Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Similar documents
Batch Controller with numerical keypad and receipt printer driver

PRESSURE MONITOR DATASHEET D053 - PRESSURE MONITOR WITH ONE HIGH / LOW ALARM OUTPUT.

BATCH CONTROLLER. Features. Input Options F130. DC powered with 7 yr battery or mains option. Overview

DATASHEET F111 - DUAL INPUT FLOW RATE / TOTALIZER

DATASHEET F043 - TEMPERATURE MONITOR

DATASHEET F115 - BI-DIRECTIONAL FLOW RATE INDICATOR / TOTALIZER

F112 Flow rate indicator / totalizer With linearisation and analog / pulse signal outputs

Batch Controller with Numerical Keypad

N410-P BATCH-CONTROLLER WITH NUMERICAL KEYPAD

DATASHEET F116 FLOWCOMPUTER

Industrial Process Controller. Model PC200. User Manual. CTL-UM EN-07 (April 2017)

DATASHEET F111 - DUAL INPUT FLOW RATE / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER WITH PULSE SIGNAL OUTPUT DATASHEET F014 - FLOW RATE INDICATOR / TOTALIZER

FLOWCOMPUTER WITH TEMPERATURE AND PRESSURE COMPENSATION FOR CORRECTED GAS VOLUME DATASHEET F126-EG - FLOWCOMPUTER

DATASHEET F074 - LEVEL / PUMP CONTROLLER

RATE / TOTALISER. Features. DC/Loop powered with 7 yr battery or mains option. Overview. Input Options. Outputs F110

Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs

DATASHEET F116 FLOWCOMPUTER

FLOW RATE MONITOR / TOTALIZER

Electronic Register (ERA)

DIFFERENTIAL FLOW COMPUTER DATASHEET F127 - FLOWCOMPUTER WITH TEMPERATURE COMPENSATION FOR CORRECTED LIQUID VOLUME AND AND PULSE SIGNAL OUTPUTS

DATASHEET F093 - TACHOMETER MONITOR

F110-P FLOWRATE INDICATOR / TOTALIZER

DIFFERENTIAL FLOW COMPUTER

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

NF760 Batch Controller

Clear Benefits of the KRAL Electronic.

MODBUS DISPLAY DATASHEET F193 - MODBUS DISPLAY WITH ALARM AND ANALOG OUTPUTS

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

VALVE POSITION INDICATOR

Batch Controller. Owner s Manual Model F130-P. Signal input flowmeter type P: pulse, Namur and coil. Status inputs: start and stop

BATCH CONTROLLER DATASHEET F030 - BATCH CONTROLLER WITH ONE STAGE CONTROL. Signal output One control output for one-stage batching.

F130-P BATCH-CONTROLLER

LAUREL ELECTRONICS, INC.

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

DATASHEET F116 FLOWCOMPUTER

NF770 Temperature Compensation Liquid Flow Computer

7511 / / / 711 / / 731 / Preset 27

DATASHEET F093 - TACHOMETER MONITOR

EZ Batch III Batch--Controller

Product Description. Contents. Fusion Series. New Information December 2003

KRAL Electronics BEM 300 and BEM 500.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

02/11/2015

Process displays For current and voltage

Digital Indicator Solutions

FLOW RATE INDICATOR / TOTALIZER DATASHEET F014 - FLOW RATE INDICATOR / TOTALIZER

PRODUCT CATALOG F-SERIES

LEVEL MONITOR DATASHEET F170 - LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

F-Series - Field mounted indicators for safe and hazardous areas.

User s Guide. Shop online at omega.com. FPD3100-D and FPD3100-D-A Series. 12mm LC Digital Display with Analog Output Options

Page 2. FL_F116P_v1702_01_EN

MIC-2 MKII, Multi-instrument DATA SHEET

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

02/11/2015

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

User friendly and easy to program

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Counting On Your Process Preset Counters

Simplified information where and how you want it.

