LED light engines LED flexible

Similar documents
LED light engines LED flexible

PHASED OUT. LED light engine / OLED LED flexible. Module LLE-FLEX Modules LLE FLEX ADVANCED

LED light engines LED flexible

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

AC modules LED compact

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

AC modules LED linear / area. Engine LLE AC G1 24mm SNC Module LLE ESSENCE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G1 24mm ADV-SE Modules LLE ADVANCED

PHASED OUT. LED light engines ready2apply. Engine SLA ready2apply phase-cut SNC Engine SLA ESSENCE

LED light engines ready2apply

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE. uengine STARK DLE PREMIUM system

LED light engine / OLED LED compact

) Forward voltage (V f. Typ. Max. Typ. [V] [V]

LX-562A. Linear LED Module, LX Series. 450 ma, 62.7 V. Electrical specifications. Lifetime specifications. Operating Conditions and Characteristics

L-iC-282. Tunable White Linear LED Module, L-iC Series. 450 ma, 14.9 V. Electrical specifications. Lifetime specifications

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

LED Driver Constant voltage. Driver LC 35W 24V SC SNC essence series

LINEAR LED BUILT-IN MODULES

LINEARLIGHT FLEX ADVANCED LF06A TECHNICAL DATASHEET

LEDLINE FLEX SMD INDOOR

LED LINE SMD LIGHTBAR

LED LIGHT PANEL QUADRANT SMD

LED Driver Compact fixed output

LED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series

ALULED IP66/IP V System WHITE, BLUE AND RGB LED MODULES IN FLAT ALUMINIUM PROFILE ALULED IP66/IP67

MERAKI LED MODULES. 5Years ECO 250X20 - LINEAL CV 12V (250X20MM) >100 I M P R O V I N G T E C H N O L O G Y

LED Driver Compact fixed output

LED INDUSTRY KIT. LED Industry Kit LED Modules for Industry Lighting WU-M-564 LED INDUSTRY KIT WU-M-564

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-542-G (270X540) LED MODULES FOR OFFICE LIGHTING WU-M-542-G

LED LINEAR ALLROUND GEN. 3

LED Driver Compact fixed output

LED Driver Compact fixed output

No. of. Voltage. Power

LED LINE SMD SLIM GEN. 2

SYM I AND SYM II. LED Industry and Hall Lighting LED LightEngine IP66 LED LIGHTENGINE IP66 LED INDUSTRY AND HALL LIGHTING WU-M-496-C

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED Driver Linear / area dimming

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-520 (250X250) WU-M-537 (270X270) LED MODULES FOR OFFICE LIGHTING

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

SHOP Line. Displays for the retail trade. Canopy and shelf lighting. Counter lighting. QCS Quick-Connection-System. Pasta & Cheese.

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LINEAR LED BUILT-IN MODULES

net4more IP connected lighting system net4more Driver net4more driver DC 30W mA un:c LED Driver for net4more systems

LED Driver Linear / area fixed output

LED LINE SMD KIT GEN. 3

LED MODULES. LUGA Shop Gen. 5 DMS128 Food LUGA SHOP GEN. 5 DMS128 SPECIAL COLOUR FOOD LUGA SHOP GEN. 5 DMS128. Typical Applications

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED LINE SMD KIT 3R GEN. 3

Duris E5 PowerFlex LED Strips 25mm LED Pitch

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

LED LINE SMD EASY L28/56 W2

LED Driver Linear / area fixed output

LED modules Module ELA For panel luminaires in system ceilings

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

Input Voltage [Vac] NominalP ower [W]

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED LINE SMD EASY L14/28/56 W2

LED LINE SMD KIT 3R CSP TUNEABLE

LED Driver Compact fixed output

LED FlatPanel Gen. 2 DALI

LED LINE CSP TUNEABLE

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

148 Photo: Photowalas

LED MODULES FOR MAINS VOLTAGE

LED Driver DC-String

LED MODULES FOR MAINS VOLTAGE

LED LIGHT PANEL SMD. TriplePowerEmitter XP TRIPLE POWER EMITTER XP WU-M-422

basicdim Wireless Wireless module for basicdim

VarioLED Flex AMOR IP67

LFP200C -G3-RGB-06. Product datasheet. LINEARlight Colormix Flex Protect Flexible colored / color change LED modules

