

IC693PWR331 High Capacity Power Supply, 24 VDC Input

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

PACSystems RX3i IC695HSC304 and IC695HSC308

Programmable Controller IC697ACC721/724/744

Installation Instructions

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

PACSystems* RX3i IC695ACC650

GE Fanuc IC695CMM004. Rx3i PacSystem

GE Intelligent Platforms

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX7i IC698CMX016-ED

PACSystems* RX3i IC694ALG233

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

This Datasheet for the IC693ACC301. Replacement Battery, CPU & PCM (qty 1)

This Datasheet is for the IC693ACC301. Backup Battery for RAM Memory.

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Discrete Output Modules

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

PACSystems* RX3i 1GHz 64MB CPU w/ethernet IC695CPE330 Quick Start Guide GFK-2941J November 2018

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

1. CP430, CP470, CP474, CP770 and CP774

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Installing and Configuring Rialto Analytic Appliances

PACSystems* RX3i IC694ALG232

Instructions to printer DO NOT PRINT THIS PAGE

Allen-Bradley Motors

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

IC693 PLC IC693ACC350, IC693ACC340/341

This document provides information on: important pre-installation considerations installing the memory cartridge replacing the battery specifications

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

P USB 2.0 (Type B) Port - Programming - Online monitoring

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MGate 5105-MB-EIP Quick Installation Guide

Toughbook. CF-C1 MK1 refurbished. Table of Contents:

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Intel RAID Smart Battery AXXRSBBU6

PACSystems RX3i IC695CPU310. Features. Ordering Information. Central Processing Unit. GFK-2329T December 18, 2007

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

PACSystems RX3i IC695CPU310. Central Processing Unit. Features. Ordering Information. GFK-2329AC May 2011

VersaMax IP. Proficy Machine Edition. Publication Reference Chart

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

SUBCON-PLUS-PROFIB...

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

27MG Ultrasonic Thickness Gage Getting Started Guide

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

MGate 5111 Quick Installation Guide

PACSystems* RX3i IC695PBM300

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

PACSystems* RXi ICRXIBN0E000A and ICRXIBN0M000A

EC Series. Safety Guide

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PACSystems RX3i IC695CMU310

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Power. Document Part Number: This guide explains how the computer uses power. March 2006

Installation and Wiring

PHOENIX CONTACT - 05/2007

Power Supplies IC697PWR724/CE697PWR724

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

PAC BI-PN-05, 8516-BI-PN-05 and 8752-CA-NS-01

Accessories IC690ACC900

The Solid-State Decoupler (SSD)

Chapter 1. Introduction. Additional Documentation

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

PanelView 600 Terminals

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

4.1 General. 4 Replacement Procedures

FLEX Ex Spring Clamp Terminal Base

MegaRAID SAS i and SAS i RAID Controllers

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

MobilePro Users Guide Page 1 of 35. MobilePro HPC. User's Guide. Notices Proprietary Notice and Liability Disclaimer Table of Contents

RSTI-EP Slice I/O. Digital Output Module

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Residential/Light Commercial Remote Control System

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

This Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Installation & Operation Manual

PROFIRE 3100 User Interface Assembly

Transcription:

May 2011 PACSystems* IC698ACC701C Smart Coin Cell Battery The IC698ACC701C coin cell battery pack is an enhanced version of the IC698ACC701B battery pack. In addition to providing standard memory backup for PACSystems CPUs, the smart coined cell battery pack has a battery monitoring circuit that enables the user to detect the Low Battery state in advance before it is completely drained. Pre-installation Check Upon receiving the battery pack, verify the package contents, which include the following: IC698ACC701C (or later) Smart Coin Cell Battery pack having cable with four-pin female JAE connector Enabling adapter cable with four-pin male to two-pin female connector Date Code The date code is located on the product label at the right bottom edge. The date code consists of four digits, such as 1011. The first two digits represent the year of manufacture in the 21st century, such as 10 for the year 2010. The last two digits represent the fiscal week of manufacture for the indicated year; for example 11 stands for fiscal week 11.

2 Smart Coin Cell Battery Installation 1. While installing the battery to the CPU, first connect the four-pin Male JAE connector on the enabling adapter cable to the female four-pin JAE connector on the battery pack as shown in the following figure. (Installing the four-pin connector enables the battery.). Note1: The battery will begin to drain immediately if attached to the CPU in Power OFF condition. To maximize battery life, it is recommended that you install the fresh battery after power has been turned ON to the attached CPU. Note2: Once the enabling adapter cable is connected, the battery starts to drain, even if it is not attached to the CPU. So, it is recommended to disconnect the enabling adapter cable from the battery pack when the battery is not in use. Even though the discharge current would be negligible with just the enabling adapter cable connected, this can affect Battery life if left in this condition for long durations.

