MultiMux Multiplexer

Similar documents
MiniMux Multiplexer USER S GUIDE

INSTRUCTION MANUAL. RELAY MULTIPLEXER Model : RT-MUX 16/32. Roctest Limited All rights reserved

ELV12 Series. Instruction Manual

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Sensor Mux Wiring Diagrams MultiLogger Application Note #17 Revision March 2008

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Using the VWDSP Interface Application Note #11

Integrating the Yieldpoint d-exto MPBX

AZ420 MINIATURE GENERAL PURPOSE RELAY

CANARY. Acquisition Solutions. What Do We Do? Software Systems. Network Management. Sensors Input. Dataloggers Measure. Communications Transfer

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver XITANIUM 100W 2.30A INT-S XI100C230V042FNS1. Dimensions. Features.

Model Number Structure

Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21

Max. Input Power (W) Input Current (Arms) / 100 <15% >0.9. Dimming

SAMSUNG ELECTRO-MECHANICS CO., LTD

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver. Xitanium 40W 0.70A 0-10V INT-J XI040C070V056CNJ1. Dimensions.

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

Preliminary. LED Driver. Xitanium SR DRIVER 150W V 1.05A SR XI150C105V157VSF1. Specifications. Enclosure. Wiring Diagram

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

PT 3-PB-ST. Extract from the online catalog. Order No.:

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Installation & Operation Guide

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Integrating HART Sensors with the Campbell CR1000 Datalogger

ECC Chaining Modules

2U Congestion Alert Rack Insert for UK

Integrating the MDT SMART Link-485 Sensor Application Note #32

Tempco Instruction Manual

Max. Input Power (W) Input Current (Arms) / 83 <15% Dimming. Enclosure

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

LED Driver. Xitanium SR 150W V 0.7A SR XI150C070V235VSF1. Specifications. Wiring Diagram. Enclosure. Input and output use lead-wires.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

AquaTroll 600 Configuration and MultiLogger Integration

LED Driver. Xitanium DRIVER. 180W A 0-10V Dimming with SimpleSet and Aux. Output XI180C125V200PSF1. Specifications. Enclosure.

PESDALC143T5VU Low Capacitance ESD Protector

Model Datalogger (Micro-6000)

LGR-5325 Specifications

Model 7705 Control Module

Preliminary Product Overview

EP/2 Installation Instructions

Preliminary. LED Driver. Xitanium SR 75W V 0.7A SR XI075C070V118VSY1. Specifications. Enclosure. Wiring Diagram 1.50"

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

Integrating the RXTX Telependulum with the CR800/CR1000 Sensor Application Note #17

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Single Phase Systems-North American PC125/PC420 Series

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number AC-60CD1.4APPU

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

OPERATION MANUAL MODEL TT-LP

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver XITANIUM 75W 1.05A 0-10V HCN-F XH075C105V070CNF1. Dimensions.

LED55WPG Programmable LED Driver

}CLASS 2. LED Driver. Xitanium SR 95W V 2.75A SR XI095C275V054VPF1. Specifications. Wiring Diagram. Enclosure. Input and output use lead-wires.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

PLC497 ULTRA LOW CAPACITANCE STEERING DIODE/TVS ARRAY DESCRIPTION SOT-23 PACKAGE APPLICATIONS FEATURES MECHANICAL CHARACTERISTICS PIN CONFIGURATION

XI040C110V054BPT1 Brand Name XITANIUM XITANIUM 40W A 54V 0-10V w/t

Peak/Valley Hold Unit (PVHU) User Manual V3.00

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

EM8D-100L EMI FILTER/TVS ARRAY DESCRIPTION DFN-16 PACKAGE FEATURES APPLICATIONS MECHANICAL CHARACTERISTICS CIRCUIT DIAGRAM & PIN CONFIGURATION

USB208. ultra low capacitance steering diode array. Description. applications

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

M-Logger Copyright 2011 DGSI. All Rights Reserved.

Geokon Model D Pendulum Operation Notes Sensor Application Note #16

American Power Design, Inc.