FLOW MONITOR & TRANSMITTER

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES. Precision Digital Corporation

Vision OPLC. Technical Specifications. V T34 Technical Specifications

Trident and Trident X2 Digital Process and Temperature Panel Meter

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

F126-P-EL-TP FLOWCOMPUTER FOR CORRECTED LIQUID VOLUME

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Si 2035 Programmable Stepper Drive

DMT345 and DMT346 Dewpoint Transmitters

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

Photoelectric Sensors 20 Series

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Energy Management Modular Energy meters Type EM2-96

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Micro Motion Model 7950 and Model 7951 Signal Converters

Amplifiers, Counters, Timers & Controls

/8 DIN Universal Process Indicator

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Programmable Relay ZEN V2 Units

MPV. Process Panel Display. Dual-Line Rate and Total

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Andover ContinuumTM Infinet II

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

Neon pr. ph/ ORP measurement. Applications. Description

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Features and Benefits. Certifications

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Transcription:

Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to operate numerical keypad. Your crew is in control with our highly praised know one, know them all configuration structure, saving time, cost and aggravation. Key information at a glance as the display simultaneously shows actual value, preset value, batch process indication, relay status and measuring units. Easy installation with the rugged aluminum DIN-size panel mount enclosure. Features Five control inputs for remote START, HOLD, RESUME, keypad lock and external alarm. 7 large digits for actual value, flow rate, total and 10 smaller digits for preset value, accumulated total and batch count. Selectable on-screen engineering units; volumetric or mass. Power requirements: 24V DC / 110-230V AC. Sensor supply: 8.2 / 12 / 24V DC. No-flow monitoring. Automatic overrun correction. Modbus communication option RS232 / RS485. Outputs Two field replaceable, heavy duty, mechanical relays (make-and-break/ -), configurable for i.e. batching with one-stage or two-stage control. One transistor output for connection to PLC s or other controlling equipment. Inputs Ability to process various types of volumetric or mass flowmeter signals: Reed-switch, open collector, NPN, PNP or active 8/12/24V pulse signals. Applications Accurate batching or filling of liquids where the batch size changes frequently. The N410 offers the perfect solution for batch control applications where a user-friendly instrument is required. Whether you focus on its clear display information, the very easy to operate numerical keypad or the easy menu-driven configuration structure, Fluidwell is always your first and best choice. Alternative Fluidwell products: 300-Series. For analog inputs we offer our F-Series and D-Series batch controllers. For intrinsically safe applications we offer our field mount F-Series indicators. Save time and cost with the user-friendly N410 batch controller. Datasheet N410-1 -

