Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C

Similar documents
Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

McAfee Data Loss Prevention

Manager Appliance Quick Start Guide

Hardware Installation Guide Installation (x3350)

Rocsecure NE52 NAS System

Manager Appliance Installation Guide Revision B. McAfee Network Security Platform

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C

Cisco MCS 7835-H2 Unified Communications Manager Appliance

NAS System. User s Manual. Revision 1.0

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

Installing the IPS 4345 and IPS 4360

DNS-2608 Enterprise JBOD Enclosure User Manual

Reinstalling the Operating System on the Dell PowerVault 745N

Stonesoft Next Generation Firewall. Hardware Guide Models 3201, 3202, 3205, 3206, 3207, 3301, Revision F

Forcepoint Sidewinder Control Center, Virtual Appliance. Installation Guide 5.3.x. Revision A

Overview of Cisco 5520 Wireless Controller

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

McAfee Network Security Platform

Cisco NAC Appliance Hardware Platforms

Introducing the Cisco NAM 2220 Appliance

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

Barracuda Message Archiver Panel Indicators, Ports, and Connectors

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

G3-APEX-ENT-32T. Apex technical specifications. Parts list

Revision A. McAfee Data Loss Prevention Prevent 11.1.x Hardware Guide

Installation and Configuration Guide

G3-GS-4P-16T. Parts list G3-GS-4P-16T technical specifications. The G3-GS-4P-16T is best suited for small data centers or at your network edge.

Cisco MCS 7845-H1 Unified CallManager Appliance

Juniper Secure Analytics Quick Start Guide

8/16/32-Ch Network Video Recorder NVR Series

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

SCv3000 and SCv3020 Storage System. Owner s Manual

Installing and Replacing Hardware Options

iosafe BDR515 Hardware Guide

iosafe SERVER 5 Quick Start Guide

GETTING STARTED GUIDE. Cisco Small Business. NSS2000 Series Network Storage System

G3-GS-8P-1152T. Parts list. G3-GS-8P-1152T technical specifications. The G3-GS-8P-1152T is best suited for 40 Gb data centers.

Dell SCv3000 and SCv3020 Storage System Owner s Manual

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

Snap Server 4400 Power Supply

Installing the Cisco Unified Videoconferencing 3545 MCU

Dell Storage MD1400 Enclosures Hardware Owner's Manual

ReadyNAS OS 6 Desktop Storage Systems

Dell SC5020 and SC5020F Storage System Owner s Manual

Installation Guide. Getting Started with MaxAttach NAS 6000 Rack Mount Base Unit Systems

Next Generation Firewall

Barracuda Load Balancer ADC Hardware Features

ReadyNAS OS 6 Rack-Mount Hardware Manual

Panzura Freedom Filer Installation Guide

Stonesoft Management Center. Release Notes Revision C

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Appliance Guide. Version 1.0

Cisco TelePresence TelePresence Server MSE 8710

McAfee Network Security Platform

FreeNAS MiniandMiniXL Basic Setup Guide. Version 2.1

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Stonesoft Next Generation Firewall. Release Notes Revision A

Cisco TelePresence MCU MSE 8510

POWER. allows users to interface a third party control system with the devices on a VN Matrix network.

Stonesoft Management Center. Release Notes Revision A

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Wireless Network Video Recorder

Teradata Integrated Big Data Platform Platform. Hardware Replacement Guide for Customers. February 2018 B K

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Stonesoft Management Center. Release Notes Revision B

Hardware Guide. McAfee Web Gateway 7.8.0

G3-GSP-2P100-8TSSD Hardware Installation

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Introducing the Cisco 1121 Secure Access Control System Hardware

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Replacing an Advanced Power and Cooling (APC) Unit

16Hi HARDWARE INSTALLATION GUIDE

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SFP GIGABIT MANAGED SWITCH ECO

Introducing the Cisco CDE110

Stonesoft Management Center. Release Notes Revision B

The Cisco MCS 7835-H2 can run any of the following Cisco applications:

Installation and Configuration Guide

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Dell EMC PowerVault MD3460 Storage Arrays

Next Generation Firewall

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

A6106D/A6106H Blade PC Quick Start Guide

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

Symantec NetBackup 5030 Appliance Hardware Troubleshooting and Parts Replacement Guide

KVM Over the NET KN2116A KN2132 KN4116 KN4132. KN2124v. KN2140v. KN4124v. KN4140v

