CommDTM PROFIBUS DP-V1

Similar documents
CommDTM ET 200M. User Manual. Doc. Version 4.0. English

Trebing + Himstedt DTM Library

TACC HART Over PROFIBUS User Manual

Trebing & Himstedt OPC Server DP. Installation Guide

PROFIBUS Scope. Installation Guide. Trebing & Himstedt Prozessautomation GmbH & Co. KG Doc. Version 1.0. Doc. No.

DTM Library. Extended Field Device Access for Plant Asset Management Applications (FDT/DTM) Installation Manual. Version: EN

Operating Instructions Fieldgate SFG500/SFM500

SOFTING LIBRARY. Use Softing's FG-100-PB with PACTware for. configuring PROFIBUS PA Devices

SOFTING LIBRARY. Use Softing's PROFIusb with PACTware for. configuring PROFIBUS PA Devices

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

COMbricks CommDTM with FieldCare

LB/FB8X09* / LB/FB8X05*

TH LINK PROFIBUS. Release Note. Version

User Manual. MOBILINKdtm. Version: EN Softing Industrial Automation GmbH

NETWORK PRINT MONITOR User Guide

TACC. Release Note. Version 3.00

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

KMnet Viewer. User Guide

ishrt USB ishrt USBeX the Bluepack User Manual

FDM R400 Product Summary, Enhancements & Specifications. John Yingst Product Manager Phoenix, AZ April, 2009

Benefit from the Joint Competence of Trebing & Himsted

Device Type Manager DTM for TF12, TF212

2N Helios IP Manager 2N Helios IP Door Intercom Configuring and Administering Software

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

S900 I/O DTM 6.x. System Version 6.0. Power and productivity for a better world TM

Manual. Profi-S-Link. Document 26/834; Edition EN

Generic HART DTM for FDT 1.2 and FDT compliant frame applications Release 6.1

Generic HART DTM for FDT 1.2 compliant Frame Applications Release 4

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.0.2) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

Technical Information DeviceCare SFE100

Your Global Automation Partner. IO-Link Devices Commissioning. User Manual

SIMATIC. PDM V5.2 The Process Device Manager. Preface, Contents. Product Introduction 1. Starting SIMATIC PDM 2 Configuring Networks and Devices 3

Tool Calling Interface

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.1 SP1) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

Basics of setting up. PROFIBUS-PA networks. Martin Ruck Siemens. Jason Nicholl Phoenix. Kris Hardaker United Utilities

Industrial-Automation System HIMatrix. MODBUS Master/Slave. Manual

Technical Information FieldCare SFE500

User's Guide. 1 Pre-operation Confirmation 2 Login and Logout 3 Displaying Device Information 4 Downloading and Installing Packages 5 Appendix

Authorized Send User s Guide Version 4.0

TH LINK PROFINET. Release Note. Version

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

EPLAN License Manager Basic Configuration Guide Version Status: 07/2016

PROGRAM BASED EVENT CONVERTER SMET-SERVER

Industrial IT. Fieldbus Basic PROFIBUS DTM / PROFIBUS DTM Builder Version 4.1. Configuration

PHARO User Configuration Software UCS USER MANUAL Rev.0-15/07/ pharo.reer.it

Applications & Tools. Brief instructions on the communication connection of the MSS 3RK3 to the S via AS-Interface.

Ethernet Modbus X80 Gateway Device Type Manager

DTM for Hilscher DeviceNet Master Devices

Superview INSTRUCTIONS. Version 2.0x

Manual one2edit Version April 2015

SD Card CopyStation. The Ultimate High-Speed Solution

VITA FDS Firing Data System Operating manual. Date of issue: 04.11

EPLAN License Manager Installation Guide Version Status: 06/2017

ecatcher 4 - New Features

Changing Over the EPLAN Parts Database to SQL Server EPLAN Platform Version 2.7 Status: 05/2017

Aprimo Marketing Studio Configuration Mover Guide

DATA ARCHIVING SOFTWARE V.

