WRI400 WIRELESS READER INTERFACE

Similar documents
PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

CT5000. Offline controller user guide Instructions for Adaptable Series offline controller _C LED2 USB USB SCHLAGE STRIKE RELAY STATUS +5V

Suprex RS-485 SPX-7500 Wired Reader-Extender

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

AD-300 AD-301. Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks

AD-300 AD-301. Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks

SPX-7400_SPX-7410_MAN_161028

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

PXL-250 Tiger Controller

Digital Keypad Introduction

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

6222 Two Door Module Technical Operations Manual

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

AD-400 AD-401. Networked wireless lock user guide Instructions for adaptable series networked wireless locks

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Quick Start Installation Guide

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

Quick Start Installation Guide

AD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE

KP2000E/EM Series Style Keypad

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Access control panel U-Prox IC E (Elevator control)

DOLXFD1000B. Waterproof Access Control/Reader

2000 Series e/em Style Keypad Installation and Programming Manual

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices

AD-400 AD-401. Networked wireless lock user guide Instructions for adaptable series networked wireless locks

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

UC-2000 Installation Manual Unicorn Computers Technology Limited

SPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112

IPassan Installation guide

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

NetAXS. Cloud-Hosted Services. Cloud Hosted Access Control. Retail Property Management Franchises

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

User Manual. PCKeypad Wireless Keypad

Two Door Controller GEN-045

EL-ST100 KEYPAD CONTROLLER

Pyramid Series Proximity Readers

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Click Save to return to the main Setup screen.

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

TruPortal Dual Door Interface Module Quick Reference

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Stand-alone Proximity Access Control

Installation Instructions

MR51e Reader Interface

GV-AS Controller. Installation Guide

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

Key Switch. Document version: 1.5 (Updated 02 May 2017)

GV-AS/EV Controller. User s Manual

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Connecting a Cisco Input Module

IEI emerge MicroNode Install and Setup Guide. Contents

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

AS Keypad User Manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

NetAXS. Hosted Video Services. Cloud Hosted Access Control. Retail Professional Services Convenience

-DTZ001- Stand-Alone Proximity Access Control. User Manual

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

Single Door Standalone Access Control User Manual

RBR-SB-KTZ001 LAR 2. User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

VIDI-AC-2CS Access Controller/ Reader

ACTsmart2 Product Range Operating and Installation Instructions

Specifications: Features:

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

ACS5000 Panel (A/E/S) Installation Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Waterproof. Keypad/Reader/Controller

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

U-FLASH Setup Guide U-FLASH.

CA-A480-A Elevator Controller. Reference & Installation Manual

istar Pro Installation Guide

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Connecting a Cisco Output Module

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

A list of distributors can be found on our website at -

DESIGN GUIDE FOR INFINITY SYSTEMS

Installation Instructions (KF-2000)

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Camden - Key Switches

ACTpro Single Door IP Controller. Operating & Installation Instructions

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

How to Install a PowerNet IPBridge

Transcription:

WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1

Training Overview WRI400 Description Information Installation Comparison to Legacy WRI SUS/HHD Ah-Ha s

WRI400 installed in Systems; AD Series Wireless Technology and access features to openings Door Opening Elevators Gate March 12 Technical Services Engineering Support 3

WRI400 Description The Schlage WRI400 is an ON-LINE wireless interface module with AD- Series technology The WRI400 can configure any opening with equivalent AD400 features Using industry portal devices; credential readers, strikes, DPS, RTX and RTE switches The WRI400 Wirelessly Interfaces readers and access control devices to a PIM400 Link and assign the WRI400 like a AD400 for AD-Series features Assign as a Legacy (PIM-485 and WRI) for Legacy features (See later page) The WRI400 is for major Openings, decorative Openings, dual door Openings, Openings using magnetic-lock, electric strikes The WRI400 will also be in an Elevator and Gate Access kit, see user manual The SUS/HHD connects with the WRI400 USB for firmware updates, to view or edit Lock Properties like an AD400 The WRI400 uses the same main Printed Circuit board and enclosure as the CT5000. They can be re-classed with Firmware (Remember the LID Label) March 12 Technical Services Engineering Support 4