General information Introduction The N410 batch controller distinguishes itself by its userfriendly features: Numerical keypad, clear programming menu structure, easy to read display and simple mounting enclosure. The numerical keypad allows simple and fast changing of the preset batch quantity. Fluidwell stands for simplicity and reliability and it is now available in this customer focused and application driven batch controller. Display The unique LCD display provides multiple batch control data at a glance. The main information like actual value, flow rate or batched total are displayed with 7 large digits (14mm, 0.56 ). The preset value and units of measure are displayed with 10 smaller segments (8mm, 0.3 ). A graphical indication of the batch process and relay status are displayed simultaneously. On-screen engineering units are easily configured in the configuration menu. All values are saved in EEPROM memory. The N410 is standard provided with a bright backlight, which ensures good readings during day and night and it can be adjusted in 6 steps from 0 to 100%. Configuration The N410 uses the highly appreciated configuration structure of our F- and D-Series. Each setting is clearly indicated with an alphanumerical description, eliminating confusing abbreviations. Once familiar with an N-series product, you will be able to program all models in all series without a manual. For example: the configuration menu of the (intrinsically safe) F-Series batch controllers operate almost identical to an N410! In other words: Know one, know them all. Operation and configuration is done via the easy-tooperate numerical keypad. All settings are accessed via a simple operator menu that can be password protected. No-flow monitor Following the START command, the flowmeter generates a signal. If this fails to come within the programmed time, an alarm is triggered. The batch is interrupted and the latest process values are stored in the memory. At the same time, the cause of the alarm is displayed. Alarm conditions are indicated visibly and can be configured as an alarm output. The No-flow function detects the absence of liquid, an obstruction in the pipeline or a breakdown. Control, Pulse or Alarm outputs Three outputs are available with the N410: two field replaceable, heavy duty relays and one transistor output. Relay 1 is fxed as the main batch control relay. Relay 2 and the transistor ouput can be configured as 1- or 2-stage batch control, alarm or pulse output. Communication All processed data and settings can be read and modified through the optional Modbus link (RS232 / RS485). Power requirements Two power inputs are available to power the N410 and sensor. A 110-230V AC and a 24V DC power supply. Both offer an 8.2, 12 or 24V DC sensor supply to power the sensor. Enclosures The N410 has an IP67 (NEMA4X) aluminum DIN size front panel and an IP20 GRP back cover. The removable screw terminal connectors on the back-side and the 4 mounting clamps make the N410 very easy to install. Limited depth clearance Batch sizes The preset value of the batched quantity can be programmed fast and easily by the operator via the numerical keypad. Repeating batches are executed, paused and reset easily with a start, hold and reset button. Flow meter input The N410 accepts various input signals for volume flow or mass flowmeters, like reed-switch, open collector, NPN, PNP or active 8 / 12 / 24V pulse signals. Very easy menu structure Overrun correction The Fluidwell N410 measures the overrun quantity at the end of every batch. With the automatic overrun correction procedure, the batch is corrected automatically; every run is executed with the highest accuracy. Save time and cost with the user-friendly N410 batch controller. Datasheet N410-2 -

Dimensions enclosures Overview application N410 72 (2.83 ) 1 2 3 4 5 6 RATE 7 TOTAL 8 COUNT 9 0 PRINT START HOLD PROG ENTER RESET Alarm / Pulse output Modbus Communication 144 (5.67 ) 5 Remote control inputs 66 (2.60 ) Flow meter input Start Hold Reset Alarm Keyboard lock 137.2 (5.40 ) Control output R1 Control output R2 104.7 (4.12 ) Terminal connections ADDITIONAL INPUT SENSOR INPUTS ADDITIONAL INPUTS CONTROL / ALARM or PULSE OUTPUT MAINS POWER REQUIREMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 22 23 24 IR: Keyboard lock P: Reed switch signal input IR: Start input OR: Passive transistor PG: 110-230V AC 12V P: NPN / open collector signal input IR: Hold input 12 (0.47 ) P: Active signal input ZS: PNP signal input 12V 12V 12V - IR: Batch reset input IR: Alarm input Panel cut-out SENSOR SUPPLY VOLTAGE POWER REQUIREMENT AND SENSOR SUPPLY OPTIONAL MODBUS COMMUNICATION CONTROL OUTPUT 1 CONTROL / ALARM or PULSE OUTPUT 138 (5.43 ) 67 (2.64 ) 24V DC 8.2V DC 27 28 PG: 24V DC 29 35 36 37 42 43 44 8.2 / 12 / 24V CB: RS232 RXD CH: RS485-2 wire TXD OR: 1 COM 46 47 48 OR: 2 COM A B 12V DC Maximum panel thickness: 6mm ( 1 /4 ) Display example 1:1-22 x 116mm (0.87 x 4.57 ) Save time and cost with the user-friendly N410 batch controller. Datasheet N410-3 -

