Wireless Dry Contact Sensor

Similar documents
Wireless Dry Contact Sensor

Wireless Activity Sensors

Wireless Asset Sensor

VDC. Wireless VDC Voltage Meters. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications. General Description

Wireless Activity Sensors

Wireless Open / Closed Sensor

Wireless Button Press Sensor

Wireless Low Temperature Sensor

Wireless Open / Closed Sensor

Wireless Humidity (RH) Sensor

Wireless High Temperature Sensor

Wireless Dry Contact Sensor

Wireless Accelerometer - G-Force Snapshot Sensor

Wireless Digital Compass

Wireless 0-1 ma Current Meter

The Leading Enterprise Internet of Things Solution. Wireless Temperature Sensors TEMPERATURE. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Accelerometer - G-Force Snapshot Sensor. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Accelerometer - G-Force Snapshot Sensor. General Description

Wireless Accelerometer - Impact Detect Sensor General Description Features of Monnit ALTA Sensors Principle of Operation Example Applications

HUMIDITY. The Leading Enterprise Internet of Things Solution. Wireless Humidity Sensors. Features of Monnit ALTA Sensors. General Description

MonnitLink Wireless Cellular Gateways

The Leading Enterprise Internet of Things Solution. Cellular Gateways. General Description. ALTA Cellular Gateway Features. Wireless Range Comparison

Pharmaceutical / Lab. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Agriculture. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Industrial Manufacturing

Corporate Property. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Remote Real Estate. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

ALTA Serial Modbus (RTU/ASCII) Gateway Quick Start Guide

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

Monnit Wireless Sensors. and Ethernet Gateway Quick Start Guide

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

Arlo Pro 2 Wire-Free HD Camera Security System. Every Angle Covered. Pet Monitoring. Wire-Free or Plugged in. Security Made Simple

w w w. z i g s e n s e. c o m. a u

smartentry Wireless Video Doorphone User Manual

GS828. GPRS Data Logger

System Components Guide

Arlo Pro Wire-Free HD Camera Security System. Protect What Matters Most. Home. Business Security. Pet Monitoring

Wireless IoT Sensing Solutions

Deep Blue 10 Waterproof Bluetooth Speaker (IPX-6)

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

S05-SM User s Manual (ZigBee HA Profile) Ver. 1.02

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

RN-174 WiFly Super Module

Arlo Pro 2 Wire-Free HD Camera Security System. Every Angle Covered. Wire-Free or Plugged In. Security Made Simple. Pet Monitoring

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

Arlo Wire-Free HD Camera Security System

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

Overview. Back view. Package contents. Linksys WAP300N. Overview

GS828-H. GPRS Data Logger

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

T5a, T5b & T5c Temperature Tags

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

Cisco Aironet 1240G Access Point

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

I.D.OLOGY Wireless LightningROD Reader 5678A. Manual

LoRaWAN Pressure / Depth and Temperature Sensor

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

Industrial 1-Port Ultra PoE to 2-Port 802.3bt/at Gigabit PoE Extender

globaltag For Everything You Can t Afford to Lose

Wireless Smart MOTION SENSOR

LoRaWAN Pressure / Level and Temperature Sensor

Deluxe In/Out Remote Thermometer with Trend Chart

JT400 Multivariable Transmitter

Conductive Level Controller

RadioRA 2 Visor Controls

HomeWorks QS Visor Controls

A New, Standalone 24 Vdc Field Power Supply Reduces Costs, Simplifies Connectivity for Distributed I/O Devices on Industrial Machinery

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

Datalog IoT User Manual

LiveMote Connect & Control! Overview

COIN CELL CR2032. (Only for LED flash light) BRIEF SPECIFICATION

Standards. Electromechanical Safety Switches. Industrial Safety Products 179

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

Installation / User Manual

Solar Combiner Enclosure

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

KWJ-WSN & USB Gateway. Quick Start Guide

Energy consumption optimization for a wireless sensor for the IOT

Multiple Solutions in One Device

and Ethernet Gateway Quick Start Guide

See it. Control it. The TelPro Solution

Technical Specifications

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Rugged Mobile Computer PT21 / PT26. Portable Innovation Technology The Power Behind Your Rugged Mobile Computing

RadioRA 2 Visor Controls

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-PRO, UAP-AC, UAP-Outdoor+, UAP-Outdoor5, UAP-AC Outdoor

DELORME PowerPack for Earthmate GPS with Bluetooth GPS 9822

Datasheet. Enterprise WiFi System. Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5. Unlimited Indoor/Outdoor AP Scalability in a

Pioneer Petrotech Services Inc. Proudly Canadian. PPS33 & 33LR RemoteWatcher Multi-Sensor Wireless Monitoring System.

