emfis emfis Operation and Instruction Manual HPL ELECTRIC & POWER PVT. LTD. AMP

Similar documents
Optidrive VTC Modbus RTU Register Map

Module with RS485 communication option for

RS485 MODBUS Module 8AO

COMMUNICATION MODBUS PROTOCOL

Conto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

How to set-up and read MOBBUS

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

CE4DMID01 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

3GV M Modbus RTU Register Map

RS485 MODBUS Module 16I-M

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

SM210 RS485 - JBUS/MODBUS for SM102E. User instructions

MODBUS Protocol Specification. MODBUS Protocol Specification V2.0

RS485 MODBUS Module 8I8O

MTR-4. C8 Command to MODBUS Bridge User Manual F-1, No. 631, Chung Der Road, Sec 1, Taichung Taiwan.

SPM33. MODBUS Protocol and register List V1.5

COMMUNICATION MODBUS PROTOCOL

RS485 MODBUS Module 8I8RO

Conto D1 MODBUS COMMUNICATION PROTOCOL

ELECTRONIC METER SX1-A31E MODBUS RTU Protocol Specifications MDD-T0025A

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

COMMUNICATION MODBUS PROTOCOL

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

RS 485 Mini Modbus 1AO

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 1

CURRENT PROTECTION RELAY SMPR-1

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK

DeviceNet for SERVOSTAR S300/S600/S700

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

DMTME Multimeters. Communication protocol. Technical specification V1.2 ABB

VPGate Manual PROFIBUS to serial

COMMUNICATION MODBUS PROTOCOL

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 3

The RS-485 user manual for B800 series communication

Interface Module XC Modbus Protocol Converter / User Manual

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

IF96017 MODBUS COMMUNICATION PROTOCOL

Modbus on tsense. Table of contents:

N700E Inverter RS485 Interface Instruction Manual

COMMUNICATION M-BUS PROTOCOL PR 118

Version Action Author Date

Modbus Protocol For FTS/FTM 3x&8x

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

Modbus Protocol For TGP03 / THP03

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

EM24-DIN PFA, PFB & X models

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

CAN-Transceiver Data Register Map MODBUS Slave RTU

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls

E2 Modbus RTU Register Map

RS485 MODBUS Module 6RO

M2M/DMTME Instruments Communication protocol. Technical specification V.2.1 2CSG445011D0201

IFC 100 Supplementary instructions

COMMUNICATION M-BUS PROTOCOL CE4DMID0M (MBus meter)

MODBUS MESSAGE PROTOCOL FOR MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER

EM300 Series. ET300 Series

SERIES PM130EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

Instruction Manual Modbus Converter Unigate-CL-RS

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Modbus Protocol For PMX / PXM3X

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

MCW Application Notes 24 th February 2017

Version 1.0c May 6, 2010 ATK3

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

EXD-TEVI Economizer Controller for Tandem Compressors

[ 公司地址 ] Modbus Protocol. For THS/THM 30X&80X_Temp.&Humididy & THS8X/THM8X_Dew Point Series V7.0

Modbus on CO 2 Engine and esense

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

MIC-2 Multi-instrument DATA SHEET

For more information Contact with details of the application.

Power Xpert C445 Motor Management Relay Cheat Sheets

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

Optidrive Applications Support Library

C192PF8-RPR. Power Factor Manager & Reactive Power Regulator Reference Guide. Modbus. Communications Protocol. BG0348 Rev. A1

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MODEL CIO-EN PROGRAMMING GUIDE MODBUS/TCP, MODBUS/RTU I/O MODULE. Revision A1 Rapid City, SD, USA, 09/2008

FPU-16 A-B PROTOCOL/DATA LOGGER MANUAL

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

TECHNICAL NOTES By6150-S-485 MODBUS J BUS Communication

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

Series AVUL Air Velocity Transmitter with Modbus Communication. Specifications - Installation and Operating Instructions 3-49/64 [95.

