IntelliLink Setup Software

Similar documents
Docking Station Instructions

Source-Transfer Application Guide

Primary Injection Test Procedure

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

Wi-Fi and Security Administration

PS/IO Circuit Board Retrofit

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Troubleshooting Instructions

Instructions for Operation of S&C Test Accessory Catalog Number TA-2669

Installation and Operation

Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

Wi-Fi Administration and Operation

Vista SD Portable Remote Control Pendant

User s Guide. S&C IntelliTeam Designer. Table of Contents. Instruction Sheet

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Quick-Start Programming

Communications Card Operation

Operation. S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Table of Contents

Troubleshooting. S&C IntelliCap 2000 Automatic Capacitor Control. Table of Contents. Instruction Sheet

Setup. Section Page Section Page NOTICE

Setup Instructions. S&C Universal Interface Module. Table of Contents. Instruction Sheet

Troubleshooting. S&C IntelliCap Automatic Capacitor Control. Instruction Sheet Table of Contents

Troubleshooting. S&C 6801M Automatic Switch Operators Reciprocating and Rotating Switch Operation. Table of Contents. Instruction Sheet 1045M-550

Troubleshooting. S&C IntelliCap Plus Automatic Capacitor Control. Table of Contents. Instruction Sheet

Setup. S&C IntelliCap 2000 Automatic Capacitor Control. Table of Contents. Instruction Sheet

Setup. S&C 5800 Series Automatic Switch Controls With IntelliTeam Automatic Restoration System. Table of Contents. Instruction Sheet

Table of Contents Section Page Section Page Introduction Safety Information Installation Diagrams Installation

StruxureWare Power Monitoring 7.0

Operation. S&C 6800 Series Automatic Switch Controls with IntelliTeam SG Automatic Restoration System. Table of Contents. Instruction Sheet

PowerLogic ION7550 RTU option

DX200 OPTIONS INSTRUCTIONS

Greco Systems. License Manager. Operation Manual OM A division of e-dnc Inc. 303 E Gurley St. #522 Prescott, AZ USA

Installation. Section Page Section Page NOTICE

DX200 OPTIONS INSTRUCTIONS

User Manual VDH-GK350A 2016 SEP V1.0

Installation. S&C SpeedNet SDR Software Defined Radio. Table of Contents NOTICE. Instruction Sheet

Troubleshooting. S&C 5800 Series Automatic Switch Control. Table of Contents. Instruction Sheet

Installation and Operation

Installation. Section Page Section Page NOTICE

Operation and Maintenance

Application Note (Revision NEW) Original Instructions EGCP-3 LS Using an EGCP-3 in a Single-Phase Zig Zag Generator Application

Conext EasyConfig Tool

Instruction Manual. Multilin TM 8 Series Retrofit Kit * A1* GE Grid Solutions LISTED

StruxureWare Power Monitoring Expert 8.0 Data Center Edition

Silex SD-320AN-03 Serial Server

MultiTech Router Commissioning for Com X 200/210/510

Change Report Colors and Logo

EnCell Battery Cell Monitor

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

PowerLogic ION7300 Series

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

5521 Potentiometer Analog Input Module

WinMarkpro v6 for the FH Marking Head Quick Start Guide

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

PowerMonitor 5000 Unit Catalog Number Upgrade

User Manual. TSDiag+ Part Number: Version: 5. Date: TSDiag

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

Tool Operating Manual

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

Conext CL-60 EasyConfig Tool

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

Event Notification Module

NDT Remote Control Library. User s Manual

Instruction Sheet Updating SmartPAC 2 Firmware

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

ControlLogix Redundancy Update and Module Replacement Guidelines

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

3700 SERIES USER MANUAL

PRM Synchronization Tool

Device Management Basic HART DTM 6.0 Installation

Generator Performance Guide 7EN /2015

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

Introduction to the Autologic Vehicle Diagnostic Tool

Chore-Tronics Mobile Server

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Power Manager for SmartStruxure Solution

VS Omni. Consumer How-To Guide. CTSG-VSO100a. Copyright 2018 Hayward Industries Inc.

CRA Wiz and Fair Lending Wiz. Installation Guide V6.9

DX200 OPTIONS INSTRUCTIONS

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

SCADAPack E ISaGRAF Quick Start Guide

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

SIMATIC. PCS 7 Web Option for OS (V8.2) Security information 1. Preface 2. Overview of the Web Option for OS 3. Additional documentation 4

Schneider Electric Floating License Manager

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

PowerMonitor 1000 Unit Catalog Number Upgrade

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Thermwood CNC Rental Features

SMVector Additional I/O Module Installation and Operation Manual

Fluke Calibration Software

Conext CL-60 Inverter Firmware Upgrade Process

Grid4 s SmartCOMM Hosted IP Complete. Auto Attendant User Guide

Transcription:

S&C 6800 Series Automatic Switch Controls IntelliLink Setup Software Table of Contents Section Page. Introduction Qualified Persons.... 2 Read this Instruction Sheet... 2 Retain this Instruction Sheet... 2 Proper Application... 2.. Safety Information Understanding Safety-Alert Messages.... 3 Following Safety Instructions... 3 Replacement Instructions and Labels... 3 Section Page Overview.... 4 Establishing a Serial or WiFi Connection.... 5. Firmware Upgrade Save Settings... 9 Firmware Update... 9 Firmware Reversion.... 12 August 4, 2014 S&C Electric Company Instruction Sheet 1045-571

Introduction Qualified Persons Ç WARNING The equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of overhead electric power distribution equipment along with the associated hazards. A qualified person is one who is trained and competent in: The skills and techniques necessary to distinguish exposed live parts from non-live parts of electrical equipment. The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the qualified person will be exposed. The proper use of the special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electrical equipment. These instructions are intended only for such qualified persons. They are not intended to be a substitute for adequate training and experience in safety procedures for this type of equipment. Read this Instruction Sheet Retain this Instruction Sheet Thoroughly and carefully read this instruction sheet before programming, operating, or maintaining your S&C 6800 Series Automatic Switch Control. Familiarize yourself with the safety information on page 3. The latest version of this instruction sheet is available online in PDF format at sandc.com/support/product-literature.asp This instruction sheet is a permanent part of your S&C 6800 Series Automatic Switch Control. Designate a location where you can easily retrieve and refer to this publication. Proper Application Ç CAUTION The equipment in this publication must be selected for a specific application. The application must be within the ratings furnished for the selected equipment. 2 S&C Instruction Sheet 1045-571

Safety Information Understanding Safety-Alert Messages There are several types of safety-alert messages which may appear throughout this instruction sheet as well as on labels attached to the S&C 6800 Series Automatic Switch Control. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below. Ç DANGER DANGER identifies the most serious and immediate hazards which will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç WARNING WARNING identifies hazards or unsafe practices which can result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç CAUTION CAUTION identifies hazards or unsafe practices which can result in minor personal injury or product or property damage if instructions, including recommended precautions, are not followed. NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed. Following Safety Instructions If you do not understand any portion of this instruction sheet and need assistance, contact your nearest S&C Sales Office or S&C Authorized Distributor. Their telephone numbers are listed on S&C s website sandc.com/salesdirectory/default.asp. Or call S&C Headquarters at (773) 338-1000; in Canada, call S&C Electric Canada Ltd. at (416) 249-9171. NOTICE Read this instruction sheet thoroughly and carefully before installing or operating your S&C 6800 Series Automatic Switch Control. Replacement Instructions and Labels If you need additional copies of this instruction sheet, contact your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. It is important that any missing, damaged, or faded labels on the equipment be replaced immediately. Replacement labels are available by contacting your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. S&C Instruction Sheet 1045-571 3

Overview 6800 Series Automatic Switch Controls shipping after March 31, 2013 will ship with 6800 Series Software 3.5.0 or above. This document covers serial and WiFi connection to the 6800 Series Automatic Switch Control s local user communication port. The software installer for 6800 Series Automatic Switch Controls is similar to the installers for IntelliRupter PulseCloser, and the IntelliNode Interface Module. The overview section in Instruction Sheet 766-571 Software Installation will provide useful information relative to 6800 Series software installer, as will the IntelliRupter Software Installer section. Follow the procedure described in the IntelliRupter Software Installer section for 6800 Automatic Switch Control software version 3.5.0 and higher. See the Computer Requirements section IntelliRupter Instruction Sheet 766-571 for computer requirements, and the IntelliLink Remote License Activation section in IntelliRupter Instructions Sheet 766-571 if you are an IntelliLink Remote Setup Software user. 4 S&C Instruction Sheet 1045-571

Establishing a Serial or WiFi Connection Select Start>All Programs>S&C Electric>IntelliLink. See Figure 1. Figure 1. Windows 7 Start Menu. Select Local Connection from the S&C Electric IntelliShell Select Connection Mode dialog box. See Figure 2. Figure 2. S&C Electric IntelliShell Select Connection Mode dialog box. S&C Instruction Sheet 1045-571 5

Establishing a Serial or WiFi Connection Select Series 6800 IntellTEAM II/SG form the S&C Electric IntelliShell Product Selection dialog and click the Serial button to make a serial connection, or WiFi to make a WiFi connection. See Figure 3. Figure 3. S&C Electric IntelliShell Product Selection dialog box. If you clicked the Serial button in the S&C Electric IntelliShell Local Communication Setup dialog: 1. Select the appropriate Comm Port for your computer. 2. Make sure the Timeout(ms) is 1000. 3. Select the Baud Rate. The default baud rate for an IntelliLink connection is 9600. If you have changed the baud rate setting and don t remember what it is, you can use the AUTO selection, and IntelliLink will try all the available baud rates to attempt to make a connection. 4. Click the IntelliLink button. See the Firmware Update section on page 9 if you want to do a firmware update. See Figure 4. Figure 4. S&C Electric IntelliShell Local Communication Setup dialog box. 6 S&C Instruction Sheet 1045-571