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Linear / area dimming

LED Driver DC-String

VALUE Flex Protect 1200S

Transcription:

Module LLE FLEX G1 8mm SNC Modules LLE FLEX ESSENCE Product description Dimmable 24 V constant voltage strip (SELV) Ideal for various decorative lighting applications: facade accent lighting, ceiling integration, cove lighting and for aluminium extrusions Features and benefits Luminous flux range of 600, 1,200 and 1,800 lm/m Colour temperature 2,700, 3,000, 4,000 and 6,500 K with SDCM 5 3 Efficacy of the module up to 125 lm/w at tp = 65 C High design freedom due to 5 cm cut-options Pitch distance of 8.3 mm enables high light homogeneity Self-adhesive 3M tape at the backside for simple mounting on different surfaces PCB to PCB and wire to PCB connectors for toolless handling and connection Long life-time up to 50,000 hours 5-year guarantee System solution in combination with Tridonic constant voltage LED Driver (fixed output and dimmable) È Standards, page 4 Colour temperatures and tolerances, page 6 www.tridonic.com 1

Module LLE FLEX G1 8mm SNC Modules LLE FLEX ESSENCE Technical data Beam characteristic 120 Ambient temperature range -25... +45 C tp rated 65 C tc 75 C DC supply voltage 24 V DC supply voltage range 2 21.5 26.4 V Insulation test voltage 0.5 kv ESD classification severity level 4 Risk group (EN 62471:2008) 1 of protection IP00 Ordering data 50 4800 50...Cutting line for use with ACL plug connector tc...cutting line for solder connection Article number Colour Packaging temperature carton 8 Weight per roll LLE FLEX G1 8x4800 5W-600lm/m 827 SNC 28002098 2,700 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 5W-600lm/m 830 SNC 28002099 3,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 5W-600lm/m 840 SNC 28002 4,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 5W-600lm/m 865 SNC 28002101 6,500 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC 28002102 2,700 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC 28002103 3,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC 28002104 4,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC 28002105 6,500 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC 28002106 2,700 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC 28002107 3,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC 28002108 4,000 K 15 pc(s). 0.055 kg LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC 28002109 6,500 K 15 pc(s). 0.055 kg Specific technical data 5 Photometric Typ. luminous flux Typ. luminous flux code at tp = 25 C 1 at tp = 65 C 1 Typ. current consumption at tp = 65 C 1 Typ. power consumption at tp = 65 C 1 Efficacy of the module at tp = 25 C Efficacy of the module at tp = 65 C Colour rendering index CRI LLE FLEX G1 8x4800 5W-600lm/m 827 SNC 827/579 600 lm/m 585 lm/m 214 ma/m 5.2 W/m 120 lm/w 113 lm/w > 80 LLE FLEX G1 8x4800 5W-600lm/m 830 SNC 830/579 600 lm/m 585 lm/m 204 ma/m 5.0 W/m 130 lm/w 117 lm/w > 80 LLE FLEX G1 8x4800 5W-600lm/m 840 SNC 840/579 600 lm/m 585 lm/m 200 ma/m 4.8 W/m 130 lm/w 122 lm/w > 80 LLE FLEX G1 8x4800 5W-600lm/m 865 SNC 865/579 600 lm/m 585 lm/m 200 ma/m 4.8 W/m 130 lm/w 122 lm/w > 80 LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC 827/579 1,200 lm/m 1,175 lm/m 442 ma/m 10.6 W/m 118 lm/w 111 lm/w > 80 LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC 830/579 1,200 lm/m 1,175 lm/m 434 ma/m 10.4 W/m 122 lm/w 113 lm/w > 80 LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC 840/579 1,200 lm/m 1,175 lm/m 396 ma/m 9.8 W/m 133 lm/w 125 lm/w > 80 LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC 865/579 1,200 lm/m 1,175 lm/m 396 ma/m 9.8 W/m 133 lm/w 125 lm/w > 80 LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC 827/579 1,800 lm/m 1,765 lm/m 674 ma/m 16.2 W/m 117 lm/w 109 lm/w > 80 LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC 830/579 1,800 lm/m 1,765 lm/m 658 ma/m 15.8 W/m 120 lm/w 112 lm/w > 80 LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC 840/579 1,800 lm/m 1,765 lm/m 594 ma/m 14.2 W/m 132 lm/w 124 lm/w > 80 LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC 865/579 1,800 lm/m 1,765 lm/m 594 ma/m 14.2 W/m 132 lm/w 124 lm/w > 80 1 Tolerance range for optical and electrical data: ±20 %. Values given for 1 m LLE FLEX. 2 Exceeding the max. operating voltage leads to an overload on the LLE FLEX. This may in turn result in a reduction in life-time or even in destruction. 3 Integral measurement over the complete module. www.tridonic.com 2

