NPort 5200 Series Quick Installation Guide

Similar documents
NPort 5100 Series Quick Installation Guide

NPort 6150/6250 Series Quick Installation Guide

NPort 5400 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide

NPort W2150A/W2250A Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide

OnCell G3100 Series Quick Installation Guide

MGate 5118 Quick Installation Guide

NPort 5200 Series. 2-port RS-232/422/485 serial device servers. Specifications. Serial-to-Ethernet Device Servers

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Serial/Ethernet Converter

MGate 5105-MB-EIP Quick Installation Guide

Features and Benefits. Compact design for easy installation. Certifications

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

DT Desktop Series

Features and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.

MGate 5111 Quick Installation Guide

MGate 4101-MB-PBS Series

UC-8410A Quick Installation Guide

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

MGate 5102-PBM-PN Series

Features and Benefits. SNMP MIB-II for network management. Certifications

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

NPort Z2150/Z3150 Series

TN-5308 Quick Installation Guide

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

MGate 5105-MB-EIP Series

TCF-142 Quick Installation Guide

IA240/241 Hardware User s Manual

NPort 5600 Series. 8 and 16-port RS-232/422/485 rackmount serial device servers. Overview. Serial-to-Ethernet Device Servers

Features and Benefits. Certifications

UPort 1200/1400/1600 Quick Installation Guide

Features and Benefits. Certifications

Modbus TCP/RTU Gateway

Features and Benefits. Certifications

UPort TM 200/400 Series Quick Installation Guide

NPort 5000AI-M12 Series

Feature and Benefits. Certifications

UPort 1200/1400/1600 Quick Installation Guide

UC-7112-LX Plus/UC-7112/UC-7110 Hardware User s Manual

Features and Benefits. Certifications

Features and Benefits. Fast 3-step web-based configuration. Certifications

ABC-02-USB Quick Installation Guide

Features and Benefits. Certifications

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

Moxa TCC-100 Series Hardware Installation Guide

EDR-G902/G903 Quick Installation Guide

UC-7101 Hardware User s Manual

IKS-G6524A/G6824A Series Quick Installation Guide

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Features and Benefits. Certifications

INJ-24A Series Quick Installation Guide

UC-7400 Plus Hardware User s Manual

CP-114EL/CP-114EL-I Quick Installation Guide

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

NPort Z2150 User s Manual

NPort 5100A Series. 1-port RS-232/422/485 serial device servers. Overview. A Greener Serial-to-Ethernet Solution

iologik E1200H Series

DA-820 Series Quick Installation Guide

UC-2100 Series Hardware User s Manual

IMC-21A Quick Installation Guide

NPort 6400/6600 Series

ICS-G7526A/G7528A/ G7826A/ G7828A Series Quick Installation Guide

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

TCF-142-RM Series Hardware Installation Guide

MGate MB3000 Modbus Gateway User s Manual

UC-8410 Hardware User s Manual

UPort 2000 Series User s Manual

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Features and Benefits. Certifications

IMC-21 Quick Installation Guide

ICF-1150 Series Quick Installation Guide

EDR-810 Series Quick Installation Guide

TRC-190 User s Manual

OnCell G3150A-LTE Series

ICF-1150 Series Quick Installation Guide

Features and Benefits. Certifications

EDS-405A-PTP Series Hardware Installation Guide

Media Converters. Media Converters. Product Selection Guides

V2403 Quick Installation Guide

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

Moxa TCC-100 Series User s Guide

Features and Benefits. Certifications

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications

ThinkCore IA241/240 Hardware User s Manual

Features and Benefits. Certifications

Moxa ToughNet Switch

ICS-G7748A/G7750A/ G7752A/G7848A/G7850A/ G7852A Series Quick Installation Guide

IMC-21GA Quick Installation Guide

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

EDS-G205A-4PoE Quick Installation Guide

MGate MB3000 Modbus Gateway User Manual

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

UC-8410/8416/8418/8430 Hardware User s Manual

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

Features and Benefits. Certifications

MGate MB3000 Modbus Gateway User s Manual

Moxa Video Encoder. VPort 251 Series Quick Installation Guide. Second Edition, June 2008

Transcription:

NPort 5200 Series Quick Installation Guide Edition 8.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa India: Tel: +91-80-4172-9088 Fax: +91-80-4132-1045 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 2017 Moxa Inc. All rights reserved. P/N: 1802052000313 *1802052000313*

Overview The NPort 5200 compact palm-sized device servers are used to control RS-232 (NPort 5210/5230/5210-T/5230-T) or RS-422/485 (NPort 5230/5232/5232I/5230-T/5232-T/5232I-T) serial devices over a TCP/IP-based Ethernet. NOTE -T indicates an extended operating temperature model. Package Checklist Before installing your NPort 5200, verify that the package contains the following items: 1 NPort 5200 2-port Serial Device Server Documentation & Software CD Quick Installation Guide (printed) Warranty card Optional Accessories DK-35A: DIN-Rail Mounting Kit (35 mm) CBL-RJ45M9-150: RJ45 (8-pin) to DB9 (M) cable, 150 cm CBL-RJ45F9-150: RJ45 (8-pin) to DB9 (F) cable, 150 cm CBL-RJ45M25-150: RJ45 (8-pin) to DB25 (M) cable, 150 cm CBL-RJ45F25-150: RJ45 (8-pin) to DB25 (F) cable, 150 cm DIN-Rail Power Supply and Adapter Note: Notify your sales representative if any of the above items are missing or damaged. Hardware Introduction The NPort 5200 device servers are used to control RS-232/422/485 devices. The NPort 5210/5210-T has two 8-pin RJ45 ports, both for the RS-232 interface. The NPort 5230/5230-T has one 10-pin terminal block, with 5 pins used for one RS-232 port, and 5 pins used for one RS-422/485 port. The NPort 5232/5232I/5232-T/5232I-T have one 10-pin terminal block, with 5 pins used for one RS-422/485 port, and 5 pins used for another RS-422/485 port. - 2 -