Optidrive Applications Support Library

CLOCKAUDIO. MR88 Automatic Microphone Mixer RS232 Programming Version 4.2

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 0

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

SERIES PM172EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

Transcription:

emfis Operation and Instruction Manual vifpe R Y B emfis vifpe MP CL Up Down HPL Electric & Power Pvt. Ltd. 1/21, tma Ram Mansion, saf li Road, New Delhi-110002 Phone : 23234411, 23234811, 23236811; Fax : 23232639 E-Mail : hpl@hplindia.com, Website : www.hplindia.com This document is not contractual, HPL Electric & Power Pvt. Ltd. reserves the right to modify features without prior notice in view of continued improvements. CDNEMFISVIFPE20R4 HPL ELECTRIC & POWER PVT. LTD.

In the CRC 16, the first OCTET Transmitted is LSB: EXMPLE : Development of CRC CRC 16 FLG Contents Initialisation CRC register 1111 1111 1111 1111 of 1st character 0000 0010 1111 1111 1111 1101 Movement 1 0111 1111 1111 1110 1 Flag to 1, Polynome 1010 0000 0000 0001 1111 1111 1111 Movement 2 0110 1111 1111 1111 1 Flag to 1, Polynome 1010 0001 1100 1111 1111 1110 Movement 3 0110 0111 1111 1111 0 Flag to 0 Movement 4 0011 0011 1111 1111 1 1001 0011 1111 1110 Movement 5 0100 1001 1111 1111 0 Movement 6 0010 0100 1111 1111 1 1000 0100 1111 1110 Movement 7 0100 0010 0111 1111 0 Movement 8 0010 0001 0011 1111 1 1000 0001 0011 1110 2nd character 0000 0111 1000 0001 0011 1001 Movement 1 0100 0000 1001 1100 1 1110 0000 1001 1101 Movement 2 0111 0000 0100 1110 1 1101 0000 0100 1111 Movement 3 0110 1000 0010 0111 1 1100 1000 0010 0110 Movement 4 0110 0100 0001 0011 0 Movement 5 0011 0010 0000 1001 1 1001 0010 0000 1000 Movement 6 0100 1001 0000 0100 0 Movement 7 0010 0100 1000 0010 0 Movement 8 0001 0010 0100 0001 0 1. General Information... 2 2. ramming... 4 3. Communication.... 6 Operation and Instruction Manual 12 Operation and Instruction Manual 1

R Y B CL MP Up Down R Y B CL MP Up Down R Y B CL MP Up Down 1. General Information 1.1 Function: This model of with RS485 provides communication facility on RS485 MODBUS. with RS485 works on a master slave configuration, where the is the slave and the master can be computer / PLC etc. The following are also supplied with this model: 2 numbers 120Ω End-Of-Line resistance. Guide to CRC 16 Calculation : n=0 1.2 General Points: For standard configuration, RS 485 serial link 2 wire is used to connect 255 with one RS232 port on the master (computer/plc etc.) over a distance of 1200 meters using MODBUS protocol. 1.3 Typical Network rchitecture: No MOVEMENT TO THE RIGHT CRC 16 CRRY OVER Yes RS 485 RS 232 n=n+1 emfis vifpe emfis vifpe emfis vifpe No n>1 Yes NEXT BYTE Cables and RS485/232 converter, computer are not supplied with this emfis vifpes meter. Recommendation: Please use a shielded twisted pair cable for connection repeater should be used if one intends to exceed the cable distance of over 1200 meters. No MESSGE TERMINTED Yes END Operation and Instruction Manual 2 Operation and Instruction Manual 11

Range and Default Value of ramming Parameter PRMETER RNGE DEFULT VLUE CT Ratio Primary 5-6000 in step of 5 for -/5 500 1-1200 in step of 5 for -/1 Secondary -/1 or -/5 -/5 ave ddress 1-255 5 Baud Rate 4800 / 9600 / 19200 bps 9600 bps Table 1.0 Example : For CT Secondary Writting. ave Function Higher Low Number Number No. of Data CRC CRC ddress code order order of word of word byte High low address address high low 0x0005 0x0010 0x388 0x0001 0x0002 0x0005 0x25E1 3.3 Reset Parameters (Reset to Zero) : Run Hour Power On Hours PRMETER ddress Table Example: For Resetting the RUN HOUR HEX DECIML No. OF DDRESS DDRESS WORDS UNIT RUN HOUR 0x38 906 2 Hour/100 POWER ON HOURS(uxiliary) 0x38C 908 2 Hour/100 ave Function Higher Low Number Number No. of Data CRC CRC ddress code order order of word of word byte High low address address high low 1.4 Connection Diagram: P N L1 L2 L3 N U X RS 485 UX. SUPPLY = 230±30%, ac +RX -RX RS 485 Bus S1 I1 S2 S1 I2 S2 Note: This serial communication requires 120Ω end-of-line resistance to be connected on first and last device in an RS485 MODBUS network. The End Of-Line resistance supplied with is to be connected between Rx- and Rx+ as shown above. 1.5 RS485 configuration : Baud Rate : 4800 / 9600 / 19200 bps Stop Bit : 1 Bytesize : 8Bit Parity : None I3 S1 S2 RS 485/232 Converter End-Of-Line Resistance 120Ω +Rx -Rx RS485 Master 0x0005 0x0010 0x038 0x0001 0x0002 0x007B* 0xEF68 *007B i.e. 1234 is the Default ramming Password Operation and Instruction Manual 10 Operation and Instruction Manual 3