ACCES- SORIES Connector for LLE FLEX Product description For connection of LLE FLEX modules Easy assembly: remove adhesive 3M tape on the backside of the LLE FLEX in the connection area, insert the LLE FLEX into the connector and lock it by pressing down the top of the connector The insertion length of the LLE FLEX must be at least 4 mm (cut the LLE FLEX at the dotted lines) Glow wire test according to IEC 60695-2-11: 650 C Irated = 5 A Urated = 29.9 V Wire cross section AWG 22 ACL plug connector Wire to PCB ACL plug connector PCB to PCB ACL plug corner connector 300/500/2000 9,8 4,8 5,7 8 9,2 4,2 0,425 ACL plug connector Wire to PCB 9,2 8,2 ACL plug connector PCB to PCB 9,2 5,7 9,2 5,7 9,8 150 9,8 ACL plug corner connector 150x9,8x5,7mm 9,8 60 9,8 ACL plug corner connector 60x9,8x5,7mm Ordering data Article number Cable length Packaging carton Packaging bag Weight per pc. ACL plug connector Wire to PCB 9x4.2mm 28000994 300 mm 250 pc(s). 10 pc(s). 0.004 kg ACL plug connector Wire-PCB 500x9x5.7mm 28001657 500 mm 20 pc(s). 0.008 kg ACL plug connector Wire-PCB 2000x9x5.7mm 28001656 2,000 mm 10 pc(s). 0.018 kg ACL plug connector PCB to PCB 8x4.2mm 28000995 25 pc(s). 25 pc(s). 0.001 kg ACL plug corner connector 150x9.8x5.7mm 28001654 10 pc(s). 0.002 kg ACL plug corner connector 60x9.8x5.7mm 28001655 20 pc(s). 0.002 kg www.tridonic.com 3

