Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Similar documents
Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

SITRANS F flowmeters SITRANS F US

Flow Measurement SITRANS F US Clamp-on

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/317. Overview

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Flow Measurement SITRANS F US Inline

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F US Inline

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Continuous level measurement Ultrasonic transducers

Ultrasonic Flow Meter Brochure

Level Measurement Continuous level measurement - Ultrasonic transmitters

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F M

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Flow Measurement SITRANS F M

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Clamp-on Ultrasonic Gas Flowmeters Have Injected the New Blood into Natural Gas Check-metering and Custody Transfer Application

Model Sono-Trak General Specification

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Flow Measurement SITRANS F C

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Weighing Electronics Stand-alone integrators

Flow Measurement SITRANS F C

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Family of Water Cut Analyzers

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

Continuous level measurement Ultrasonic controllers

MAGFLO MAG 5100 W Benefits Application Flow Measurement Mode of operation Function Integration

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

SITRANS L Level instruments

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Aysix 200 Hand-Held Flow Meter

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Flow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Continuous level measurement Radar transmitters

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

DMTFP Portable Ultrasonic Flow Meters

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

UTM10 Series Ultrasonic Transit-time Flowmeters

Level Measurement Continuous level measurement - Ultrasonic transducers

Clamp-On Transit Time Ultrasonic Flow Meters

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

THE TECHNOLOGY BEHIND THE MEASUREMENT

Scanner 2000 microefm

Level Measurement Continuous level measurement - Ultrasonic controllers

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

OPERATING INSTRUCTIONS

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

... f l o w measurement & control...

PanaFlow Gas Meter System

Level-Lance Model 5400A

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

MPU 600 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Applications. Operating Specifications. Principle of Operation

AG3000 SERIES FLANGED MAGMETER

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

Micro Motion 7845/7847 Series Density and Concentration Meters

Level Measurement Continuous level measurement Ultrasonic controllers

Signet 2552 Metal Magmeter Flow Sensors

Flow Measurement SITRANS F C

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

Series DMHF Heat Meter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

AG3000 SERIES FLANGED MAGMETER

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview

Explosion Proof Weighing System

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

MPU 1600c. Eight Path Gas Ultrasonic Flowmeter. Principle of Operation. Features SPECIFICATIONS. Bulletin SSKS009 Issue/Rev. 0.

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

imag-series Flanged Magmeter

DUAL RANGE ACCURON 7200 CARTRIDGE METERS. eastech

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

Transcription:

Flow Measurement Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and unaccounted for (LUF) gas analysis Production Storage SITRNS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power station applications. SITRNS FUG1010 is available in single, dual and optional four path configurations, with your choice of IP65 (NEM X) or IP65 (NEM 7) and IP66 (NEM 7) explosionproof enclosures. Benefits Easy installation; no need to cut pipe or stop flow Minimal maintenance; external sensors do not require periodic cleaning No moving parts to foul or wear as found in turbine and PD meters Eliminates the pressure drop or energy loss in orifice metering Wide turn-down ratio Choice of single, dual or optional four path versions - Single path version reduces initial investment - Multiple path versions provide higher accuracy, especially with limited straight run and poor flow profile conditions - In diametric reflect mode configuration, the meter is less sensitive to crossflow and swirl Wide-Beam technology provides improved accuracy over a wide range of flow velocity and operating pressure ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow Tolerant of most wet gas conditions Immune to most pressure reducing valve noise Optional rugged stainless steel sensor enclosure permits permanent and direct burial installations Easy to use Si-Ware diagnostic software Design FUG1010 is available in three enclosures: IP65 (NEM X) enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single path - Dual path - Four path (optional) IP65 (NEM 7) Compact explosionproof enclosure constructed of cast aluminum with glass window, stainless steel hardware - Single path - Dual path IP66 (NEM 7) Wall mount explosionproof enclosure constructed of cast aluminum stainless steel hardware, with glass window - Single path - Dual path - Four path (optional) Function IP65 (NEM X) and IP66 (NEM 7) flow display transmitters have integral 33 button keypads and large (128 x 20 pixel) graphic displays visible up to 12 m (0 ft) away IP65 (NEM 7) compact flow transmitter has a 2 x 16 alphanumeric LCD display Current, voltage, frequency and RS232 outputs (see specification section for details) nalog inputs for pressure and temperature ZeroMatic Path automatically compensates for zero flow drift Bidirectional flow operation 1 Mbyte data logger with both site and data logger storage English, spanish, german, italian and french language options Internal G-8 table for fixed gas composition is available for standard volume computation. Complete application and operation diagnostics, to assure calibration and operational integrity Upward compatibility and compliance with G-10 speed of sound measurement practice /336 Siemens FI01 2011

