Tait GridLink THE INTELLIGENT CHOICE FOR DISTRIBUTION AUTOMATION. harris.com #harriscorp

Similar documents
DMR SOLUTION. Digital Mobile Radio (DMR) Solution Guide

NETWORK UPGRADE SOLUTIONS YOUR GUIDE TO UNIFIED CRITICAL COMMUNICATIONS

Dan Murray, Siemens Energy Management Division

APPLIED SATELLITE ENGINEERING-MACHINE-TO-MACHINE. This resource is brought to you by ASE M2M. Contact information.

SMARTPTT PLUS FOR MOTOTRBO PREMIUM CONTROL ROOM SOLUTION FOR MOTOTRBO DIGITAL TWO-WAY RADIO SYSTEMS SOLD AND SUPPORTED BY MOTOROLA SOLUTIONS

SurvalentONE Distribution Management System

LEVERAGE A WIRELESS BROADBAND INFRASTRUCTURE TO Open New Revenue Streams

BeOn Security Cybersecurity for Critical Communications Systems

Monitor Your Distribution Grid

What You Should Know About Communication Systems: Business Strategies and Options

ABB Communication Networks Latest News FOX615 / References with TROPOS Mesh

Translating lessons learned from TNBR-UNITEN s fully integrated smart grid test-bed to large scale deployments

FCIs reduce fault-locating times and improve reliability metrics, especially the Customer Average Interruption Duration Index (CAIDI).

DUKE ENERGY OHIO SMART GRID / GRID MODERNIZATION. Don Schneider GM, Smart Grid Field Deployment May 24, 2012

Subscriber Management -Billing data - Authentication NAP. Backhaul Access. Backhaul. Backhaul Access CCU BaseT CCU3000 B/U CCU3000

M2M Services. One global 3G network. One global SIM. ENTERPRISE > Service > M2M

Cisco SP Wi-Fi Solution Support, Optimize, Assurance, and Operate Services

Trust Harris for LTE. Critical Conditions Require Critical Response

Mesh Wide Area Network 4300 Series. Doubles the Flexibility of Municipal WiFi and Enterprise Networks

This webinar brought to you by the Relion product family

Multi-Service IP Communication for Metering and Grid Information

Smart Distribution Technology

Cellular Equipment in Electric Utilities

Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks

ALCATEL Edge Services Router

RADWIN IP Backhaul Solutions. Application Brochure. Meeting the escalating demand for IP backhaul

Critical networking using mesh Wi-SUN technology Dr Simon Dunkley

SCADA Solutions for Water and Wastewater Treatment Plants

Introducing Unified Critical Communications

TRBONET PLUS FOR MOTOTRBO PREMIUM CONTROL ROOM SOLUTION FOR MOTOTRBO DIGITAL TWO-WAY RADIO SYSTEMS SOLD AND SUPPORTED BY MOTOROLA SOLUTIONS

Wireless Network Virtualization: Ensuring Carrier Grade Availability

MANAGING THE COMPLEXITY.

Multi-Vendor Data Concentration of 7000 Distribution Devices to Facilitate Asset Optimization

ABB ABILITY NETWORK MANAGER X. SCADA for rail Operational confidence.

Mission Critical MPLS in Utilities

Juniper Care Plus Advanced Services Credits

Solving the challenge

Using Operator Interfaces to Optimize Performance of Industrial Wireless Networks

Thomson Reuters. FCN Services

INTEGRATION OF RECLOSERS INTO SCADA SYSTEMS

Brochure. Dialogic BorderNet Session Border Controller Solutions

wi4 Fixed Point-to-Multipoint Canopy Solutions

High performance monitoring & Control ACE3600 Remote Terminal Unit

Jussi Ahola, ABB Oy A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012


Questions & Answers From Thursday, September 16 Webinar Alternatives Case Examples Frequency and Spectrum Planning Security WiMAX Capabilities

Automation Services and Solutions

SystemsInsight QUICK REFERENCE GUIDE. Going further in critical communications

The Modern Manufacturer s Guide to. Industrial Wireless Cisco and/or its affiliates. All rights reserved.

