Digital electropneumatic Positioner for the integrated mounting on process control valves

Similar documents
Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Digital electropneumatic positioner

Digital electropneumatic positioner

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic positioner

Pneumatic Control/Feedback

Control head for decentralized automation of ELEMENT process valves

Digital electropneumatic positioner SideControl

Digital electropneumatic Process Controller

Control head for hygienic process valves

SideControl Positioner

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Installation kits for hygienic process valves

LFC Liquid Flow Controller

По вопросам продаж и поддержки обращайтесь:

Electromotive process valve - 2 way angle-seat shut-off valve

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Fieldbus Gateway Type ME43

Digital Positioner 8049

Electromotive process valve - 2 way shut-off globe valve

Operating pressure (bar) kv factor (m 3 /h) *3)

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Flow. Flow. N/en

Temperature Switches

Series 95000, 2/2 Direct solenoid actuated poppet valve

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases

21023, 21025, 2/2 Direct solenoid actuated poppet valves

T EN TROVIS Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner

Remote Process Actuation Control System AirLINE PHOENIX INLINE

80265 series, 3/2 Indirect solenoid actuated poppet valve

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Flow sensors SFAB Key features

Type 8694 Positioner Top Control Basic

26360, NAMUR. Technical data

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Level sensor Stainless steel version Model RLT-1000, for industrial applications

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

SPCH/ Big bottle blowing block

Linear Position Transducer HLT 1000-R2

HERION SERIES Indirect solenoid actuated spool valves

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Series 3730 Electropneumatic Positioner Type

Electromotive process valve - 2 way angle-seat control valve

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Mass Flow Meter (MFM)

GEMÜ 1235 Electrical position indicator

Montageanleitung / Operating Instructions Type

Control Head. Quickstart. English

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Material Seat seal. N/en

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Pressure sensors SDE5

Electronic pressure switch with display Model PSD-4

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Air gap sensors SOPA

AS-Interface I/O Module

24011 series, 3/2 Direct solenoid actuated poppet valve

Positioner CMSX-...-C-U-F1-...

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Pressure sensors SDE5

Electrical Position Indicator

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Compact pressure switch for multiple actuators

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Operating pressure (bar)

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

Series 3730 Type Electropneumatic Positioner

Pressure sensors SDE3, with display

SRD Z Intelligent Positioner stainless steel (316L)

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Multi-range pressure and differential pressure transmitter

Type 8692, Positioner and process controller Positioner und Prozessregler Positionneur et régulateur de process. Quickstart

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Technical Datasheet clima RCM-CC

Type Control Head. Operating Instructions

Distance and Position Sensors

System Control Unit (SCU)

Transcription:

Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface communication (option) Internal control air routing Type 2301 Globe Type 2300 Angle-seat Compact positioner for integrated mounting on pneumatically operated process valves. Remote setpoint adjustment via a 4-20 ma signal or through AS-Interface. Without instrinsic compressed air consumption during steady state. A contact-free analog position sensor measures the position of the valve spindle. Simple installation through automatic tune function and setting through DIP-switch: Close tight function Characteristic curves selection Reversal of effective direction Switching manual /automatic operation Binary input Additional parametrisation options are possible through DTM devices. A software interface can be used for, amongst others, linearisation of the operation characteristics by using free programmable fixed points. The valve position indication is shown through LED components. As an option an analogue position feedback can be integrated. Type 2103 Diaphragm Technical Data Material Body Cover Sealing Type 2702 Angle-seat PPS, stainless steel PC EPDM Hygienic process s Power supply 24 VDC ±10% Residual ripple max. 10% Setpoint setting 4 to 20mA (0 to 20mA adjustable via communication interface) Output resistance 180 Ω Control medium Dust concentration Particle density Pressure condensation point Oil concentration Ambient temperature Pilot air ports neutral gases, air DIN ISO 8573-1 Class 5 (<40μm particle size) Class 5 (<10mg/m 3 ) Cass 3 (<-20 C) Class 5 (<25mg/m 3 ) 0 to +60 C Threaded ports G1/8 stainless steel or Push-in connectors (Ø6mm and 1/4" tube) Supply pressure Low air fl ow rate 0 to 7 bar 1) High air fl ow rate 3 to 7 bar Air input filter Exchangeable (mesh aperture~0.1mm) Actuator system Actuator series ELEMENT 23XX Actuator series CLASSIC 27XX Position detection module Stroke range valve spindle Installation Low air fl ow rate : Ø Actuator 70 / 90 mm High air fl ow rate: Ø Actuator 130 mm Low air fl ow rate : Ø Actuator 80 / 100 mm High air fl ow rate: Ø Actuator 125 / 175 / 225 mm Contact-free, wear-free 3 to 45 mm as required, preferably with actuator in upright position Protection class IP65 and IP67 acc. to EN 60529 Protection class 3 according to VDE 0580 Conformity CE acc. to EMV2004/108/EG Options Analogue position feedback, 4-20mA Communication AS-Interface (option, in preparation) 1) The supply pressure has to be 0,5-1 bar above the minimum required pilot pressure for the valve actuator. www.burkert.com p. 1/9

