Introduction. Chapter 2

Similar documents
User s Manual June 2007

Quick Start Guide. January EAZ0081L02A Rev. A

Component Tests User Manual

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

Component Tests User Manual

OPERATING INSTRUCTION

Autoranging True RMS Multimeter User Manual

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

10A Micro-Ohmmeter Model 6240

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

The uscope Getting started

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

M12 Tool Holster

Circuit Breaker Analyzer & Timer CAT66

DX4085 Z-Meter Tester

Model A Mini AC/DC Clamp Meter. User's Guide

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Advanced Test Equipment Rentals ATEC (2832)

Manual Oscilloscope (Scope-Meter)

Circuit Breaker Analyzer & Timer CAT126

Kenai Peninsula Borough School District Formal Bid #

Circuit Breaker Analyzer & Timer CAT126

Refurbished 1U 19in Rackmount LCD Console with Integrated 8 Port KVM Switch

User Guide True RMS Multimeter Extech EX205T

A P P L I C A T I O N

Circuit Breaker Analyzer & Timer CAT-P

CBA 1000 CHARACTERISTICS

Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide

8 Port Rackmount USB VGA KVM Switch w/ Audio (Audio Cables Included) StarTech ID: SV831DUSBAU

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

Autoranging Mini Multimeter

Circuit Breaker Analyzer & Timer CAT-P

The SV431TDVIUA 4-Port Triple Monitor DVI KVM Switch is backed by a StarTech.com 3-year warranty and free lifetime technical support.

User Manual. August ZEESC310K Rev. A

CBA HV Circuit Breaker Analyzer and Microhmmeter

Sentinel AC & DC Current Logger Models SDL A401 & SDL A402

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Mini Digital Multimeter

Agilent 3630A Triple DC Power Supply. Agilent 34401A Digital Multimeter (DMM)

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

User's Guide. MiniTec TM Series Model MN25 MultiMeter

DP-PS Laboratory Diode Driver (For use with MK-11, 81, 82, 85, & 88 lasers)

Model R5010. TRMS Digital Multimeter. Instruction Manual

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT

HBAC-30. Owner s Manual. Battery powered Guitar Amp

The SV431TDVIUA 4-Port Triple Monitor DVI KVM Switch is backed by a StarTech.com 3-year warranty and free lifetime technical support.

power quality Models 8230 & 8220

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Sentinel Data Loggers

Mini Digital Multimeter

Circuit Breaker Analyzer & Timer CAT65

1519L Multifunction 15-inch Desktop Touchmonitor

INSTALLATION INSTRUCTIONS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MANUAL PCE-123

WL-21701/21708/21716 User Reference Manual. Revision 1.3 (080717)

The uscope Getting started

PIECAL 510B/511B RTD Simulator Operating Instructions

1. REMOTE SENSOR 2. A/V IN JACK 4. DC 12V IN 5. TFT-LCD SCREEN 6. EARPHONE JACK 7. SPEAKER 9. TV/AV BUTTON 13. ROD ANTENNA 14.

ARX 308 User Reference Manual

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

IST ULTRASTAB Power Supply for high precision transducers

Mini Digital Multimeter Model MN15. User's Guide

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Multifunction Calibrator

MEASURING AND TESTING INSTRUMENTS

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Portable Ground Control Station

INSTRUCTION and OPERATIONS MANUAL. for

CE700 Wireless Charging Stand FAQ:

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

MPC " Industrial Web Tablet with Windows CE

Circuit Breaker Analyzer & Timer CAT31

DRTS 33. The new generation of advanced three phase relay test set

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

B&W RearView Camera Installation & Operation

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

Holder, Speaker and Charger Functions (With Optional Cellular Phone Hands free capability) FEATURES...1

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

Blue Point Engineering

Three-Phase Power Quality Analyzer PowerPad Model 3945

Autoranging Multimeter Extech EX503

FG-7000 Digital Force Gauge Operation Manual

Transcription:

The Vantage PRO unit (Figure 2-1) combines a digital and graphing multimeter, lab scope and ignition scope with a powerful diagnostic database. Figure 2-1 Vantage PRO This diagnostic database gives you component-specific test information and automatically configures the tool for any selected test. A multi-window format lets you simultaneously view instrumentation readings and component-specific test help information. 5