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Achieving Optimal Returns from Wellhead Operations

Eight Essentials to Implementing Backhaul over Satellite for Mobile Operators. June 2009

Data Concentration of 7000 Distribution Devices to Facilitate Asset Optimization with the PI System

Exploring the ISA100.11a Standard. Exploring the ISA100.11a Standard. William (Bill) Ayers America s OneWireless Consultant.

The SCADA Connection: Moving Beyond Auto Dialers

SCADA Protocols. Overview of DNP3. By Michael LeMay

Chapter 5 Ad Hoc Wireless Network. Jang Ping Sheu

Substation. Communications. Power Utilities. Application Brochure. Typical users: Transmission & distribution power utilities

In-Vehicle Tracking Platform

Digital substations. Introduction, benefits, offerings

Transforming Utility Grid Operations with the Internet of Things

Why Converged Infrastructure?

HART COMMUNICATION. A Digital Upgrade For Existing Plants

MOTOROLA EXPEDIENCE TECHNICAL OVERVIEW

How SD-WAN will Transform the Network. And lead to innovative, profitable business outcomes

OneWireless Network Overview

GridEye FOR A SAFE, EFFICIENT AND CONTROLLED POWER GRID

Proven results Unsurpassed interoperability Fast, secure and adaptable network. Only EnergyAxis brings it all together for the Smart Grid

Using WiMAX for Distribution Automation

A Hybrid Communications Network Approach for Advanced Applications on the Modern Grid

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

ENERGY MANAGEMENT SYSTEM. ABB Ability Network Manager EMS Operational confidence.

SUPERVISORY CONTROL AND DATA ACQUISITION. Network Manager SCADA for rail. Operational confidence.

IP-Based Mass Notification Solutions for Businesses

SUBMARINE CABLE DEVELOPMENTS. Karthik Kailasam Jan 16, 2017; PTC Hawaii

Southern Company Smart Grid

Title of Presentation

April Oracle Spatial User Conference

Wireless Field Data Backhaul

Smart Solutions Smarter Grid

Connectivity to Cloud-First Applications

QEI. SCADA Remote Gateways & RTUs Substation & Feeder Automation Capacitor Control

Rajant Intrinsically Safe BreadCrumb Nodes Form a Ubiquitous Kinetic Mesh Network to Power Industry 4.0 Capabilities for Petrochemical Plants

SOLUTION BRIEF EXTREMEWIRELESS WiNG AZARA AZARA. WiNG RISE TO THE CHALLENGE OF PROVIDING SUPERIOR CONNECTIVITY & WLAN MANAGEMENT

TETRA in Energy Refineries, Oil & Gas. Gary Lorenz

CASE STUDY. Western Power Distribution ensures mission critical SCADA telemetry across operational areas in the UK

Cloud Services. Infrastructure-as-a-Service

Mesh Wide Area Network AP Elevating Bandwidth to the n th Power

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

ExtremeWireless WiNG NX 9500

Symantec Data Center Transformation

Alcatel-Lucent 1850 TSS Product Family. Seamlessly migrate from SDH/SONET to packet

Improving Business Continuity for the

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

WHITE PAPER ULTRA LOW LATENCY MICROWAVE THE NEED FOR SPEED: BEST PRACTICES FOR BUILDING ULTRA-LOW LATENCY MICROWAVE NETWORKS

Quicker response through increased collaboration

OneWireless Network Overview

GE Energy. Bently Nevada * Essential Insight.mesh * Wireless Condition Monitoring

Tunnelling SoluTionS

VERTIV SERVICE CAPABILITY

Transcription:

Tait GridLink THE INTELLIGENT CHOICE FOR DISTRIBUTION AUTOMATION harris.com #harriscorp

GRID VISIBILITY AND CONTROL Improving distribution grid operations with real time remote monitoring and control of grid assets has become simple and affordable with wide-area digital land mobile radio. Our communications infrastructure provides full feature voice services and wide area data transport services based on the Digital Mobile Radio (DMR) standard. Delivering power reliably and safely is a constant challenge for electrical distribution utility companies. The diverse environments that many utilities operate across pose reliability and resilience challenges for their distribution network. Improving their grid visibility and control over their distribution network is a key priority. Grid managers around the world have leveraged various types of communications to connect distribution line infrastructure and substations to their Supervisory Control and Data Acquisition (SCADA) systems. However, large parts of distribution grids remain off limits and are not visible or manageable due to the cost of connecting them. Providing data communication for Distribution Automation (DA) in remote areas with a low density of pole top and pad mount transformers, reclosers and capacitor banks is commercially challenging. In rural areas cellular coverage can be too inconsistent, unreliable and a security risk for mission-critical communications. Improving distribution grid operations with real time remote monitoring and control of grid assets has become simple and affordable with wide area digital land mobile radio. Harris DMR Tier 3 based communications infrastructure provides full feature voice services and wide area data transport services through our GridLink Solution. GridLink employs wide-area, trunked digital radio coverage to deliver a DA solution that is highly economic, reliable and secure, providing visibility and control of your entire grid. 2 Tait GridLink