Technical data - cont. Without filed bus communication Power supply 24 VDC +/- 10% Risidual ripple 10% Power consumption < 3.5W Electrical connection Multipole Cable gland M12 (8 pins), stainless steel 1xM16x1.5 (cable Ø5-10), terminal screws (1.5 mm 2 ) Technical Data AS-interface - (Option) Profile S-7.3.4 Output: 16 Bit setpoint / Certifi cate no. 87301 acc. to Version 3.0-7.A S.5 Output: 16 Bit setpoint; Input: 16 Bit feedback / Certifi cate no. 95401 acc. to version 3.0 Programmed Information see operating instructions Power supply through bus line 29,5 to 31,6 VDC acc. to specifi cation Max. Current consumption 150 ma Electrical connection M12x1, 4-pin stainless steel plug assembled to 80cm cable and fl at cable clip p. 2/9

Ordering information for TopControl-Control valve systems A complete TopControl-Control valve system consists of a Type 8694 and a process valve Type 23XX or 27XX. The following information is necessary for the selection of a complete : Item no. of the Positioner Type 8694 without process valve, see ordering chart on p. 3 Item no. of the desired process valve Type 23XX or 27XX (see separate datasheets, e.g. 2300, 2301 or 2702, 2712, 2730) Note: TopControl-Control valve system When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the datasheet. Example of variations of s 8694 Positioner Required process valve, example 2301 2702 Globe control Angle-seat valve Complete with required body and port connection Valve system Continuous ELEMENT Type 8802-GD-L 2301 + 8694 Valve system Continuous Classic Type 8802-YC-L 2702 + 8694 Customised attachment to 3rd party actuators* *: please see datasheet 8681/ELE- MENT installation kits to 3rd party process valves or contact your sales offi ce for related drawings or individual engineering support] p. 3/9

Ordering chart Type 8694 (other versions on request) Control function pilot valve system Communication Electrical connection Actuator series ELEMENT types 23xx actuator size Ø70/90mm Low air fl ow rate single acting Analogue feedback Pilot air ports threaded G1/8" Item no. Pilot air ports Push-in (tube Ø 6mm and 1/4") No M12 connector No 227 405 227 407 Yes 227 406 227 408 No Cable gland No 227 401 227 403 Yes 227 402 227 404 AS-Interface S-7.3.4 M12 / fl at cable clip / No 227 398 227 399 AS-Interface S-7.A.5 80cm cable 16 Bit via bus 239 615 239 613 Actuator series ELEMENT types 23xx actuator size Ø130mm High air fl ow rate single acting No M12 connector No 227 426 227 428 Yes 227 427 227 429 No Cable gland No 227 422 227 424 Yes 227 423 227 425 AS-Interface S-7.3.4 M12 / fl at cable clip / No 227 420 227 421 AS-Interface S-7.A.5 80cm cable 16 Bit via bus 239 616 239 614 Actuator series CLASSIC types 27xx actuator size Ø80/100mm Low air fl ow rate single acting No M12 connector No 227 416 227 418 Yes 227 417 227 419 No Cable gland No 227 411 227 414 Yes 227 413 227 415 AS-Interface S-7.3.4 M12 / fl at cable clip / No 227 409 227 410 AS-Interface S-7.A.5 80cm cable 16 Bit via bus 239 611 239 609 Actuator series CLASSIC types 27xx actuator size Ø125/175/225mm High air fl ow rate single acting No M12 connector No 227 436 227 438 Yes 227 437 227 439 No Cable gland No 227 432 227 434 Yes 227 433 227 435 AS-Interface S-7.3.4 M12 / fl at cable clip / No 227 430 227 431 AS-Interface S-7.A.5 80cm cable 16 Bit via bus 239 612 239 610 Approvals CSA NEMA4X AS-Interface version with external power supply Ordering chart adapter kit (has to be ordered separately) Description Actuator size Control function Item no. Adapter kit ELEMENT types 23xx Ø70 / 90 / 130mm universal 679 917 Adapter kit CLASSIC types 27xx Ø80mm universal 679 931 Ø100mm universal 679 932 Ø125mm A (NO), B (NC) 679 934 Ø175/225mm A (NO), B (NC) 679 935 for installation kits to 3rd party process valves please see datasheet 8681/ELEMENT or contact your sales office for related drawings or individual engineering support Ordering chart accessories Description Item no. M12 socket, 8-pins, 2m assembled cable 919 061 M12 socket, 8-pins, 5m assembled cable 919 267 Silencer G1/8 780 779 Silencer, push-in connector 902 662 Sensor puck (spare part) 682 240 USB interface for serial communication 227 093 p. 4/9