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

DRIVER BROWN (LED+) YELLOW (LED-) VIOLET (NTC) GREEN (SGND) GREEN (SGND) ORANGE (RSET2)

must Operate Voltage (V)

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Gas Discharge Tubes GTCX36-XXXM-R10 Series

PSM WATT TVS ARRAY - ASYMMETRICAL DATA LINE PROTECTOR PIN CONFIGURATION

Model Number Structure

DSP240-LPI Inverter Controller Card. Technical Brief

Programmable Power Supply with DALI

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

PMAD Series. High Frequency Data Lines RS-232 & RS-422 Interface Networks Ethernet 10/100 Base T Computer I/O Ports

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Installing Sentor. Hardware Installation

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Model 2657A-LIM-3 LO Interconnect Module

Model 7701 Multiplexer Module

16-Way Input 48-Way Output Card

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

LGR-5327 Specifications

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Transcription:

MultiMux Multiplexer USER S GUIDE Disclaimer: The following document is provided to assist users with the installation, operation and training in the use of our products. This document and our products are intended to be used by technically qualified personnel. Contained herein is information that is proprietary to Canary Systems and may not be reproduced or copied in any form, nor disclosed to outside parties by any means whether directly or indirectly, without the written consent of Canary Systems. This document is subject to change without notice and Canary Systems assumes no responsibility for errors, omissions or misinterpretation. Furthermore Canary Systems makes no warranty as to the suitability of this information and/or products for any given application or use. Copyright 1998-2015 Canary Systems, Inc. All Rights Reserved. MultiLogger is a Registered Trademark of Canary Systems, Inc. All Rights Reserved Campbell Scientific is a Registered Trademark of Campbell Scientific, Inc., All Rights Reserved Multimux_usersguide.doc Revision F, 12-15 5 Gould Road, PO Box 2155 New London, NH 03257 USA Voice: (603) 526-9800 e-mail: support@canarysystems.com web: www.canarysystems.com

Table of Contents Section 1 Introduction 1.1 Overview... 3 1.2 Specifications... 4 Section 2 MultiMux Operation and Installation 2.1 Operation Details... 5 2.2 Daisy-Chain Operation... 5 2.3 Instrument Connection... 6 2.4 Digital Controller Connection... 6 2.5 MultiLogger Software Configuration... 7 2.6 CR1000 Program Example... 8 2.7 Panel Mount Installation... 9 2.8 Enclosure Installation... 10 2.9 Lightning Protection... 10 Section 3 Troubleshooting 3.1 Troubleshooting Flowchart... 11

Section 1 - Introduction 3 1.1 Overview The MultiMux expands the number of instruments that may be read by most all types of 5V/12V dataloggers in increments of 16 or 48 channels depending on the type of sensor being read. In addition, the MultiMux provides integral lightning protection by utilizing plasma surge arrestors. The MultiMux may be purchased installed in a NEMA 4X fiberglass/polyester enclosure or as an assembly for users who supply their own packaging. The MultiMux utilizes advanced high-reliability components such as terminal blocks from Phoenix Contact, relays from Panasonic and a flash microcontroller from Microchip Devices to help ensure years of reliable and trouble-free operation in almost any environment (components are rated to standard long term temp range of at least -40 C to +85 C). The use of low-contact resistance relays means almost universal instrument support, a high degree of lightning protection, and virtually infinite channel isolation. The warranty is applicable for two years from date of shipment. It does not cover failure by improper installation, misuse, or by nature including, but not limited to; flood, lightning (by improper grounding), fire, or other catastrophe. Should you encounter problems with your MultiMux, see Section 3.1 for the troubleshooting flowchart.

Section 1 - Introduction 4 1.2 Specifications General Power requirements: 11-16 VDC (unregulated) Quiescent current: 0.1 µa Channel activated current (2-wire): 39mA Channel activated current (6-wire): 52mA Control line input impedance: <10KΩ Control line input levels: 5V/12V Transient protection: TVS & Spark Gap Operating temperature: -40 to +70 C (-40 to +160 F) Relays Power: 11 ma @ 12VDC (140 mw) Contact type: Gold-clad silver alloy Electrostatic capacitance: 3 picofarads On resistance: 50 milliohms Coil resistance: 1,028 ohms Maximum switching voltage: 125 VAC, 110 VDC Maximum switching power: 30 W (resistive load) Maximum switching current: 2 A Operate time: ~2 milliseconds Release time: ~1 milliseconds Initial contact bounce: ~1 millisecond Surge withstand (between open contacts): 1,500 V Switching life (mechanical): 100,000,000 operations Lightning Protection Components Spark-over Voltage @ 100V/s +/- 20% Tolerance: 75V DC Impulse Spark-over Voltage @ 1kV/us: 600V DC Impulse Discharge Current 1 ka: 8x20us, 10 hits Impulse Discharge Current 100A: 8x20us 300 hits Impulse Withstanding Voltage 4kV: 10/700us 10 hits Capacitance @ 1MHz: <0.5pF Insulation Resistance @ 100VDC: 1000 MΩ UL Rating: UL497B #E179610 Dimensions: Overall (L x W x H): 10.75 x 8.875 x 1 (273 x 225 x 25mm) Mounting Hole Pattern (LxW): 10.25 x 8.25 (260 x 210mm) Mounting Hole ID: 0.216 (5.5mm)

