The various functions of an energy control center can be enumerated as under: 1. Load forecasting 6. Automatic generation control

Similar documents
""""FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI["

State-wise Gross State Domestic Product by Industry of Origin (at Prices) % Share to Total State GSDP at Constant Prices

Monthly changes in the General Indices and CFPIs are given below: Monthly changes (%) in All India CPI (General) and CFPI: Dec over Nov.

Employer Registration Help File

Employer Registration

Connectivity for NeGP. Presented By: Anil Kumar Balani Director Department of Information Technology

POWER SYSTEM SECURITY CONCEPTS

MoH&FW, Govt. of India, New Delhi

National e-governance Plan: State Data Centre (SDC) DVL Narayana Rao, Additional Director, DeitY

Handout on. Mobile Number Portability. For Sales Channels

NIRMAL XBRL GENERATOR

The modified file structure for the same is given in Annexure 1 of this circular for reference.

Controllers Address, Phone No., Fax No. &

Role of MoWR under NHP Avanish Kant, Sr. Hydrogeologist

up of SPMU in States/UTs under NeGP A

Highlights of Telecom Subscription Data as on 28 th February, 2018

Address and Tel.No. of the Director, Legal Metrology GOI

9.Telecommunication. India s first 3G mobile services by the state owned MTNL (Mahanagar Telephone Nigam Limited)

JSONRecharge API Document

Real-time Power System Operation. Energy Management Systems. Introduction

AUTOMATION OF POWER DISTRIBUTION USING SCADA

Shabnam Rukhsar Electrical Engineering Department, Anjuman College of Engineering and Technology.India

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Automation Services and Solutions

GRAS Education and Training Services Pvt. Limited ( GRAS Academy ) In Partnership with National Skills Development Corporation (NSDC)

SurvalentONE Distribution Management System

Blackout 101. Dr. B. Don Russell Texas A&M University. Dr. Bruce Wollenberg University of Minnesota. Mr. John McDonald KEMA, Inc.

Chapter 2 State Estimation and Visualization

CAPACITY BUILDING OF DISCOMS UNDER DEMAND SIDE MANAGEMENT SCHEME XII PLAN INITIATED BY

Highlights of Telecom Subscription Data as on 31 st October, 2018

Power System Controls

Parag Kar Vice President, Government Affairs Qualcomm India & South Asia. Managing Spectrum Auctions

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

Energy Efficiency Initiatives in Commercial Buildings. Bureau of Energy Efficiency Government of India

Tax Information Exchange System (TINXSYS) (For CTD Officials)

Phasor Technology Research Road Map to Improve Grid Reliability and Market Efficiency. Presented to TAC on April 5, 2005 and PAC on April 22, 2005

Distribution List: 1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi Chief Engineer (PSP&A II)

Mother and Child Tracking System. Achievements and Challenges

EMS-LECTURE 2: WORKING OF EMS

Telecom Regulatory Authority of India

Generation Interconnection Feasibility Study Report

CENTRAL PUBLIC PROCUREMENT PORTAL. System Administrators Guide for Tenders Meta Data transfer from Department Site to CPP Portal

HIGH LEVEL REQUIREMENTS OF FAST SIMULATION AND MODELLING SUITE OF TOOLS FOR FUTURE SELF-HEALING DISTRIBUTION POWER SYSTEM

Flexible High-Speed Load Shedding Using a Crosspoint Switch

Supplemental Information

Evolution of Control for the Power Grid

SCADA and Central Applications An introduction

A Background Note. Aadhaar - Issues and Implications

Standards Authorization Request Justification

Digital Transformation of Power Delivery

Solutions for transmission network management

This booklet has been prepared with the support under the GoI-UNDP Disaster Risk Reduction Programme ( )

Government Of India Ministry of Power Central Electricity Authority New Delhi

Economic Advisory Council to the Prime Minister. Government of India

Load Management of Industrial Facilities Electrical System Using Intelligent Supervision, Control and Monitoring Systems

Develop a platform to enable Government, private and social organizations to integrate social and commercial goals for benefit of the rural citizens

EMS / DMS. DISTRIBUTION MANAGEMENT SYSTEM- Functional Description

Interconnection and Transmission

Implementation of Wide Area Monitoring System for interconnected power system in India

Parag Kar Vice President, Government Affairs, Qualcomm India & South Asia 15 th June, Spectrum Sharing : Opportunities & Challenges

ATTACHMENT F Form of Service Agreement for Wholesale Network Integration Transmission Service

Policy Document on Grievance Redressal

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

Power System Network Simulator (PSNsim)

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

Synchronous switching of distribution sub networks

Concept of Automation in Management of Electric Power Systems Richard Joseph, Nerey Mvungi

Project Features. Power Sector Improvement Project (RRP KGZ ) $ 44.8 million (62.7% grant % loan) ADF amount:

Distributor Process Manual.

