IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.

Similar documents
Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

OPERATION MANUAL MODEL TT-LP

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

+GF+ SIGNET ph/orp Transmitter Instructions

Signet ph/orp Transmitter * *

LE ELECTRONICS Pvt. Ltd.

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

SIGNET ph/orp Transmitter

Contents. 1. Installation

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

T80 Universal Transmitter S80 Intelligent Sensors

TOXALERT MODEL AIR 2000

Accsense Wireless System. Temperature Monitor

Optical distance sensors. Dimensioned drawing

PRELIMINARY MANUAL. DC8-50-V3 Current measurement system

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

Cole-Parmer Instrument Company

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Owner s Hardware Service Manual Frank Control Computer System

MPU User Guide Updated 3/11/15. Overview

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

9120 Redundant Probe System (RPSC)

Environdata FA ma Converter Guide

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

SMARTSCAN INFORMATION

OEM-ORP ORP. Reads mV mV. Range. 1 reading every 420ms. Response time. Any type & brand. Supported probes. Single point.

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

Surface Resistivity Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

8 Channel USB to RS485/422 Converter USB-402 User s Manual Ver. 1.0 HuMANDATA LTD.

Operation and Maintenance Manual

DEVAR Inc. Model d-rtti User Manual

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

VersaMax IP Input Module

UMR2. User Manual. Hardware RevC Firmware V1.0. Updated Additional documentation and support available at:

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

INSTRUCTION MANUAL ORP-METER MODEL COR-01

Please take serious note of the following warnings:

SINGLE-CHANNEL PROCESS INDICATOR series 8001

EZO TM class embedded ph circuit

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

MRUC-20 Modul-R CAN Bus Network

Trend-1 Vibration Data Logger. User Manual

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Torque Control Verifier

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Analog Interface Unit Operation Manual

Digital Keypad Introduction

Line Coupler, MDRC LK/S 2.1, GH Q R0001

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Instruction Manual. Instrument Amplifier HE 017

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION.

RASPBERRY PI MEGA-IO EXPANSION CARD USER'S GUIDE VERSION 2.3

I/O EXPANSION MODULES

LD-RTD / LD-TC Temperature Controller

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

OPERATION MANUAL. ph 500 (Cat. No ) MICROCOMPUTER BASED ph / Temperature TRANSMITTER & CONTROLLER

MXD70 SERIES. Multi-parameter Monitor. ph / Redox Setup and Operating Guide

Panel Meter Model PM6-RT Temperature Display Operation and Instruction Manual

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

Adapter Kit - Remote QSI Electronics Installation Instructions

DIN-Rail Mounted Ultrasonic Flow Meter

Microprocessor ph/orp Controller

4 Channel Contact Closure DIN Fiber Link System

MiR Bluetooth Box. Technical Documentation

8 Channel Contact Closure DIN Fiber Link System

LANCNC FTP Data Server for CNC Controls Machine Mount instructions

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Ellab Temperature Indicator

4Trio Motion Technology3

SK TU4-IOE-M12-C Part Number

ProScale LCD Readout Quick Start Guide

User Manual. cmt-svr Startup Guide

Installation Instructions Temperature transmitter TAA /00 06/2011

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Digital Proportional Valve Amplifier

LAUREL ELECTRONICS, INC.

Signet Pressure Transmitter

Trident and Trident X2 Digital Process and Temperature Panel Meter

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Specification for temperature sensor calibration setup

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

LVX Control Unit. Features:

User Manual. PCKeypad Wireless Keypad

Transcription:

V 3.0 Revised 12/13/17 ph IXIAN Transmitter Reads ph Range.001 14.000 Accuracy Calibration Supported probes Temp probe +/ 0.002 1, 2, 3 point remotely through PLC or directly on board Any type & brand PT-100 or PT-1000 Auto Temp compensation Mount Output Operating voltage Electrically Isolated Yes 35mm Din rail 4 20mA 14VDC 36VDC Yes Written by Jordan Press Designed by Noah Press This is an evolving document, check back for updates.