Installation Job Aid for Avaya Virtual Services Platform 7200 Series

Vess A3340s Vess A3340d

IPMI View User Guide

ThinkSystem SR650 Messages and Codes Reference

M1034W Engineering Workstation

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

Vess A3340 NVR Storage Appliance Quick Start Guide Version 1.0

GigaStor Upgradeable 2U. User Guide

Mainframe Data Library 6000 / 4000

Sylphit-Duo DSK-Series. KVM Drawer (with integrated KVM switch)

Transcription:

Sidewinder Control Center Hardware Guide Models C1015, C2050, and C3000 Revision C

Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Model features...4 Network ports... 7 Remote Management Module port... 7 Replaceable hardware components... 8 Regulatory information... 8 2 Using the Remote Management Module... 9 Configure the Remote Management Module... 9 Connect to the Remote Management Module web interface...10 3 Performing hardware maintenance tasks... 11 Replace a hard drive... 11 Replace a power supply... 12 Re-imaging the appliance... 12 Running hardware diagnostics...12 Interpreting system indicator lights... 13 2

Preface This guide provides the information you need to configure, use, and maintain your product. Find product documentation On the ServicePortal, you can find information about a released product, including product documentation, technical articles, and more. 1. Go to the ServicePortal at https://support.mcafee.com and click the Knowledge Center tab. 2. In the Knowledge Base pane under Content Source, click Product Documentation. 3. Select a product and version, then click Search to display a list of documents. Preface 3

Introducing the appliances Models C1015, C2050, and C3000 support Forcepoint Sidewinder Control Center version 5.1.0 and later. Model features Control Center appliances provide different maintenance and remote management features. The following table provides an overview of the models. Table 1: Model features Model Hard drives Power supplies Remote Management Module Rack height C1015 1 1 No C2050 2 (RAID 1) 2 Yes C3000 4 (RAID 5) 1U Model C1015 features Model C1015 has the following external features. C1015 rear panel The rear panel of model C1015 houses the AC power connector, keyboard and monitor ports, and network ports. Figure 1: Rear panel of model C1015 Number Description 1 AC power connector 2 PS/2 mouse port 3 Serial port 4 Default network port (eth0) 5 PS/2 keyboard port 6 VGA port Introducing the appliances 4

Number Description 7 Network port (eth1) 8 USB ports C1015 front panel The front panel of model C1015 houses the power button and system indicator lights. Figure 2: Front panel of model C1015 Number Description 1 USB port 2 Power button 3 System status indicator light 4 System power indicator light 5 Hard drive activity indicator light 6 NIC 1 activity indicator light 7 NIC 2 activity indicator light Introducing the appliances 5

Model C2050 and C3000 features Models C2050 and C3000 have the following external features. C2050 and C3000 rear panel The rear panel of models C2050 and C3000 houses network ports and replaceable power supplies. Figure 3: Rear panel of models C2050 and C3000 Number Description 1 System identification indicator light 2 System status indicator light 3 RJ-45 serial B connector (RS-232 serial port) 4 VGA port 5 USB ports 6 Default network port (eth0) 7 Network port (eth1) 8 Remote Management Module port 9 Power supply 1 status indicator light 10 Power supply 1 11 Power supply 1 AC connector 12 Power supply 2 status indicator light 13 Power supply 2 14 Power supply 2 AC connector Introducing the appliances 6

C2050 and C3000 front panel The front control panel of models C2050 and C3000 houses the power button and system status indicator lights. Figure 4: Front panel of models C2050 and C3000 Number Description 1 System identification indicator light 2 System status indicator light 3 Power/sleep indicator light 4 USB port 5 System identification button 6 Power button Network ports C1015 appliances have one network port. C2050 and C3000 appliances have two network ports. Network ports provide network connectivity for activities such as: Managing Forcepoint Sidewinder appliances Managing the Control Center appliance using the Control Center Client application Streaming log data to remote servers, such as syslog servers. Remote Management Module port Models C2050 and C3000 have a Remote Management Module port. The Remote Management Module provides system management features independent from the Control Center operating system. Note: The Remote Management Module cannot be used by Control Center and the port does not appear in the list of interfaces. You can use the Remote Management Module web interface to: View system information View system health, including: Sensor readings Introducing the appliances 7

Event logs Control the appliance remotely using console redirection Turn the appliance on or off Replaceable hardware components Models C2050 and C3000 have replaceable power supplies and hard drives. These components are hot-swap capable, so they can be installed or uninstalled while the appliance is operating. Note: Model C1015 does not have any user-replaceable hardware components. Regulatory information In compliance with FCC regulations, this section provides information about the appliance models and contact information. Model information The following regulatory information applies to models C1015, C2050, and C3000. Table 2: Regulatory model information Model C1015 C2050 C3000 Regulatory model SR1530 SR1625 SR1625 Contact information Use the following information to contact us. Forcepoint LLC 10900-A Stonelake Blvd Quarry Oaks 1, Ste 350 Austin, TX 78759 USA +1-800-723-1166 Introducing the appliances 8

