USB RF INTERFACE UIMrf

Similar documents
KNX USB INTERFACE UIMtp

DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 24 November 2017

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

CU-DIN USB KNX EC

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

Contents 1. Summary

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Product and Applications Description

Line Coupler, MDRC LK/S 3.1, GH Q R0001

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

DELTA i-system wall switch single UP 221/2 5WG AB_2

Operating and mounting instructions

Product and Application Description

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

KIMaip FAQS. Author: thiere_m. Version 1.2 Last Modification: / 9

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

DELTA profil wall switch, single UP 241/2 5WG AB_2

Power Supply System KNX PS640-IP

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Product and functional description

Weather station AP 257/51

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Push Button Interface UP 220D31

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Product and functional description

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Application description for the KNXnet/IP Interface Web

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Weather station GPS AP 257/61 Weather station AP 257/51

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

KSR-01IP KNX IP Router Instruction manual

IP gateway, MDRC IG/S 1.1, GH Q R0001

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Product and Application Description

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Push button UP 287, 4 - fold

Installer Manual Line/Field coupler KNX standard, installation on DIN rail (60715 TH35)

IntesisBox KNX SAMSUNG NASA Air Conditioners

Product and functional description

Product and functional description

instabus KNX / EIB product documentation

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Product and functional description

TXM1.8RB. TX-I/O Blinds module

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

KNX Radio Frequency (KNX RF) Products

Resistance measuring module

Operating instructions Evaluation system for flow sensors VS / / 2013

Product documentation

Technical Documentation

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Water-protected surface-mounted push-button bus coupler Order No , , ,

ERF910. RF Repeater. Synco living

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Power supply module, bus connection module

Operating instructions. Standstill monitor A / / 2011

ENGLISH DATALOGGER V2 ANALYZE. CONTROL. OPTIMIZE.

Power Supply Systems KNX PS640 and KNX PS640 USB

Contactless Data Transmission Channel

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

ENGLISH KNXCONVERTER PARLEZ VOUS ASCII?

PCAN-MicroMod Mix 3 Application-specific PCAN-MicroMod Motherboard. User Manual V2.1.0

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

584 5WG AB_1 DELTA

CU port USB 2.0 hub. Version: 1.1 Date:

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

NMEA 2000 to NMEA 0183 Gateway NGW-1-ISO. Installation Manual

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

IntesisBox KNX - BACnet/IP Client

AB Axis Industries. Use

Product and Function Description

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

252F 5WG FB_1 DELTA

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00


crio PN Installation Instructions V0.2/ COMSOFT

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

USB RF INTERFACE UIMrf TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 13 November 2017 2001-2017 TAPKO Technologies GmbH Im Gewerbepark A15, 93059 Regensburg, Germany Details, modifications and corrections may be subject to change without notice. TAPKO gives no warranty for the accuracy of the document. The reproduction, transmission and use of this document or its contents is not permitted without written authority. All rights reserved.

1 CONTENTS 1 Contents... 2 2 UIMrf Product Description... 3 3 Operational Description... 4 3.1 Current Interface of ETS Bus Connection... 4 3.2 Physical Address Assignment... 5 3.3 ETS Product Database... 5 4 State of Delivery... 6 5 Technical Drawings... 6 6 Technical Data... 7 7 Communication Data... 8 2 / 8 13.11.2017

2 UIMrf PRODUCT DESCRIPTION The TAPKO USB interface UIMrf connects a PC to KNX RF via RF data connection. With the ETS or another KNX compatible commissioning tool the UIMrf works as programming interface. Due to HID profile support no specific USB driver is required. As a KNX RF Ready S-mode device the UIMrf establishes access to all KNX RF bus devices for S-mode configuring (to feature commissioning, addressing, setting parameters, visualization, protocolling, and diagnostic operation) and E-mode installation. The protocol used for communication between interface and host is the flexible cemi protocol. The connection between KNX and a PC with standard software (like ETS, EITT, also in Raw Frame operating mode) or other software is handled by the FALCON driver. The UIMrf supports long messages (up to 208 bytes APDU length) and ensures easy software handling also under operating systems not supported by the FALCON driver (e.g.: Linux). For specific diagnostic applications like EITT the UIMrf supports the "Raw Frame" operating mode. The UIMrf is conforming to KNX-AN168 in all options. In MS Windows it is possible to execute software updates via a WEB frontend. For future KNX RF Multi and KNX Secure applications the UIMrf will be supported by appropriate firmware updates. With the latest firmware update the option route last flag is supported in cemi and in RF frames. 13.11.2017 3 / 8