The Portable Air Pollution Monitor

Two Way ZigBee Wireless Remotes Two Way RF Remotes One Way IR Remotes REMOTES

OMNICOMM ON-BOARD TERMINALS

5GHz. Overview. Spotlight. Hardened IP65 Outdoor Wireless Bridge Subscriber Unit. PtP ITS

Product Documentation

Model VC-SHIELD Shield Box

Technical Specifications

ICS Entrance Management Sign Installation Guide. Version 1.0

Transcription:

The Leader in Low-Cost, Remote Monitoring Solutions DRY CONTACT Wireless Dry Contact Sensor General Description The Wireless Dry Contact Sensor can be used to detect contact between two wired contact points, an external mechanical switch or a contact plate. Features 1 ft. (12 inch) lead wires. Can integrate with switches. Principle of Operation Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. Monnit Sensor Core Specifications : 250-300 ft. (non-line-of-sight / indoors through walls, ceilings & floors) * RF Communication: 900, 920, 868 and 433 MHz Power: Replaceable batteries (optimized for long battery life, line-power and solar (Industrial only) options are available) Battery Life (at 1 hour heartbeat setting): ** Coin Cell > 2-3 years. AA battery > 4-8 years Industrial > 4-8 years Wifi > Up to 5 years * Actual range may vary depending on environment. (Wi-Fi sensors typical range is up to 100 ft.) ** Battery life is determined by sensor reporting frequency and other variables. The Monnit Wireless Dry Contact Sensor detects when there is contact between the two wired end points. It can easily be integrated into existing switches or contact plates. When the sensor detects contact between the two end points, it will immediately turn on the RF radio and transmit the data to the wireless gateway and imonnit Online Sensor Monitoring and Notification System, allowing the user to immediately receive an SMS text or email alert. The sensor can be configured to detect both closed and open loops alerting if contact is made or broken. Example Applications Barn door monitoring. Freezer / cooler door monitoring. Forklift seat switches. Button or switch integration. Production line tracking. And many more...