Table of contents Transmitter dimensions Wiring diagram Operating principle Mounting 3 4 5 6 Power connection ph connection Temperature connection 4 20mA connection 7 8 9 10 4 20mA ph transmission Reading 4 20mA output with a multimeter PLC calibration node Fault detect line Calibration theory On-board calibration PLC calibration 4 20mA calibration 4 20mA High 4 20mA Low Temperature compensation Factory reset 11 12 13 14 15 16 17 18 19 20 21 22 2 Copyright Atlas Scientific LLC

Transmitter dimensions 128mm (5 ) 8.5mm (0.3 ) 18.97mm (0.7 ) 35mm (1.37 ) 66.5mm (2.6 ) 27.6mm (1.08 ) 3 Copyright Atlas Scientific LLC

Wiring diagram ph Temperature Atlas Scientific Industrial ph Probe 4 Copyright Atlas Scientific LLC

Operating principle A ph (potential of Hydrogen) probe measures the hydrogen ion activity in a liquid. At the tip of a ph probe is a glass membrane. This glass membrane permits hydrogen ions from the liquid being measured to defuse into the outer layer of the glass, while larger ions remain in the solution. The difference in the concentration of hydrogen ions (outside the probe vs. inside the probe) creates a VERY small current. This current is proportional to the concentration of hydrogen ions in the liquid being measured. Acid: ph < 7 Neutral: ph = 7 Base: ph > 7 Silver wire Junction Silver chloride KCL reference solution Reference wire 5 Copyright Atlas Scientific LLC

Mounting The IXIAN ph Transmitter is specifically designed to be mounted to a 35mm din rail. To detach the transmitter from the din rail, pull down on the din rail release notch. 35mm din rail Din rail release notch. 6 Copyright Atlas Scientific LLC

Power connection Any DC voltage from 14V 36V can be used to power the IXIAN ph Transmitter. The power connector is keyed differently and is larger than the other connectors. Power consumption table VDC 14 24 36 ma 56 34 24 7 Copyright Atlas Scientific LLC

ph connection Any off the shelf two wire ph probe can be used with the IXIAN ph Transmitter. Connecting the ph probe in reverse order will not damage the probe however, the readings will be incorrect. 8 Copyright Atlas Scientific LLC

Temperature connection A PT-100 or PT-1000 temperature probe can be connected to the IXIAN ph Transmitter. Either method of wiring will produce the same result. There is no polarity. or 9 Copyright Atlas Scientific LLC

4 20mA connection Connecting the 4 20mA data output to your PLC, allows the IXIAN ph Transmitter to communicate with your PLC. Connecting the 4 20mA data output to your PLC is purely optional. Leaving it disconnected will have no effect on the IXIAN ph Transmitter s operation. 10 Copyright Atlas Scientific LLC

4 20mA ph transmission The ph value that is visible on the seven segment LED screen is also, simultaneously transmitted through the 4 20mA data output. 7.000 Connecting the 4 20mA data output to your PLC is purely optional. Leaving it disconnected will have no effect on the IXIAN ph Transmitter s operation. ph to 4 20mA equation PLC ADC Resolution ph 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 ma ph ma 10 BIT = 0.015 ph units 4.00 8.00 13.14 16 BIT = 0.003 ph units 5.14 9.00 14.28 6.28 10.00 15.42 7.42 11.00 16.57 8.57 12.00 17.71 9.71 13.00 18.85 10.85 14.00 20.00 12.00 11 Copyright Atlas Scientific LLC

Reading 4 20mA output with a multimeter To debug the IXIAN ph Transmitter output, first connect it to a multimeter as shown. (make sure the multimeter is set to ma ). Once properly connected, set the IXIAN ph Transmitter to calibrate to either 4.00, 7.00, or 10.00. Compare the reading on the mulitmeter to the chart below. 12.00 ma ma ph 4.00 7.00 10.00 ma 8.57 12.00 15.42 12 Copyright Atlas Scientific LLC

PLC calibration node Using the three input connections marked 4, 7, 10 it s possible to use a PLC to fully calibrate the IXIAN ph Transmitter. This is particularly beneficial when using a PLC touch screen. Sending an output signal from the PLC to the ph Transmitters 4, 7, or 10 input connection will calibrate the device. The voltage used to trigger a calibration event should be the same voltage used to power the IXIAN ph Transmitter. Connecting to the PLC calibration node is purely optional. Leaving it disconnected will have no effect on the IXIAN ph Transmitter s operation. 13 Copyright Atlas Scientific LLC

Fault detect line The connection marked F is the fault detect line. During normal operation the fault detect line will output a voltage equal to the voltage used to power the device. If the IXIAN ph Transmitter detects a problem the fault line will drop to 0 volts. Normal operation (24V typical) Fault 0 Volts Example The IXIAN ph Transmitter is powered with 24V the F line will output 24V during normal operation. Events that will trigger the fault line to go to 0 volts ph probe reporting a ph less than 0 or greater than 14. disconnected 4 20mA output. calibration in process. loss of power. Connecting to the fault detect line is purely optional. Leaving it disconnected will have no effect on the IXIAN ph Transmitter s operation. 14 Copyright Atlas Scientific LLC

