Strand Lighting Specification

Similar documents
P10 P11 P12 P14 P13 USER

550i. High capability control consoles ;~ STRAND LIGHTING DATA SHEETS Features

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

GS Dupline Profinet Gateway. Benefits. Description

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

Strand Lighting Specification

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Installation Instructions

Windows-Based Terminal. TK-3550 H.W. Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SAVE THESE INSTRUCTIONS

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

4K8 8-port Ethernet 10/100 Switch, 4K-Series

PRODUCTS: CONTROLLERS

Web interface BACnet/IP

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

10/100Base-TX Industrial Ethernet Extender

Power supply module, bus connection module

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

FLEX Ex Spring Clamp Terminal Base

304TX-N. Phone: Fax: Web:

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:


IntesisBox Modbus Server Panasonic

10/100Base-TX Industrial Ethernet Extender

LNP-800AGH-24 Series. Features INTRODUCTION DIMENSIONS

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

LED Indicator. Class I

IntesisBox Modbus Server Fidelio IP

MGate 5102-PBM-PN Series

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Features: Example of use

JPEG p Low Latency Video over IP Encoder with KVM, PoE, SFP, HDMI NMX-ENC-N2135 (FGN2135-SA), Stand Alone NMX-ENC-N2135-C (FGN2135-CD), Card

Server Remote Control External KVM over IP

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

6GK6050-0MM Transmission rate. Interfaces

Models HP Z VR Backpack G1 Dock

114FX6. Phone: Fax: Web: -

Product and functional description

JPEG 2000 Digital Cinema Grade Video over IP Encoder, PoE, HDMI

Model DMX24DIM Installation and Operations Manual

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600


Modbus Server SIEMENS Algorex (printer port)

NEO LIGHTING CONTROL CONSOLE

Power Meter PowerMonitor 500

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Industrial PC - VL BPC

Book ; Book TOC Page 1 Black Wednesday, 20 September :21. A publication of CDS electronics bv, Maassluis, The Netherlands

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

SPECIAL SPECIFICATION 1303 Lifelink

305FX-N. Phone: Fax: Web:

Corning Optical Network Evolution (ONE ) Solutions Mid-Power Remote Expansion Unit (MxU)

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS1600 managed

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

TRC-190 User s Manual

TOKISTAR. Light Veil Series TOKISTAR LIGHTING

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ex-s1110-xt Gigabit Ethernet Extenders

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

6GK6096-8MS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

DANTE BRIDGE. Operation Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Control different load types with one device

TTX400-3U-1S Watt, 3U, 1 Slot, 24VDC Input, CompactPCI Power Supply. CompactPCI POWER SUPPLY

/ Outdoor Diplexer DPO-6789B-X-XX

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

6GK6041-6AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS416 managed

Power Supply HARTING pcon

AB Axis Industries. Use

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

8 Port Rackmount USB VGA KVM Switch w/ Audio (Audio Cables Included) StarTech ID: SV831DUSBAU

De-multiplexed Display Driver. Revision 02. User Manual. TM117-DMX Motherboard Daughterboard

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

High Efficiency. LED Status Indicator. IPX1 Rated. CEC Compliant

6GK6096-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

S-Band Redundant LNA Systems

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS8000 managed

connecdim Gateway G1 Ethernet TCP/IP to DALI

Refurbished 1U 19in Rackmount LCD Console with Integrated 8 Port KVM Switch

Power Supply HARTING pcon

Transcription:

I. SHOWNET ETHERNET SIGNAL DISTRIBUTION 1. The Strand Lighting ShowNet network shall provide data distribution over a TCP/IP ethernet Network. Systems using proprietary formats or formats other than TCP/IP shall not be accepted. 2. Connections shall be made between consoles, computers and SN series nodes over a standard Ethernet distribution systems using 10Base2 or 10/100BaseT wiring or a combination of both. All installations shall conform to established Ethernet wiring practice and installation shall be performed by contractors qualified to do this type of work. All wiring shall be tested for full bandwidth operation to the appropriate IEEE standard. B. CAPACITIES 1. The Network shall provide DMX routing and patching for up to 18,432 DMX addresses and DMX data may be output in a variety of output formats to any DMX node in the system. DMX input, routing and output shall be specifically supported on the system from multiple sources and locations with up to 99 nodes. 2. The system shall support multiple consoles, computers, file servers, printers with discrete command lines and control. The ShowNet system may support multiple facilities within a complex. 3. System configuration shall be via Strand ShowNet Windows software and permit simple point and click connection between Consoles and Nodes, Consoles and Consoles, and Consoles and File Servers. The software shall permit complete user flexibility allowing the system operator to define DMX data groups, Node Names and console names for easy identification. Each node shall have a specific user selectable IP address. Systems that do not support simple Windows operation shall not be acceptable. 4. All configuration data for each Network device shall be held at the device and system operation shall not require continuous on line operation of the Network configuration software. 5. ShowNet Interface List The following interfaces shall be provided on each network: a. Remote Handheld Control b. Serial Data (Remote Dimmer Supervisor) c. Multiple Remote Printers d. Serial Data (Spare) e. Universal DMX512 Dimmer Mux up to 18,432 outputs (36 standard DMX Universes) f. Remote Faders and Switches g. MIDI Input h. MIDI Through i. MIDI Output C. OPERATIONAL FEATURES 1. The video monitor outputs at any video node shall be able to monitor the video output of any Lightpalette console connected to the Ethernet with Networker software. Each Video node shall have discrete dsiplay access to any console and any console display. 2. Each Node shall control up to 2048 DMX addresses, within the confines of an up to a 36 DMX (18,432 DMX addresses) universe system. The specific DMX data input or output by the Node shall be freely configurable by the user. Duplicate outputs of DMX lines (DMX splitter) and discrete outputs shall be fully supported. 3. Any number of DMX lines may be configured with any length up to 512 addresses as long as the total does not exceed 18,432. Any range of DMX addresses may be selected for each feed and may be any set of 512 numbers from the total available on the network. Numbers may be selected in any order and the use of and plus thru commands shall be supported with ShowNet Professional Page 1

software. Multiple sources may be combined on any node output and a priority may be assigned to each source. Each DMX output on each node may have its own label and start address for ease of use. 4. DMX ports shall be configurable for either input or output. Multiple DMX signal routing patches and Multiple facilities shall be specifically supported and limited only by the file storage capacity of the computer with ShowNet software installed. 5. The Network shall support Parallel, Remote and Tracking Back up operation of 300 and 500 series control consoles. 6. File transmission, synchronization and access to File Servers using Microsoft NT server software shall be specifically supported. 7. All Network configuration information shall be available as a system printout. Specific printouts shall be available to assist in trhe addressing of DMX devices on the network. II. SN100 ADVANCED ETHERNET NODE 1. The Strand Lighting SN100 network node shall be an intelligent, table top or wall mountable Ethernet node providing lighting services remote from the console when used with Strand ShowNet software. 2. Connections shall be made between consoles and SN100s over standard Ethernet distribution systems using 10Base2 or 10BaseT wiring or a combination of both. Each SN100 shall be equipped with power and network OK LEDs, twin 100mm faders and four display selection keys with LEDs. It shall incorporate a universal 100-120v / 220-240v power supply. It shall be designed and manufactured by a company operating a quality system approved to ISO9001. It shall be CE, UL & cul listed. B. PHYSICAL 1. The Node electronics will be mounted in a 12.9 (330mm) W x 6.5 (165mm) D x 2.6 (65mm) H enclosure, finished in powder coat grey. The front panel will be silk screened with the product identification details. 2. The weight of the Node shall be 6.8lb (3.1kg). 3. The Node enclosure shall be a Zinc coated steel box construction with flame proof ABS controls. 4. The Node shall have a 100-240V 50/60Hz, auto-sensing Power Supply. 5. The Node shall have a High Density, 3.5 disk drive, for programming and archival storage of node configuration, as well as for software upgrades. 6. SN100 Interface List The following interfaces shall be provided on each SN100 network node: a. VGA Output 1 b. VGA Output 2 c. Keyboard (Mini DIN) d. Remote Handheld Control e. Serial (Remote Dimmer Supervisor) f. Parallel Printer Port g. Serial (Digitizer) h. Universal DMX512/SMX Dimmer Mux I/O 1 i. Universal DMX512/SMX Dimmer Mux I/O 2 j. Remote Faders and Switches k. MIDI Input l. MIDI Through m. MIDI Output Page 2