LED Driver matrix Dimmable LLE FLEX G1 8mm SNC Article number LLE FLEX UL certificated LCA 35W 24V one4all SC PRE LCA 60W 24V one4all SC PRE LCA W 24V one4all SC PRE LCA W 24V one4all lp PRE LCA W 24V one4all SC PRE 28001662 28001663 28001253 28001436 28001437 class 2 class 2 no no no Assignable LED Driver LLE FLEX G1 8x4800 5W-600lm/m 827 SNC 75 640 cm 125 1,105 cm 210 1,845 cm 210 1,845 cm 310 2,765 cm LLE FLEX G1 8x4800 5W-600lm/m 830 SNC 80 675 cm 130 1,160 cm 220 1,935 cm 220 1,935 cm 325 2,905 cm LLE FLEX G1 8x4800 5W-600lm/m 840 SNC 80 685 cm 135 1,185 cm 225 1,975 cm 225 1,975 cm 335 2,960 cm LLE FLEX G1 8x4800 5W-600lm/m 865 SNC 80 685 cm 135 1,185 cm 225 1,975 cm 225 1,975 cm 335 2,960 cm LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC 35 310 cm 60 535 cm 890 cm 890 cm 150 1,340 cm LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC 40 315 cm 65 545 cm 105 910 cm 105 910 cm 155 1,365 cm LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC 40 345 cm 70 595 cm 115 995 cm 115 995 cm 170 1,495 cm LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC 40 345 cm 70 595 cm 115 995 cm 115 995 cm 170 1,495 cm LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC 25 200 cm 40 350 cm 70 585 cm 70 585 cm 875 cm LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC 25 205 cm 45 360 cm 70 600 cm 70 600 cm 105 900 cm LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC 30 230 cm 45 395 cm 75 665 cm 75 665 cm 115 995 cm LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC 30 230 cm 45 395 cm 75 665 cm 75 665 cm 115 995 cm LED Driver matrix Fixed output TOP LLE FLEX G1 8mm SNC LCU 35W 24V TOP SR LCU 60W 24V TOP SR LCU 96W 24V TOP SR LCU 180W 24V TOP SR Article number LLE FLEX UL certificated 28000411 28000412 28000413 28000414 class 2 class 2 class 2 no Assignable LED Driver LLE FLEX G1 8x4800 5W-600lm/m 827 SNC 75 640 cm 95 1,095 cm 190 1,750 cm 355 3,285 cm LLE FLEX G1 8x4800 5W-600lm/m 830 SNC 75 670 cm 1,150 cm 200 1,840 cm 370 3,455 cm LLE FLEX G1 8x4800 5W-600lm/m 840 SNC 75 685 cm 1,170 cm 200 1,875 cm 375 3,520 cm LLE FLEX G1 8x4800 5W-600lm/m 865 SNC 75 685 cm 1,170 cm 200 1,875 cm 375 3,520 cm LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC 35 305 cm 50 530 cm 95 845 cm 170 1,590 cm LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC 35 315 cm 50 540 cm 95 865 cm 175 1,625 cm LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC 40 345 cm 55 590 cm 105 950 cm 190 1,780 cm LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC 40 345 cm 55 590 cm 105 950 cm 190 1,780 cm LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC 25 200 cm 30 345 cm 60 555 cm 115 1,040 cm LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC 25 205 cm 35 355 cm 65 570 cm 115 1,065 cm LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC 30 230 cm 35 390 cm 70 630 cm 130 1,180 cm LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC 30 230 cm 35 390 cm 70 630 cm 130 1,180 cm www.tridonic.com 4

LED Driver matrix Fixed output SNC LLE FLEX G1 8mm SNC LC 60W 24V SC SNC LC 60W 24V lp SNC LC W 24V SC SNC LC W 24V lp SNC Article number LLE FLEX UL certificated 87500665 87500669 87500666 87500670 class 2 class 2 no no Assignable LED Driver LLE FLEX G1 8x4800 5W-600lm/m 827 SNC 370 1,105 cm 370 1,105 cm 620 1,845 cm 620 1,845 cm LLE FLEX G1 8x4800 5W-600lm/m 830 SNC 390 1,160 cm 390 1,160 cm 650 1,935 cm 650 1,935 cn LLE FLEX G1 8x4800 5W-600lm/m 840 SNC 400 1,185 cm 400 1,185 cm 665 1,975 cm 665 1,975 cm LLE FLEX G1 8x4800 5W-600lm/m 865 SNC 400 1,185 cm 400 1,185 cm 665 1,975 cm 665 1,975 cm LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC 180 535 cm 180 535 cm 300 890 cm 300 890 cm LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC 185 545 cm 185 545 cm 305 910 cm 305 910 cm LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC 205 595 cm 205 595 cm 335 995 cm 335 995 cm LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC 205 595 cm 205 595 cm 335 995 cm 335 995 cm LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC 120 350 cm 120 350 cm 200 585 cm 200 585 cm LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC 125 360 cm 125 360 cm 205 600 cm 205 600 cm LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC 135 395 cm 135 395 cm 225 665 cm 225 665 cm LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC 135 395 cm 135 395 cm 225 665 cm 225 665 cm www.tridonic.com 5