WRI400 Description The WRI400 can be used with up to two (2) credential readers that have Wiegand or Clock and Data outputs (wave58171) Left-side/right-side readers, ADA reader and mullion reader, Gates, and Elevators NOTE ; Both readers are the same Opening, they have the same identical access rights WRI400 Supports three optional status inputs:, Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) Reader 1 Tamper and Reader 2 Tamper are reported by the WRI400; but not indentified by Access Control Panels yet - Will call Tamper1/2 Lock Clutch Engaged or Dead bolt or Latch bolt Engaged Supports TWO (2) Form C, dry contact relays outputs, Strike - Electric Strike, magnetic lock, Auxiliary ADA door opener (Automatic operator) CONTROLED BY ACCESS CONTROL PANEL

WRI400 Description The Alarm relay Is not used by the WRI400 firmware The WRI400 has no Buzz-in reporting feature Buzz-in switches can be wired across the STRIKE relay output The WRI400 is a powered device and must have +12 or +24 volt power, No AA battery operation for the WRI400, relay control requires more power than batteries No coin cell is needed or used by the WRI400, (Like the AD400) wave58154 Coin Cell batteries are not shipped in the WRI400 The PCB silk screen says COIN CELL NOT NEEDED IF RADIO BOARD PRESENT The WRI400 needs a UL294 Listed Class 2 power supply, not included. (example: Schlage models PS902, PS904, and PS906) Note: The WRI400 will not power the readers wave57830 When sharing the power supply you must get the polarities correct, and select a supply which is compatible with the reader and the WRI400. The WRI400 requires 12volt 500ma; and READERS are typically 12VDC to 5VDC 200 ma each

Assigning BrightBlue Templates BrightBlue will be updated late this fall to include WRI400 assignment templates. Below Work Around With BrightBlue as it is now; AD-Series, Assign the WRI400 as an AD400 Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) NO AUX function, (NO ALRAM function) Assign as a Legacy, Assign a PIM400 using a BB Legacy Template WRI400 as a Legacy WRI This PIM400 can now only link to a device on a Legacy Template, it can not be shared with AD400 locks) LINK the PIM400 and the WRI400 and they now report like a Legacy WRI with AUX operations

WRI400 in a System March 12 Technical Services Engineering Support 8

WRI400 User Interface Green LEDs RED Buttons Brown Relay Status LEDs Blue Jumper March 12 Technical Services Engineering Support 9

WRI400 Information www.schlage.com/support User guides - P516-100 Data Sheets Technical Bulletins Firmware down loads Knowledge Center for technical questions RADAR Reporting Siebel SR reports with actions into Test Track Pro March 12 Technical Services Engineering Support 10

Agency UL ratings Suitable for outdoor use, ambient temperature range -35C to +66C (-31F to +151F) and weather tight NEMA enclosure when using a NEMA gland The WRI400 is listed under UL294 as an access control system subassembly UL listed panic hardware must be used to allow emergency exit from the protected area The WRI400 has not been evaluated to UL325 or UL508, UL325/508 are automation standards March 12 UL 325 is a safety standard for door, drapery, gate, louver, and window operators and systems. Specifically, it applies to electric operators for doors, draperies, gates, louvers, windows and other opening and closing appliances rated 600 volts or less. UL 508 is a standard for Industrial Control Equipment. Technical Services Engineering Support 11

PIM400 and WRI400 Installation Location WRI400 mounting location is similar to the AD Series for RF communication to the PIM400 Secured side of the access portal The maximum RF distance indoors between a PIM400 and a WRI400 is 200 feet (61 meters) Same floor in a building normal construction materials The maximum distance for a line-of-sight installation is 1000 feet (305 meters) March 12 Technical Services Engineering Support 12