Establishing a Serial or WiFi Connection If you Selected the WiFi button in the LinkStart Dialog: 1. Use the Prev and Next button to fine the control serial number, or enter the control serial number in the Serial Number: field. 2. Click the Connect button. See Figure 5. Figure 5. LinkStart dialog box. The Ilink Loader dialog box will open followed by the S&C IntelliLink Login dialog box. See Figures 6 and Figure 7 on page 8. Enter your User Name and Password, and click OK. The default entries are User Name: admin, and Password: 1135Atlantic. If IntelliLink is unable to connect, the Ilink Loader will display Could not connect to device. See Figure 6. Check your connection and the settings above. Figure 6. Ilink Loader dialog box. S&C Instruction Sheet 1045-571 7

Establishing a Serial or WiFi Connection Figure 7. S&C IntelliLink Login dialog box. When the login has completed the main Operation screen opens. See Figure 8. Figure 8. 6801/2/3 Operation screen. 8 S&C Instruction Sheet 1045-571

Firmware Upgrade Save Settings NOTICE Upgrading firmware can result in a loss of settings. Always save your settings and save a snapshot file before upgrading firmware. To save your settings select File>Save Setpoints from the main menu bar. In the Save Setpoints dialog box click the Select All button followed by the browse button. See Figure 9. A file explorer will then open. Browse to the desired storage location, enter a name for the settings file and click the Save button on the browser dialog box. Figure 9. Save Setpoints dialog box. To save a snapshot, which is a copy of the control memory including logs, select File> Save Memory Snapshot. Firmware Update Start IntelliLink as described above and set the Comm Port, Baud Rate, Protocol, and Timeout as indicated above for the Serial connection. See Figure 10. Then click Update Firmware. Figure 10. S&C Electric IntelliSHELL Local Communication Setup dialog box. S&C Instruction Sheet 1045-571 9

Firmware Upgrade If you selected WiFi login, after the Operation screen opens, select Tools>Firmware Update from the main menu. See Figure 11. Figure 11. Tools>Firmware Update... menu option. Multiple Confirmation dialogs similar to the following may appear. See Figures 12 and 13. If they do, the recommendation is to select Yes. Figure 12. Confirmation dialog box with Upgrade Choice. Next a Confirmation dialog box will appear with a list of the software items to be downloaded. Select Yes to complete the upgrade, or No to exit. Figure 13. Confirmation dialog box with selected upgrade confirmation. 10 S&C Instruction Sheet 1045-571

Firmware Upgrade Next the Firmware Update dialog box will open to show the upgrade progress. After the update has completed, and the Script completed successfully message appears, click the Close button to finish. See Figure 14. Figure 14. Firmware Upgrade dialog box. S&C Instruction Sheet 1045-571 11

Firmware Reversion In some cases it may be necessary to revert to a previous version of 6800 Automatic Switch Control Firmware. Follow this procedure to change the firmware version. 1. Choose the required firmware revision, and obtain the software installer from the S&C Automation Customer Support Portal, if necessary. See Instruction Sheet 766-571 for more information about the Portal. 2. Click Start and select Control Panel, see Figure 15. Figure 15. Control Panel selection on the Windows 7 Start Menu. 12 S&C Instruction Sheet 1045-571

Firmware Reversion 3. From the Control Panel select Programs and Features, or for Windows XP select Add/Remove Programs, see Figure 16. Figure 16. Windows 7 Control Panel. 4. Remove all software revisions that are higher than the target revision. If there are multiple revisions work from the highest first to the lowest last. 5. If you already have IntelliLink6 installed, remove it. 6. Open Windows File Explorer and navigate to: C:\Program Files (x86)\s&c Electric\ Products\SG680xxx\Firmware\Upgrades (where: SG680xxx = the product to upgrade such as SG6801). 7. Delete any folders that have a version number higher than the target revision. See Figure 17. Figure 17. Indicated Firmware Upgrades in Windows File Explorer. S&C Instruction Sheet 1045-571 13

Firmware Reversion 8. Run the installer for the target version. If the target revision is already installed select the repair option, when it is presented by the installer. 9. Start IntelliLink (see Figure 1), and set the Comm Port, Baud Rate, Protocol, and Timeout (see Figure 4). Then click Update Firmware. 10. The Log On dialog opens, see Figure 18. Logon with your User Name and Password, or use the default: User Name: admin and Password: 1135Atlantic if you have not changed them. 11. After you logon click the Start Download button. Figure 18. S&C Download Utility. 14 S&C Instruction Sheet 1045-571

Firmware Reversion 12. Depending on the target version selected, the following S&C Control Software Loader dialog may appear, see Figure 19. If it does click No. Figure 19. S&C Control Software Loader dialog Exit? 13. Because the firmware in the control has higher versions of the software components, an S&C Control Software Loader dialog message, similar to Figure 20, will appear. If it asks to Skip this download? click the No button. Figure 20. S&C Control software Loader dialog Skip this download? S&C Instruction Sheet 1045-571 15

Firmware Reversion 14. When the download has completed, the S&C Control Software Loader dialog will open with the message Task completed. Exit? See Figure 21. Click the Yes button. Figure 21. S&C Control Software Loader dialog Exit? Printed in U.S.A. 16 S&C Instruction Sheet 1045-571