1. Standards IEC 62031 IEC 62471 IEC 62778 IEC 61547 IEC 60-4-2 1.1 Photometric code Key for photometric code, e. g. 830 / 349 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Luminous flux after 25% Code CRI McAdam after of the life-time (max.6000h) Colour McAdam 25% of the Code Luminous flux temperature in 7 70 79 initial life-time 7 70 % Kelvin x 8 80 89 (max.6000h) 8 80 % 9 90 9 90 % 1.2 Energy classification Energy classification LLE FLEX G1 8x4800 5W-600lm/m 827 SNC A+ LLE FLEX G1 8x4800 5W-600lm/m 830 SNC A+ LLE FLEX G1 8x4800 5W-600lm/m 840 SNC A++ LLE FLEX G1 8x4800 5W-600lm/m 865 SNC A++ LLE FLEX G1 8x4800 11W-1200lm/m 827 SNC A+ LLE FLEX G1 8x4800 10W-1200lm/m 830 SNC A+ LLE FLEX G1 8x4800 10W-1200lm/m 840 SNC A+ LLE FLEX G1 8x4800 10W-1200lm/m 865 SNC A+ LLE FLEX G1 8x4800 16W-1800lm/m 827 SNC A+ LLE FLEX G1 8x4800 16W-1800lm/m 830 SNC A+ LLE FLEX G1 8x4800 14W-1800lm/m 840 SNC A+ LLE FLEX G1 8x4800 14W-1800lm/m 865 SNC A+ 2. Thermal details 2.1 tc point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a LED product. For LLE a tp temperature of 65 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. The tc and tp temperature of LED modules from Tridonic are measured at the same reference point. 2.4 Heat sink values LLE FLEX G1 600lm/m ta tp Rth, hs-a 1 Cooling area 1 25 C 65 C self-cooling 35 C 65 C self-cooling 45 C 65 C self-cooling LLE FLEX G1 1200lm/m ta tp Rth, hs-a 1 Cooling area 1 25 C 65 C self-cooling 35 C 65 C self-cooling 45 C 65 C 24.5 K/W 27.2 cm² LLE FLEX G1 1800lm/m ta tp Rth, hs-a 1 Cooling area 1 25 C 65 C 32.0 K/W 20.8 cm² 35 C 65 C 24.0 K/W 27.8 cm² 45 C 65 C 16.0 K/W 41.8 cm² 1 Values for a single segment of the LLE FLEX (50 mm). Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. 3. Installation / wiring 3.1 Electrical supply/choice of LED Driver LLE modules from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED Driver which complies with the relevant standards. The use of LED Driver from Tridonic in combination with LLE modules guarantees the necessary protection for safe and reliable operation. If a LED Driver other than Tridonic is used, it must provide the following protection: SELV Short-circuit protection Overload protection Overtemperature protection LLE must be supplied by a constant voltage LED Driver. Operation with a constant current LED Driver will lead to an irreversible damage of the module. Wrong polarity can damage the LLE FLEX. 2.2 Storage and humidity Storage temperature -35... +80 C Operation only in non condensing environment. Humidity during processing of the module should be between 30 to 70 %. 2.3 Thermal design and heat sink The rated life of LED products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the LLE will be greatly reduced or the LLE may be destroyed. www.tridonic.com 6

3.2 Mounting instruction None of the components of the LLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. The LLE FLEX is separable each 50 mm with the full function of each segment. Insulation must be ensured at the contact area of the segments (e.g. by using the connector ACL). The fixing/cooling surface must be cleaned before installing the LLE FLEX modules to remove all dirt, dust and grease. Prevent shear- or peel forces Min. bending radius of the LLE FLEX is 3 cm. Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. 3.3 Soldering guidelines The modules are suitable only for manual soldering (max. 260 C, 2 seconds). 4. Life-time 4.1 Life-time, lumen maintenance and failure rate The light output of an LED Module decreases over the life-time, this is characterized with the L value. L70 means that the LED module will give 70 % of its initial luminous flux. This value is always related to the number of operation hours and therefore defines the life-time of an LED module. As the L value is a statistical value and the lumen maintenace may vary over the delivered LED modules. The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the inital luminous flux, respectivly 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value. The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux. 4.2 Lumen maintenance for LLE FLEX 8mm Supply voltage tp L90 / F10 L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50 temperature 24 V 45 C 25,000 h 28,000 h 46,000 h 53,000 h >60,000 h >60,000 h 24 V 55 C 24,000 h 28,000 h 45,000 h 53,000 h >60,000 h >60,000 h 24 V 65 C 23,000 h 27,500 h 43,000 h 52,500 h >60,000 h >60,000 h 24 V 75 C 22,000 h 27,000 h 41,000 h 52,000 h >60,000 h >60,000 h 3.4 EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection www.tridonic.com 7