Supplier Quality Optimization Program ecert User Manual

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Siemens Automation Products

SINETPLAN Siemens Network Planner

Authorized Send User s Guide for imagerunner Machines Version 4.1

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

Drive System Application

Authorized Send User s Guide Version 3.5

ISTA User instructions for the BMW Online Service System for BMW Service and MINI Service (OSS)

FBP FieldBusPlug. Technical Manual. USB to FBP UTF21-FBP UTF21-FBP DTM V

Application note. WAGO-I/O-SYSTEM 750 DALI Multi-Master Module Configuration of a DALI Lighting System via WAGO- I/O-PRO V2.

Preface 1. Storage System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS X-Tools - User Manual Storage System. English.

Version NaViSet Administrator 2. Quick Start Guide English

DHX Driver Help DHX Driver for A-B and SST Network Adapters

Generic Slave DTM for AS-Interface Slave Devices

Preface Master Data System Contact Information SIPLUS CMS

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Layout and display. STILOG IST, all rights reserved

Online Reporting and Information Management System (ORIMS) Manage Financial Returns User Guide for Banks & Trust Companies

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

MX-FR41U. Data Security Kit Operation Guide. Contents

SIMATIC Automation License Manager Manual 02/2008 A5E

HLMSW v7.3 Installation Notes

SHORT DESCRIOPTION ICP 100 TABLE OF CONTENTS ICP 100. KB_ICP 100_E_V300.doc 0 Gantner Instruments Test & Measurement GmbH. Vers.-Nr.

SIMATIC PDM - The Process Device Manager

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

Commissioning PC Stations - Manual. and Quick Start SIMATIC NET. PC software Commissioning PC Stations - Manual and Quick Start.

Preface 1. X-Tools Client 2. Contact Information 3. User Manual X-Tools Client. English. Release English. Release / 25

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

Importing Example Data EPLAN Platform Version 2.6 Status: 05/2016

DTM for Hilscher CANopen Master Devices

S7-200 PPI Monomaster Remote connection How To

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

TA Instrument Explorer. Getting Started Guide

BNI USB A501. USB IO-Link Master User's Guide. english

Manual Version 5. STIHL Service Communication. STIHL SC

AKENEOPIM User Guide Version 1.3. End-user role USER GUIDE END-USER ROLE. Version 1.3. Copyright AKENEO SAS The Open Source PIM

Ethernet DHX Driver Help Ethernet DHX Driver for Allen-Bradley TCP/IP Networks

Preface 1. Main Management System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS4000 X-Tools - User Manual Main Management System.

Soft Terminal Manual

SOFTWARE LICENSE LIMITED WARRANTY

Transcription:

CommDTM PROFIBUS DP-V1 Doc. Version 4.0 User Manual English

Dear Customer, This»User Manual«describes the functionalities of the CommDTM PROFIBUS DP-V1 in a FDT frame application. If you have any further questions, please contact our Technical Support: Trebing & Himstedt Prozeßautomation GmbH & Co. KG Technical Support Wilhelm-Hennemann-Str. 13 19061 Schwerin Germany Phone: +49 385 39572-500 Fax: +49 385 39572-22 E-mail: support@t-h.de Internet: http://www.t-h.de The information contained in this»user Manual«is the property of Trebing & Himstedt Prozeßautomation GmbH & Co. KG. The»User Manual«and extracts thereof may only be duplicated or forwarded to third parties following explicit written approval by Trebing & Himstedt Prozeßautomation GmbH & Co. KG. We reserve the right to make changes and improvements to this»user Manual«as well as the hardware and software features at any time and without prior notification. All product names used herein are trademarks or otherwise protected by law, even if not specifically indicated. 2005-2010 Trebing & Himstedt Prozeßautomation GmbH & Co. KG Doc. Version 4.0 January 2010

Content CommDTM PROFIBUS DP-V1... 4 FDT Frame Applications... 5 Context Menu... 6 Configuration... 7 Change Device Addresses... 13 DTM Addresses... 15 PROFIBUS Diagnosis... 18 Telegram Logger... 24 Engineering Data... 29 xepi 2 Website... 31 About CommDTM PROFIBUS DP-V1... 32 Help... 33 Licensing... 34 Example Application... 36 Design Projects... 36 General Conditions... 39