2.1 Functional Description Figure 2-2 Vantage PRO unit front view A Transflective screen B N (No) and Y (Yes) buttons C Thumb Pad D Right handgrip E Brightness/Contrast button F S button G Power button H Left handgrip 6

Functional Description Figure 2-3 Vantage PRO unit top view A CompactFlash (CF) Card Slot 1 Master program CF card slot (no hot swapping). B CF Card Slot 2 Supports I/O hot swapping. C USB ports Protected by sliding shield. For printer, keyboard, mouse or PC computer. D Channel 1 (CH1, yellow) V/Ω/Diode/Hz/PW 1 /F-INJ PW Duty Cycle%, 200V max. E Common ground (COM, black) F Channel 2 (CH2, green) VDC, 200V max. G Amps (10A, blue) 32VDC max. H Aux Port DB9F connectors, such as the split lead adapter or the inductive rpm pickup. I DC power jack 1 PW stands for Pulse Width. 7

Figure 2-4 Vantage PRO unit back view A Stand B Casing hooks 2.2 The Stand The Vantage PRO unit has a built-in metal stand attached to the back. When the stand is not in use, it is secured to the back of the unit by integrated casing hooks. When extended, the stand allows the unit to rest at a 45 angle for hands-free viewing (Figure 2-5). 8

The Stand Figure 2-5 Vantage PRO unit with stand extended The stand can also be extended to a hanging position by pressing the left side towards the right and rotating forward (Figure 2-6). Figure 2-6 Vantage PRO unit with stand in hanging position 9

2.3 Technical Specifications Display: Transflective Liquid Crystal Display (LCD) Visible under any lighting condition 320 x 240 resolution (1/4 VGA) 256 colors 5.7 inches (144.8 mm) CompactFlash (CF) Card Slot: CF Type 1 Slot 1 is for the master program CF card Slot 2 is for user options, such as a storage CF card Battery Pack: Nickel-metal hydride Rechargeable External Battery Charger: Input: 100 240 V AC @ 0.5A, 47 63 Hz Fuse: 10 Amp ATO Mini AC/DC Adapter: 2.5 mm DC plug Input: 100 240V AC @ 0.5A, 47 63 Hz Output: 15V DC @ 1.2A 10

Operating Specifications Dimensions: Width: 11.75 inches (298.45 mm) Height: 6.90 inches (175.26 mm) Depth: 2.40 inches (60.96 mm) Weight (including battery pack): 3 lbs 12.5 oz (1.509 Kg) Operating Temperature Range: 32 to 122 F (0 to 50 C) Storage Temperature Range: 4 to 140 F ( 20 to 60 C) 2.4 Operating Specifications The following tables detail the Vantage PRO unit operating specifications for: Scope capabilities Test instrument capabilities 2.4.1 Scope Capabilities The following tables (Table 2-1 and Table 2-2) detail the Scope capabilities for: Analog to digital (A/D) conversions Horizontal sweep and frame storage 11

Table 2-1 Scope: Analog to digital conversions FUNCTION RANGE ACCURACY/COMMENTS Channels 2 Common grounds Sample Rate 8 msps Maximum Resolution 12 bits Table 2-2 Scope: Horizontal sweep and frame storage SWEEP 2 DATA POINTS PER CHANNEL BUFFER STORAGE PER CHANNEL 1 50 µs 200 1305 screens (262,000 data points) 1048 screens 100 µs 20 s 250 (262,000 data points) 1 Buffer storage consists of contiguous screens of 2 channel data. 2 A microsecond (µs) equals one millionth of a second. 2.4.2 Test Instrument Capabilities Test instrument capabilities are shown in the table below (Table 2-3). Table 2-3 Test Instrument capabilities (part 1 of 5) FUNCTION RANGE RESOLUTION ACCURACY 1 Amps (Internal) 1 A 0.001 A +(1.5% + 2 digits) 2 A 5 A 10 A 0.01 A +(1.0% + 2 digits) 1 Accuracy, measured at 25 C, is shown as ± (% of reading) + (Number of least significant digits). For example, accuracy reading a 100V DC signal would be ± (0.25% + 2 digits), or 99.75 to 100.25 ± 2 digits; or 99.73 to 100.27. 12

