QuickNetwork QND200 Distribution Panel

Similar documents
QuickNetwork QND300 Distribution Panel

12382 South Gateway Park Place, 700 Draper, UT

SuperPro. Distribution Panel. Users Guide. CSSPUGV1 11/04 Rev. A

U S E R S G U I D E. SuperPro Distribution Panel south gateway park place, 700, draper, utah

FT1R / FT1R-J Multi-Media Cable

Home Networks. Principles, Applications and Desirability

Installation Notes TII Model 341 Protector

Cabling Infrastructure

DOCKING STATION SPECIFICATIONS

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

NT1B-300 Rack Installation Instructions

ADSL Central Splitter Quick Setup Guide

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Intercom System 4.1 StructuredWiringSolutions Product Description... Application Description... Product Selection... Accessories...

Distribution Devices - Outlets, Jacks, & Plates

INSTRUCTION/INSTALLATION SHEET lyriq Studio High Performance Keypad

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

Business Customer Demarcation Information

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

SERVICE MANUAL MODEL SSW-520-F

INSTRUCTION/INSTALLATION SHEET lyriq High Performance Keypad Volume Control With IR

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Jack Plates. Jack Plates & Accessories PREMIER. PT-625B1 Flush Jack. PREMIER PT-625B3 Flush Jack

AT&T. PARTNER Communications System Remote Administration Unit. Installation and Use

Termination for 568A and 568B pin configurations.

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

HomeWorks Telephone Interface. Instructions for Installation and Use Please Read Before Installing. HWI-TEL9 18 V 60 Hz 300 ma

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

Basketball Shot Clock Set LX2180 Manual

TELEPHONE FLUSH WALL PLATE

HUAWEI FT2260 Home Phone Connect Quick Start

Modem Installation and Networking Instructions

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

SERVICE MANUAL MODEL SSW-521-D2-ADA

Cutter Option Installation Instructions

Executive Desktop Docking Station

ANSI/TIA/EIA-568-B Cabling Standard

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

ISDN 8510T Voice Terminal Instructions for Changing the EPROM

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

Users Manual for the MXD Personal Emergency Response System

Telephone Entry System

Installation and Operation

Ribbon Supply Spindle Maintenance Kit

Leased Line. NIONs. NCB Routers. Typical Application of NCB Routers

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

Mounts between 16-inch (406.4) OC studs (7.2) Mounts between 16-inch (406.4) OC studs (9.5) Mounts between 16-inch (406.

ActiveSite. Color Dial Pro. Product Guide

BL-FLOWSTN-P FlowStation Module Installation Guide

Keypad KEY-2.7. Instruction Manual

Installing Sentor. Hardware Installation

9/27/04 cci Cablecom Inc. 1

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1

StarServe Harmonicas. Wiring Instructions. Shallow. Deep. Angled. Telephone Modules 8052/4RJ 8052/4RJDMB 8052/4RJSMB Angled 3105ATPP2X4

User s Guide. Digital Whole Home Audio Distribution System

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)

Whisper-Ride

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

Installing the Cisco ATA

InnoMedia Business VoIP ATA Models

SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

SERVICE MANUAL MODEL SSW-321-X

EXT-DVI-CAT5-4X User Manual

Now with Picture Memory

BRN WHT/BRM BLU WHT/BLU GRN WHT/GRN ORG WHT/ORG

with its cables, connectors, Switches, Hubs and topologies

Copyright Black Box Corporation. All rights reserved.

Interconnect Product CATALOG Q700

Installing the PSU for the S50 and S50N

TRC-190 User s Manual

User s Guide. Digital Whole Home Audio Distribution System. Includes 8 audio source inputs and 8 amplified audio zones

ASSET LGA1366 Top-side Probe

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

PCS-2. Universal Infrared Remote PC Power Switch

Installation OVERVIEW

Addendum to the Actalyst Interactive Digital Signage Installation and User s Guide

Code Dynamics, Inc. Port Splitter

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad

Installing the Cisco VG224 Voice Gateway

HDMI Upgrade for the Showcase DVD

Replacing the Battery HP t5730 and t5735 Thin Clients

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

TVA2.1 2-Channel Digital Amplifier Installation Manual

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

PIX 535. PIX 535 Product Overview CHAPTER

FCC Regulatory Information

Note: Under no circumstances should you insert anything into the reset button hole. This will result in a failure of services.

INSTALLATION INSTRUCTIONS MODEL MRC44KP MRC44 KEYPAD

Transcription:

QuickNetwork QND200 Distribution Panel Installation Guide CSQND200V1 10/04 Rev. A