Calibration theory The Atlas Scientific IXIAN ph Transmitter has a flexible calibration protocol, allowing for single point, two point, or three point calibration. The calibration values are 4.00, 7.00, and 10.00. The first calibration point must be ph 7.00 Calibrating to ph 7.00 will reset the stored calibration. If two, or three point calibration has been done in the past, it must now be redone. 14 4.00 7.00 10.00 There is no correct order when calibrating to 4.00 and/or 10.00. Recalibrating these two points will not have any effect on the other stored calibration points. Calibrating the IXIAN ph Transmitter to 4.00 and/or 10.00 can be done at any time. No calibration Single point calibration 7.00 Two point calibration Three point calibration 14 4.00 7.00 4.00 7.00 10.00 Two point calibration will provide high accuracy between 7.00 and the second point calibrated against, such as a 4.00. Three point calibration will provide high accuracy over the full ph range. Three point calibration at 4.00, 7.00 and 10.00 should be considered the standard. 15 Copyright Atlas Scientific LLC

On-board calibration To begin the on-board calibration process, press and hold the middle orange button for 1.5 seconds to calibrate to a ph of 7.00. 1.5 seconds The first calibration point must be ph 7.00 Calibrating to ph 7.00 will reset the stored calibration. If two, or three point calibration has been done in the past, it must now be redone. The display will flash: CAL7.0, after a few seconds the display will then flash: done If two point or three point calibration is required, repeat this process to calibrate for ph 4.00 (left red button) and ph 10.00 (right blue button). 16 Copyright Atlas Scientific LLC

PLC calibration Using the three input connections marked 4, 7, 10 it s possible to use a PLC to fully calibrate the IXIAN ph Transmitter. Setting the PLC s output to 200ms or more will trigger a calibration event. This is particularly beneficial when using a PLC touch screen. Set calibration 4.00 7.00 10.00 The voltage used to trigger a calibration event should be the same voltage used to power the IXIAN ph Transmitter. CAL 7 button press T2 CAL 7 Transmitter ( OUT ) Timer 2 200ms T2 A calibration event will only trigger if the corresponding input pin has been held high for 200ms. Holding the line for more then 200ms will have no effect. The first calibration point must be ph 7.00 Calibrating to ph 7.00 will reset the stored calibration. If two, or three point calibration has been done in the past, it must now be redone. 17 Copyright Atlas Scientific LLC

4 20mA calibration To ensure that the PLC is receiving the most accurate 4 20mA signal, the current output from the IXIAN ph Transmitter can be adjusted. The 4mA signal and the 20mA signal can both be adjusted independently. To enter the 4 20mA calibration mode press and hold the red and blue buttons simultaneously for 1.5 seconds. 1.5 seconds 18 Copyright Atlas Scientific LLC

4 20mA High The display will flash: 4-20H (the H stands for high) The IXIAN ph Transmitter will now output exactly 20mA, and your PLC should show a ph of 14.00. Use the orange (up) and blue (down) buttons to adjust the 20mA output so the ph moves to 13.99, then move it back up, so it is just hits ph 14. When you have finished making adjustments, press the red (save) button to confirm. The 20mA offset will be permanently stored in memory. 13.999 14.000 Save 19 Copyright Atlas Scientific LLC

4 20mA Low The display will flash: 4-20L (the L stands for low) The IXIAN ph Transmitter will now output exactly 4mA, and your PLC should show a ph of 0.00 Use the orange (up) and blue (down) buttons to adjust the 4mA output so the ph moves to -0.1, then move it back up, so it is just hits ph 0.00 When you have finished making adjustments, press the red (save) button to confirm. The 4mA offset will be permanently stored in memory. -0.100 0.000 Save 20 Copyright Atlas Scientific LLC

Temperature compensation To view the temperature from the attached PT-100, or PT-1000 temperature probe, press the red and orange buttons simultaneously. The IXIAN ph Transmitter will continue to display the temperature for 10 seconds, or until the red and orange buttons are pressed again. If a temperature probe is not connected, The IXIAN ph Transmitter will use 25 C as the default temperature. Temperature data cannot be output to PLC. 21 Copyright Atlas Scientific LLC

Factory reset The IXIAN ph Transmitter can be reset to its default settings. To issue a factory reset, press and hold the orange and blue buttons for three seconds. The display will flash: reset Cancel 3 seconds Press and hold the orange and blue buttons again to confirm the factory reset. To cancel a factory reset, press the red button. 22 Copyright Atlas Scientific LLC