Appendix 3 Using NS-AL002 Converters

Similar documents
Appendix G. CJ1W-CIF11 RS-422A Converter

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

OMRON Corporation PLC SYSMAC CJ1M Series Connection

OMRON Corporation PLC SYSMAC C Series Connection

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

OMRON Corporation PLC SYSMAC C Series Connection

Cat. No. V068-E1-01 NT21. Programmable Terminal. Setup Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Package Contents. GP Options (Made by Digital)

PC CONNECTION Programmable Terminal OPERATION MANUAL

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

PC CONNECTION Programmable Terminal Operation Manual

WARNING. To Prevent From Damage:

NJ-Series Power Supply Unit NJ-PA/PD

Programmable Terminals

WARNING. To Prevent From Damage:

SYSMAC CQM1H Series CQM1H-SCB41 Serial Communications Board OPERATION MANUAL

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models

Safety Relay Unit (I/O Unit Type)

Station 2. Inverter. PU connector (Note1)

About the Manual. ST-3400 Series Installation Guide. Package Contents

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

1.5 axis motion controller

WARNINGS. *1 This mark is applicable only in Taiwan.

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

Safety Monitoring Relays

About the Manual. ST-3300 Series Installation Guide. Package Contents

Device/PLC Connection Manuals

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Power Mate Series Driver

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

Digital I/O Units Compatible with MULTIPLE I/O TERMINAL

Wiring Systems I/O Blocks, I/O Terminals, and I/O Block Bases

Device/PLC Connection Manuals

SIMATIC S5 CPU Direct Driver

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL. Keyence Corporation PLC

DANGERS When Designing your GLC System: WARNINGS Wiring Warnings:

Link Master Adapter. Ordering Information. Connect High-Density I/O PLC Modules to 16-Point B7A Modules

Cat. No. W13E-EN-01. SmartSlice GRT1-Series. GRT1-PNT PROFINET IO Communication Unit OPERATION MANUAL

Power and Expansion Selection

About the Manual. AGP3300-U1-D24 Installation Guide. Package Contents

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

EX-RC1 Remote I/O Adapter

Trajexia motion controller

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

Trajexia motion controller

SYSMAC Remote Transistor Module

Connection Guide (RS-232C)

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Connecting to the Handy Type GP

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Device/PLC Connection Manuals

OMRON SYSMAC - System C200H Alpha CPUs

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

NX integrated safety System configuration. Integrated safety into machine automation

Modbus-RTU Master (Host computers) Serial Communications Units. RS-232C/RS-422A Adapter NT-AL001 Protocol Macro. No-protocol

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

GP3000H Series Installation Guide. Package Contents. About the Manual. (8) Emergency Switch Guard (1) Attachment Screws (3) *1

Essential Safety Precautions WARNINGS

T1K MODBUS Base Controller Specifications

Transistor I/O Link Modules

Device/PLC Connection Manuals

Connection Guide (RS-232C) OMRON Corporation

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

EtherCAT Remote I/O Terminal GX series

Device/PLC Connection Manuals

Programmable Relay ZEN V2 Units

User's Manual. FP7 Digital Input/Output Unit PROGRAMMABLE CONTROLLER

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

RS-232C/485 Isolation Unit Installation Guide. Essential Safety Precautions WARNINGS

FX-485PC-IF RS485 Interface Unit Hardware Manual

Trajexia Motion Controller

V680 Series. User's Manual. Heat-resistive RFID System. ID Controller V680-CA1D V680-CA2D. Read/Write Antenna V680-H01. ID Tag V680-D1KP58HT

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

SmartSlice. System Configuration

Industrial Control Relays Relays and terminal module RS type

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

EX-RC1 Remote I/O Adapter

RS232C/RS485 Data can be easily monitored by LAN

Analog Input/Output Modules

UL/c-UL(CSA) Approval

I/O delay. (0.32 in ±0.06 in)

PLC Communication Converter COM-JE. [For RB Series] Instruction Manual IMR01Y41-E3 RKC INSTRUMENT INC.

EX-RC1 Remote I/O Adapter

SIMATIC S5 CPU Direct Driver

Tecnología en Electrónica y Control SRL Ficha Técnica

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.