Typical wiring diagram N410-P-CH-OR-PG-ZS Typical wiring diagram N410-P-CB-OR-PG TERMINAL CONNECTORS N410 24V DC POWER REQUIREMENT TERMINAL CONNECTORS N410 110-230V AC MAINS POWER REQUIREMENT A 35 36 37 42 43 44 46 47 48 Control output 1 type OR: Modbus communication type CH: RS485-2 wire TXD RXD 35 36 37 42 43 44 46 47 48 Control output 1 type OR: Modbus communication type CB: RS232 Power supply 27 28 29 Power supply type PG: 24V DC - Earth Power supply 27 28 29 Power supply type PG: 24V DC (Not used in this example) Earth Mains supply 12V 4.7kΩ 12V 4.7kΩ 12V 4.7kΩ 12V 4.7kΩ Signal 3 4 5 6 7 8 9 10 11 12 13 14 22 23 24 Mains power supply type PG: 110-230V AC (Not used in this example) e.g. alarm or counter passive transistor Additional input type IR: ALARM HOLD START Flow meter input type ZS: PNP pulse signal BATCH RESET Mains supply 12V 4.7kΩ 12V 4.7kΩ 12V 4.7kΩ 12V 4.7kΩ Signal 3 4 5 6 7 8 9 10 11 12 13 14 22 23 24 e.g. alarm or counter Flow meter input type ZS: Reed Switch Power supply type PG: 110-230V AC passive transistor Additional input type IR: ALARM BATCH RESET HOLD START L2 L1 12V 4.7kΩ 2 External input type IR: Keyboard lock 12V 4.7kΩ 2 External input type IR: Keyboard lock 1 1 *Supply voltage 5: 12V DC and supply voltage 29: 8.2 / 12 / 24V DC to sensor *Supply voltage 5: 12V DC and supply voltage 29: 8.2 / 12 / 24V DC to sensor Save time and cost with the user-friendly N410 batch controller. Datasheet N410-4 -

Technical specification General Display Type High intensity transflective numeric and alphanumeric LCD, UV-resistant. White LED backlight. Intensity adjustable from 0 100% in steps of 20%. Good readings in full sunlight and in darkness. Dimensions 22 x 116mm (0.87 x 4.57 ). Refresh rate Enclosure General Keypad Painting Seven 14mm (0.56 ) and ten 8mm (0.3 ) digits. Various symbols and measuring units. 8 times/sec. Die-cast aluminum front panel, GRP back enclosure. Polycarbonate window, silicone gasket; UV stabilized and flame retardant material. Sixteen industrial micro-switch keys; UV-resistant silicone keypad; replaceable front. UV-resistant 2-component industrial painting. Dimension 144 x 72 x 110mm (5.67 x 2.83 x 4.33 ) W x H x D. Classification IP67 (NEMA4X) at the front side. IP20 at the back side. Panel cut-out 138 x 67mm (5.43 x 2.64 ) W x H. Weight 650 gram / 1.7 lbs. Panel thickness Max. 6mm ( 1 /4 ). Operating temperature / humidity Temperature Storage Humidity Power requirements Type PG Sensor excitation Type PG Terminal connections Type Data protection Type Password Lock function -20 C to 60 C (-4 F to 140 F). -40 C to 80 C (-40 F to 176 F). 85% non-condensing, relative. 110-230V AC. Power consumption max. 10 Watt. 24V DC 10%. Power consumption max. 10 Watt. Terminal 5: 12V DC. I out max. 30mA. Terminal 29: 8.2 / 12 or 24V DC. 8.2V DC, I out max. 20mA. 12V DC, I out max. 30mA. 24V DC, I out max. 75mA. Removable plug-in terminal strip. Wire max. 2.5mm 2. EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be password protected. Complete keyboard can be locked with external input (e.g. key lock or PLC). Directives & Standards EMC Directive 2004/108/EC, FCC 47 CFR part 15. Low voltage Directive 2006/95/EC. IP & NEMA EN 60529 & NEMA 250. Signal input Flowmeter sensor Type P Option ZS Frequency K-Factor Low-pass Low Level High Level NPN, open collector, reed-switch, PNP or active 8 / 12 / 24V DC pulse signals. PNP input signal instead of NPN input signal. Minimum 0Hz - maximum 5kHz for total and flow rate. Maximum frequency depends on signal type and internal. E.g. reed switch with : max. frequency 120Hz. 0.000010-9,999,999 with variable decimal position. Available for all pulse signals. 0V DC min. to 3V DC max. 8V DC min. to 24V DC max. Load impedance 4.7kOhm pull-up to 12V DC. Current Additional inputs Function Type IR Logic Low Level High Level 2.5mA steady state. 5 remote control inputs: start, hold, reset, keypad lock and external alarm. Current sinking. Level sensitive. 0V DC min. to 3V DC max. 8V DC min. to 24V DC max. Load impedance 4.7kOhm pull-up to 12V DC. Current Response Signal outputs Digital outputs Type OR Pulse frequency Relays Transistor Communication option Function Type CB Type CH Speed Addressing 2.5mA steady state. 100ms make and break time. One batch output (always a mechanical relay). Two configurable outputs (one mechanical relay and one transistor): batch / two-stage control / any alarm / scaled pulse output. Max. 500Hz. Pulse length user definable between 1msec up to 10 seconds. 2 isolated, field replaceable, electro-mechanical relays (-). Max. switching capacity (resistive load): 8A @ 250V AC / 30V DC Max. switching power (resistive load): 2000VA 240W. One passive transistor output - not isolated. Load max. 50V DC - 300mA. Reading display information, reading / writing all configuration settings. Modbus RTU - RS232. Modbus RTU - RS485 2-wire. 1200-2400 - 4800-9600 baud. Maximum 255 addresses. Save time and cost with the user-friendly N410 batch controller. Datasheet N410-5 -

