Operation Manual for OPM-1315 Optical Power Meter

Similar documents
Operation Manual for OLS-1315 Optical Light Source

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

Optical Power Meter With VFL. User Manual

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

RA3301Optical Multimeter

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

AF-OLK5A Series Fiber Optic Test kit

RA3211 PON optical power meter

HCC-CW-201A. CWDM Analyzer. Operation Guide

TOM103. Optical Power Meter OPTICAL POWER METER

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

Ra Series Fiber Optic Test Instruments

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

C2000 POWER METER With Data Storage

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

OLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter

Optical Power Meter MT-7603

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

PM-204A/B. Power Meter. Operation Guide

AQ2170 Optical Power Meter

PM-100 SERIES. Operation Guide. Power Meter V

SmartPocket Optical Power Meter OLP-34/35/38

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source

FiberLink 6650 Series

Training Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

VIAVI SmartClass OLA-55M

Model RP450. Optical Power Meter

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

PM-800 Optical Power Meter INSTRUCTION MANUAL

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

DIGITAL DIRECTIONAL INLINE OPTICAL POWER MONITOR/METER

FiberBasix 50 Handheld Testers

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product

FTE-6000 Hand Held Tuneable Laser Source

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

True RMS AC Voltage/Current Datalogger

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

USER MANUAL FOT-PM Optical Power Meter

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

User Guide. Moisture Meter. Model MO250

AE3100 Series User Manual. Version 1.02

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

Annexure-I: Technical Specification of Handheld Optical Power Meter Purchase Ref: Parameter ITI Specification Vendor-1 Vendor-2 Vendor-3 Remarks

KI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)

Optical CWDM Power Meter

Technical Specification. for. 10 Gbps SFP+ Checker

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

User Manual. Optical DWDM Power Meter ODPM-48

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

Mini OTDR MOT-700 USER MANUAL

OPM-50 Optical Power Meter User s Manual

FX40/45 Series Manual D P RevA00 Page 1 of 25. FX40/45 Series Manual D P RevA00 Page 1 of 25

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

VIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.

LTS-1 LTS-1C LTS-2 LTS-5 LTS-6 LTS-7 LTS-10 LTS-11 LTS-12. Wilcom. Optical Loss Test Kits. Description LTS-2

RS Stock No Instruction Manual RS Input Data Logging Thermometer

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Torque Meter. Instruction Manual

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Light Meter (Foot Candles)

4-Channel Thermometer

Portable Conductivity Meter M1410. User Manual 1.002

User Guide. HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Hawkeye Classic Video Borescope. Hawkeye Classic Video Borescope - Set Up

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

I. PANEL DESCRIPTION... 1

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User's Guide. Datalogging Light Meter with PC Interface. Model

User's Guide. Model Laser Photo Tachometer

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

SoilStik ph Meter PRODUCT MANUAL

HI HI N HI HI

AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE

Optical Time Domain Reflectometer USER'S GUIDE

STRATUS INSTALLATION. 30 Barnet Boulevard New Bedford, MA (508) WOOD SCREWS COVER SENSOR CAULK BRONZE 8" MIN SENSOR HOUSE CABLE CLIP

AQ2180 Optical Power Meter

Sound Level Pen Instruction Manual

Integrating Sound Level Datalogger Model

BBA-Series Precision Balances

Gavita Master Controller EL1

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

V1.0. User Manual Sparkular mini. Liuyang Xiaowen Electronic Technologies Co., Ltd

JDSU Optical Handheld Testers. Family of light sources, power meters, attenuators, loss test sets, return loss meters, and optical talksets

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR

Handheld Video Microscope

Transcription:

Operation Manual for OPM-1315 Optical Power Meter www.tonercable.com

Table of Contents 1. Introduction... 1,2 1.1 Summary... 1 1.2 Product Features... 2 1.3 Technical Parameters... 2 1.4 Main Applications... 2 2. Operation Instructions... 3 2.1 Powering On / Off... 3 2.2 Auto-Off Function... 3 2.3 Backlight Operation... 3 2.4 Control Panel Description... 3, 4 3. Instructions for OPM1315 Power Meter... 4 3.1 LCD Display... 4,5 3.2 Wavelength Selection... 5 3.3 Absolute Power Measurement... 5, 6 3.4 Relative Power Measurement... 6, 7 4. Maintenance... 7 4.1 How to clean probe... 8 4.2 9V Battery Replacement... 8 5. Calibration and Measurement... 8, 9 5.1 Calibration for accurate performance... 8 5.2 Calibration Wavelength... 8 5.3 Calibration Instructions... 9 6. Troubleshooting... 10 7. Warranty Information... 11 7.1 General Information... 11 7.2 Included in Package... 12