SEL Real-Time Automation Controller (RTAC)

SOUTH TEXAS ELECTRIC COOPERATIVE, INC.

GOVERNMENT OF INDIA MINISTRY OF COMMUNICATIONS DEPARTMENT OF TELECOMMUNICATIONS

Proposal for Development and Use of Node- Breaker Topology Representations for Offline and Real-time Study Models November 12, 2013

Chairman & MD, 40impeccable years of serving the Indian Industry

Comments by the Northeast Power Coordinating Council FERC Reactive Power Technical Conference

Standard EOP Disturbance Reporting

OC IEEE IAS/PES Meeting February 21, 2013

Real Time Monitoring of

Transmission Infrastructure Investment & Development in Vietnam

ERCOT Control Center Situation Awareness

Energy Audit at the Haridwar Plant of Mahindra & Mahindra A two member team of Counselors from the Energy Management Vertical conducted a four day det

WECC Remedial Action Scheme Design Guide November 28, 2006 i

Concept White Paper. Concepts for Proposed Content of Eventual Standard(s) for Project : Real-Time Monitoring and Analysis Capabilities

For internal circulation of BSNLonly

Grid Operations - Program 39

COGENERATION INTERCONNECTION REQUIREMENTS. Parallel Operation of Connecting Parties Generation

Road Transport Computerisation in Manipur

DRAFT Risks and Mitigations for Losing EMS Functions

SCADA Software. 3.1 SCADA communication architectures SCADA system

Lessons Learned Implementing an IEC based Microgrid Power- Management System. K.A. GRAY, J.J. MRAZ* POWER Engineers, Inc.

USE CASE 14 CONTROLLED ISLANDING

Invitation of sealed quotations for Renewal of Symantec Back up Executive.

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Case Study: Implementation of 132kv Malegaon Sub-Station Using SCADA


HVDC in CSG Challenges and Solutions

Secure energy supply Energy Automation for Infrastructure and Functional Buildings

NERC Event Analysis Update Webinar. Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016

IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO

CII - AVANTHA Centre sets its foot in the Footwear Industry AVANTHA launched a new Cluster with Bata India Limited-Kolkata and its vendors on January

Transcription:

ENERGY CONTROL CENTERS To generated, Transmission and Distribution system, Number of customers and Total investment. Installed capacity in India exceeds 206 GW with annual energy generated energy exceeding 1000 Billion KWh (1000 x 10 12 KWh). The power system feeds a very large number of domestic, commercial, industrial, agriculture and other customers. Operation and control of such a big interconnected power system is really challenging task and it cannot be done manually. Therefore power systems are controlled by using powerful computers installed at Energy Control Centers. The various functions of an energy control center can be enumerated as under: 1. Load forecasting 6. Automatic generation control 2. Planning studies 7. Reactive power management 3. System monitoring 8. Security control 4. State estimation 9. System maintenance 5. Unit commitment and economic dispatch

LEVELS OF POWER SYSTEM OPERATION AND CONTROL The total power system in India is not being operated in totally integrated manner. However, attempts are being made to achieve full integration. National Load Dispatching Center, having headquarters at New Delhi, is the coordinating agency. There are FIVE Regional Loading Dispatching Centers as described below. 1. Northern region load dispatching center at New Delhi covering states of HP, J and K, Haryana, Punjab, Rajasthan, UP, Delhi, Uttaranchal and Chandigarh. 2. Western region load dispatching center at Mumbai covering Gujarat, MP, Maharashtra, Chhattisgarh, Goa, Daman Diu, Dadra and Nagar Haveli. 3. Southern region load dispatching center at Bangalore covering AP, Karnataka, Tamil Nadu, Kerala, Pondicherry and Lakshadweep.