Reset Button Press the Reset button continuously for 5 sec to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds). At this point, you should release the reset button. NPort 5200 LED Indicators (top panel) LED Name LED Color LED Function Steady on: Power is on and the NPort 5200 is booting up. Red Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond Ready properly. Steady on: Power is on and the NPort 5200 is Green functioning normally. Blinking: The device server has been located by Administrator s Location function Off Power is off, or power error condition exists. Orange 10 Mbps Ethernet connection. Ethernet Green 100 Mbps Ethernet connection. Off Ethernet cable is disconnected, or has a short. Orange Serial port is receiving data. Green Serial port is transmitting data. P1, P2 No data is being transmitted or received through Off the serial port. - 3 -

Hardware Installation Procedure STEP 1: After removing the NPort 5200 from the box, the first thing you should do is connect the power adapter. Connect the 12-30 VDC power line with the NPort 5200 s terminal block, or connect the DIN-rail power supply with the NPort 5200 s terminal block. STEP 2: Connect the NPort 5200 to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch. When setting up or testing the NPort 5200, you might find it convenient to connect directly to your computer s Ethernet port. In this case, use a cross-over Ethernet cable. STEP 3: Connect the NP ort 5200 s serial port to a serial device. STEP 4: Placement Options In addition to placing the NPort 5200 on a desktop or other horizontal surface, you may also make use of the DIN-rail or wall mount options, as illustrated here. Wall Mount DIN-Rail Software Installation Information To install NPort Administration Suite, insert the NPort Document & Software CD into your computer s CD-ROM drive. Once the NPort Installation CD window opens, click on the Installation button, and then follow the instructions on the screen. To view detailed information about NPort 5200 Administration Suite, click on the Documents button, and then select NPort 5200 Series User s Guide to open the pdf version of this user s guide. The PComm Lite program is also included in the Documentation & Software CD free of charge. Install PComm Lite to use the Serial Console for configuring the IP address for the first time. Pin Assignments and Cable Wiring NPort 5230/5230-T Terminal Block Wiring - 4 -

NOTE The NPort 5232/5232I/5232-T/5232I-T have 2 RS-422/485 ports. The pin assignments are the same as the NPort 5230/5230-T s port 2. Refer to the NPort 5200 Series User s Manual for more details. Pin Assignments and Cable Wiring NPort 5210/5210-T RJ45 (8-pin) Connector Pinouts 8-Pin Signal 1 DSR 2 RTS 3 GND 4 TxD 5 RxD 6 DCD 7 CTS 8 DTR Cable Wiring (RS-232) Four cables are available as optional accessories to connect the NPort 5210/5210-T to RS-232 serial devices. For your convenience, we show precise cable wiring diagrams for each of the four cables. RJ45 (8-pin) to DB25 Female (Cable Name: CBL-RJ45F25-150) RJ45 (8-pin) to DB25 Male (Cable Name: CBL-RJ45M25-150) - 5 -

RJ45 (8-pin) to DB9 Female (Cable Name: CBL-RJ45F9-150) RJ45 (8-pin) to DB9 Male (Cable Name: CBL-RJ45M9-150) Specifications Power Requirements NPort 5210/5210-T: 12 to 48 VDC, 325 ma at 12V (max.) NPort 5230/5230-T: 12 to 48 VDC, 325 ma at 12V (max.) NPort 5232/5232-T: 12 to 48 VDC, 280 ma at 12V (max.) NPort 5232I/5232I-T: 12 to 48 VDC, 365 ma at 12V (max.) Operating Temp. Standard models: 0 to 55 C (32 to 131 F) T models: -40 to 75 C (-40 to 167 F) Operating humidity: 5 to 95% RH Dimensions NPort 5210/5230/5232/5210-T/5230-T/5232-T (including ears): 90 100.4 22 mm (3.54 3.95 0.87 in) NPort 5210/5230/5232/5210-T/5230-T/5232-T (without ears): 67 100.4 22 mm (2.64 3.95 0.87 in) NPort 5232I/5232I-T (including ears): 90 100.4 35 mm (3.54 3.95 1.37 in) NPort 5232I/5232I-T (without ears): 67 100.4 35 mm (2.64 3.95 1.37 in) - 6 -

Regulatory Approvals Safety UL 60950-1 EMC EN 55032/24 EMI CISPR 32, FCC Part 15B Class A EMS IEC 61000-4-2 ESD: Contact: 4 kv; Air: 8 kv IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kv; Signal: 0.5 kv IEC 61000-4-5 Surge: Power: 1 kv IEC 61000-4-6 CS: 150 khz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs Marine DNV (excluding the NPort 5210) Medical (NPort 5210 only) EN 60601-1-2 Class B, EN55011-7 -