CommDTM PROFIBUS DP-V1 CommDTM PROFIBUS DP-V1 The Trebing & Himstedt Prozeßautomation GmbH & Co. KG CommDTM PROFIBUS DP-V1 can be used in all FDT frame applications (such as FieldCare or PACTware). It allows communication between PROFIBUS-PA devices, HART devices connected to the PROFIBUS via Remote I/O (RIO) with HART functionality and their devicedtms. This can be done either centrally through the xepi 2, or locally (on-site operation in the field) through a PROFIBUS communication processor (CP5512, CP5611 PC card or Field PG with integrated CP5611). The PROFIBUS communicates acyclically (DP-V1) and parallel to the master class 1 (MCL1) as a configuration master MCL2. For communication with the field device, the respective devicedtm has to be integrated into the project of the FDT frame application. You can use the CommDTM PROFIBUS DP-V1 concurrently severalfold within one FDT frame application by multiple loading of the CommDTM PROFIBUS DP-V1 into the project window. A respective physical access to the PROFIBUS needs to be available for each loaded CommDTM PROFIBUS DP-V1 for communication (xepi 2 CP5512 CP5611 hardware). The CommDTM PROFIBUS DP-V1 is protected by software key. You need to license the software. For respective notes and tips, please refer to the Installation Guide of the Trebing + Himstedt DTM Library. CommDTM PROFIBUS DP-V1 functionalities can be accessed through the context menu of the used FDT frame application. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 4

FDT Frame Applications CommDTM PROFIBUS DP-V1 The different FDT frame applications vary in functionality and appellation of the various functions. This user manual refers to the»fieldcare«frame application with regard to appellations. Complete functions for the frame application are described in the FieldCare help. Fig. 1: FieldCare CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 5

Context Menu Click CommDTM PROFIBUS DP-V1 in the project window of the FDT frame application with the right mouse key. The context menu opens. Its entries are default entries of the FDT frame application. When you select Additional Functions, the CommDTM PROFIBUS DP-V1 entries are displayed. Functionalities in gray font are not supported or already opened. An online connection may be required to access these functionalities. Fig. 2: Context menu for the CommDTM PROFIBUS DP-V1 CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 6

Note! The tag name depends on the FDT frame application. For example the tag name in FieldCare is CommDTM PROFIBUS DP-V1 and in PACTware T+H PB MCL 2. Configuration In this window, you select the hardware (physical access to the PROFIBUS) for the CommDTM PROFIBUS DP-V1. Access can be realized through the xepi 2 or a PC card (CP5512/CP5611). Here you set specific PROFIBUS parameters (bus parameters) for the selected hardware. This function is only available in offline mode. Fig. 3: Hardware configuration CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 7

Procedure: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Configuration. Select the hardware. You can decide to search automatically or to enter the hardware manually. Automatic: Click the Search button and select in the list box the available hardware. (hardware must be installed or rather xepi 2 must be found in the network). The identified hardware is displayed as follows: CP cards:<card type> Channel: <Channel number> xepi 2: <Host name> (<IP address>) The hardware is identified and displayed by multi-cast request via Ethernet. If your network does not support this functionality (e.g. blocked by firewall or router), no hardware or local hardware only will be displayed. In this case, you can set the hardware manually. Manual: Select the device from the list box. If you select the xepi 2, you can enter the IP address afterwards in the field next to the list box. If you select a CP-card, enter the respective channel in the list box aside. Set the PROFIBUS parameters. Adjust the following settings: Address: Click on the list box. Select the respective PROFIBUS address. Baud rate: Click on the list box. Select the respective baud rate for the PROFIBUS network. Profile: Click on the list box. Select the respective profile. Bus parameters are displayed for the selected profile. In the»dp Standard«,»Universal (DP/FMS)«and»Pepperl+Fuchs«profiles, you can only change the HSA. If you want to modify further bus parameters, select»user defined«from the list box. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 8

Click then into the respective parameter field and carry out your settings. Attention! We strongly recommend application of the standard profiles on all masters in the PROFIBUS network. Manual setting of bus parameters requires extensive PROFIBUS knowledge. If the other masters do not use standard profiles, please use the parameters of these other masters. Click the button Test Bus Parameter to check, whether the set bus parameters are correct. In case of errors the incorrect values are marked with an exclamation mark. The corresponding error message is displayed in the window Saved DTM messages. Click OK. Note! The PROFIBUS address (device address) can only be assigned once in a PROFIBUS network. Bus parameters must be identical for all stations in this network. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 9

