Heavy Duty Psychrometer + IR Thermometer Model HD500

Similar documents
User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

User Guide. Moisture Meter. Model MO250

User's Guide. Model Laser Photo Tachometer

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

Heavy Duty Datalogging Light Meter

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model : BST-AFM05

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User's Guide. Datalogging Light Meter with PC Interface. Model

Laser Photo/ Contact Tachometer. m/min. ft/min

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200. Anemometer Thermometer AN200 UNITS NEXT AREA RECALL.

User's Manual. Professional IR Thermometer with USB

Digital Vane Thermo-Anemometer Model

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Heavy Duty Mini Vane CFM Thermo Anemometer

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

True RMS AC Voltage/Current Datalogger

User's Guide. Vibration Meter and Laser Combination Tachometer Model

Bedienungsanleitung Users Manual Mode d emploi. IR-Thermometer Pocket Thermomètre digital FIRT 550-Pocket

User's Guide. Phase Sequence and Motor Rotation Tester Model

Heavy Duty Vibration Meter

Mini Photo Tachometer Model Mini Contact Tachometer Model

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Heavy Duty Datalogger Module

Thermometers. Operation Manual

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Video Borescope. Model BR100

User's Guide. Digital Sound Level Meter. Model

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User's Guide. Model High Precision Quad Output DC Power Supply

Infrared Thermometer User Manual

User s Manual. Model and Sound Level Calibrators

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

User s Guide. 600A AC Clamp Meter. Model 38387

Heavy Duty Datalogger Module

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

Hygro Thermo-Anemometer Model

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

User's Manual Sound Level Alert Model SL130

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide Video Borescope Model BR200

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User Guide. ExStik FL700. Fluoride Meter

User's Guide. Temperature / Humidity Datalogger. Model 42270

Mini Digital Multimeter

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Dual Input, 3-Display Thermometer/Datalogger Model

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

3-Axis G-Force Datalogger

User's Manual. Digital Sound Level Meter. Model

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

Integrating Sound Level Datalogger Model

Heavy Duty Hot Wire CFM Thermo-Anemometer

Digital Sound Level Meter

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Guide. Mini Microscope. Model MC108

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

Hygro-Thermometer / Datalogger

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Power Analyzer Datalogger Model

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Large Vane CFM/CMM Anemometer / Psychrometer

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

True RMS Multimeter with IR Thermometer

True RMS Multimeter with IR Thermometer

Indoor Air Quality Meter/Datalogger

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer

Heavy Duty Datalogging Light Meter

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Vibration Meter and Laser Combination Tachometer

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

Dual Moisture Meter Pin / Pinless Moisture Meter

4-Channel Thermometer / Datalogger

Elcometer 214L. Infrared Digital Thermometer. Operating Instructions

I/R Thermometer Gun 8:1

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Heat Stress WBGT Meter

Autoranging Mini Multimeter Model MN16A

Light Meter with Bar Graph

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Ambient Weather WS-HT350 Fast Response Air Thermo-Hygrometer with Wet Bulb, Dew Point Meter User Manual

USER GUIDE FLIR TG165

Transcription:

User Guide Heavy Duty Psychrometer + IR Thermometer Model HD500

Introduction Congratulations on your purchase of the Extech HD500 Psychrometer. This handheld meter measures and displays Air Temperature, Relative Humidity, Dew Point, Wet Bulb and also Surface Temperature using the built-in IR thermometer. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features Triple digital LCD display. Fast response, all data is calculated four times per second. Standard type k(nicr-nial) Thermocouple input jack suitable for any style of type k probe. Infrared thermometer to measure surface temperature. Red laser pointer included. LCD with Backlight Automatic range selection USB interface. Low battery indication. Auto Power off. Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas 2

Meter Description 1. Humidity & Air Temperature Sensor 2. Type K Thermocouple input jack 3. Laser pointer beam 4. IR temperature sensor 5. USB Interface 6. LCD Display 7. Upper display HOLD button 8. Upper display Temp./Wet Bulb/Dew Point button 9. Upper display record Max/Min button 10. IR Measurement button 11. F/ C units button 12. Lower display HOLD button 13. Lower display record Max/Min button 14. Backlight button 15. Power button NOTE: Battery Compartment, Tilt Stand and Tripod Mount are located on the reverse side of the meter Display Description 1. Low Battery icon 2. PC communication icon 3. Upper display function icons 4. Upper display 5. Laser pointer icon 6. Lower display function icons 7. Lower display 8. Lower display function icons 3

Operation Basic Measurements 1. Press the button to turn power on. 2. The upper display will indicate Air Temperature, Wet Bulb Temperature or Dew Point Temperature and % Relative Humidity. Press the WB/DP button to toggle between Air, WB or DP. 3. The lower display will indicate Type K temperature or IR Temperature. Press and hold the IRT button to select the IR Thermometer. The TYPE-K function will display ------- if a type k probe is not inserted into the meter. 4. Press the C/ F button to change the temperature units from C or F. Non-contact IR Surface Temperature Measurements The built-in IR sensor can remotely measure the temperature of most surfaces. The Laser pointer allows the user to aim accurately when taking non-contact measurements. 1. Turn ON the meter using the button. 2. The IR sensor and laser pointer are located at the top of the meter. 3. Point the sensor toward the surface to be measured. 4. Press and hold the IRT button to begin measuring the surface temperature of a desired target. IR TEMP and will appear on the display. The laser pointer will switch on to help aim the meter. 5. The measured IR surface temperature will appear on the lower display. 6. When the IRT button is released, the laser pointer will switch off and the reading will freeze (data hold) on the display for approximately 7 seconds. 7. After the 7 second hold time the meter returns to the type k mode. WARNING: Do not directly view or direct the laser pointer at an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time. Data Hold 1. Press the HOLD buttons (one for upper display and one for lower display) to freeze the displayed value for the respective display. Press again to unlock the display. 2. The HOLD icon will appear on the display when the Data Hold mode is active. 4