Siemens G 2010 Flow Measurement Technical specifications Input ccuracy Flow range Flow sensitivity Minimum pressure Pipe size nalog inputs Output Standard outputs Extended outputs Status/larm I/O ± 30 m/s (± 100 ft/s), bidirectional 0.0003 m/s (0.001 ft/s), flow rate independent 7 10 bar (100 15 psi), typical (gas composition and application dependent; plastic pipes support operation at atmospheric pressure) 25 mm 1.52 m (1 8 ) (for other sizes, consult factory) Current: x 20 m, programmable (IP65 (NEM 7) enclosure has 2 x... 20 m, programmable) Current: x 20 m, a programmable, standard dditional 2 x optional, except IP65 (NEM 7) Voltage: x 0 10 V DC, menu programmable (None for IP65 (NEM 7) enclosure) x Open collector digital pulses (quadrature) (None for IP65 (NEM 7) enclosure) 2 x 0 5 khz, TTL pulse square wave + (None for IP65 (NEM 7) enclosure) 1 x Optically isolated digital pulse & source, IP65 (NEM 7) enclosure only RS232 Serial Port MODBUS (RS85/22/232) (not for IP65 (NEM 7) x programmable form C relays (not for IP65 (NEM 7) enclosure) x programmable N.O. Mer. Wet. Relays optional (not for IP65 (NEM 7) enclosure) 2 x Optically coupled output logic gates (for IP65 (NEM 7) enclosure, only) 1 Totalizer clear switch input (not for IP65 (NEM 7)) 1 Totalizer hold switch input (not for IP65 (NEM 7) enclosure) 1 x Opto iso. totalizer clear switch input (for IP65 (NEM 7) enclosure, only) 1 x Opto iso. totalizer hold switch input (for IP 65 (NEM 7) enclosure, only) Typical accuracy Calibratable ccuracy Repeatability Zero drift Data refresh rate Rated operation conditions Degree of protection 1 % 2 % of actual volume reading (higher accuracy is pipe condition and flow profile dependent) ± 0.2... 0.5 % of flow 0.05 % 0.1 %, of actual volume reading, for 1.5 30 m/s (5 100 ft/s) velocities (pipe condition dependent) 0.0003 m/s (0.001 ft/s), with ZeroMatic Path active 5 Hz Wall mount enclosure IP65 (NEM X) Compact explosionproof IP65 (NEM 7) Wall mount explosionproof IP66 (NEM 7) Gas temperature mbient temperature Design Dimensions Weight Power supply For IP65 (NEM X) and IP66 (NEM 7) For IP65 (NEM 7): Indication and operation Data logger memory Display IP65 (NEM X) and IP66 (NEM 7) enclosures IP65 (NEM 7) enclosure Keypad IP65 (NEM X) and IP66 (NEM 7) Enclosures IP65 (NEM 7) Enclosure Language options -0 +60 C (-0 +10 F) (for higher temperatures consult factory) -18 +60 C (0 10 F) see System info and selection guide see diagrams 90 20 V C, 50 60 Hz (30 V) or 9 36 V DC (12 W) 90 20 V C, 50 60 Hz (15 V) or 9 36 V DC (10 W) 1 Mbyte, programmable for 17 data functions 128 x 20 pixel LCD with backlight 2 x 16 alphanumeric LCD display 33 keypad buttons with tactile feedback 5 magnetic hall effect switches English, spanish, german, italian, french Siemens FI01 2011 /337