n. Mains Power Input o. Ethernet 10BaseT p. Ethernet 10Base2 C. ELECTRONICS 1. The node processor shall be an Intel 386. 2. Configuration of the Node shall be stored in Static RAM. D. OPERATIONAL FEATURES 1. The video monitor outputs shall be able to monitor the video output of any 300 or 500 series console connected to an Ethernet network. 2. The Node shall control up to 1024 DMX channels, within the confines of an up to 36 DMX universe system. The specific DMX channels input or output by the Node shall be freely configurable by the user. 3. The DMX ports shall be configurable for either input or output. 4. The RS 232 port shall be configurable as an RS 232 or RS 485 data input onto the network to support data transmission, focus remotes or dimmer status reporting. 5. The Node shall be remotely configured by an IBM PC compatible computer, via the network system wiring, or locally, using the disk drive, a keypad, a video monitor and Networker software (supplied with console software package). E. ENVIRONMENTAL 1. The ambient operating temperature shall be 0 to 40 C (32 to 104 F). 2. The storage temperature shall be -40 to 70 C (-40 to 158 F). 3. The operating humidity shall be 5% - 95% non-condensing. F. STANDARDS COMPLIANCE 1. EMC emissions to EN50081-1, EN55014; EMC immunity to EN50082-1, IEC1000-2-2; Safety: EN60950, EN60439 Part 1 (also part 12 BS5486); design & build: ISO9000, UL1950. 2. The Node shall be CE, UL & cul listed. G. INCLUDED FURNISHINGS 1. Power cord 2. ShowNet Network Configuration Software a. Windows based software to configure DMX over Ethernet data distribution systems for use with Networker or stand alone configurations. b. Configurations can be saved to disk on PC and down-loaded to nodes when required. PC is not required to run ShowNet. III. SN102 ADVANCED RACK MOUNT ETHERNET NODE 1. The Strand Lighting SN102 network node shall be an intelligent, 19 rack mounted Ethernet node providing lighting services remote from the console when used with Strand Networker software. 2. Connections shall be made between consoles and SN102s over standard Ethernet distribution systems using 10Base2 or 10BaseT wiring or a combination of both. Each SN102 shall be equipped with power and network OK LEDs, and four select keys with LEDs. It shall incorporate a universal 100- Page 3

120v / 220-240v power supply. It shall be designed and manufactured by a company operating a quality system approved to ISO9001. It shall be CE UL & cul listed. B. PHYSICAL 1. The Node electronics will be mounted in a 19 (483mm) W x 10.2 (260mm) D x 3.5 (88mm, 2U) H enclosure, finished in powder coat grey. The front panel will be silk screened with the product identification details. 2. The weight of the Node shall be 7.7lb (3.5kg). 3. The Node enclosure shall be a Zinc coated steel box construction with flame proof ABS controls. 4. The Node shall have a 90-264V 50/60Hz, auto-sensing Power Supply. 5. The Node shall have a High Density, 3.5 disk drive, for programming and archival storage of node configuration, as well as for software upgrades. 6. SN102 Interface List The following interfaces shall be provided on each SN102 network node: a. VGA Output 1 b. VGA Output 2 c. Keyboard (Mini DIN) d. Remote Handheld Control e. Serial (Remote Dimmer Supervisor) f. Parallel Printer g. Serial (Spare) h. Universal DMX512/SMX Dimmer Mux I/O 1 i. Universal DMX512/SMX Dimmer Mux I/O 2 j. Remote Faders and Switches k. MIDI Input l. MIDI Through m. MIDI Output n. Mains Power Input o. Ethernet 10BaseT p. Ethernet 10Base2 C. ELECTRONICS 1. The node processor shall be an Intel 386. 2. Configuration of the Node is stored in Static RAM. D. OPERATIONAL FEATURES 1. The video monitor outputs shall be able to monitor the video output of any 300 or 500 Series console connected to the Ethernet with Networker software. 2. The Node shall control up to 1024 DMX channels, within the confines of an up to 36 DMX universe system. The specific DMX channels input or output by the Node shall be freely configurable by the user. 3. The DMX ports shall be configurable for either input or output. 4. The RS 232 port shall be configurable as an RS 232 or RS 485 data input onto the network to support data transmission, focus remotes or dimmer status reporting. 5. The Node shall be remotely configured by an IBM PC compatible computer, via the network system wiring, or locally, using the disk drive, a keypad, a video monitor and Networker software (supplied with console software package). Page 4