PIM400 and WRI400 Installation Location WRI400 can use the ANT400 antenna kits for increased RF communication range Use of high-gain antenna (ANT400-REM I/O +6DB) will improve range The antenna KIT includes a 15 foot cable (4.5 meters) Don t exceed this cable length Do not locate the WRI400 and remote antenna, or the PIM400 (and its remote antenna, if used) on separate floors within a building (However having both antennas on the same floor is OK) Mounting a WRI400 is just like a PIM400 Vertically with the radio board at the top of the enclosure If on a metallic surface, stand the WRI400 off 1 inch (25 mm) from the metal 13

WRI400 Installation Wiring Portal Inputs; Status Monitors RTE, RTX, and DPS expect dry contact inputs switched to Ground when the switch is closed and the signal is ACTIVE Reader 1 Tamper and Reader 2 Tamper expect dry contact switches tied to Ground when the switch is closed, OR a signal level input for 5V logic Don t exceed 5V it will cause damage Connect the shield of the portal input cables to the appropriate WRI400 GND terminal see User Guide To ensure proper integration with the ACP, the input logic may be changed from the default condition using the Schlage Utility Software (SUS) on the HHD 14

Credential Readers Inputs READER inputs; Auto-Detect Wiegand (D1/D0) Magnetic (Clock and Data) -Two separate credential reader interface headers, J17 & J18 -Reader input ports are designed for 5V logic (Typical) - Don t exceed 5VDC -The most extensive testing was with; -Essex Electronics model KTP-162 (Keypad) -Schlage SMR-5 & SMR-20 -Mercury Security MR-5 & MR-20 (Mag Stripe) - Schlage SXF-1050 & SXF-150 (Prox) - SXF-1100, SXF-1500, SXF-2100, SXF-2110 (Multi-Tech) March 12 Technical Services Engineering Support 15

WRI400 control of the READER - Beeper, Green LED, RED LED! The WRI400 does not provide power to the readers! The WRI400 will use the reader beeper with a FDR. -Please consult with the reader s manufacturer for reader configuration, readers typically beep with a card present. - Reader beeper and LED controls are configured by the reader factory per order. Configuration can sometimes be changed in the field using a "Configuration Card" from the reader manufacturer -Example: If the reader is ordered with RED LED always ON (Indicating power at the READER), the WRI400 can not turn the RED LED off

Portal Outputs, to the Door Strike & AUX Outputs are Form C relays; C, NO, NC Transient suppression per the Load Ratings are in the User Guide, Strike - 6A @ 24VDC, 3a @ 240vac AUX 2A @ 24VDC, 0.5a @ 120vac March 12 Technical Services Engineering Support 17

RF PCB; The WRI400 uses the same COM400 board as the PIM400 - It has a MCX/SMB jack for the optional antenna kit The MCX Jack is the only difference between the AD400 to WRI400/PIM400 COM400 - COM400 FW 2.2a and 2.2d are compatible everywhere 18

LEGACY PRODUCTS WRI400 AD SERIES Reader Interface Times Two Two Readers, same Door file Two Readers same door file Two readers Wired in Parallel CLK/D1 DATA/D0 12VDC+ GND GRN_LED RED_LED n/a READER_TAMPER Two Reader Connectors J17 & J18 CLK/D1 DATA/D0 n/a Reader powered separately GND GRN_LED RED_LED BEEPER (Two) READER_TAMPER (subject to ACP interpretation) March 12 Technical Services Engineering Support 19

LEGACY PRODUCTS CREDENTIALS PIN only Credential + PIN Prox/Mag Cards Smart Cards not supported WRI400 AD SERIES ONLY with Card Emulation using a 26-bit keypad (Special order READER Configuration) ONLY if the keypad is 8-bit format (typical READER/Keypad) Prox/Mag Cards (AD Series) Smart Cards (AD Series) Power, Supply must be UL 294 Listed 12 VDC @300 ma + READER Legacy WRI has a reader power jack 12 or 24 Volt DC @500 ma No coin cell battery is needed/used No READER Power output - If using a 24 volt power supply, Do not over voltage the reader. Check the reader voltage requirements March 12 Technical Services Engineering Support 20