Explanations for the CommDTM PROFIBUS DP-V1 Window (Configuration) Hardware Hardware selection for application of xepi 2, CP5512 or CP5611. Address Address in the PROFIBUS network Baud rate Baud rate of the PROFIBUS network Profile HSA Selection of bus parameter profiles In the preset»dp Standard«,»Universal (DP/ FMS)«,»Pepperl+Fuchs«profiles, you can only change the HSA. If you want to modify further bus parameters, select»user defined«from the list box. Then click into the respective description field and adjust your settings. Highest Station Address States the highest valid station address in the PROFIBUS network. Tsl Min Tsdr Slot time This time determines the maximum time the sender waits for a response from the addressed station. Min station delay responder This time determines the minimum delay after which the responding station shall answer at the earliest. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 10

Max Tsdr Ttr Tqui Tset GAP Retry limit Max station delay responder This time determines the maximum delay after which the responding station shall have answered at the latest. Target rotation time This time is the maximum time available for one Token rotation. In this time span, all DP masters receive the Token once. Quiet time for modulator This is the time a station needs for switching from sending to receiving after telegram end. Setup time This is the time that may pass between receiving a data telegram and the respective reaction of the station. GAP factor Specifies after how many bus rotations the master searches for new active stations in order to include them into the bus and send the Token to these stations. The GAP range lies between the own and the subsequent station address (exception: the range of the highest station address up to address 127 does not belong to the GAP range). Maximum number of call retries Determines the maximum number of telegram retries carried out to reach a station. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 11

CommDTM Application with Siemens CP5512 and CP5611 To use the CommDTM with Siemens CP5512/CP5611 hardware, you first need to activate the Trebing + Himstedt driver. This can be done via the entry in the Windows start menu: START > Programs > Trebing + Himstedt > DTM Library > Activate T+H Driver. If you want to use the CP5512/CP5611 with another application and the Siemens driver again, you first need to activate this driver. This can be done via the entry in the Windows start menu: START > Programs > Trebing + Himstedt > DTM Library > Activate Siemens Driver. Note! For hardware modifications on your PC, including driver switching, you need to have the respective administrational rights and authorizations. If you encounter any problems, please contact your administrator. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 12

Change Device Addresses Context Menu With this function, you can display and modify PROFIBUS addresses of the connected devices. This functionality is only available in online mode. Device addresses can only be changed if the respective device supports this function. Fig. 4: Change device addresses Procedure for device address modification: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Establish Connection. The existing online connection is displayed in the FDT frame application (see Help for»fdt Frame Application«). CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 13

Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > Change device addresses. The scan procedure after devices is performed by clicking the Refresh button. Afterwards the devices are listed in the Change device addresses window. Respective device names, DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame application. Mark the respective device. Select a new address from the list box in the bottom part of the window and click Accept. Automatically, an online connection to the device is established, the address is modified, and the device disconnected. In the status bar of the window, information is displayed on whether this function has been completed successfully, or whether the device does not support this functionality. Attention! After device address modification, you need to set the DTM address of the respective CommDTM or devicedtm to the same address. Note! Not all devices support device address setting through the CommDTM PROFIBUS DP-V1. Device addresses for some devices can only be set directly at the device. For respective information, please refer to the manual of the respective device manufacturer. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 14

DTM Addresses Set DTM Address Procedure for setting DTM address: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select the function Add device. Select a device from the device catalog and click OK. The window for setting DTM addresses appears. Set the DTM address and click OK. Change DTM Addresses With this function, you can display and change DTM addresses of subordinate CommDTMs or devicedtms. This function is only available in offline mode. The DTM address shown and set is used to establish connection to the respective device. Please make sure to use an identical address both for the device and for its respective DTM. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 15

Fig. 5: Change DTM addresses Procedure for changing DTM address: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > Change DTM addresses. The scan procedure is performed by clicking the Refresh button. Afterwards the devices are listed in the Change DTM addresses window. Respective device names, DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame application. Mark the respective DTM. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 16