1. INTRODUCTION This is the operation manual for the OPM1315 Optical Power Meter. Image 1 below shows the location and function of the OPM1315 Key Field LCD Optical Interface Hanging Hole Sheath Body DC In Support 1.1 SUMMARY The OPM1315 is a newly developed portable optical power meter. It is equipped with a 1.0 mm large area detector so that stability and reliability can be enhanced effectively. This unit is designed to fit the hand comfortably, and can be used for installation, debugging, and maintenance of any fiber network but is particularly suited for a singlemode network. It is light weight, has a backlight display, as well as an automatic shutdown feature. The OPM can be widely used in a variety of fields such as cable construction and maintenance, optical fiber transmission, optical fiber communication, fiber optical sensor, and CATV. It is ideally paired with the OLS1315 Optical Light Source for network or passive testing. 1

1.2 PRODUCT FEATURES The OPM1315 has six optical wavelengths to choose from for testing many different systems. The OPM1315 uses a standard 9V battery which will normally yield approximately 200 hours of continuous operation. An optional AC power supply can be used for continuous operation. The OPM1315 is supplied with a SC optical adapter and there are FC and ST available as options. The OPM1315 has auto-off function and backlight switch which can be set from the front panel. 1.3 TECHNICAL PARAMETERS Model OPM1315 Wavelength (nm) 800 ~ 1700 Probe InGaAs Detection Limit 1.0 mm Power Detecting range -70~+10-50~+26 (dbm) Uncertainty Degree ± 5% Standard Wavelength (nm) 850, 1300, 1310, 1490, 1550, 1625 Display Resolution 0.01 dbm Working Temp ( C) -20~+70 Storage Temp ( C) -30~+80 Automatic Shutdown Time 15 (min) Battery (hrs.) 200 Overall Dimension (mm) 185X105X50 (7X4X1.75 ) Power Supply 9V battery, AC adaptor Weight (g) 350 (13 oz) 1.4 MAIN APPLICATIONS Measurement of the power of an optical transmitter (dbm and W) Testing loss of a optical fiber link Testing insertion loss of optical passive device Installation and maintenance of fiber optic systems 2

2. OPERATION INSTRUCTIONS 2.1 TURNING OPM1315 ON AND OFF Press the button to turn unit on. (NOTE: When the meter is switched on, the auto-off function is automatically activated.) Press the off. button and hold for 2 or 3 seconds to turn the meter 2.2 AUTO-OFF FUNCTION When the meter is turned on, the auto-off function is activated. If the meter is not used for 15 minutes, it will automatically shut off. To disable the auto-off function, simply push the a second time after the meter is turned on. Pushing the again will turn the autooff function back on. 2.3 BACKLIGHT OPERATION The backlight will automatically turn off when the meter is not used for about 1 minute to conserve battery, pressing any button will turn the light back on. 2.4 CONTROL PANEL DESCRIPTION Power Button Used to turn meter on and off. Auto-off function operates through the use of this button. Wavelength Button This button is used to select the wavelength. 850nm, 1300nm, 1310nm, 1490nm, 1150nm, and 1625nm. Press the button repeatedly to step through the wavelengths. 3

Measurement Selection Button This button is used to select either dbm or mw, nw between the absolute and relative measurements of optical power. (mw is milliwatt, or 10 ˉ3, nw is nanowatt or 10 ˉ9 watt) Calibration Button Press this button to save the current power value (zero the test setup). This value can be used as a reference and will be displayed in the upper right hand corner of the LCD screen. Pressing this button quickly will switch the function to a relative power measurement. With the reference power value showing, the relative value will now be displayed between the current measurement and the reference power. The meter is now db. 3. INSTRUCTIONS FOR OPM1315 POWER METER 3.1 LCD DISPLAY Once the power is turned on the following information will display on the LCD screen: (1) When the meter is on battery power, a battery level indicator will be displayed in the lower left hand corner. When the indicator goes down to one bar, it is time to replace the battery. 4

(2) When operating on the AC adapter, a plug symbol will be displayed above the battery indicator. (3) In the lower left hand corner of the LCD screen next to the battery indicator is the auto-off indicator. When the meter is turned on this is automatically activated and will turn the meter off after 15 minutes if the meter is not used. (4) The middle of the screen is where the optical power level is displayed, either in dbm or mw. (5) In upper right hand corner, the reference power value will be displayed when the meter is dbm. This is used when zeroing the power meter with a light source. (6) In the upper left hand corner, the optical wavelength selected will be shown in nm (nanometers). 3.2 WAVELENGTH SELECTION There are a wide range of wavelengths including 850nm, 1300nm, 1310nm, 1490nm, 1550 nm for your convenience. These are available by pressing the λ button. 3.3 ABSOLUTE POWER MEASUREMENT (dbm) (1) Use one fiber optic jumpers to connect the output port of the light source with the detecting port of the fiber power meter as shown in the following figure: (2) Turn on the light source and then select the wavelength to be tested. 5

(3) Turn on the fiber power meter and select the specified wavelength. (4) The LCD display now shows the actual output power of the light source as shown in the following figure (power shown is 09.73 dbm). 3.4 RELATIVE POWER (LOSS) MEASUREMENT nw (nanowatt) The nw mode is mainly used for the measurement of relative power or insertion loss. Under nw mode, the power value measured is reduced by the reference value. The insertion loss or the loss of optical fiber link will be shown on the LCD screen. Note: It is necessary to set up the reference value for each wavelength (zero the meter). (1) Use two fiber optic jumpers and a mating sleeve to connect the output port of the light source, and with the detecting port of the fiber power meter as shown in the following figure: (2) Turn the light source on and select the wavelength to be tested. 6