LEGACY PRODUCTS WRI400 AD SERIES Legacy PIM PIM400 - AD-Series (TD2 & 485) 200' Horizontally through walls 200 Horizontally through walls 1000' line-of-sight 1000' line-of-sight ANT-REM Gate Elevator ANT 400 (Ceiling, HALL & I/O+6dB) Gate Kit - GCK400 (WRI400 Out Door, PIM400- TD2, PIM Power Supply, and ANT400-REM-I/O) Mid-June 2011 ordering Elevator Kit - ECK400 (WRI400, PIM400-TD2, PIM Power Supply, and ANT400-REM-Ceiling) Mid-June 2011 ordering March 12 Technical Services Engineering Support 21

Legacy WRI and WRI400 Wire Same Type, part number, Same Maximum Lengths (User Guide) March 12 Technical Services Engineering Support 22

LEGACY PRODUCTS WRI400 AD SERIES Specifications FCC Part 15, Class B, FCC Part 15, Class B UL 294 UL 294-31 F to +151 F -31 F to +151 F Plastic Enclosure Outdoor option Plastic Enclosure, and larger than a WRI Legacy Weather Tight March 12 Technical Services Engineering Support 23

WRI400 Set-Up HHD Connection Automatic - HHD Diagnostics from the PIM400 for RTE, RTX, DPS and Lid Tamper (ala AD400) In the User Guide and the Lid Label HHD COUPLING - Hold the WRI400 SCHLAGE Button, hit the WRI400 LINK three times CONSTRUCTION - Hold the WRI400 SCHLAGE button and present the card to be Master Construction Credntial, use the Master Construction to enroll construction user access cards LINKING - Press the WRI400 LINK button for 3 seconds (Always do the PIM400 first) FDR - Hold the WRI400 Schlage & LINK for 3 seconds TEST - Hold the WRI400 SCHLAGE and press RESET button, after re-boot, all LED & RELAY change state and the end of the reset re-boot. March 12 Technical Services Engineering Support 24

WRI400 AD SERIES LINKING LINK to PIM400-485/TD2 Door number assignment LINKING to a PIM400 - HHD assigns door number when LINKING to a PIM400-485, 0-15 - LINK 0 or LINK 1 manually when LINKING to a PIM400-TD2 Just like an AD400 March 12 Technical Services Engineering Support 25

SUS Settings for the WRI400 SUS 4.3.1 HHD Screens for the WRI400 March 12 Technical Services Engineering Support 26

March 12 Technical Services Engineering Support 27

March 12 Technical Services Engineering Support 28

March 12 Technical Services Engineering Support 29

March 12 Technical Services Engineering Support 30

SUS 4.3.1 HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 31

SUS 4.3.1 HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 32

SUS 4.3.1 HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 33

SUS 4.3.1 HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 34

WRI400 Lid Label, and in the User Guide LED blinks, LINK, FDR, Coupling, Construction mode and Test March 12 Technical Services Engineering Support Confidential 35

USER GUIDE March 12 Technical Services Engineering Support Confidential 36

User Guide March 12 Technical Services Engineering Support Confidential 37

WRI400 Ah-Ha s Review No power is provided to the READERS (wave57830) Using Bright Blue or an OEM Access Control Panel Add the WRI400 just like the AD400 Or Add as a Legacy WRI, using a Legacy configured PIM400 SMS & BrightBlue update schedule for fall 2011 WRI400 has no integrated BUZZ-in feature. Just wire the Buzz-in switch across the WRI400 strike relay output. Might get a Forced Door WRI400 has no ALARM feature, alarm relay is not controlled by the WRI400 firmware. You must use the ACP to control the AUX for an alarm function. READER LED & BEEPER control are dependent on the as-ordered READER. The WRI400 can not completely control READER LED and BEEPER 100%. March 12 Technical Services Engineering Support 38