6. Photometric charcteristics 6.1 Coordinates and tolerances according to CIE 1931 The specified colour coordinates are measured integral by a current impulse with typical values of module and a duration of ms. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ± 0.01. 2,700 K x0 y0 Centre 0.4593 0.4055 0,4250 0,4200 0,4150 0,4 0,4050 0,4000 0,3950 0,3900 norm. intensity [%] 80 60 40 20 0,3850 0,4400 0,4450 0,4500 0,4550 0,4600 0,4650 0,4700 0,4750 0 380 420 460 500 540 580 620 660 700 740 780 MacAdam Ellipse: 5SDCM wave length [nm] 3,000 K x0 y0 Centre 0.4295 0.3984 0,4200 0,4150 0,4 0,4050 0,4000 0,3950 0,3900 0,3850 norm. intensity [%] 80 60 40 20 0,3800 0,4150 0,4200 0,4250 0,4300 0,4350 0,4400 0,4450 0,4500 0 380 420 460 500 540 580 620 660 700 740 780 MacAdam Ellipse: 5SDCM wave length [nm] 4,000 K x0 y0 Centre 0.3784 0.3727 0,3950 0,3900 0,3850 0,3800 0,3750 0,3700 0,3650 0,3600 norm. intensity [%] 80 60 40 20 0,3550 0,3650 0,3700 0,3750 0,3800 0,3850 0,3900 0,3950 0,4000 0 380 420 460 500 540 580 620 660 700 740 780 MacAdam Ellipse: 5SDCM wave length [nm] www.tridonic.com 8

6,500 K x0 y0 Centre 0.3085 0.3234 0,3400 0,3350 0,3300 0,3250 0,3200 0,3150 0,3 0,3050 norm. intensity [%] 80 60 40 20 0,3000 0,2900 0,2950 0,3000 0,3050 0,3 0,3150 0,3200 0,3250 0 380 420 460 500 540 580 620 660 700 740 780 MacAdam Ellipse: 5SDCM wave length [nm] 6.2 Light distribution The optical design of the LLE product line ensures optimum homogenity for the light distribution. relative intensity Iv/Iv, max -40 80-50 60-60 40 20-30 -20-10 0 10 20 30 40 50 60 70 80 0 - -80-60 -40-20 0 20 40 60 80 90 The colour temperature is measured over the complete module. The single LED light points are inside of 5SDCM. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 1 cm) should be used. 6.3 Relative luminous flux vs. tc temperature 105 rel. luminous flux [%] 95 90 25 30 35 40 45 50 55 60 65 70 tc [ C] 75 www.tridonic.com 9

6.4 Relative luminous flux vs. LED tape length LLE FLEX G1 SNC 600lm: 1,10 1,00 0,90 0,80 0,70 0,60 0,50 200 500 0 1500 2000 2500 3000 3500 4000 4500 5000 rel. luminous flux 5500 6000 6500 7000 7500 8000 8500 9000 9600 LED tape length [mm] LLE FLEX G1 SNC 1200lm: 1,10 1,00 0,90 0,80 0,70 0,60 0,50 200 500 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 rel. luminous flux 8500 9000 9600 LED tape length [mm] LLE FLEX G1 SNC 1800lm: 1,10 1,00 rel. luminous flux 0,90 0,80 0,70 0,60 0,50 200 500 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 9600 LED tape length [mm] www.tridonic.com 10

7. Miscellaneous 7.1 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. www.tridonic.com 11