3 OPERATIONAL DESCRIPTION In Microsoft Windows the UIMrf is recognized as HID (Human Interface Device). So, no extra drivers have to be installed or downloaded. The UIMrf s ETS database entries are available for ETS3.0d and upward. The device (dummy application without parameters and without communication objects) can be added to an ETS project as usual. In bus monitor mode the CRC-16 bytes are also contained in the data. For this reason the maximum telegram length that is usable in bus monitor mode is 178 bytes. The UIMrf can be connected to a PC also by a USB cable. To guarantee full functionality only use a USB cable with a maximum length of 3m. Picture 1: Connection diagram In combination with a TAPKO RF Media Coupler MECrf the UIMrf is able to access all devices of the KNX TP bus system. 3.1 CURRENT INTERFACE OF ETS BUS CONNECTION To use the UIMrf as the KNX programming interface in the ETS the UIMrf has to be chosen as the Current Interface. This can be done in the ETS Bus Connections tab and when editing a project, at the bottom line ( Name and state of current connection ) of the ETS window. Picture 2: ETS Bus Connections window 4 / 8 13.11.2017

3.2 PHYSICAL ADDRESS ASSIGNMENT The device is supplied with the individual physical address 15.15.255. With the ETS the physical address can be assigned to the device by setting the desired address in the Bus Connections window of the ETS. To download the desired physical address the UIMrf has to be chosen as the Current Interface. Then type in the Individual Address and press the Test button. Note: In this document only the term physical address is used. The term physical address means the physical address as well as the individual address. Both terms are used interchangeably by the KNX organisation. 3.3 ETS PRODUCT DATABASE The KNX product database entry (only as ETS dummy application) can be downloaded from our website and the KNX Online Catalog. Picture 3: TAPKO USB Interfaces in the ETS Catalog 13.11.2017 5 / 8

4 STATE OF DELIVERY The UIMrf is delivered with the following default factory settings: General Product USB RF Interface Application(s) - ETS Name USB RF Interface UIMrf Physical address 12.12.255 5 TECHNICAL DRAWINGS All dimensions shown here are specified in mm. Picture 4: Dimension drawings 6 / 8 13.11.2017

6 TECHNICAL DATA Marking/Design UIMrf Current consumption Tx: < 5 ma; Rx: <25 ma Connections USB2.0 connector (Type B) Protection type IP20 according to IEC60529 Pollution degree 2 according to IEC60664-1 Protection class III according to IEC61140 Overvoltage category III according to IEC60664-1 Approbation CE Marking Power supply KNX-certified according to ISO/IEC14543-3 Compliance according to low voltage and EMC guidelines: EN50491-5, EN60669, EN61000-3/-4/-6, EN62368-1 USB: 5V DC (SELV) Housing colour Plastic housing, white Dimensions H = 8.7 mm, W = 71 mm, D = 23 mm Weight Ambient temperature Ambient humidity 10 g Working: -10 55 C Storage: -20 60 C 5 93 %, non-condensing 13.11.2017 7 / 8

7 COMMUNICATION DATA KNX RF Serial number Used also as USB serial number KNX Ready (RF1) KNX Multi Configuration mode Bibat Yes (Listen Before Talk medium access) Hardware is ready for KNX Multi (firmware update soon available) S-mode Not supported max. APDU length 208 bytes (CRC-16 bytes included) 178 bytes (bus monitor mode) RF Performance RF Antenna Circuit-integrated RF Range Norms/Directives Frequency range Modulation Rx radiated sensitivity Tx radiated power up to 100m EN300220-2, EN301489-1/-3, EN55022, EN62479, EMV204/108/EC, LV2006/95/EC, RoHS2011/65/EU, RED2014/53/EU, 2011/65/EG 868.3 MHz + /- 300KHz FSK -95 dbm +0.9 dbm USB Type/Voltage USB2.0 / 5V USB cable Driver Sleep Mode Protocol Over HID KNX cemi KNX cemi Mask version 2311h Optional filtering mode Supported communication modes Maximum length is 3m HID Device, standard driver included in Windows/Linux Supported Individual address, repetition, domain address, extended Group address Raw Mode, Bus Monitor Mode, Link Layer Mode 8 / 8 13.11.2017