MIN-MAX Recording Mode 1. Press the MAX/MIN button (one for upper display and one for lower display) to begin recording the Maximum and Minimum reading. The REC MAX icon will appear and only the maximum value measured will appear in the display. The display will update only if a value higher than the currently displayed value is measured. 2. Press the MAX/MIN button again to display the minimum values. The REC MIN icon will appear and only the minimum recorded value will appear in the display. 3. Press the MAX/MIN button again to display the currently measured values. The REC icon will appear in the display and the Max and Min values will be stored in memory. 4. Press and Hold the MAX/MIN button for >2 seconds to exit the mode. Auto-Power Off The meter will automatically turn off after 15 minutes of operation if no buttons are pressed during this period. Auto-power off can be disabled by: 1. Hold the IRT button and then press the button to turn the power on. When disapo appears in the display, release the IRT button and the APO is disabled. Low Battery When the battery reaches the minimum operating voltage the battery icon will appear in the display. Replace the 9V battery when this happens. Battery Replacement When the battery icon appears on the LCD, the 9V battery must be replaced. 1. The battery compartment is located on the rear of the meter. 2. Press in and down on the arrow located above the tilt stand hinge. 3. Replace the 9V battery 4. Replace the battery cover. Backlight Press the backlight button to turn the backlight ON or OFF. Note: continuous use of the backlight function will reduce battery life. USB Interface and Software The HD500 is equipped with a communication jack on its upper left side. The supplied communications cable connects to this jack and to a USB port on a PC. The supplied software allows the user to view and save readings to the PC. Instructions for use and features are detailed in the supplied software HELP utility. 5

InfraRed Measurement Considerations When taking IR measurements the meter automatically compensates for ambient temperature changes. Note that it may take up to 30 minutes to adjust to extremely wide ambient changes. Low temperature measurements quickly followed by high temperature measurements may require several minutes to stabilize as a result of the IR sensor cooling process. If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurements. If an object's surface is highly reflective apply masking tape or flat black paint before measuring. Steam, dust, smoke, etc. can obstruct measurements. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located. IR measurements cannot be made through glass. IR Theory IR thermometers measure the surface temperature of an object. The meter s optics sense emitted, reflected, & transmitted energy that is collected and focused onto the meter s detector. The meter s circuitry translates this information into an LCD reading. IR Field of View Ensure that the desired target is larger than the spot size. As the distance from an object increases, the spot size of the area measured by the meter becomes larger. The meter s field of view ratio is 30:1, meaning that if the meter is 30 inches (cm) from the target, the diameter (spot) of the object under test must be at least 1 inch (cm). Refer below to the field of view diagram. Emissivity Most organic materials and painted or oxidized surfaces have an emissivity of 0.95. Inaccurate readings will result when measuring shiny or polished surfaces. To compensate, cover the surface under test with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath then measure the temperature of the tape or the painted surface. 6

Thermal Emissivity Table for Common Materials Material Emissivity Material Emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Leather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.67 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.85 to 1.00 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxides 0.81 Plaster 0.80 to 0.90 Copper Oxides 0.78 Mortar 0.89 to 0.91 Iron Oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 7

Specifications General Specifications Display Dual Display Multi-function LCD with 9999 counts Data Hold Freezes displayed reading Sampling rate 1 reading per second Sensors Relative Humidity: Capacitance, Air Temp: Thermistor IR Distance to Spot ratio 30:1 IR Spectral response 6 to 14µm IR Emissivity 0.95 fixed MIN-MAX Record and Recall lowest and highest readings Auto Power OFF Automatic shut off after 15 minutes (can be disabled) PC Interface USB PC Communication with supplied software and cable for data acquisition Over range indication Dashes appears on the LCD Low battery indication Battery symbol appears on the LCD Power supply 9V Battery Operating conditions Meter: 32 to 122 o F (0 to 50 o C); 80% RH max. Dimensions / Weight Main instrument: 10.1 x 3.0 x 2" (257 x 76 x 53mm) Weight 12.5 oz. (355g) Range Specifications Function Range Resolution Accuracy Temp -148 F to -20 F ±(3.0% reading + 4 F) (type-k) -20 F to 2501 F ±(3.0% reading + 2 F) IR Temp -100 C to -30 C -30 C to 1372 C -58 to -4 F -50 to -20 C -4 to 932 F -20 to 500 C Air Temp. -4 to 140 F -20 to 60 C 1 1000 0.1 <1000 0.1 F/ C 0.1 F/ C 0.1 F/ C ±(3.0% reading + 2 C) ±(3.0% reading + 1 C) ±9.0 F / 5.0 C %RH 10% to 90% 0.1%RH ±2% RH <10% and >90% 0.1%RH ±3% RH Wet Bulb -6.88 to 140 F -21.6 to 60 C 0.1 F/ C calculated Dew Point -90.4 to 140 F -68 to 60 C 0.1 F/ C ±2% reading or ±4 F/2 C ±(2% reading + 2 F/1 C) calculated 8

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three (3) years from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Care Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2007 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 9

10