Using the Remote Management Module Use the Remote Management Module to view appliance information independently of the Control Center Client application. Configure the Remote Management Module Use the BIOS to enable and configure the Remote Management Module. The module is disabled by default. If the appliance is deployed in a production environment, schedule a maintenance interval to enable the Remote Management Module. Note: Model C1015 does not include the Remote Management Module. 1. Connect the Remote Management Module port to a network. 2. Enter the appliance BIOS menu. 1. Restart or turn on the appliance. 2. Press F2 to enter the BIOS menu. 3. Navigate to the Server Management tab. 4. Select BMC LAN Configuration. Note: BMC configuration is not supported. If you want to configure BMC, use a different IP address for Control Center and BMC configuration. If you use the same address, the neighboring devices might display incorrect entries in the ARP table. 3. In the Intel RMM3 LAN configuration area, configure the following options: IP address Subnet mask Gateway IP address Note: Do not configure the Baseboard LAN configuration area. 4. In the User configuration area, define at least one user that will be allowed to access the appliance from a remote host. 1. In the User ID field, select the user ID that you want to configure. Note: The appliance has five user IDs for user information: anonymous, root, User3, User4, and User5. Each user ID can be enabled or disabled and assigned a privilege. These users have no connection to the Control Center software. 2. Configure the following options: Privilege User name User password 3. In the User status field, select Enable to activate the user ID. 5. Press F10 to exit the BIOS and save the changes. Using the Remote Management Module 9

Connect to the Remote Management Module web interface Connect to the Remote Management Module web interface from a remote computer. 1. In a web browser, navigate to https://<ip of Remote Management Module>. The first time you connect, accept the SSL certificate. 2. Specify a user name and password, then click Login. The home page appears. 3. Click the tab that corresponds to the task that you want to perform. Tip: For option definitions, click Help. Table 3: Web interface tabs Tab System Information Task View appliance information. Server Health View sensor readings. View the event log. Configuration Configure Remote Management Module network settings. Manage Remote Management Module users. Upload a new SSL certificate. Configure LDAP (Lightweight Directory Access Protocol). Remote Control Access the appliance console. Turn the appliance on or off. Note: To use console redirection you must allow the pop-up window to open, then download the Java applet. Note: When modifying network settings for the Remote Management Module on the Configuration tab, select Intel(R) RMM3 from the LAN Channel drop-down list. Do not configure the Baseboard Management LAN channel. Using the Remote Management Module 10

Performing hardware maintenance tasks Maintenance tasks include replacing hard drives and power supplies, re-imaging the appliance, and running hardware diagnostics. Replace a hard drive Replace a hard drive in a model C2050 or C3000 appliance. The appliance must have no more than one failed hard drive. If two or more hard drives have failed, contact technical support for assistance with re-creating the RAID container and restoring the software image. The replacement hard drive must have the same capacity or larger than the failed drive. You must have a number 2 Phillips screwdriver. C2050 and C3000 models have hot-swappable hard drives connected to a RAID controller. The RAID controller allows the system to continue operating in the event that a single disk dive fails. A single failed hard drive can be replaced while the system is operational. 1. Identify the failed hard drive. Tip: A failed hard drive usually has an amber indicator light. 2. Remove the failed hard drive from the appliance. 1. Press the aqua latch on the failed hard drive to release the spring-loaded black handle. 2. Remove the hard drive from the appliance by pulling on the black handle. 3. Use a screwdriver to remove the hard drive from the drive enclosure. 3. Prepare the replacement hard drive. 1. Remove the replacement hard drive from the protective packaging. 2. Compare the replacement hard drive to the failed hard drive to make sure the replacement hard drive has equal or larger capacity. Note: A lower capacity hard drive will not work. Contact technical support if you received a replacement hard drive that has a lower capacity than the failed hard drive. 3. Press the aqua latch to release the spring-loaded black handle. 4. Transfer the replacement hard drive into the empty drive enclosure, then tighten the screws with a screwdriver. 4. Insert the replacement hard drive into the appliance. 1. Slide the drive into the empty hard drive bay until it is fully seated. 2. Press the black handle until it latches. 3. If the appliance is turned off, turn it on. After the drive is inserted, the RAID controller begins the rebuild operation. When the rebuild operation begins, each hard drive shows activity. When the operation finishes, the drive indicator light changes from amber to green. CAUTION: Do not turn off the appliance until the rebuild operation is complete. Note: Performance is reduced while the rebuild operation takes place. Performing hardware maintenance tasks 11