User's Manual. FP7 Digital Input/Output Unit PROGRAMMABLE CONTROLLER

Communication Converter COM-E. Instruction Manual IMS01C01-E8 RKC INSTRUMENT INC.

MED102A. Industrial Serial to Single-mode Fiber Converter

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

SRT2-ROC08, SRT2-ROC16

Transcription:

Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix 9 Standard Models can be used. A summary of the external dimensions, mounting and removal methods, and specifications is provided here. Refer to this information when designing the control panel. Refer to the Instruction Sheet included with the for details. Note The is an uninsulated RS-232C/RS-422A Converter. Therefore, if differences in ground potential or effects from noise are concerns, it is recommended that an insulated NT-AL001 RS-232C/RS-422A Converter be used instead. For details, refer to Appendix 4 Using NT-AL001 Converters. A-3-1 Dimensions Mounting screws (2) 49 42 45 12 28.5 A-17

A-3-2 Mounting and Removing Connect the directly to port A or port B of the. Two Adapters cannot be connected to ports A and B simultaneously. Mount the Adapter by tightening and securing the mounting screws on both of the D-Sub connectors. The correct tightening torque is 0.3 N m. The correct tightening torque for the terminal block is 0.5 N m. To remove the Adapter, loosen the screws and pull out the Adapter. Note Always turn OFF the power to the before removing the Adapter. Do not touch the surface or the mounted parts of the Board with bare hands. Always discharge any static electricity from your body before handling the Board. Mount to the after securely connecting the cable to the terminal block. Be sure to tighten the mounting screws on both of the D-Sub connectors. If the screws are loose, the terminals of the and will not be connected. A-3-3 Specifications The following table shows the general specifications and communications specifications of the Adapter. General Specifications Item Specifications Dimensions 45 49 28.5 mm (W H D) Weight 50 g max. Ambient operating temperature 0 to 50 C Storage temperature 20 to 60 C Ambient operating humidity 35% to 85% (without condensation) Rated power supply 5 V ±10% (through pin 6 of the RS-232C connector) Power consumption 150 mw max. Operating environment No corrosive gases. Vibration resistance Conforms to specifications. Shock resistance Conforms to specifications. Reference NS-series RS-485 (two-wire) communications are used to connect to an OMRON Temperature Controller. The cannot be used with the NT-series s or PLCs. Communications Specifications RS-422A Interface Item Specifications Baud rate 115.2 kbps max. Transmission distance 500 m total length (See note 1.) Terminal block format 8-terminal terminal block, M3.0 Insulation No insulation (See note 2.) Note 1: This specification is for a configuration in which all the Adapters connected on the same transmission path are NT-AL002 Link Adapters. If a CJ1W-CIF11 Conversion Adapter is used, the total length is 50 m. Note 2: The RS-422A and RS-232C are not insulated. A-18

A-3-4 DIP Switch Settings The Adapter has four DIP switch pins for setting the RS-422A communications conditions. Set the DIP switch pins before connecting the cables to the Adapter. DIP switch ON OFF The factory setting for the DIP switch is all pins set to OFF. Pin Function ON OFF Pin 1 Transmission mode RS/CS control Normal transmission Pins 2 and 3 Two-wire/four-wire method selection Two-wire method Four-wire method Pin 4 Terminating resistance Yes None For 1:1 NT Link, set the RS-422A transmission mode to normal transmission (pin 1 OFF). For 1:N NT Links (normal, high speed), set the RS-422A transmission mode to RS/CS control (pin 1 ON). Note Use the following DIP switch settings when connecting a CJ1W-CIF11 Conversion Adapter to the. Pin Function Setting Pin 1 Terminating resistance selection ON: Terminating resistance enabled OFF: Terminating resistance disabled Pin 2 Two-wire/four-wire method selection OFF (four-wire) Pin 3 Two-wire/four-wire method selection OFF (four-wire) Pin 4 Not used. OFF Pin 5 Selection of RS control for RD OFF (no RS control) Pin 6 Selection of RS control for SD ON (RS control) When a CJ1W-CIF11 Conversion Adapter is used, the total transmission length is 50 m. If NT-001/NT-002 Link Adapters are used together with CJ1W-CIF11 Conversion Adapters on the same transmission path, the total transmission length is also 50 m. For details, refer to the Appendix G in the SYSMAC CJ Series Operation Manual (W393). Make sure that both of the mounting screws on the D-Sub connector are tightened to a torque of 0.3 N m. A-19