Smart Coin Cell Battery 3 2. Connect the two-pin female connector of the enabling adapter cable to the CPU battery terminals. PACSystems RX3i Run the battery cable into the notch at the bottom of the battery compartment and close the battery door. PACSystems RX7i Run the battery cable through the slot on the battery door and reinstall the battery door. An earlier version of the RX7i CPU may not have a notch in its battery door. For these CPUs, replace the door (supplied with the IC698ACC701 replacement battery) Slot in battery access door BATTERY ACCESS Be careful not to pinch the battery cable when closing the battery compartment cover. EXPLOSION WARNING: Do not install or replace battery pack unless the area is known to be nonhazardous. Safe Handling and Disposal For Safe handling and disposal of dead battery modules, reference the manufacturer s Material Safety Data Sheet (MSDS) and the Battery Disposal Document that are included with this product. WARNING: Risk of fire, explosion, and burns. Do not short-circuit, crush, incinerate, or disassemble battery.

4 Smart Coin Cell Battery Specifications Battery capacity Parameter Lithium (Li) content Physical dimensions Weight Connection Connector Assembly Operating temperature range 3.0 Amp-Hours Specification 0.87 Grams (3 cells @0.29grams/cell) 3 long x 1.059 wide x 0.4822 high (76.2 x 26.92 x 12.25mm) 29.94 grams 2 (50mm) twisted red/black 22 AWG, Rated 80 C leads with female 4-pin JAE connector. 2 (50mm) twisted Red/Black 22AWG with four-pin male to two-pin female adapter cable for compatibility with battery connectors on PAC Systems CPUs. Included in the Battery Pack 0 to +60ºC Nominal shelf life 5 years at Storage temperature of 20ºC Nominal Memory Backup Life* The battery pack retains dynamic data in the controller SRAM and is only active when the system is not powered up. The number of days in the Nominal Battery Backup Life table below represents the approximate number of days the battery will back up the SRAM during times only when the CPU is not powered. Example: If the CPU is powered down only on weekends, the Battery will last 63 days in Good State and 52 days in Low State. The total battery life will be approximately 115 days before it should be replaced. Unscheduled power outages and temperature changes will reduce the number of days and should be considered when calculating the duration of the battery life. CPU Model PACSystems RX3i IC695CPU310, IC695CMU310 PACSystems Rx7i IC698CPE010, IC698CPE020, IC698CRE020 Battery Back-up Life in Good State Battery Back-up Life in Low State Total Back-up Battery Life 18 days 15 days 33 days 15 days 15 days 30 days *The nominal backup values are estimated at 20ºC. Backup time increases approximately 17% at 60ºC and decreases approximately 32% at 0ºC. Note: The CPU detects the low battery condition only while the CPU has power. If a low battery condition occurs while the CPU is powered down, the CPU logs a Low Battery fault upon powerup as soon as it detects the signal from the smart battery. However, because the current drain on the battery is negligible with the CPU powered up, logging of a Low Battery fault is not likely to occur, unless a good battery is replaced with a low battery while the CPU has power. This would indicate to the user that a good battery has been accidentally replaced with a depleted battery. The Battery LED or the fault table indicates the battery status. For details on the operation of specific CPU models, refer to the PACSystems CPU Reference Manual, GFK-2222.

Smart Coin Cell Battery 5 Smart Battery Operation The battery output voltage is > 2.5 V when the battery is operating in its good state. At the end of the battery good period, the battery output drops to <2.5 V for the battery low state. The period for the battery low state is 15 days for all CPU models. Once battery output voltage drops to <2.5V, the PACSystems CPU detects this as a battery low condition, a Low Battery fault is logged in the CPU fault table and the Battery LED on the CPU starts blinking in red(depending upon the CPU). Once the battery low state is active, the user has 15 days of accumulative battery backed energy left for CPU RAM retention during power loss. If the battery is not replaced within 15 days of accumulative power loss, the CPU RAM memory contents will be lost as the battery output voltage drops to 0V. If the Battery Low condition occurs when the controller is in the Power OFF state, a low battery fault will be logged in the Fault table only at the time when the controller is powered ON. The Battery Low period of 15 days is counted as soon as the Battery Good period is over, but not necessarily when the low battery fault is logged. Consider the following scenario. Controller Power Down Controller Power Up Battery Good Battery Low A B Battery Low period starts Battery Low fault logged The Battery Low period of 15 days starts at Point A, but the low battery fault is logged only at Point B, once the controller is powered ON. So, the user should make a note that the timestamp of the Low Battery fault may not give the exact start of the 15 days Battery Low period. Note: This battery is not supported on all the PACs CPUs. The table shown below lists the compatible CPU models. Rx3i Rx7i Family CPU type CPU310/CMU310 CPE010 CPE020/CRE020

6 Smart Coin Cell Battery Agency Certifications This product is a Listed Accessory for the PACSystems Rx3i and Rx7i family of PLCs and has been evaluated to the following standards for ordinary and hazardous areas. UL 2054:2004 ANSI/ISA 12.12.01: 2007 (UL File E157515) EN 60079-0:2006 EN 60079-15:2005 In order to maintain agency certifications this product must be mounted in an enclosure with mechanical impact strength equal or greater than 3.5 Joules. ATEX Marking and Information II 3 G Ex na IIC T6 Ta: 0-60C