E. ENVIRONMENTAL 1. The ambient operating temperature shall be 0 to 40 C (32 to 104 F). 2. The storage temperature shall be -40 to 70 C (-40 to 158 F). 3. The operating humidity shall be 5% - 95% non-condensing. F. STANDARDS COMPLIANCE 1. EMC emissions to EN50081-1, EN55014; EMC immunity to EN50082-1, IEC1000-2-2; Safety: EN60950, EN60439 Part 1 (also part 12 BS5486); design & build: ISO9000, UL1950. 2. The Node shall be CE UL & cul listed. G. INCLUDED FURNISHINGS 1. Power cord 2. ShowNet Network Configuration Software a. Windows based software to configure DMX over Ethernet data distribution systems for use with Networker or stand alone configurations. b. Configurations can be saved to disk on PC and down-loaded to nodes when required. PC is not required to run ShowNet. IV. SN103 DMX ETHERNET NODE 1. The SN103 Node shall be an intelligent, wall mounting, Ethernet node providing DMX and Reporter Dimmer data distribution. 2. Connections shall be made between nodes over standard Ethernet distribution systems using 10BaseT or 100BaseT wiring or a combination of systems. Each Node shall be equipped with power and network OK LEDs, termination switches for each of the XLR connectors, and mimic LEDs to indicate the termination status. It shall incorporate a universal 100-240V power supply. It shall be designed and manufactured by a company operating a quality system approved to ISO9001. It shall be CE UL & cul listed. B. PHYSICAL 1. The Node electronics will be mounted in a 8 (203mm) W x 4 (101mm) D x 8 (203mm) H enclosure, finished in powder coat gray. The front panel will be silk screened with the product identification details. 2. The weight of the Node shall be 7.7lbs (3.5kg). 3. The Node enclosure shall be a Zinc coated steel box construction with flame proof ABS controls. 4. The Node shall have a 100-240V 50/60Hz, auto-sensing Power Supply. Terminals shall also be supplied to allow the node to be supplied with mains line power. 5. The Node shall feature a total of 4 XLR connectors on the front panel. Each XLR connector shall feature a Line termination switch and an LED that indicates when the switch is engaged. a. There shall 4 DMX512 (512 dimmers per port, selectable In/Out), 5 pin female XLR connectors standard. b. It shall be possible to factory configure the connectors to be male or female and 5 or 6 pin to meet project requirements. 6. The XLR references will be marked on the front panel, but a space will be provided for a self adhesive custom label strip of approximately 7 x0.5 x 0.05 Page 5

