chamber called an Zeta-Meter 4.0 Unit

Similar documents
CH142: Instructions for the Vernier LabPro

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual

831 KF Coulometer. Never before has coulometric Karl Fischer water determination been so economical!

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Accessories for MVA 13

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

- 1 - TITRAMAX OPERATING MANUAL

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

8241 Silica Monitor. Cost-effective automated monitoring of silica in a wide range of applications

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

MICROFLUIDIC EOF KIT 9015

Measurements in Fluid Mechanics

ph 8+ DHS ph- mv - Temperature GLP - USB Data Logger - RS232 printer

Spraybase Technical Specifications Sheet

Introduction: Features:

Introduction to the FTA4000

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

AquaController Apex Probe Module 2

and Multiparameter Meters

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER

Installation instruction for MVA-20: 894 Professional CVS fully automated for CVS determinations. Content

Cole-Parmer Instrument Company

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Cole-Parmer Instrument Company

Particle size range (0.8 microns 1000 microns)

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

D-2 Incorporated. Real-Cond Handheld Fuel Conductivity Product Brochure

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

Handheld Water Quality Meters 100 Series

FiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

HI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter

MultiLine IDS Portable Meters. PORTABLE MULTIPARAMETER MEASUREMENT OF ph, DISSOLVED OXYGEN, CONDUCTIVITY AND TURBIDITY

1. Introduction. 2. Technology

COT 20 Linear Stainer.

HI 9828 Multiparameter Water Quality Meter...

Portable Conductivity Meter M1410. User Manual 1.002

Distributor: Topac Inc 231 CJC Highway Cohasset MA Tel Fax

Dissolved Oxygen Meter Kit DOK. Instruction Manual

C-Rover Transmissometer

The Perfect Fit for Over 40 Years

User Guide. ExStik FL700. Fluoride Meter

Resolution selectable from 0.01 and ph. Range to ph. Accuracy ± ph

ORION Research Inc. Table of Contents

Instruction Manual. Laboratory EC Meter NeoMet Series. EC-400L (EC/TDS/ Salinity/Temp)

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

FTIR-7600 FT-IR Spectrometer Accessories Price List 2011

Professional Waterproof Meters

AquaController Apex Probe Module 2

OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

703 Laboratory Conductivity Meter

815 Robotic USB Sample Processor XL

Polarization Microscope. Omano OM349P Series. User Guide

Control and automatic dosing

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

Using I9131 Sodium Combination ISE on 3200I/M

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

USER MANUAL AD 630 DO & Temperature Waterproof Meter with Galvanic Probe

USER MANUAL AD 630 DO & Temperature Waterproof Meter with Galvanic Probe

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

FiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded

Electrodes ph EC DO /14 dge 2 P/L e

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

870 KF Titrino plus. Installation and tutorial EN

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

User Manual. Trinocular Stereo Microscope

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual

DO Meter Kit. Instruction Manual

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

Operations Manual EcoSense ph100a

BigEye Lens M46 Instruction Manual

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

Accessories for

TIF785 Photo Tachometer

Ideal portable ph. Automatic temperature compensation. Slimline waterproof casing

FOR QUALITY THAT LASTS!

Manual for the MicroSIA Instrument

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Rugged and waterproof, plus high-power telescope with superior Nikon optics

HI 9828 Multiparameter Water Quality Meter...

The Autopol VI Automatic Polarimeter

Installation and operation manual ReciFlow Gas

Accessories for

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

Little Dipper 2 In-Line Fluorometer

FiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded

Radnoti. Radnoti. Radnoti. Precise digitally controlled temperature. Illuminated chamber improves sample viewing

IMP-2MC ELECTRODE IMPEDANCE TESTER MULTICHANNEL

Linkam Scientific Instruments

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

Transcription:

Volts Volts: Scale: Avg. SC: Temp: Average: Std Dev: Count: Full 215.6 us/cm 22.4 C -31.20 3.21 30/30 Easy to Use Detailed LCD Display ZETA-METER 4.0 Volts Zeta-Meter 4.0 Unit Volts: Scale: Full Avg. SC: 215 us/cm Temp: 22.4 C Average: -31.20 Std Dev: 3.21 Count: 30/30 Graphical Analysis Proven Value to comfortably Practical Instrumentation observe More than 40 years colloidal ago, we pioneered the development of a simple, reliable particles instrument to measure inside electrophoretic a mobility and zeta potential. chamber called an electrophoresis Our Zeta-Meter System 4.0 continues cell. this tradition and makes the An determination electric even more field convenient. causes Reliably Simple charged colloids The measurement to is move very direct. with The sample is placed in a viewing chamber Once called an electrophoresis your sample cell. Then isan electric field is activated. This causes the colloids to move with a velocity that is proportional to their zeta potential, and a direction that indicates whether their charge is positive or negative. Once your sample is in the cell, you get your first results in a matter of seconds, and complete results in minutes. Zeta-Meter 4.0 Unit Easy to Use Just fill the cell with your sample, insert the electrodes and connect them to the Zeta-Meter 4.0 unit. It determines the specific conductance of your sample and helps select the appropriate voltage. It also measures sample temperature with an accurate probe. Energize the electrodes and watch the colloids as they move across a grid in your microscope or video display. Track one by simply pressing a button and holding it down while your colloid moves across the grid. When you release the button, your colloid s zeta potential (or electrophoretic mobility) is instantly displayed. Error Free The Zeta-Meter 4.0 is mistake-proof. It recognizes impractical results and tracking times that are too short. Guaranteed Support Our instruments are covered by a 2 year limited warranty. In addition, if your Zeta-Meter ever needs servicing and you just can t do without it don t worry we ll send you one at no charge. Just pay the freight and insurance and it s yours for as long as we have your system here for repair. In fact, if your unit is under warranty we ll ship the other to you absolutely free. If you are outside the USA we ll ship you easy-to-install replacement parts by express mail or courier service. We also offer unlimited technical support via telephone (toll-free in the USA), fax or e-mail. We will do everything possible to help you with your Zeta-Meter. Data Display & Review The Zeta-Meter 4.0 constantly displays a summary of your measurements. You can see how many colloids you have tracked, their average zeta potential (or electrophoretic mobility) and the statistical standard deviation of your values. In addition, temperature and average specific conductance are also displayed. You can review your data in detail at any time by using the keypad to step through each inividual tracking value. You can easily scrub inconsistent data. Hard Copy You can feed your data directly into the serial port of a personal computer. Our free software imports your data into a database that lets you store, search, graph, print and review your data.

Microscope Module Microscope Module Superior Optics We use a high quality stereoscopic microscope. It features 20X wide field eyepieces in combination with a 4.0X paired objective. Overall magnification is 80X. This microscope is very adequate for colloids as small as 1.5 microns in size. If your colloids are smaller than this, then a video display is required. All microscope components including illuminators, a mirrored cell holder and an accurate positioning stage are mounted on a common module. We pre-focus the entire assembly to make your initial setup easy. A basic Zeta-Meter System 4.0 with a stereo microscope is part number Z401. Comfortable Viewing Our viewing technique is called dark field illumination. A sharply focused light beam is reflected diagonally upward by a mirror and passes through the cylindrical tube of the electrophoresis cell. Each colloid in its path reflects light upward into the optics, creating a distinct star-like image on a dark background. Our illuminators use high intensity LEDs. Their long life means that you will probably never need to replace them and re-focus the assembly. Convenient Set-Up Alignment of the cell and focusing of the microscope is remarkably simple. No need to compute and record dial or micrometer settings. Just focus sharply on a special light pattern created by our illumination technique. Direct Video Module LCD Monitor Direct Video Module Easier Viewing Our video displays make it even easier to view and track your colloids. The image is transmitted directly to a camera via optics that are specifically designed for a video display. A monochrome, low light level, video camera captures the image and transmits it to a 17 inch LCD monitor. It is suitable for colloids as small as 0.5 microns in size. All components including camera, optics, illuminators, mirrored cell holder and an accurate positioning stage are mounted on a common module. We pre-focus the entire assembly to make your initial setup easy. A basic Zeta-Meter System 4.0 with Direct Video Imaging is part number Z402. Star-Like Images Our dark field illumination technique creates a distinct star-like image on a dark background for each colloid. A long life, high intensity, LED in each illuminator means that you will probably never need to replace them and re-focus the assembly. No Dials or Micrometers Alignment of the cell and focusing of the video optics is remarkably simple. Just focus sharply on a special light pattern created by our illumination technique. Instant Re-plays You can use a video recorder to create a permanent record of your work. Then, if there is a question about your results, you can use your Zeta-Meter 4.0 unit to obtain another set of data by making a dry run.

G201 Type GT-2 Cell G205 AST Fittings Electrophoresis Cell Rugged Yet Precise Our Type GT-2 electrophoresis cell is rugged, and you can handle it without fear of damage. The cell consists of two Teflon electrode sections and a fused quartz block with an optically polished cell tube. Each cell is individually calibrated and will last a lifetime. It is immune to attack except by very aggressive reagents which can etch glass, such as hydro-flouric acid. AST Fittings Teflon AST Fittings adapt the Type GT- 2 cell for use with the Automatic Sample Transfer. One set is included with the AST (A200). Easy to Use Filling is simple. Just pour in your sample and insert the electrode stoppers. No syringes are necessary. Cleaning is also simple. Just remove the end stoppers, rinse the cell, and clean the cell tube with our cell swab. Low Volume Cell Our standard cell requires at least 20 ml of sample. If your sample volume is limited, then we offer an optional Low Volume Type GT-2 Cell (G201L) which reduces the sample size to 5mL. G202 Molybdenum Anode G203 Platinum Cathode G204 Platinum Anode (Optional) Electrodes Simple by Design Our standard electrodes are a Molybdenum Anode and a Platinum Cathode. You should also consider an optional Platinum Anode for low conductivity samples. Each electrode is mounted in a threaded Teflon stopper and is supplied with a detachable electrode lead. Molybdenum Anode This is our standard anode. Molybdenum combines with gaseous oxygen as it evolves from the anode and prevents false colloid motion due to gas bubble expansion. It can be used with all aqueous samples. Platinum Cathode This is our standard cathode. It is a rugged bullet-shaped electrode made of platinum-iridium to minimize interaction with your sample. Platinum Anode (optional) This is similar to our Platinum Cathode. It is suitable for samples with a specific conductance of less than 0 microsiemens/cm. In this conductivity range, it is easier to use than a molybdenum electrode because it does not have to be cleaned. We recommend this electrode for all work with organic liquids. We also recommend it for potable water treatment laboratories. Platinum Anode for Low Volume Cell (optional) Our standard Platinum Anode (G204) cannot be used with our Low Volume Type GT-2 Cell. We offer a Low Volume Platinum Anode (G204L) to fit this cell.