5. Place the failed hard drive in the packaging materials of the replacement hard drive. Replace a power supply Replace a power supply in a model C2050 or C3000 appliance. Identify the failed power supply. C2050 and C3000 models have dual supplies that allow them to continue operating if one power supply fails. The power supplies are hot-swappable, so a single power supply can be replaced while the appliance is turned on and in operation or when the appliance is turned off. 1. Disconnect the power cord from the failed power supply. 2. Remove the failed power supply. 1. Unlatch the failed power supply by pressing the aqua handle to the left. 2. Continue pressing the aqua handle and remove the power supply by pulling the black handle. 3. Remove the replacement power supply from its protective packaging. 4. Slide the replacement power supply into the appliance until it is fully seated and the latch has engaged. 5. Connect the power cord to the replacement power supply. Note: Use both power supplies in normal operation, so that the two power supplies share the load. Re-imaging the appliance Two re-imaging methods are available. Installation USB drive For instructions, see the Firewall Enterprise Control Center Installation USB Drive Product Note for the version you are installing. CD [Models C2050 and C3000 only] For instructions, see the Forcepoint Sidewinder Control Center Release Notes for the version you are installing. Running hardware diagnostics If you suspect your appliance has a hardware issue, use the hardware diagnostics utility to troubleshoot. For instructions, see the Intel Diagnostics Tool for McAfee Appliances Instructions, available at http:// www.mcafee.com/us/downloads/downloads.aspx. Performing hardware maintenance tasks 12

Interpreting system indicator lights Control panel indicator lights provide system status information. Model C1015 indicator lights The following table describes the control panel indicator lights for Control Center model C1015. Table 4: Model C1015 control panel indicator lights functions Indicator light Color State Criticality Description System status Green Solid on OK System booted and ready ~ 1 Hz Blink Degraded System degraded: Non-critical temperature threshold asserted Non-critical voltage threshold asserted Non-critical fan threshold asserted Amber ~ 1 Hz Blink Non-critical Non-fatal alarm - system is likely to fail: Critical temperature threshold asserted Critical voltage threshold asserted Critical fan threshold asserted Solid on Critical, nonrecoverable Fatal alarm - system has failed or shut down: Thermtrip asserted IERR asserted Non-recoverable temperature threshold asserted Non-recoverable voltage threshold asserted Power fault/power control failure Off N/A Not ready AC power off, if no degraded, non-critical, critical, or non-recoverable conditions exist System power Hard drive activity NIC1/NIC2 activity Green On N/A Power on Blink N/A Sleep/ACPI S1 state Off Off N/A Power Off/ACPI S4 state Green Random blink N/A Hard drive access Off Off N/A No hard drive activity Green On N/A NIC link/no access Blink N/A LAN access Off Off N/A NIC disconnected Performing hardware maintenance tasks 13

Models C2050 and C3000 indicator lights Indicator lights for models C2050 and C3000 are described in the following sections. Control panel indicator lights The following table describes the control panel indicator lights for Control Center models C2050 and C3000. Table 5: Models C2050 and C3000 control panel indicator lights functions Indicator light Color State Description System identification System status Power/sleep Blue On System identification button pressed Off Off No identification Green On Running/normal operation Blink Degraded Amber On Critical or non-recoverable condition Blink Non-critical condition Off Off POST/system stop Green On Legacy power on/acpi S0 state Blink Sleep/ACPI S1 state Off Off Power Off/ACPI S4 or S5 state Power supply indicator lights The following table describes the power supply indicator light for Control Center models C2050 and C3000. Table 6: Models C2050 and C3000 power supply indicator light functions Color State Power supply condition Off Off No AC power to all power supplies Green Amber On Output ON and OK 1 Hz Blink AC present/only 5 VSB on (PS Off) On Either: No AC power to this PSU only (for 1+1 configuration) Power supply critical event causing a shutdown: Failure Fuse blown (1+1 only) OCP OVP Fan failed 1 Hz Blink Power supply warning events where the power supply continues to operate: High temp High power High current Slow fan Performing hardware maintenance tasks 14

Copyright 1996-2016 Forcepoint LLC Forcepoint is a trademark of Forcepoint LLC. SureView, ThreatSeeker, TRITON, Sidewinder and Stonesoft are registered trademarks of Forcepoint LLC. Raytheon is a registered trademark of Raytheon Company. All other trademarks and registered trademarks are property of their respective owners. Performing hardware maintenance tasks 15