COMBINES VOICE AND SCADA NETWORKS DMR Tier 3 Network TP9300 Portable TM9300 Mobile Pad Mount Device Pole Top Device DMR Base Station(s) Voice Network DMR Node Running GridLink SCADA Network Voice Dispatch SCADA Control Application GR16021v5 LEFT: Mobile field workers rely on voice based, work-group centric dispatch services for a safe and efficient work environment under all conditions from business-as-usual to black start. RIGHT: Remote devices on the distribution lines monitor and control the distribution grid. A SCADA control room application polls for and responds to remote event notifications from the remote devices using SCADA protocols such as DNP3 or IEC 60870-5-10x, which provide robust communication over narrow band PMR networks. GridLink BUSINESS BENEFITS GridLink provides utility managers with a layer of network intelligence that delivers both visibility and control over their grid, ensuring operational cost reductions, optimized energy usage, and improved grid reliability and resilience. OPERATIONAL COST REDUCTIONS With better grid visibility, utilities reduce operational costs with the ability to rapidly isolate and resolve faults and limit the scale of outages, all this in less time and with fewer people. OPTIMIZED ENERGY USAGE Electricity grid control enables utilities to optimize Volt/VAR, which in turn improves power delivery effectiveness and management. With better usage management, it is easier to ensure budgeted asset life cycles are realized and premature equipment failure or replacements are avoided. IMPROVED GRID RELIABILITY AND RESILIENCE GridLink gives managers improved visibility and control of electricity distribution networks, helping them predict potential weaknesses and improve grid reliability and resilience. That ensures better SAIDI and CAIDI metrics resulting in improved customer service and increased utility profits. The combined Voice and SCADA Network delivers two independent network services over a common infrastructure. This network topology ensures utilities benefit from a single communications vendor with only one network to design, deploy, maintain, harden and secure. The Intelligent Choice for Distribution Automation 3

HIGHLIGHTS OF THE GridLink SOLUTION GridLink builds on the Harris DMR Tier 3 radio platform to provide extremely reliable and robust voice and data communications. IMPROVED COVERAGE DMR Tier 3 delivers affordable wide area coverage for suburban and rural networks equivalent to analog radio systems. Combined, DMR Tier 3 and GridLink provide significantly wider area coverage for both voice and data than other industry technologies. Depending on terrain, DMR coverage allows outstations to be located up to 43 miles (70 km) from the base station sites. This minimizes the requirement for multiple base station sites, reducing capital costs of creating a wide area DA network. RELIABILITY AND RESILIENCE GridLink and the DMR Tier 3 radio network are designed for highly reliable network services. All infrastructure equipment is offered in redundant configurations to ensure business critical SCADA communications continue operations in the rare event of an equipment failure. GridLink employs DMR Tier 3 trunking capability to dynamically reassign traffic to radio channels, so if channels are lost, data will continue to pass through the network to its destination. SCALABILITY GridLink is a highly scalable solution, making it easy for a utility to deploy a small number of GridLink data terminals and then gradually scale up the solution, pole-by-pole, to a grid-wide system when required. 4 Tait GridLink