Select a new address for the devicedtm in the Current DTM address list box and then click Accept. In the status bar of the window, information is displayed on whether this function has been completed successfully, or whether the device does not support this functionality. Note! This function is not supported by all DTM. In this case, you can only modify DTM addresses directly through the devicedtm in the project. Every PROFIBUS address must only be assigned once in a PROFIBUS network. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 17

PROFIBUS Diagnosis Context Menu With this function, you can display PROFIBUS Diagnosis for the xepi 2 that is set in configuration. This function is available in online and offline mode of the xepi 2. The refresh of the interface is automatic and occurs each 30 seconds. To make handling easier tooltips are situated on each element to explain the interface. Fig. 6: PROFIBUS Diagnosis CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 18

Note! To display diagnosis information in the CommDTM PROFIBUS DP-V1, you need to start the PROFIBUS diagnosis measurements in the xepi 2 settings (see Installation Guide of the xepi 2). CommDTM PROFIBUS DP-V1 contains the following sections and views: Fig. 7: Sections and views of the CommDTM PROFIBUS DP-V1 To get into deeper sections click on the icon of one station. To get into higher sections click on the button that is arranged above the tabs. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 19

PROFIBUS Overview Context Menu By default you are in the PROFIBUS overview in the master list after opening the PROFIBUS diagnosis. (see»sections and views of the CommDTM PROFIBUS DP-V1«on page 19 - yellow bordered) Master list The master list displays the masters with their addresses, Tags, descriptions, number of slaves, master failures and repeats. Details The details display detailled information of the PROFIBUS network. Diagnosis list The diagnosis list displays the diagnoses with timestamp of the complete PROFIBUS network. The record starts simultaneously with the measurements in the xepi 2. Range your mouse on the diagnosis detail cells to get advices for troubleshooting. Live list The live list displays all stations of the PROFIBUS strand with its status. Station icons indicate the status. Bus statistics The bus statistic displays the masters of the PROFIBUS network with its current status. You receive the address of stations, the Tag and the information of the supported protocol types. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 20

In addition you get the time in which a slave has to reply to a DP- V0 master and the time for one DP cycle of the master. The bandwidth of the master present the data volume in percentage. Furthermore the data rate of the master is the absolute reference data that is exchanged per DP cycle. In the last column you can set or delete the checkmark for a master to visualize or to exclude the master from the protocol proportion and the bandwidth proportion of the selected masters. Note! If the xepi 2 is active as master class 2 in the PROFIBUS information to protocol and bandwidth are unascertainable. Than this fields are greyed. Failure statistics The failure statistic displays the stations in a table with failures and repeats. The graphical interpretation of failures and repeats of all masters and slaves are presented among the table as long as the checkmark is set in the graphic column. If diagnostic repeater, DP/PA Link or SK3 are identified in your PROFIBUS network, than the following tables are visualized: The table for the diagnostic repeater displays an overview of failure and reflexion rates of the segments of the diagnosis repeater. The table for the DP/PA Link displays an overview of PA devices of the DP/PA Link. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 21

The table for the SK3 displays an overview of PA segments of the SK3. Note! If the xepi 2 is active as master class 2 in the PROFIBUS, information to repeats are unascertainable. Than this fields are greyed. Master Overview Slave list The slave list displays the slaves with their addresses, Tags, descriptions, slave IDs, slave failures and repeats. Details The details display detailled information to the master. Diagnosis list The diagnosis list displays the diagnoses with timestamp of the chosen master. The record starts simultaneously with the measurements. Range your mouse on the diagnosis detail cells to get advices for troubleshooting. Slave Overview Module list The module list displays the modules with their slots, Tags, descriptions and known values/configuration. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 22

Details The details display detailled information to the slave. Diagnosis list The diagnosis list displays the diagnoses with timestamp of the chosen slave. The record starts simultaneously with the measurements. Range your mouse on the diagnosis detail cells to get advices for troubleshooting. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 23

Telegram Logger Context Menu Using the xepi 2 you can record the communication of the CommDTM PROFIBUS DP-V1 with this function. User interface Two tables are used for the visualization of the telegrams, a telegram table and a table for details. Fig. 8: Telegram Logger Note! If telegrams exceed the width of the column in the telegram table, you have to select the telegram to display all data in the table for details. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 24