Flow Measurement Siemens G 2010 Certificates and approvals IP65 (NEM X) flow display transmitter ratings FM and CS I.S. Class I, II, Div 1 N-I Class I, Div 2 S Class II, Div 2 CE TEX INMETRO (Brazil) IP65 (NEM 7) compact explosionproof enclosure ratings EMC Directive 200/108/EC LVD Directive 2006/95/EG C-TICK Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nc [ia] IIC T5 Ex II 1 G Ex ia IIC T5 [BR-Ex ia] IIC BR-Ex nc [ia] IIC T5 BR-Ex ia IIC T5 IP65 FM and CS XP Class I, Div 1 D-I Class II, Div 1 I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2 CE TEX INMETRO (Brazil) IP66 (NEM 7) wall mount explosionproof enclosure ratings EMC Directive 200/108/EC LVD Directive 2006/95/EG C-TICK Ex II 2 (1) G Ex d [ia] IIB + H2 T5 Ex II 1 G Ex ia IIC T5 BR-Ex d [ia] IIB + H2 T5 BR-Ex ia IIC T5 FM and CS XP Class I, Div 1 D-I Class II, Div 1 I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2 CE TEX INMETRO (Brazil) EMC Directive 200/108/EC LVD Directive 2006/95/EG C-TICK Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nc [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB+H2 T5 Ex II 1 G Ex ia IIC T5 [BR-Ex ia] IIC BR-Ex d [ia IIC] IIB T5 BR-Ex ia IIC T5 /338 Siemens FI01 2011

Siemens G 2010 Flow Measurement Standard MLFB for quick delivery on SITRNS FUG1010 (Gas meter) Selection and Ordering data Order No. Order code SITRNS FUG1010 Gas Meter Clamp-on L) 7 M E 3 6 17-7777 0-7777 K 1 2 + K 1 2 + R 1 2 Design IP65 (NEM X) 0 Number of ultrasonic paths Dual path 2 Flowmeter functions and I/O configurations includes graphic or digital display Extended I/O option - additional 2 x... 20 m - Mercury wetted relays - x digital pulse outputs (2 x open collector and 2 x 0... 5 V TTL) Meter power options 9... 36 V, DC (except compact NEM 7) B Communication options RS 232 (standard) 0 MODBUS (dedicated only, excludes NEM 7 compact) 1 RTD temperature sensor (includes mounting hardware for pipes above 1.5 / 38 mm OD) No RTDs 0 1 x standard clamp-on RTD 1 2 x standard clamp-on RTD 2 1 x submersible clamp-on RTD 3 2 x submersible clamp-on RTD Notes: 1. Temperature input is required for FUH systems 2. Only the Interface detector set up as a dual channel can use 2 RTD s Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See Sensor selection charts for specifications. no sensor C2H (high precision) Mounting frame and 1200 mm (8") N D1H (high precision) Mounting frame and 1200 mm (8") P D2H (high precision) Mounting frame and 1200 mm (8") Q Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See Sensor selection charts for specifications. no sensor C2H (high precision) Mounting frame and 1200 mm (8") N D1H (high precision) Mounting frame and 1200 mm (8") P D2H (high precision) Mounting frame and 1200 mm (8") Q pprovals FM/CS/CE/C-TICK (default) 1 TEX, CE, C-TICK 2 Standard MLFB product offering represents to 6 weeks delivery time For sensor and RTD cables for quick delivery see tables at end of section. L) Subject to export regulations L: N, ECCN: 3991X. B Siemens FI01 2011 /339