A-3-5 Pin Arrangement The Adapter has a connector for RS-232C interface connection and a terminal block for RS-422A/485 interface connection. The pin arrangements for the RS-232C connector and RS-422A/485 terminal block are as follows: RS-232C Connector Terminal block pin number RS-422A Terminal Block Signal name Signal direction Adapter 1 NC 2 RD 3 SD 4 CS (RS signal short-circuited internally) 5 RS 6 5 V (30 ma max.) 7 or 8 NC (Pins 7 and 8 are short-circuited.) 9 SG Connector hood Connects to functional ground terminal of. Terminal block Signal direction Signal name pin number Adapter Host 1 Connects to functional ground terminal of. 2 RDB (+) 3 SDB (+) 4 RSB (+) 5 NC --- 6 RDA ( ) 7 SDA ( ) 8 RSA ( ) A-20

Crimp Terminals Use M3 crimp terminals. Forked type Round type 6.2 mm max. 6.2 mm max. Applicable Crimp Terminal Examples Forked type Manufacturer Model Recommended cable size J.S.T. Mfg. Co., Ltd. V1.25-N3A AWG22 to 16 (0.25 to 1.65 mm 2 ) Molex VSY1.25-3.5L AWG22 to 16 (0.3 to 1.65 mm 2 ) Round type Manufacturer Model Recommended cable size J.S.T. Mfg. Co., Ltd. V1.25-MS3 AWG22 to 16 (0.25 to 1.65 mm 2 ) Molex RAV1.25-3 AWG22 to 16 (0.3 to 1.65 mm 2 ) Recommended Cable Manufacturer Tachii Electric Wire Co., Ltd. HIRAKAWA HEWTECH CORP. Model TKV VBS3P-03 CO-HC-ESV-3P 7/0.2 A-3-6 Handling the Shield on RS-422A/485 Cables Perform the following procedures to connect, process the shield, and connect to ground for communications systems using the. Incorrect connection may result in communications errors with the host. Connecting the D-Sub Connector Always securely tighten the screws on both sides of the D-Sub connector. Otherwise, the functional ground terminal (: ) of the will not be properly connected to the functional ground of the. Connecting the Ground Wire The has a functional ground terminal (: ). 1. Ground according to Figure (a) for normal grounding. Connect the ground terminal (GR) of the devices to the functional ground (: ). Make sure that each signal line is grounded at only one point and ground to 100 Ω max. Short the LG terminal of the PLC to the ground terminal (GR). Use a wire gauge of at least 2 mm 2 for the ground wire. Refer to the manual for individual Communications Units for details on proper wiring procedures. 2. Do not ground the functional ground (: ) of the if it is mounted to the same panel as devices that generate noise, such as motors or inverters, as shown in Figure (b). A-21

Preparing the Shield of RS-422A/485 Connectors Always prepare RS-422A/485 cable shields properly. Otherwise, communications errors may occur with the host. Ground only one end of the shield when connecting the ground terminal (GR) of the devices to the functional ground (: ), and grounding each signal line at only one point and to 100 Ω max, as shown in Figure (a). Ground both ends of the shield when not grounding the functional ground (: ) of the, as shown in Figure (b). When using the CJ1W-CIF11 or when using the NT-AL001/ together with the CJ1W-CIF11, always performs connections, shield processing, and grounding as shown in Figure (b). A-22

Example of Recommended Wiring Figure (a) CPU Rack CPU Unit or Power Communications Unit supply Unit LG GR Figure (b) CPU Rack CPU Unit or Communications Unit Power supply Unit LG GR RS-422A/485 RS-422A/485 Signal line Signal line A-23

A-3-7 Connection Example An example of connecting a PLC and a using an RS-232C/RS-422A Converter is shown below. Use the wiring example as reference for correct wiring. CPU Rack (unit No. 0) (unit No. 1) Built-in RS-232C port on PCU unit RS-422A Converter (CJ1W-CIF11) RS-422A Converter () RS-422A Converter () 1:N NT Link Wiring Example Note: Refer to A-3-6 Handling the Shield on RS-422A/485 Cables for information on processing the shield wire on the RS-442A/485 cable. A-24