4. Eastern region load dispatching center at Kolkata covering WB, Bihar, Orissa, Sikkim and Jharkhand. 5. North eastern load dispatching center at Shillong covering Assam, Manipur, Meghalaya, Nagaland, Tripura, Arunachal Pradesh and Mizoram. Installed capacity in different regions are as follows: Northern Western Southern Eastern North eastern 56.1 GW 67.6 GW 53.3 GW 26.8 GW 2.4 GW The third level of consists of state load dispatching stations in each state capital.

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) Proper and efficient energy management system requires lot of data about the operating conditions. Further, many control actions are to be carried out at far off places. Executing such control actions manually will cause time delays resulting long outage duration and poor reliability. SCADA systems have been developed to overcome such problems. The following are the some of the main functions of SCADA. i) Data Acquisition: To provide data, measurements and status information to the operator. ii) Automatic generation control: To control the generations at the power plants. iii) Load Shedding: To make automatic load shedding in emergent conditions to avoid system collapsing. iv) Load Restoration: To restore the loads in steps to bring the system to normal state. v) Supervisory Control: To operate the circuit breaker remotely.

vi) Logging: To log all data and information in a systematic manner. vii) Alarms: To send alarm signals in case of undesirable operating conditions To fulfill the above operations SCADA has the following components. Sensors and Control Relays: Analog and digital sensors along with control relays which can interface with the system. Remote Terminal Units (RTU): RTUs are microprocessor controlled electronic devices deployed in field at specific sites and locations. They collect necessary data and transmit them to SCADA for processing. Master Unit: Large computer system which serves as a central processor. Communication Links Fiber optic / satellite / microwave communications are employed to link RTUs with SCADA. Necessary Softwares: To execute different operational problems

Figure 1 shows the layout of a typical SCADA system. console Printer Graphic Instrument Board MASTER COMPUTER UNIT(with required softwares) Modem CRT Modem Modem Modem System diagram RTU RTU RTU Fig. 1 Layout of SCADA

OPERATING STATES OF POWER SYSTEM For purpose of analyzing power system security and designing appropriate control systems, it is helpful to conceptually classify the system operating conditions into the following five states. Normal, Alert, Emergency, In extremis (or extreme emergency) and Restorative. Figure 2 depicts these operating states and the ways in which transition can take place from one state to another. Normal Restorative Alert In extremis Emergency Fig. 2 Power system operating states

NORMAL STATE: In the normal state, all system variables are within the normal range and no component is being overloaded. The system operates in a secure manner and is able to withstand a contingency without violating any of the constraints. ALERT STATE: The system enters the alert state if the security level falls below a certain limit of adequacy, or if the possibility of disturbance increases because of adverse weather conditions such as the approach of severe storms. In this state, all the system variables are still within the acceptable range and all the constraints are satisfied. However, the system has been weakened to a level where a contingency may cause an overloading of a component that places the system in an emergency state. If the disturbance is very severe, the in extremis state may result directly from the alert state.

EMERGENCY STATE: The system enters the emergency state, if a sufficiently severe disturbance occurs when the system is in the alert state. In this state, voltages at many buses are low and / or component loadings exceed the short-term emergency ratings. The system is still intact and may be restored to the alert state by initiating emergency control actions such as fault clearing, excitation control, fast-valving and load curtailment. If the above measures are not applied or are ineffective, the system will move to in extremis state.

IN EXTREMIS STATE: If the control action taken during the emergency state is insufficient, then the system enters into in extremis state. The result is cascading outages and possibly a shut-down of major portion of the system. Control actions, such as load shedding and controlled system separation, are aimed at saving as much system as possible from a widespread blackout. RESTORATIVE STATE: Preventive action, such as generation shifting or increased reserve, can be taken to restore the system to the normal state. If the restorative steps do not succeed fully, the system will move into the alert state. In case the control action taken are effective, the system moves to restorative state in which further action is being taken to reconnect all the facilities and to restore the system load. The system transits from the restorative state to either alert state or normal state, depending on the system conditions.

CONTROL STRATEGIES The control strategies which are to be adopted when the system is not in normal state can be summarized as under. Alert State: Preventive control to restore adequate spinning reserve, generation shifting, tie-line rescheduling and voltage reduction (if extremely needed) Emergency State: Immediate control to clear component overload, fast-valving, exciter control, load control, capacitor switching and all controls mentioned in alert state. In extremis State: Heroic action to control disruption of entire system, load shedding, controlled islanding and all controls mentioned in emergency state. Restorative State: Corrective control to re-establish viable system, generator units restarting and synchronization, load restoration, resynchronization of different islands and areas