Die telegram table consists of 10 columns that are named as follows: ID ID Time SA DA SSAP DSAP Primitive Protocol Service Data Description Each telegram entry has an ID, started with the ID 0, all other entries are numbered consecutively. Time in seconds between the start of the measurement and the measurement time of the telegram. Source Address Address of the station that provided the telegram. Destination Address Address of the station that received the telegram. Source Service Access Point Service access point of the providing station for explicit identification of the data within a telegram. Destination Service Access Point The destination station decides by means of DSAP which service has to be performed. e.g Response, Request, Repeat Request or Acknowledge Here the protocol type is shown. (FDL, DP-V0, DP- V1) Here the telegram type is shown. (e.g. Slave diagnosis, Idle) Displays the telegram. Select a telegram to visualize the complete data in the table for details. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 25

The detail table displays the details of the selected telegrams. The progress bar is situated under the detail table. The bar is white after opening the telegram logger to signal the remaining buffer space. Starting the record the color changes to purple for the captured telegrams and blue for the loading progress of the telegram table. The recording buffer has a maximum memory capacity of 1000 telegrams. Note! If the connection to xepi 2 is interrupted during the record, the progress bar color changes to red. Afterwards the telegram logger has to be restarted. Record telegrams Procedure for recording telegrams: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > Telegram Logger. The telegram logger opens. Click Start to start the record. Afterwards the start button changes to the Stop button. Click Stop to end the record. Afterwards the button changes back to the Start button. Note! If the connection to xepi 2 is interrupted during the record, the Start-Stop button is inactive. The telegram logger has to be restarted. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 26

Note! The recorded telegrams are available as long as the window telegram logger is open. If you close the window the telegrams are lost. Click the button Export for saving the telegrams. An arrow is diplayed next to the start button. Click the arrow to open a context menu with the entries Log FDT traffic and Log all traffic. Select Log FDT traffic to record only telegrams of the FDT traffic. This function is performed by default. Select Log all traffic to record all telegrams of the types DP-V0, DP-V1 and FDL. During and after telegram recording you can perform the following functions: Sort Filter Scroll Display details to telegrams Export (see»export telegrams«on page 28) Filter telegrams You can filter the telegrams with the help of the view filter. Procedure for filtering telegrams: Click the filter icon in the heading of the particular column to set filter. Use the scroll bar to get to further selection criteria if more than 7 elements are available. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 27

Select one or several filter elements. The filter icon becomes blue for set filter. The entry delete all delete all set filters of the particular column. The filter icon is inactive again. Note! The columns SA and DA, as well as SSAP and DSAP, use in each case a common filter to display alle telegrams of one station. The selection of one value in the filter of one column is taken over to the value for the second column too. Sort telegrams: Click the symbol in the heading of the column ID for sorting telegrams upward and downward. Export telegrams Procedure for exporting telegrams: To record telegrams repeat the steps under»record telegrams«on page 26. Click the Export button afterwards to transfer the loaded telegrams. Select the directory where you want to save the file and a file format (csv or xml). Enter a file name and press the button Save file. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 28

Engineering Data Context Menu Using the xepi 2 you can transmit tags and descriptions of the FDT project to xepi 2 with this function. Fig. 9: Engineering Data Procedure for exporting engineering data: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > Engineering Data. An additional window opens that enables the export of the engineering data. Enter the administrator password for the xepi 2 (default: serial number of the xepi 2. You find further information in the installation guide of the xepi 2.). CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 29

Afterwards click the button Export to transmit the tags and descriptions of the FDT project in the xepi 2. Note! If there are already existing tags and descriptions on the xepi 2, you are asked to replace the data. Click No to cancel the process. If the tags and descriptions exceed the limits, you are asked to cut at the maximum. Click No to cancel the process. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 30

xepi 2 Website Context Menu With this function, you can open the xepi 2 website for the xepi 2 that is set in configuration. Fig. 10: xepi 2 Website Procedure for opening the xepi 2 website: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > xepi 2 Website. The Internet Explorer opens to display the xepi 2 website. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 31