Section 2 Operation and Installation 5 2.1 Operation Details The MultiMux is controlled by a digital controller using 2 digital control signals. The operation of the MultiMux is simple enough so that virtually any device capable of controlling 2 digital TTL/CMOS type signals can be used to control the multiplexer. Generally speaking, the timing diagram depicted below describes how the two digital signals are used to control the MultiMux. te: Timing values shown are minimum values. 50ms 250ns 250ns Enable Clock 1 2 15 16 Channel Channel 1 Channel 2 Channel 15 Channel 16 Channel In the case of the 48 channel modes, the maximum number of pulses to advance through all the channels would be 48. The channel switching mode is selected by configuring the DIP switch mounted on the MultiMux board. 2.2 Daisy-Chain Operation Daisy Chaining allows for a single set of digital control signals (and single cable) to control multiple multiplexers. The number of multiplexers that may be connected is technically unlimited as the control signals are re-generated at each multiplexer. Generally however no more than 20 multiplexers should be connected as power losses due to lead wire resistance and control signal latencies will potentially cause problems. To utilize Daisy Mux operation simply connect the ENO (Enable Out) to the EN (Enable) on the next mux. The CKO (Clock Out) is connected to the CK (Clock) of the next mux. When the MultiMux reaches the maximum channel (either 16 or 32 depending on the switch configuration) and more clocks are received, then the ENO becomes logic high. The CK outputs to CKO. The first mux switches to a low current standby mode. This continues until the next mux is at the maximum channel (either 16 or 48 depending on the switch configuration). To reset the entire string of multiplexers simply set EN low on the first multiplexer.

Section 2 Operation and Installation 6 2.3 Instrument Connection The way instruments are connected to the MultiMux will vary depending on whether it is configured for 16 or 48-channel operation. Use the DIP switch in the center of the assembly to configure the operation. The default configuration is 16-channel operation. The following table illustrates typical connection techniques for each of the operating modes: Mode Description Example 16 Channel (4-wire or 6- wire) Instrument #1 Temperature for Instrument #1 Connection 1H1 1L1 1H2 1L2 1H3 1L3 TB1 VW Gage #1 Thermistor in VW Gage #1 Connection 1H1 1L1 1H2 1L2 1H3 1L3 TB1 SHIELD SHIELD 48 Channel (2-wire) Instrument #1 Instrument #2 Instrument #3 1H1 1L1 1H2 1L2 1H3 1L3 TB1 VW Gage #1 VW Gage #2 VW Gage #3 1H1 1L1 1H2 1L2 1H3 1L3 TB1 SHIELD SHIELD 2.4 Digital Controller Connection The MultiMux is connected to a digital controller using the screw terminals at the bottom of the assembly. The terminals have the following connections: Terminal Description MLTB Mux Cable (5 pair) Mux Cable (6 pair) 1H High side of CH1 1H White Brown 1L Low side of CH1 1L White s Black Brown s Black 2H High side of CH2 2H Red Red 2L Low side of CH2 2L Red s Black Red s Black 3H High side of CH3 3H Blue White 3L Low side of CH3 3L Blue s Black White s Black S Gage shield S Overall Shield Drain Wire 1 Overall Shield Drain Wire 1 12V Power 12V Yellow Yellow G Ground G Yellow s Black Yellow s Black EN Mux Enable EN Green Green ENO Mux Enable Out N/A Green (to next multiplexer) Green (to next multiplexer) CK Mux Clock CLK Green s Black Green s Black CKO Mux Clock Out N/A Green s Black (to next multiplexer) tes: 1 Individual pair shield drain wires can be cut off. Green s Black (to next multiplexer)

Section 2 Operation and Installation 7 2.5 MultiLogger Software Configuration To configure MultiLogger to use the MultiMux select CAN MultiMux as your multiplexer Model on the Configure Multiplexers form. Before the individual channels may be edited you must select a Gage Type of the type of gage connected. Select either 16 Channel (default) or 32 Channel to match the DIP switch settings of the MultiMux. Once the multiplexer is configured press the Edit Channels button to configure the channels. If the MultiMux is being used in Daisy Chain mode then select the same Enable and Clock for all MultiMuxes in the string. For example, multiplexer #2 (using the same configuration shown above for multiplexer #1) would be configured as follows: te the Enable and Clock settings match multiplexer #1.