Flow Measurement Siemens G 2010 Selection and Ordering data Order No. Ord. code SITRNS FUG1010 Gas meter clamp-on IP65 (NEM X) IP65 (NEM 7) compact IP66 (NEM 7) wall mounted Number of channels/ultrasonic paths L) 7ME3610- L) 7ME3611- L) 7ME3613-7777 0-7777 777 Single path 1 Dual path 2 Special: Four path (NEM X and NEM 7 wall mount only) 9 H 1 Flowmeter functions and I/O configurations (includes graphic or digital display) IP65 (NEM X) and IP66 (NEM 7 wall mounted) units Standard (all but Compact NEM 7) - Graphic display - x... 20 m analog input - 2 x 0... 10 V - 2 x... 20 m analog output - 2 x pulse output - x relay C type - 2 x RTD input Extended I/O option - additional 2 x... 20 m - Mercury wetted relays - x digital pulse outputs (2 x open collector and 2 x 0... 5 V TTL) IP65 (NEM 7) compact units Standard - Digital display - 2 x... 20 m (loop) - 2 x... 20 m analog input - 2 x status (open collector) - 1 x RTD input Digital pulse option 1 x digital pulse open collector output Mercury wetted relays for standard meter Z J 1 Dry contact form C relays for extended I/O meter Meter power options 90... 20 V C 9... 36 V DC (except compact NEM 7) B 9... 36 V DC negative GND (Compact only) J 9... 36 V DC positive GND (Compact only) K Communication options RS232 (standard) 0 MODBUS (excludes NEM 7 Compact) 1 RTD temperature sensor (includes mounting hardware for pipes above 1.5 outer diameter) No RTDs 0 1 x standard clamp-on RTD 1 2 x standard clamp-on RTD 2 1 x submersible clamp-on RTD 3 2 x submersible clamp-on RTD B D E Z J 1 D Selection and Ordering data Order No. Ord. code SITRNS FUG1010 Gas meter clamp-on IP65 (NEM X) IP65 (NEM 7) compact IP66 (NEM 7) wall mounted Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See Sensor selection chart for specifications. no sensor For the following 1H to DH sensors, temperature range is -0 C to 65 C (-1 F to 150 F), nominal 21 C (70 F): B1H (high precision) Trackmount and straps B2H (high precision) Trackmount and straps B3H (high precision) Trackmount and straps C1H (high precision) Mounting frame and C2H (high precision) Mounting frame and D1H (high precision) Mounting frame and D2H (high precision) Mounting frame and D3H (high precision) Mounting frame and DH (high precision) Mounting frame and L) 7ME3610- L) 7ME3611- L) 7ME3613-7777 0-7777 777 For the following B1H to DH sensors, temperature range is -1 C up to 10 C (30 F up to 220 F), nominal 65 C (150 F): B1H (high temperature range HP) Z P 1 K B2H (high temperature range HP) Z P 1 L B3H (high temperature range HP) Z P 1 T C1H (high temperature range HP) Z P 1 M C2H (high temperature range HP) Z P 1 N D1H (high temperature range HP) 1) Z P 1 P D2H (high temperature range HP) 1) Z P 1 Q D3H (high temperature range HP) 1) Z P 1 U DH (high temperature range HP) 1) Z P 1 R 1) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7ME3960-0MS0 (1012BN-). L) Subject to export regulations L: N, ECCN: 3991X. K L T M N P Q U R /30 Siemens FI01 2011