About CommDTM PROFIBUS DP-V1 Context Menu This function displays information on the installed CommDTM PROFIBUS DP-V1. Fig. 11: About CommDTM PROFIBUS DP-V1 Procedure for opening the window About CommDTM PROFIBUS DP-V1: Click CommDTM PROFIBUS DP-V1 in the project window with the right mouse key and select Additional Functions > About CommDTM PROFIBUS DP-V1. The information about the CommDTM PROFIBUS DP-V1 opens. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 32

Help Context Menu This function starts the»user Manual«in PDF format. Adobe Acrobat Reader is required. Installation of the Trebing + Himstedt DTM Library saves the user manual locally on your system. Fig. 12: User Manual CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 33

Licensing Licensing The CommDTM PROFIBUS DP-V1 is protected by software key. When using the xepi 2 hardware, the CommDTM PROFIBUS DP-V1 is already licensed. When using the CP5512 or CP5611 hardware, you need to license the CommDTM for unlimited use. Without licensing, you can use the CommDTM PROFIBUS DP- V1 as a demo version with unlimited functionality for 30 days from date of installation. After expiry of the 30-day demo version, online connections can no longer be established. At the time of expiration existing online connections will be terminated. Note! The license is generated for the current system. License transfer to other systems is not possible. You can find the current license status in the window About CommDTM PROFIBUS DP-V1 (context menu: >Additional Functions > About CommDTM PROFIBUS DP-V1). CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 34

Types of Licenses Licensing In the following table you find an overview of the types of licenses. Type of license Demo version (... days remaining without functional limitations) Trebing + Himstedt DTM Library Full License Trebing + Himstedt DTM Library Single License No license (demo version expired) Explanation DTM is not licensed. License valid for all DTMs from the Trebing + Himstedt DTM Library. License valid for one DTM from the Trebing + Himstedt DTM Library. No online connection can be established. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 35

Example Application Example Application Design Projects Requirements The following software has to be installed: FDT frame application Trebing + Himstedt DTM Library The following hardware has to be installed: xepi 2 FDT frame application Start the FDT frame application. Open and update the device catalog. Create a new project. Add CommDTM PROFIBUS DP-V1 Click Host PC in the project window with the right mouse key and select the function Add device. Select CommDTM PROFIBUS DP-V1 from the device catalog and click OK. Configure the CommDTM PROFIBUS DP-V1. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 36

Example Application Configuration of the CommDTM PROFIBUS DP-V1 Open the CommDTM PROFIBUS DP-V1 context menu and select Configuration. Click the Search button and select a xepi 2 of the list. Configurate according to your PROFIBUS network. Fig. 13: Added CommDTM PROFIBUS DP-V1 CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 37

General Conditions General Conditions Right to make additions or alterations Trebing & Himstedt Prozeßautomation GmbH & Co. KG reserves the right to continue development of this user manual and the properties of the hardware and software at any time, also without releasing information about this or about alterations prior to doing so. Exclusion from liability Trebing & Himstedt Prozeßautomation GmbH & Co. KG assumes no warranty for proper function of the hardware and software in all conceivable situations. Currently available technical means do not enable the development of software which is completely free of errors in all conceivable applications. Trebing & Himstedt Prozeßautomation GmbH & Co. KG does not accept any liability for damages, both direct and indirect, arising from the use of the hardware and software and the information contained in this user manual. Duty to monitor products As part of our duty to monitor products, we strive to warn about dangers we have identified which can result from the interaction of hardware and software and product use with third-party products. Monitoring is only possible if we receive sufficient information from our customers on the planned application(s) and the existing hardware and software components. As a result of the complex interactions, it is no longer possible for us to accurately identify all dangers and to check the effect on the overall system and in particular on our hardware and software, if the conditions of application have changed and/or hardware or software has been exchanged. This user manual does not describe all technical characteristics of the hardware and software and their variants. For more information please contact Trebing & Himstedt Prozeßautomation GmbH & Co. KG. Warranty Our products are subject to warranty in accordance with our general business and delivery terms. CommDTM PROFIBUS DP-V1 Trebing & Himstedt Prozeßautomation GmbH & Co. KG 39