Materials 2 1 7 1 Cover PC 2 Body casing Stainless steel 3 Basic body PPS 4 Plug M12 Stainless steel 5 Screws Stainless steel 6 Push-in connector Threaded ports G1/8 7 Sealing EPDM POM/stainless steel Stainless steel 5 4 6 3 Dimensions [mm] Mounting on process valve, ELEMENT Types 23xx 91 115,4 91 13,5 31,7 102 14,6 17,1 54 Mounting on process valve, CLASSIC Types 27xx 91 115,4 92,6 13,5 31,7 102 17,1 14,6 54 p. 5/9

Mounting on third party hygienic process valves Customised attachment to 3rd party actuators* *: please see datasheet 8681/ELE- MENT installation kits to third party process valves or contact your sales offi ce for related drawings or individual engineering support] p. 6/9

Connection options Multipole connection 6 5 4 Pin Configuration 1 Setpoint + (0/4-20 ma) 2 Setpoint GND 7 3 3 Operating voltage GND 4 Operating voltage + 24 V DC 5 Binary input + 8 1 2 6 Binary input GND 7 Analogue position feedback GND 8 Analogue position feedback + Connection cable gland Screw terminal connections 1 2* 3* 4 5 6 7 * Option only Input signal Output signal with analogue feedback option Pin Configuration Pin Configuration 4 Setpoint + 2 Analogue feedback + 5 Setpoint GND 3 Analogue feedback GND 1 Binary input + 6 7 Power supply + Power supply GND p. 7/9

Connection options (cont.) Connection AS-Interface M12 4-pin plug assembled to 80cm cable and flat cable clip Screws M12 plug-in connector branch circuit Plug layout: from front looking at the pins, the solder is behind Pin 4: NC Pin 3: Bus Pin 4: 24 V + Pin 3: Bus Pin 1: Bus + Pin 2: NC Pin 1: Bus + Pin 2: GND Bus connection without external power supply Bus connection with external power supply (on request) Pin Designation 1 Bus + 2 NC or GND (optional) 3 Bus 4 NC or 24 V + (optional) p. 8/9

Signal flow diagram Position control loop Schematic diagram of the functions X.Tune function for automatic start-up Linear Close-tight function Reversal Switching Binary input Parametrisation of the device through Pact- Ware/DTM main functions: Setpoint value selection (0/4-20 ma) Postion controller parametrisation Programmable stroke range limit Limitation of opening/closing time Safety position definition Signal error detection Binary input configuration Analogue output configuration position setpoint/feedback Setting setpoint/actuator direction (rise/fall) Reset device Input for position set-point value 1) 4 20 ma 2) 0 20 ma Positioner Analog position feedback (Optional) 1) Binary input Inputs Outputs 24 V DC Communications interface Power. Operation 1) or optional bus connection AS interface 2) Default setting To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1210/5_EU-en_00895044 p. 9/9