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) Wireless Dry Contact Sensor (Coin Cell) - Technical Specifications Supply Voltage 2.0-3.6 VDC * Current Consumption 0.7 µa (sleep mode) 2 ma (radio idle/off mode) 2 ma (measurement mode) 25 ma (radio RX mode) 35 ma (radio TX mode) Operating Temperature Range (Board Circuitry and Coin Cell) -7 C to +60 C (20 F to +140 F) ** Optimal Battery Temperature Range (Coin Cell) +10 C to +50 C (+50 F to +122 F) 0.7 oz. Range may vary according to environmental variables. 900 MHz product; FCC ID: ZTL- RFSC1 and IC: 9794A-RFSC1. 920 MHz product; ARIB STD-T108 R210-103733. 868 and 433 MHz product tested and found to comply with: CISPR 22:2008-09 / EN 55022:2010 - Class B and ETSI EN 300 220-2 V2.4.1 (2012-05). * Hardware can not withstand negative voltage. Please take care when connecting a power device. PinchPower Enclosure _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 2.470 4.375 3.295 1.111 1.111 Wireless Dry Contact Sensor (AA) - Technical Specifications Supply Voltage 2.0-3.6 VDC (3.0-3.6 VDC Using Power Supply) * Current Consumption 0.7 µa (sleep mode) 2 ma (radio idle/off mode) 2 ma (measurement mode) 25 ma (radio RX mode) 35 ma (radio TX mode) Operating Temperature Range (Board Circuitry and Batteries) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium ** Optimal Battery Temperature Range (AA) +10 C to +50 C (+50 F to +122 F) 3.7 Ounces Range may vary according to environmental variables 900 MHz product; FCC ID: ZTL- RFSC1 and IC: 9794A-RFSC1. 920 MHz product; ARIB STD-T108 R210-103733. 868 and 433 MHz product tested and found to comply with: CISPR 22:2008-09 / EN 55022:2010 - Class B and ETSI EN 300 220-2 V2.4.1 (2012-05). * Hardware can not withstand negative voltage. Please take care when connecting a power device. Power Options Two replaceable 1.5V AA sized batteries are included with the standard model. A line-power version with battery backup is also available - allowing it to be powered by a standard 3.0-3.6V power supply and use the internal batteries if there is a power interruption. Power options must be selected at time of purchase as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) Wireless Dry Contact Sensor (Industrial) - Technical Specifications Supply Voltage 2.0-3.6 VDC * Current Consumption 0.7 µa (sleep mode) 2 ma (radio idle/off mode) 2 ma (measurement mode) 25 ma (radio RX mode) 35 ma (radio TX mode) Operating Temperature Range (Board Circuitry and Battery) Included Battery Max Temperature Range: -40 C to +85 C (-40 F to +185 F) ** Capacity: 1800 mah Optional Solar Feature Solar Panel: 5VDC / 30mA (53mm x 30mm) Charging Temperature Range: 0 to 45 C (32 to 113 F) Max Temperature Range: -20 to 60 C (-4 to 140 F) Included Rechargeable Battery: 600 mah / >2000 Charge Cycles (80% of initial capacity) Enclosure Rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) 4.7 oz Range may vary according to environmental variables. 900 MHz product; FCC ID: ZTL- RFSC1 and IC: 9794A-RFSC1. 920 MHz product; ARIB STD-T108 R210-103733. 868 and 433 MHz product tested and found to comply with: CISPR 22:2008-09 / EN 55022:2010 - Class B and ETSI EN 300 220-2 V2.4.1 (2012-05). * Hardware can not withstand negative voltage. Please take care when connecting a power device. Solar Power Option Monnit Industrial Sensors are powered by a replaceable 3.6V Lithium battery (included). An optional solar powered version is also available. The solar powered sensor uses a Lithium Iron Phosphate rechargeable battery in conjunction with a solar power cell to extend battery life. PAGE 4

Height: 1.270 in (32.258 mm) 2.100 in (53.340 mm) 3.020 in (76.708 mm) MOWI Wireless Dry Contact Sensor (Wi-Fi) - Technical Specifications Networking Standards Frequency Band Wi-Fi Security Standards Wi-Fi Security Programming Network Settings Data Logging Power consumption Battery Life Wi-Fi Data Rate Electronics Operating Temperature LED Light IEEE 802.11 b/g 2.412-2.484 GHz Open, WEP, WPA, WPA2 Via PC software using USB cable. (Can be changed through imonnit online software.) Auto DHCP/DNS or Static Standard - On Wi-Fi disruption, unit will log the first 50 readings and transmit when Wi-Fi connection is re-established. Premiere - Unit can record up to 50,000 readings and transmit when Wi-Fi is available. 4uA sleep, 35mA active RX, 180mA TX (at +12dBm) Up to 5 years depending on sensor type, Wi-Fi security, distance from Wi-Fi router, reporting frequency and other variables. (Testing surpassed 90,000 transmissions until battery depletion.) Auto configures to best rate for maximum range. Up to 100 ft. device range (typical to standard Wi-Fi devices). Using Alkaline Batteries: -18 C to +55 C (0 F to +130 F) Using Lithium Batteries: -40 C to +85 C (-40 F to +185 F) Status / Activity 3.8 oz. Range may vary according to environmental variables. FCC ID: T9J-RN171. IC: RSS-210 low-power communication device. CE ID: 0681. * Hardware cannot withstand negative voltage. Please take care when connecting a power device. High Gain Antenna Option Monnit Wi-Fi sensors are also available with a detachable high gain antenna to provide a 20-30% increase in range over the standard Wi-Fi sensor. Option uses a different hardware configuration and must be chosen at time of purchase. PAGE 5

Notes: Commercial Grade Sensors Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc. Volatile or flammable gas. Dusty conditions. Under low or high pressure. Wet or excessively humid locations. Places with salt water, oils chemical liquids or organic solvents. Where there are excessively strong vibrations. Other places where similar hazardous conditions exist. Use these products within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt. Protects against wind-blown dust. Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. MDS-006-1B (1/18)