Automatic Sample Transfer A200 Automatic Sample Transfer Convenient The Automatic Sample Transfer (AST) simplifies sample handling. It consists of a recirculating pump and two electric pinch valves. The pump recirculates your sample from a beaker, through the electrophoresis cell and back. This insures sample uniformity, temperature equilibrium and re-suspension of settled colloids. A flip of a switch isolates your sample. One set of AST fittings (G205) is included. These adapt your cell to the AST unit. Resuspend Particles Large particles or flocs can be difficult to track because they tend to settle out of view. The AST resuspends them and flushes them out during recirculation while it introduces fresh particles for tracking. Balance Sample Temperature The electric field that is applied during tracking can cause highly conductive samples to gradually increase in temperature. Eventually, thermal currents form in the liquid and the particles begin to move erratically. The AST restores temperature equilibrium by recirculating the sample through the cell. We recommend the AST when samples have a specific conductance greater than 2500 microsiemens/cm. Study Concentration Effects The AST is very helpful when variations in reagent concentration or ph need to be studied. Each incremental dose is added to the sample beaker. Then, the AST is used to flush out the cell and fill it with fresh sample at the new concentration level. V Vertical Micrometer T Temperature Control Bath Other Accessories Vertical Micrometer Our optical cell alignment technique works with water and with liquids that have an index of refraction close to water. If the index of refraction of your sample is not similar to water, then the focusing pattern will not appear and our Vertical Micrometer is required. Temperature Control Bath Use this if you want to run samples at elevated or reduced temperatures. Zeta potential determinations are made while the electrophoresis cell is submerged in the bath. The bath is equipped with inlet and outlet ports and plugs. You supply: a pump, temperature control and interconnecting tubing. Operating range is 5 75 C. High Voltage Power Supply High voltage is required when you work with organic liquids that have a low dielectric constant or a high viscosity compared to water. High voltage is necessary to induce reasonable rates of colloid motion. Contact us if you would like an evaluation of whether or not a high voltage supply is required for your application. The power supply is a precision unit. Voltage is set with a 10 turn dial and both voltage and current are monitored by a digital display. Special electrode leads to connect the system to your Type GT-2 cell are included. H200 High Voltage Power Supply

Volts Volts Volts: Scale: Full Avg. SC: 215.6 us/cm Temp: 22.4 C Average: -31.20 Std Dev: 3.21 Count: 30/30 Volts: Scale: Full Avg. SC: 215.6 us/cm Temp: 22.4 C Average: -31.20 Std Dev: 3.21 Count: 30/30 Ordering Guide The Basics Start with part number Z401, or Z402. Each is a complete operational system that is ready for you to use. It consists of a Zeta-Meter 4.0 unit, a microscope or video display, and a Type GT- 2 cell with electrodes. It also includes many other features and items. See our Price List for complete details. ZETA-METER 4.0 ZETA-METER 4.0 Z401 Zeta-Meter System 4.0 with Stereo Microscope & Type GT-2 Cell Z402 Zeta-Meter System 4.0 with Direct Video Imaging & Type GT-2 Cell Options & Accessories Next, select the options and accessories that you need. You can also order extra cells and electrodes. Please contact us if you need any help. G204 / G204L A200 G201 G202 & G203 Platinum Anode / Low Volume Platinum Anode Automatic Sample Transfer Type GT-2 Cell Molybdenum Anode Platinum Cathode T H200 G201L V Temperature High Voltage Low Volume Vertical Micrometer Control Bath Power Supply Type GT-2 Cell Specifications Sample Suitability Our Zeta-Meter System 4.0 can measure samples which fall within the following ranges: Zeta Potential Electrophoretic Mobility Specific Conductance Temperature Concentration Particle Diameter Sample Size Suspending Medium -250 to +250 millivolts +20 to -20 microns/sec per volt/cm 0 to 60,000 microsiemens/cm 5 o C - 75 o C 10 mg/l to 80% solids by weight 1.5 to microns (microscope) 0.5 to 50 microns (video display) 20 ml (standard Cell) 5 ml (low volume cell) water or organic liquids Zeta-Meter, Inc Telephone... 540-886-3503 765 Middlebrook Avenue Toll-Free (USA)... 800-333-0229 PO Box 3008 Fax... 540-886-3728 Staunton VA 24402 USA Web Site... www.zeta-meter.com