Datasheet N410 User friendly batch controller Reliable Operational Operator functions Functions Enter a preset value. Start, hold and stop the batch process. Total can be reset to zero. Batch counter can be reset to zero. Displayed Preset value. functions Running batch total or remaining quantity. Total and accumulated total. Flow rate. Batch counter. Graphical indication progress of the actual batch. Additional Active overrun correction. functions Minimum / maximum preset value. Preset / Total 7 digits. Units L, m 3, USGAL, IGAL, ft 3, bbl, kg, Ton, US Ton, lb. Decimals 0-1 - 2 or 3. Note Total can be reset to zero. Accumulated total 10 digits. Units / decimals According to selection for preset. Note Cannot be reset to zero. Batch counter 10 digits. Note Counter can be reset to zero. Flow rate 7 digits. Units L, m 3, USGAL, IGAL, ft 3, bbl, kg, Ton, US Ton, lb. Decimals 0-1 - 2 or 3. Time units /sec - /min - /hr - /day. Ordering information Standard configuration: N410-P-CX-HB-IR-OR-PG-XX-ZX. Ordering information: N410 -P -C _ -HB -IR -OR -PG -XX -Z _ Flowmeter input signal P NPN, open collector, reed-switch, active pulse signals. Communication CB RS232 communication - Modbus RTU. CH RS485 communication - 2-wire - Modbus RTU. CX No communication. Panel mount front enclosure HB Aluminum front panel - IP67 (NEMA4X). Additional input signal IR Remote control input to start, hold, reset, keypad lock and external alarm. Digital output signals OR 2 field replaceable, mechanical relays (-) and 1 passive transistor output. Power requirements PG 24V DC and 110-230V AC, both with sensor supply. Hazardous area XX Safe areas only. Other options ZS PNP input signal instead of NPN input signal. ZX No options. The bold marked text contains the standard configuration. Fluidwell bv P.O. Box 6 5460 AA Veghel Voltaweg 23 5466 AZ Veghel The Netherlands Telephone: 31 (0) 413-343 786 Telefax: 31 (0) 413-363 443 Email: displays@fluidwell.com Internet: www.fluidwell.com Specifications are subject to change without notice. Copyright: Fluidwell bv - 2015 - N410-DATA-EN-V1540