Siemens G 2010 Flow Measurement Selection and Ordering data Order No. Ord. code SITRNS FUG1010 Gas meter clamp-on IP65 (NEM X) IP65 (NEM 7) compact IP66 (NEM 7) wall mounted Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See Sensor selection chart for specifications. no sensor For the following 1H to DH sensors, temperature range is -0 C to 65 C (-1 F to 150 F), nominal 21 C (70 F): B1H (high precision) Trackmount and straps B2H (high precision) Trackmount and straps B3H (high precision) Trackmount and straps C1H (high precision) Mounting frame and C2H (high precision) Mounting frame and D1H (high precision) Mounting frame and D2H (high precision) Mounting frame and D3H (high precision) Mounting frame and DH (high precision) Mounting frame and Other versions (different size, mount, type or pipe larger than DN 1200 (8 ) or corrosion resistant), add Order code and plain text. K L T M N P Q U R Z Q 1 Y For the following B1H to DH sensors, temperature range is -1 C up to 10 C (30 F up to 220 F), nominal 65 C (150 F): B1H (high temperature range HP) Z Q 1 K B2H (high temperature range HP) Z Q 1 L B3H (high temperature range HP) Z Q 1 T C1H (high temperature range HP) Z Q 1 M C2H (high temperature range HP) Z Q 1 N D1H (high temperature range HP) Z Q 1 P D2H (high temperature range HP) Z Q 1 Q D3H (high temperature range HP) Z Q 1 U DH (high temperature range HP) Z Q 1 R pprovals FM/CS/CE/C-TICK (default) 1 TEX, CE, C-TICK 2 INMETRO (Brazil) 3 L) Subject to export regulations L: N, ECCN: 3991X. L) 7ME3610- L) 7ME3611- L) 7ME3613-7777 0-7777 777 Selection and Ordering data Further designs Please add -Z to Order No. and specify Order code(s). Cable assembly for sensors (add for # of paths) See Sensor cable selection chart Cable assembly for RTDs (add for # of RTDs) See RTD cable selection chart Cable termination kit (for one cable pair) Termination for standard, plenum and armored sensor cable Termination for submersible sensor cable RTD cable termination kit for standard RTD RTD cable termination kit for submersible RTD Insert RTD cable termination kit Languages (Meter and Documentation) German French Spanish Italian Tag name plate Stainless steel tags with 3.2 mm (0.13 inch) characters (68 characters max.) MLFB example pplication example clamp-on meter is required for a 300 mm (12 ) carbon steel gas line with a wall thickness of 12.7 mm (0.5 ). Meter electronics are to be located in a Class I Div 2 area only 18 m (60 ft) from the pipeline. 12 V DC power is available at the site. Dual path operation is desired for improved accuracy and redundant measurement. Pulse output will be primary flow data source. MLFB Order No.: 7ME3610-2BB00-0QQ1-Z K03 + K03 Order code K.. R.. T01 T11 T21 T31 T1 B10 B12 B13 B1 Y19 Selection and Ordering data Order No. Ord. code FUG1010 meter family 7 M E 3 6 17-7777 0-7777 777 IP65 (NEM X) enclosure 0 Dual path 2 Custody Transfer option with B digital pulse 9... 36 V DC power option B RS232 Standard 0 No RTD required 0 Sensor code for path 1 Sensor code for path 2 FM approval required 1 30 m (100 ft) sensor cab. for path 1 K 0 3 30 m (100 ft) sensor cab. for path 2 K 0 3 Selection and Ordering data Operating Instructions for FUG1010 English NEM x & NEM 7 Wall Mount German NEM x & NEM 7 Wall Mount English NEM 7 Compact Order No. Q Q 5E02951519 5E02951531 CQO:1010GCXFM-3 This device is shipped with a Quick Start Guide and a CD containing further SITRNS F literature. ll literature is also available for free at: http://www.siemens.com/flowdocumentation Siemens FI01 2011 /31

Flow Measurement Siemens G 2010 Sensor Selection Chart High precision sensors for steel pipe with outer diameter/wall thickness ratio >10 Sensor Order Pipe wall (mm) Pipe wall (inches) Code Size code min. max. min. max. B1H K 2.0 3.0 0.08 0.12 B2H L 3.0.1 0.12 0.16 B3H T 2.7 3.3 0.106 0.128 C1H M.1 5.8 0.16 0.23 C2H N 5.8 8.1 0.23 0.32 D1H P 8.1 11.2 0.32 0. D2H Q 11.2 15.7 0. 0.62 D3H U 7. 9.0 0.293 0.35 DH R 15.7 31.8 0.62 1.25 Sensor Cable Selection Chart Sensor cable codes for length and type options Cable length m (ft) Standard (PVC jacket) -0 +80 C (-0 +176 F) Order code Submersible (polyethylene jacket) -0 +80 C (-0 +176 F) Plenum Rated (teflon jacket) -0 +200 C (-0 +392 F) rmored 6 (20) K01 1) K11 K21 K31 15 (50) K02 K12 1) K22 K32 1) 30 (100) K03 1) K13 1) K23 K33 6 (150) K0 1) K1 K2 K3 61 (200) K05 K15 K25 K35 91 (300) K06 1) K16 K26 K36-0 +80 C (-0 +176 F) RTD Cable Selection Chart RTD cable codes for length and type Cable length m (ft) Standard (teflon wrapped) -0 +200 C (-0 +392 F) Order code 6 (20) R01 1) R11 15 (50) R02 1) R12 30 (100) R03 1) R13 6 (150) R0 R1 61 (200) R05 R15 91 (300) R06 R16 Submersible (extruded jacket) -0 +200 C (-0 +392 F) 1) Standard MLFB for quick deliver /32 Siemens FI01 2011