Before You Get Started This manual is designed to provide an overview of the installation process and guidelines for installing the system. Read the entire manual carefully before you begin your installation. You should be aware of and follow all local codes. Honeywell reserves the right to void the warranty on your Home Network System if it is not installed in accordance with the instructions outlined in this installation manual or with local codes. Home Network Systems As the number of services and electronic devices available to the homeowner increases, so does the need to control and manage these signals and services. Today multiple telephone lines, dedicated fax or computer lines, satellite TV, Internet connections, Digital cable, Digital dial tone and many other services are common. As a homeowner, we want the ability to control where signals from satellite TV or digital cable go in our home. We want to be able to move the office and easily reconnect to the Internet or the dedicated fax line. The Honeywell Home Network System is the means by which this can be accomplished. The system provides homeowners with the ability to control and manage existing services as well as the flexibility to add future services or electronics. The Home Network consists of three main components: Distribution Panel The Distribution Panel is an important component of the Home Network. A distribution panel can be used for anything from simple distribution of telephone and coax signals to provide the basis for a completely automated home. The value of the distribution panel is that it provides the homeowner with a central point where all incoming signals and the internal wiring in the house meet thereby allowing the homeowner to choose which signals are sent to any given location. Multi-Media Receptacles The Multi-Media Receptacle is used in locations where the homeowner plans to have a variety of electronic equipment or services. The home office is a good example. In the home office we want access to the main telephone line as well as a dedicated line for the computer or fax machine. We may also want a coax line for watching TV or Satellite TV and, should the doorbell ring, we might like to see who is standing at the front door without having to leave the office. The Multi-Media Receptacle is a single gang receptacle with a combination of telephone, data and TV connections. The most common configuration is two CAT5e and two coax connections. Speedwrap Cable Speedwrap Cable is a specialty cable consisting of a combination of telephone (2-Cat5e), coax (2-RG6 quad) and optional fiber optic cables (2-Multimode). This cable provides enough bandwidth and speed to allow almost any type of electronic signal or service to be distributed throughout the home. Description This Distribution panel includes a combination module that distributes TV, voice and data signals in a 6- inch rough-in can. The voice and data portion of this module is connected by eight RJ45 connectors that pass up to four lines. The TV distribution portion provides 4 outputs to feed up to 4 TV outlets and two Aux. Pas thru ports for Satellite LnB feeds. Networking or 10/100BaseT Data distribution through the telephone module is not supported. For data requirements you may purchase an optional component. The dimensions are (14.5 W x 6 H x 3.9 D) Features 1 video input, 4 outputs, 5MHz to 1GHz video splitter and IR passing 2 pass through connections for SATV signals 4 lines to 8 locations telephone distribution (RJ45) RJ31X port for connecting to a security system -2-

Labeling space for every port Installation Precautions Never install or work with telephone wiring during a lightning storm. Use caution when installing or modifying telephone lines. Have the Electrician connect the AC outlet to branch circuit power. The connection should be in accordance with the National Electrical Code, Articles 110, 250 and 300. Installation Installing the QN06 Install Can and Cover 1. The install can is 14½-inches wide, allowing it to be mounted between 16-inch on- center studs. To eliminate electromagnetic interference, select a mounting location that is a minimum of 16-inches away from the electrical load center. 2. The install can is equipped with built-in stand offs on each corner. These stand-offs are ½- inch deep and allow you to install the can so it will be flush with the sheetrock. 3. Determine the location where you want to mount the install can. When inserting the install can into the framed wall, be sure that the receptacle holes are at the bottom. Push the can back into the opening until the ½-inch stand-offs make contact with the studs. Use the provided screws to secure the install can to the studs. 4. After terminating all connections install the cover by aligning the plastic cover s holes with the threaded holes in the can. Using the two screws that are provided, attach the cover to the can. The lip of the cover extends out beyond the edges of the can over the sheetrock to provide a finished look. Connecting incoming TV and cable TV signal to the Module Connect the incoming Coax cable to the 90 F connector on the underside of the MDC4T8RJ module. -3-

Connecting the TV outlets to the module outputs Connect the coax cables running to the rooms (premise wiring) to the outputs (on the front of the MDC4T8RJ module. Connecting satellite TV signal to the Module 1. Connect incoming coax cables from the satellite dish to the pass-through F connectors on the rear of the MDC4T8RJ module. 2. Connect the cables running to the rooms (premise wiring) to the outputs on the front of the MDC4T8RJ module. Installing Telephone lines 1. Route a CAT5e twisted pair cable between the NID (The NID or network Interface Device is installed by the phone company) and the coax and telephone distribution module. 2. Identify the CAT5e wire running from the module to each of the rooms (premise wiring) and remove two (2) inches of the outer PVC jacket from the end, exposing the four (4) pairs. 3. Terminate each of the premise wires with an RJ45 Modular Telephone Plug using the 569A termination. -4-

4. Terminate the incoming CAT5e wire from the NID to the 110-style punch down block on the rear of the module. If you are also installing a security system, you can use the RJ31X port on the underside of the module to connect the security system. *Note: Make sure that the Tip and Ring is connected to the 110 punch down correctly. In most cases the Blue/White is first and then the White/Blue. Follow the same pattern with the remaining colors. The Tip & Ring is important so that the RJ31x port will work properly. 5. Plug the premise wiring into the RJ45 ports on the front of the module. If you are using a MDP-3 patch module, then use a patch cord to patch from the telephone outputs to the zones on the MDP-3 patch module. Connecting the module to a Security System After phone service has been connected to the module, route a CAT5 patch cord between the RJ31x port and the security system. Cut the RJ45 connector off at the Security system end and use the following diagram to connect the phone service to the security system and to the module. Separating Multiple Lines at the Room Location -5-

An LBO-1 Line Breakout Box will be required in order to redirect or access different lines at the room location. The LBO-1 plugs into an RJ45 connector on the plate and provides four RJ45 connectors that can be used to access each individual line by a 1 or 2 line phone. For example port 1 will access lines 1 and 2, port 2 will access lines 2 and 1, port 3 will access lines 3 and 4, and port 4 will access lines 4 and 3. The Pass Thru port is provided to allow you to chain multiple LBOs together or to allow an additional access point for line 1 and 2. -6-

- Notes - -7-

CSQND200V1$Š CSQND200V1 10/04 Rev. A