(3) Turn on the fiber power meter and select the wavelength being tested. (4) When the power meter displays the level received from the light source, press REF button and the power value will be saved as the current reference value (the display is zeroed and the actual level in dbm is displayed in the upper right of the LCD display.) this is the actual loss of the two jumpers and the mating sleeve. See figure below where the meter is zeroed and the REF shows -09.12. (5) Now disconnect the two fiber jumpers from the mating sleeve and connect to the network or device that is to be tested. The reading on the LCD screen shows the insertion loss of the network or device being tested. 4. MAINTENANCE As a highly sensitive electric & optical instrument, this meter must be maintained carefully in order to preserve its high precision and flexibility. Please pay close attention to the following items: Before each use clean the optical fiber connector Keep away from dust Only keep the meter in a dry clean place away from direct sunlight Temperature variations should be avoided to maintain accuracy The meter cannot tolerate any kind of impact or vibration 7

4.1 HOW TO CLEAN PROBE Clean the probe of the optical power meter regularly. (1) Open the dust proof cap. (2) Screw off the adapter. (3) Use 2.5mm cotton swab with some anhydrous alcohol to lightly clean the surface of the probe. WARNING: Do not use anything hard or abrasive when cleaning the surface of the probe. Do not drop since it may crack the probe and cause the meter to not work. ATTENTION: Remember to cover the dust-cap when not using the meter. 4.2 9V BATTERY REPLACEMENT Open the back cover in order to remove and install the battery. Following is some useful information for better operation: (1) Install a new Alkaline 9V battery when the icon is displayed on the LCD screen. (2) Check the condition of the battery if the unit has been out of use for some time. 5. CALIBRATION AND MEASUREMENT 5.1 Accurate performance can only be achieved through the proper care and use of this meter. In order to ensure performance it is recommended that the calibration be checked annually, and if necessary recalibrate the meter. 5.2 To perform a calibration of the optical power meter a light source with a known output level is required. The light source must be on the wavelength the meter will be calibrated to! 8

5.3 To calibrate the light source follow the following instructions: (A) Open the back cover where the battery is located and you will see two toggle switches. To put the meter in calibration mode, turn either one of the toggle switches to the ON position. You are now ready to calibrate the meter. (B) Connect the meter to a known light source and set to the correct wavelength. Compare the reading on the meter to the known power level of the light source. If the readings are different then you can adjust the reading on the power meter either up or down so that it reads exactly the same as the light source. Pressing the REF button increases the display value by 0.05dB. Pressing the dbm/w button reduces the display value by 0.05dB When done, press the On/Off button to save the calibration REF Button dbm/w Button ON/OFF Button Increases the displayed value by 0.05dB Decreases the displayed value by 0.05dB Quickly press this button to save the value calibrated. Press this button twice to turn off the power meter. (C) Open the back cover where the battery is located and turn the toggle switch to the OFF position for normal operation. 9

6. TROUBLESHOOTING PROBLEM Inaccurate measurements Failed to start / no screen display Low LCD Display Some variation of optical power upon powering meter on Low output power of light source POSSIBLE REASON Not matching the wavelength of the light source 9V battery is dead Low battery power No preheating for optical maser Dirty connectivity port of light source CORRECTIVE MEASURE Change the operating wavelength on the meter Change battery Either use AC adaptor or change the battery Turn on the light source and activate the operating wavelength. Calculate measurement after 30 min. of preheating Clean the connectivity port thoroughly 10

7. WARRANTY PERIOD 7.1 GENERAL INFORMATION The meter has a one year free from defects warranty period. This warranty is from the date of delivery and shall be guaranteed for any defects or faults caused by material quality or nonperformance. Performance under normal operating conditions is fully guaranteed. Under this guarantee the company reserves the right to carry out any maintenance it deems necessary to restore the meter to optimal performance. If maintenance fails then the unit will be replaced. One free calibration is included on any warranty item. Note: Any damage that is caused by improper use of any kind will be charged for any maintenance or necessary replacement. The company will not be responsible for any accidental damage caused by the use of this meter. WARNING: If any of the following conditions takes place, the warranty shall be null and void. (1) If the warranty label is removed. (2) Case bolts (not mentioned in the manual) have been removed. (3) Improper use of the meter. (4) If the serial number has been altered or removed. (5) If the meter has been damaged. (6) If the meter has been exposed to moisture. 11

7.2 INCLUDED IN PACKAGE OPM1315 Portable Optical Power Meter... 1 piece Operation Manual... 1 piece 9V Battery... 1 piece Cotton Swab... 1 piece Options AC Power Adapter model OPM-PS FC Optical Adapater model OPM-FC ST Optical Adapater model OPM-ST SC Optical Adapater model OPM-SC 12

969 Horsham Road, Horsham, Pennsylvania 19044 USA 800-523-5947 FAX 215-675 7543 TEL 215 675 2053 email: info@tonercable.com www.tonercable.com