Operating Specifications Table 2-3 Test Instrument capabilities (part 2 of 5) FUNCTION RANGE RESOLUTION ACCURACY 1 Diode/ Continuity Duty-cycle Frequency Hz Frequency Hz (continued) 2.5 0.002 V +(1% + 2 digits) 20 40 60 80 100 5 1Hz 1500Hz: 0.1% 1501Hz 3000Hz: 0.2% 3001Hz 7500Hz: 0.5% 750Hz 15kHz: 1% 15001Hz 20kHz: 1.5% 1Hz 9kHz +(1%+ 2 digits) 9001Hz 20kHz +(2% + 2 digits) 10 0.01Hz +(0.25% + 2 50 digits) 100 0.1Hz 250 0.1Hz 500 1000 1Hz 2000 3Hz 5000 20Hz +(0.5% + 2 digits) 10000 100Hz +(1.5% + 2 digits) 20000 300Hz 50000 1800Hz +(3.5% + 2 digits) 1 Accuracy, measured at 25 C, is shown as ± (% of reading) + (Number of least significant digits). For example, accuracy reading a 100V DC signal would be ± (0.25% + 2 digits), or 99.75 to 100.25 ± 2 digits; or 99.73 to 100.27. 13

Table 2-3 Test Instrument capabilities (part 3 of 5) FUNCTION RANGE RESOLUTION ACCURACY 1 Ignition scope MC Dwell degrees 2000 3000 5000 10000 15000 2000 5000 20 40 60 5V 50V 0.1 +(0.5% + 2 digits) 40 0.05 400 1 Ohms 4k 10 +(1.5% + 2 digits) 40k 100 400k 1k 4M 10k +(2.0% + 2 digits) 0.005 s +(1.7% + 2 digits) 0.01s 0.01ms 0.025 s 0.05 s Pulse-Width 0.1 s +(0.1% + 2 digits) 0.25 s 0.1ms 0.5 s 2 s 1ms Rpm 2-cycle (inductive) 1 rpm +(0.3% + 2 digits) 1 Accuracy, measured at 25 C, is shown as ± (% of reading) + (Number of least significant digits). For example, accuracy reading a 100V DC signal would be ± (0.25% + 2 digits), or 99.75 to 100.25 ± 2 digits; or 99.73 to 100.27. 14

Operating Specifications Table 2-3 Test Instrument capabilities (part 4 of 5) FUNCTION RANGE RESOLUTION ACCURACY 1 Rpm 4-cycle (inductive) Secondary rpm Volts AC RMS Volts DC (Channel 1) 1 rpm +(0.3% + 2 digits) 1 rpm 10 rpm 0.1 0.1 mv 0.2 0.5 1 2 5 10 20 50 0.1 0.2 0.5 1 2 5 10 20 50 0.001 V 0.01 V 0.1 V 0.1 mv 0.001 V 0.01 V +(0.3% + 2 digits) +(1.5% + 4 digits) +(1.0% + 2 digits) 100 0.1 V 200 1 Accuracy, measured at 25 C, is shown as ± (% of reading) + (Number of least significant digits). For example, accuracy reading a 100V DC signal would be ± (0.25% + 2 digits), or 99.75 to 100.25 ± 2 digits; or 99.73 to 100.27. 15

Table 2-3 Test Instrument capabilities (part 5 of 5) FUNCTION RANGE RESOLUTION ACCURACY 1 Volts DC (Channel 2) 0.1 0.1 mv 0.2 0.1 mv 0.5 0.001 V 1 0.001 V 2 0.001 V 5 0.01 V 10 0.01 V 20 0.01 V 50 100 0.1 V 200 +(1.0% + 2 digits) Volts DC Transducer inputs 0.0025 V +(1.0% + 2 digits) 1 Accuracy, measured at 25 C, is shown as ± (% of reading) + (Number of least significant digits). For example, accuracy reading a 100V DC signal would be ± (0.25% + 2 digits), or 99.75 to 100.25 ± 2 digits; or 99.73 to 100.27. 16

Control Buttons 2.5 Control Buttons The Vantage PRO unit (Figure 2-2 on page 6) has the following control buttons: Y button N button Thumb Pad (c, e, b, d) Brightness/Contrast button S button Power button 2.5.1 Y (Yes) Button The Y button does the following: Selects the item you highlighted using the Thumb Pad. Toggles between cursors. 2.5.2 N (No) Button The N button does the following: Exits a menu or program. Moves the highlight between the upper and lower parts of the screen. 2.5.3 Thumb Pad The Thumb Pad (c, e, b, d) moves the highlight around the screen for making menu or field selections and is typically used in combination with the Y and N buttons. 17