C. ELECTRONICS 1. The node processor shall be an Intel 386EX. 2. Configuration of the Node is stored in Static RAM. D. OPERATIONAL FEATURES 1. The Node shall be remotely configured by an IBM PC compatible computer, via the network system wiring. 2. The Node shall control up to 2048 DMX channels, within the confines of an up to 36 DMX universe system. The specific DMX channels input or output by the Node shall be freely configurable by the user. 3. All ports may be configured as a DMX input or output. Ports 3 and 4 may also configured as an RS 232 or RS 485 data input onto the network to support data transmission, and dimmer status reporting. Handheld remote operation shall also be available as an option on all nodes. E. ENVIRONMENTAL 1. The ambient operating temperature shall be 0 to 40 C (32 to 104 F). 2. The storage temperature shall be -40 to 70 C (-40 to 158 F). 3. The operating humidity shall be 5% - 95% non-condensing. F. STANDARDS COMPLIANCE 1. EMC emissions to EN50081-1, EN55014; EMC immunity to EN50082-1, IEC1000-2-2; Safety: EN60950, EN60439 Part 1 (also part 12 BS5486); design & build: ISO9000, UL1950. 2. The Node shall be CE, UL & cul listed. G. INCLUDED FURNISHINGS 1. ShowNet Network Configuration Software a. Windows based software to configure DMX over Ethernet data distribution systems for use with Networker or stand alone configurations. b. Configurations can be saved to disk on PC and down-loaded to nodes when required. PC is not required to run ShowNet. V. SN104 DMX ETHERNET NODE 1. The SN104 Node shall be an intelligent, wall mounting, Ethernet node providing DMX and Reporter Dimmer data distribution. 2. Connections shall be made between nodes over standard Ethernet distribution systems using 10BaseT or 100BaseTX wiring or a combination of systems. Each Node shall be equipped with power and network OK LEDs, termination switches for each of the XLR connectors, and mimic LEDs to indicate the termination status. It shall incorporate a 48VDC power supply. It shall be designed and manufactured by a company operating a quality system approved to ISO9001. It shall be UL & cul listed. Page 6

B. PHYSICAL 1. The Node electronics will be mounted in a 8 (203mm) W x 4 (101mm) D x 8 (203mm) H enclosure, finished in powder coat gray. The front panel will be silk screened with the product identification details. 2. The weight of the Node shall be 7.7lbs (3.5kg). 3. The Node enclosure shall be a Zinc coated steel box construction with flame proof ABS controls. 4. The Node shall have a 48V DC power supply. 5. The Node shall feature a total of 4 XLR connectors on the front panel. Each XLR connector shall feature a Line termination switch and an LED that indicates when the switch is engaged. a. There shall 4 DMX512 (512 dimmers per port, selectable In/Out), 5 pin female XLR connectors standard. b. It shall be possible to factory configure the connectors to be male or female and 5 or 6 pin to meet project requirements. 6. The XLR references will be marked on the front panel, but a space will be provided for a self adhesive custom label strip of approximately 7 x0.5 x 0.05 C. ELECTRONICS 1. The node processor shall be an Intel 386EX. 2. Configuration of the Node is stored in Static RAM. D. OPERATIONAL FEATURES 1. The Node shall be remotely configured by an IBM PC compatible computer, via the network system wiring. 2. The Node shall control up to 2048 DMX channels, within the confines of an up to 36 DMX universe system. The specific DMX channels input or output by the Node shall be freely configurable by the user. 3. All ports may be configured as a DMX input or output. Ports 3 and 4 may also configured as an RS 232 or RS 485 data input onto the network to support data transmission,and dimmer status reporting. Handheld remote operation shall also be available as an option on all nodes. E. ENVIRONMENTAL 1. The ambient operating temperature shall be 0 to 40 C (32 to 104 F). 2. The storage temperature shall be -40 to 70 C (-40 to 158 F). 3. The operating humidity shall be 5% - 95% non-condensing. F. STANDARDS COMPLIANCE 1. EMC emissions to EN50081-1, EN55014; EMC immunity to EN50082-1, IEC1000-2-2; Safety: EN60950, EN60439 Part 1 (also part 12 BS5486); design & build: ISO9000, UL1950. 2. The Node shall be CE UL & cul listed. G. INCLUDED FURNISHINGS 1. ShowNet Network Configuration Software a. Windows based software to configure DMX over Ethernet data distribution systems for use with Networker or stand alone configurations. b. Configurations can be saved to disk on PC and down-loaded to nodes when required. PC is not required to run ShowNet. Page 7

Page 8