Section 2 Operation and Installation 8 2.6 CR1000 Program Example The following example illustrates how to write custom programs for the CR1000 to read instruments connected to the MultiMux. The example assumes a 16 Channel Mode MultiMux reading 16 MEMS inclinometers (voltage output). The MultiMux Enable is connected to C1, the Clock is connected to C8. 'Define Public Variables Public Mux1CHA(16) as Float Public Mux1CHB(16) as Float 'Define Other Variables Dim Channel as FLOAT Dim ScratchLoc(32) as FLOAT 'Define Data Tables DataTable(FSDATA,1,-1) Sample(16,Mux1CHA(),IEEE4) Sample(16,Mux1CHB(),IEEE4) ENDTABLE 'Main Program BeginProg Scan(60,SEC,1,0) Use C1 to Enable MultiMux PortSet(1,1) Delay(0,50,MSEC) Loop 16 times for entire MultiMux For Channel = 1 TO 16 'Use C8 to Send Clocking Pulse PulsePort(8,10000) Delay(0,100,mSec) Read MEMS Channel A on Differential CH1 Average 100 measurements ScratchLoc(3) = 0 For ScratchLoc(1) = 1 to 100 VoltDiff (ScratchLoc(2),1,mV5000,1,False,0,1000,0.001,0) ScratchLoc(3) = ScratchLoc(3) + ScratchLoc(2) Next Mux1CHA(Channel) = ScratchLoc(3) / 100 Read MEMS Channel B on Differential CH2 Average 100 measurements ScratchLoc(3) = 0 For ScratchLoc(1) = 1 to 100 VoltDiff (ScratchLoc(2),2,mV5000,1,False,0,1000,0.001,0) ScratchLoc(3) = ScratchLoc(3) + ScratchLoc(2) Next Mux1CHB(Channel) = ScratchLoc(3) / 100 Next 'Disable MultiMux PortSet(1,0) 'Data Output Programming CALLTABLE(FSDATA) NextScan EndProg

Section 2 Operation and Installation 9 2.7 Panel Mount Installation The MultiMux enclosure may be installed on a vertical or horizontal surface. Holes should be drilled and tapped with machine screws used for installation. Self-tapping panel mount screws may also be used. Dimensions are shown in the illustration. ø=.216 (5.5mm) 8.875 (225mm) 8.25 (210mm) 10.75 (273mm) 10.25 (260mm)

Section 2 Operation and Installation 10 2.8 Enclosure Installation The standard enclosure for the MultiMux is a Hoffman 12x10 fiberglass/polyester NEMA 4 type. The enclosure can be mounted to a wall or other surface by attaching the 4 supplied mounting tabs to the bottom of the enclosure using the supplied screws. The placement of the mounting holes is depicted in the illustration below. Mounting Hole (4 places) 8.00" (203 mm) 12.5" (318 mm) 12.94" (329 mm) Earth Ground Lug 2.9 Lightning Protection 10.5" (267 mm) The MultiMux is equipped with lightning protection components. As a result, case must be exercised in the installation to maximize their effectiveness. Specifically, an effective earth ground must be attached to the MultiMux or to the Field Enclosure earth ground lug for proper protection. Copper earth ground stakes and connecting wire are also available from Canary Systems.

Section 3 Troubleshooting 11 3.1 Troubleshooting Flowchart If you cannot obtain readings using the MultiMux or the readings are unstable then see the troubleshooting flowchart below for help in determining the nature of the problem. Start Does the MultiMux advance through the channels? Is 12V and G connected to the MultiMux? Attach 12V and G Are the switched leads connected? Connect the leads Are the Enable and Clock lines connected to the control ports? Attach Enable & Clock lines Is the wiring correct for the sensor leads? Adjust the wiring for the type of sensor used Do the software settings for the Enable and Clock lines match the connections? Match software and digital I/O connections Do the software settings match the sensor type and wiring? Adjust the software settings Is there a source of electrical noise nearby? Remove the noise source or move the MultiMux Do the circuit boards show water or other contamination? Clean the circuit boards Call Canary Systems for further assistance