QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

Similar documents
Wiring Accessories. low voltage. Wiring Accessories

1492-SP Supplementary Protectors

9926 Series Branch Rated Circuit Breakers AC Version

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Introduction Circuit Protection

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Jtec 10kA Miniature Circuit Breaker

Supplementary Circuit Protectors Type GSB63

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Miniature Circuit Breakers and Supplementary Protectors. Contents

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Section 4 Ground-Fault Protection Devices

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Applying branch circuit breakers and supplementary protectors in North America

Thermal-Magnetic Circuit Breaker 2216-S

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

UL 489 DIN rail branch circuit breakers

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

TeSys IEC Contactors and Overload Relays

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

IELR Rail-Mount Series Magnetic Circuit Protectors

60103 Circuit Breaker

Miniature Circuit-Breaker IEC Series 8562

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

PERCENT OF RATED CURRENT

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Allen-Bradley 1492-RCDA4A40

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Control Circuit and Load Protection Products

Miniature Circuit Breakers for Railway Applications

Applying branch circuit breakers and supplementary protectors in North America

Residual Current Devices drcm Digital

Thermal-Magnetic Circuit Breaker 4220-T...

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Protect Circuit Protection

UL 489 DIN Rail Miniature Circuit Breakers

WMS SUPPLEMENTARY PROTECTORS

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

TeSys protection components

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Bulletin 1489 Circuit Breakers. Selection Guide

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Protection Equipment

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Circuit Breakers Type CTI 25M, CTI 45MB

IELR Series

Selection Guide. Control Circuit and Load Protection

For Sales and Support call KMParts.com (866)

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Selection Guide. Control Circuit and Load Protection

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

Overvoltage Protection Devices

Introduction Electronic Circuit Protection ESX10-T

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Installation Instructions H Series

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Motor protection circuit breakers

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

US Catalog July 2016 SMISSLINE TP

Combined RCD/MCB Devices FRBmM, 1+N-pole

Product Guide. UL 489 DIN rail miniature circuit breakers

VAL-CP-1S-175. Extract from the online catalog. Order No.:

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

B60 Domestic Voltage Optimisation Unit

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Installation Instructions

D-Series. Circuit Breaker

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Transcription:

1 pole 2 pole 3 pole 3+N Features AC Circuit Breaker Hydraulic-Magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N (VDE) VC 8036 compliant (SANS 556-1) VDE approved, CE certified Ratings 70 to (subject to certification) Available in various currents and time delays Precision tripping characteristics Reset immediately after overload product in black shells Suitable to use for electrical isolation Applications AC branch circuit protection (IEC / EN 60947-2) Switch Disconnector (IEC / EN 60947-3) Switch Disconnector 3+N (IEC / EN 60947-3; CCC; UL 508) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Optional Accessories Handle lock Surface mounting clips Busbar Escutcheon blank Safety blank Page 1 of 6

Technical Data low voltage Product Type Circuit Breaker Approvals VC 8036 (SANS 556-1) Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 70 A Maximum Current Rating Interrupting Capacity 5 ka Product Type Circuit Breaker Approvals IEC / EN 60947-2, VDE Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 70 A Maximum Current Rating Interrupting Capacity 6 ka Product Type Switch Disconnector Approvals VC 8036 (SANS 556-1), IEC / EN 60947-3, VDE, CCC Number of Poles 1 2 3 4 Operating Voltages 240 V AC 415 V AC Current Rating Short-time Withstand 6 ka Description Operating Temperature Range -40 o C to +85 o C Mounting Options Dual mounting (DIN & Mini), surface mount Time Delay Curves 1, 2 Breaker QF Wire Size mm² (IEC) Torque (IEC) Comments 1 Pole to 4 Pole 1-50 mm² 4 Nm Pozidriv #2 Combi head Page 2 of 6

Long Code continues Example Code: QF-----3(26)-DM-2-125A------ Group 1 2 3 4 5 6 7 8 9 10 11 Requirement QF Frame Switch / Neutral Not applicable Triple pole 26 mm module width Dual Mount Medium delay curve 2 Current Rating Future use Shunt Trip Future use Long Code QF - - 3 (26) DM 2 125A - - - Group 1: Frame Type Group 2: Switch/Neutral Group 3: Auxiliary Group 4: No of Poles Group 5: Module Width Group 6: Mounting Group 7: Time Delays Group 8: Current Ratings QF 26 mm wide Miniature Circuit Breaker / Switch Disconnector - Not applicable Overload poles do not have any further coding S Switch Green handle N Neutral - Not applicable 1 Single pole 2 Double pole 2 pole or 1+N 3 Triple pole 4 Four pole 4 pole 3+N or only 3+N (26) 26 mm module width 26 mm per pole DM 57 Dual mm Mount Escutcheon, black body supplied in black supplied body in only black - 57 only mm Escutcheon Code Description Instantaneous Trip Point (x In) Comments 1 Long time delay, high instantaneous trip 10 20 Orange handle 2 Medium time delay 5 10 White handle 3 Code Short / Description time delay 3 5 Comments White handle 9 70, 80, Long 90,, time 125 delay A 7 12 White handle Group 9: Code For future use (-) Group 10: Shunt Trip - Not applicable Use this code if no Shunt Trip is used Group 11 Code For future use (-) For options not listed, please contact CBI for assistance Page 3 of 6

Time Delay Curves 000 OPERATING CHARACTERISTICS 00 CURVE 1 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current * The published time delay curves are generated at 30 o C ambient temperature with the Circuit Breaker mounted in the up-right position. The must hold, must trip and instantaneous trip current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Page 4 of 6

Outline Dimensions: low voltage 000 OPERATING CHARACTERISTICS 00 CURVE 2 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current Page 5 of 6

Outline Dimensions: 61.0 [2.402] 5.0 [0.197] 49.6 [1.953] 25.6 ± 0.4 [1.008 ± 0.0157] 51.2 ± 0.8 [2.016 ± 0.0315] 76.8 ± 1.2 [3.024 ± 0.0472] 102.4 ± 1.6 [4.031 ± 0.0630] 19.6 [0.774] 113.4 [4.465] 57.0 [2.244 ] 24.8 [0.976] 51.6 [2.031] 25.6 [1.008] 64.5 [2.539] 82.0 [3.228] (nominal) (nominal) All dimensions in mm [ inch ] Tolerance ± 0.4 unless otherwise specified Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 90 Fairbank Road Clayton South Melbourne Victoria 3169 Australia Tel: +61 3 9590 3500 Fax: +61 3 9551 1051 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com Page 6 of 6 A member of the Group