Siemens G 2010 Flow Measurement SITRNS FUG1010 Gas Check metering kit Overview Function Integral 33 button keypad and large (128 x 20 pixel) graphic display visible up to 12 m (0 ft) away Current, voltage, frequency and RS 232 outputs (see Technical specification section for details) nalog inputs for pressure and temperature Internal G-8 table for fixed gas composition is available for standard volume computation Upward compatibility and compliance with G-10 speed of sound measurement practice Bi-directional flow operation English, Spanish, German, Italian and French language options The clamp-on SITRNS FUG1010 Gas Check Metering Kit is an all-inclusive solution developed especially for verifying the accuracy and performance of any brand or type of flowmeter. The kit is ideal for natural and process gas applications, including check metering, allocation, production, storage and gas fired power station applications. The flowmeter is available with FM/CS or TEX approval. Benefits Performance check or verification of any type or brand of flow meter WideBeam technology provides improved accuracy over a wide range of flow velocity and operating pressure Tolerant of most wet gas conditions Immune to most pressure reducing valve noise Fast, easy and cost-efficient on-site measurement of any convoluted pipe from 50... 1200 mm (2... 8") up to 15.7 mm (0.62") pipe wall thickness Delivered as an all inclusive kit in a sturdy rolling case that holds all the equipment needed to conduct performance and verification tests (cables, multiple sensors, transmitter, etc.) Technical specifications Pipe sizes 50... 1200 mm (2... 8") up to 15.7 mm (0.62") pipe wall thickness ccuracy ±0.5%...1.0% of flow rate Flow range 30 m/s (100 ft/s) bidirectional Media temperature -0 +60 C (-0 +10 F) Enclosure ratings IP65 (NEM X) See page /337 for complete technical specifications Cerificates and approvals FM and CS I.S. Class I, II, Div 1 N-I Class I, Div 2 S Class II, Div 2 TEX Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nc [ia] IIC T5 Selection and Ordering data SITRNS FUG1010 Gas Check metering kit FM/CS approved TEX approved Ex II 1 G Ex ia IIC T5 Ex II 2 G Ex m II T5 (for use with flowmeter in safe area) Order No. CQO:FUG-GSKIT CQO:FUG-GSKIT pplication The SITRNS FUG1010 Check Metering Kit is ideal for most natural and process gas industry applications, including: Check metering llocation Flow survey verification Lost and unaccounted for (LUF) gas analysis Production Storage Design IP65 (NEM X) enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad Dual channel Content of delivery 1 Dual channel dedicated transmitter (FM/CS or TEX approved) 1 pair Transportable sensors C1 Pipe: od 3.500 inches, wt 0.216 inches, carbon steel 1 pair Transportable sensors C2 Pipe: od 6.625 inches, wt 0.280 inches, carbon steel 1 pair Transportable sensors D1 Pipe: od 10.750 inches, wt 0.365 inches, carbon steel 1 pair Transportable sensors D2 Pipe: od 16.000 inches, wt 0.500, carbon steel 2 pairs Sensor cables 6m (20 ft) 2 pairs Mounting frames 2 Spacer bar (dedicated) 1 Mounting strap Couplant CC128 1 kit Couplant/Damping Film 1 Flow case 1 Flowmeter manual 1 Laminated card set Siemens FI01 2011 /33