2.5.4 Brightness/Contrast Button The Brightness/Contrast button lets you adjust the screen for optimum viewing. See Adjusting Brightness and Contrast on page 31 for details. 2.5.5 S Button The S button can be customized to perform different functions from the UTILITIES > Tool Setup menu. See S Button on page 140 for details. 2.5.6 Power Button The Power button powers the Vantage PRO unit on and off. The option to put the unit in Standby mode is also available. See Powering Off the Unit on page 34 for details. 2.6 Connections The Vantage PRO unit uses the following connections (Figure 2-3 on page 7): Test lead jacks DC power jack USB port 2.6.1 Test Lead Jacks Standard safety banana jacks are used with test leads. 18

Power Sources For related information, see the following sections: Leads and Clips on page 23 Connecting Leads and Clips on page 31 Accessories on page 153 2.6.2 DC Power Jack The DC power jack can be used to power the unit with the AC/DC power adapter. For related information, see the following sections: AC/DC Power Adapter on page 20 Connecting the AC/DC Power Adapter on page 28 Replacement Parts on page 154 2.6.3 USB Port The USB port can be used for connecting to a printer, keyboard or a PC. For related information, see the following sections: Setting Up to Print on page 33 Editing Saved Files on page 126 2.7 Power Sources Your Vantage PRO unit can receive power from the following sources: AC/DC power adapter Battery pack (rechargeable) Vehicle power adapters (optional) 19

2.7.1 AC/DC Power Adapter The Vantage PRO unit can be powered from a wall socket using the AC/DC power adapter (Figure 2-7). When both the AC/DC power adapter and the battery pack are installed, the AC/DC power adapter is the primary power source. Figure 2-7 AC/DC power adapter NOTE: i When connected to the Vantage PRO unit, the AC/DC power adapter will not charge an installed battery pack. See Battery Charger on page 21 for details. 2.7.2 Battery Pack The Vantage PRO unit can be powered by a rechargeable nickel-metal hydride battery pack installed at the bottom of the unit behind the right handgrip (Figure 2-8). 20

Power Sources Figure 2-8 Battery pack installation location 2.7.3 Battery Charger The battery pack is recharged by an external battery charger (Figure 2-9). Figure 2-9 Battery charger The Vantage PRO battery charger uses the same AC/DC power supply that can also be used to power the Vantage PRO unit. See AC/DC Power Adapter on page 20 for more details. 21

2.7.4 Vehicle Auxiliary Power Cables (Optional) The Vantage PRO unit can be powered from a vehicle using the optional Lighter Power Cable (EAX0051B03A) and the optional Battery Power Cable (EAX0051B04A) (Figure 2-10). Figure 2-10 Optional vehicle power adapters A Battery Power Cable (EAX0051B04A) B Lighter Power Cable (EAX0051B03A) NOTE: i If powering from a vehicle battery using the Battery Power Cable, the Lighter Power Cable is also required. See Accessories on page 153 for details on how to order. 22

Leads and Clips 2.8 Leads and Clips The Vantage PRO kit includes the following standard leads and clips: Channel 1 lead Channel 2 lead Alligator clips IMPORTANT: Pull on the connector to remove the leads from their jacks. Pulling on the wire can damage the leads. See Connecting Leads and Clips on page 31 for more details. 2.8.1 Channel 1 Lead The shielded yellow lead is used for Channel 1 (Figure 2-11). The lead color matches the color of the CH1 jack on the Vantage PRO unit and the trace color of Ch 1 on the test screens. A stackable, black right-angle ground plug is attached. Figure 2-11 Yellow Channel 1 Lead 2.8.2 Channel 2 Lead The shielded green lead is used for Channel 2 (Figure 2-12). The lead color matches the color of the CH2 jack on the Vantage PRO unit and the trace color of Ch 2 on the test screens. A stackable, black right-angle ground plug is attached. 23

Figure 2-12 Green Channel 2 Lead 2.8.3 Alligator Clips Three insulated alligator clips are included: one yellow and one green clip to match each test lead, and one black clip for the ground lead (Figure 2-13). Figure 2-13 Alligator Clip 24