EASE OF INTEGRATION The integration of GridLink with SCADA control systems and outstation equipment is seamless. GridLink supports global SCADA communication standards with extensive experience integrating equipment from multiple vendors. Harris provides comprehensive support during system integration and roll out including tailored acceptance testing, deployment planning and project management to guarantee the successful operation of SCADA systems. SECURING GridLink All SCADA communications are encrypted to prevent unauthorized access to your electricity network. Access to the DMR radio network is also restricted to authorized terminals using DMR standard security authentication protocols. REMOTE MANAGEMENT AND CONTROL GridLink provides remote management and diagnostics facilities allowing console access to RTU/IED equipment, removing the need to physically visit outstations for routine maintenance activities. The status of all the GridLink equipment is made accessible via SNMP/MIB interfaces for display through industry standard Network Management Systems. DETAILED COMMUNICATION SYSTEM REPORTING GridLink systems monitor and provide detailed reports of system performance for both individual outstation and base station sites, including: Transaction latency and volumes to identify overloaded communication paths Transaction failure and retry metrics to identify failing equipment Received signal-strength and bit-error counters to identify interference or faulty antennas Supply voltage readings to confirm performance of outstation power supplies INDUSTRY STANDARDS DMR Tier 3 is a proven, open-standards-based radio protocol and GridLink supports major SCADA communications standards, including: DNP3 over both TCP/IP and serial IEC60870-5-101 and 104 Other communications protocols can be made available on request The Intelligent Choice for Distribution Automation 5

INTELLIGENT VOICE AND DATA NETWORKS GridLink builds on the proven value of DMR-based missioncritical voice by adding SCADA monitoring and control. Traditionally, wide area networks have delivered voice and data communications on separate networks. Network managers have accepted this duplication and associated costs as necessary to avoid complexities of combining voice and data interactions within their required Quality of Service metrics. The effectiveness of any DA solution depends on the reliability of the communications link between each device and the SCADA system. Intelligent technologies in digital TDMA-based trunking standards that effectively manage system resources are key to delivering combined voice and SCADA networking. GridLink leverages the Harris DMR Tier 3 radio platform to provide a robust communications link with market-leading security, reliable LMR voice communications and digital data functionality. The capacity doubling effect of two-slot TDMA combined with trunking resource management gives network operators new opportunities to: Prioritize network resources for voice or SCADA traffic Reserve channel resources for voice or SCADA, so dynamic network loading does not impact the quality of essential services Preempt call queues based on call priority and network loading 6 Tait GridLink

GridLink SOLUTION SCADA OMS/DMS Control Application Utility Control Room Network Management System (e.g., SolarWinds) DNP / IEC over IP Database SNMP DMR Node with GridLink Router Control Box DMR Base Station Sites(s) Sensors GridLink Terminal RTU / IED Switching DNP / IEC over Serial or IP Pole Top Transformer Capacitors Reclosers GR16022v3 HOW DOES GridLink WORK? GridLink builds on Harris proven experience in operations-critical voice solutions for electrical utilities companies with added expertise in data-enabled grid device monitoring and control. SCADA communications are passed from the control application to the GridLink communications server, located on the DMR Node and transmitted via the DMR Base Station sites to GridLink terminals at outstation sites. The GridLink solution passes SCADA messages using the packet data service on DMR traffic channels. In the event of RF interference, the GridLink terminal and communications server automatically resends communications ensuring messages are reliably passed between the SCADA equipment. More than 50,000 GridLink data terminals may be provisioned on a single network, subject to channel capacity constraints. The number of outstation RTUs and associated GridLink SCADA terminals supported by a logical 1 DMR channel is dependent on a number of factors, including the number of outstations and the frequency of status checks being conducted. 1 A single physical DMR channel provides two logical channels or timeslots. The Intelligent Choice for Distribution Automation 7

About Harris Corporation Harris Corporation is a leading technology innovator that creates mission-critical solutions that connect, inform and protect the world. The company s advanced technology provides information and insight to customers operating in demanding environments from ocean to orbit and everywhere in between. Harris has approximately $7.5 billion in annualized revenue and supports customers in more than 100 countries through four customer-focused business segments: Communication Systems, Space and Intelligence Systems, Electronic Systems and Critical Networks. Non-Export Controlled Information Harris is a registered trademark of Harris Corporation. 2017 Harris Corporation 01/17 CS-PSPC BR1612A The word Tait and the Tait logo are trademarks of Tait Limited. Tait Limited facilities are certified for ISO9001:2008 (Quality Management System), ISO14001:2004 (Environmental Management System) and ISO18001:2007 (Occupational Health and Safety Management System) for aspects associated with the design, manufacture and distribution of radio communications and control equipment, systems and services. In addition, all our Regional Head Offices are certified to ISO9001:2008.