2. ramming To access / view the programming mode: Keys Instruction Display Comment 2.1 Enter the access code '1234 (default password) to access the programming mode: Keys Instruction Display Comment up down up down up down Press Twice Press Thrice up Press Four Time Digit increment by 4. 1234 0--- 1-- - 10-- 12-- 120-123- 1230 1234 You are now in programming mode. Password has to be Entered. Digit increment by 1. Moves one digit right. Digit increment by 2. Moves one digit right. Digit increment by 3. Moves one digit right. To Configure Password. n example has been given using WINBUS32 S/w. Example 1: To read Voltages of R, Y & B Phase. ave Function Higher Low Number Number No. of CRC CRC ddress code order order of word of word byte High low address address high low 0x0005 0x0003 0x0342 0x0003 0x0006 0x41F 3.2 Writing Parameters: Writing Frame ave Function ddress No. Of No. of Data CRC 16 ddress Code Word Bytes Function Code 16: For Writing, Maximum Word Length is 10 words. PRMETER ddress Table HEX DECIML No. OF Unit DDRESS DDRESS WORDS CT RTIO 0x387 903 1 CT SECONDRY 0x388 904 1 1 : Secondary 1 5 : Secondary 5 If your password is correct 1234 (default password) you can see all setting parameters using up/ down button. 2.2 Set ave ddress: Keys Instruction Display 005 Comment Default slave address. Operation and Instruction Manual 4 Operation and Instruction Manual 9

PRMETER HEX DECIML No. OF UNIT DDRESS DDRESS WORDS MXIMUM VLUE Σ PPRENT POWER 0x366 870 1 kv/10 MXIMUM VLUE Σ RECTIVE POWER 0x367 871 1 kvr/10 FREQUENCY 0x368 872 1 Hz/100 CTIVE ENERGY <1000.0 0x369 873 1 kwh/10 CTIVE ENERGY >1000.0 0x36 874 1 RUN ON HOUR <100.00 0x371 881 1 HOUR/100 RUN ON HOUR >100.00 0x372 882 1 POWER ON HOUR <100.00 0x373 883 1 HOUR/100 POWER ON HOUR >100.00 0x374 884 1 CT RTIO 0x387 903 1 CT SECONDRY 0x388 904 1 up down up Press thrice Digit increment by 3. up Press twice 12- down 120 123 2.3 Set Baud Rate (4800/9600/19200) 0-- 1-- 10- Setting a new value. Digit increment by 1. Digit increment by 2. Moves 1 digit to right. Moves 1 digit to right. ave ddress setting completed successfully. Keys Instruction Display Comment Energy&HoursinLong PRMETER HEX DECIML No. OF UNIT DDRESS DDRESS WORDS RUN HOUR 0x389 905 2 Hour/100 up Default Baud Rate. Next. POWER ON HOUR (uxiliary) 0x38B 907 2 Hour/100 up Next. CTIVE ENERGY 0x38D 909 2 kwh/10 up Next. Successfully set New Baud Rate (19200). Operation and Instruction Manual 8 Operation and Instruction Manual 5

3. Communication The MODBUS used by the involves a dialogue using a Master-ave structure. The mode of communication is the RTU (Remote Terminal Unit) using hexadecimal characters of at least 8 bit. 3.1 Reading Parameters The Standard Reading Communication frame consists of Device Function ddress Data CRC16 address Code Function Code 3: For Reading Maximum Word length is 40 words. ddress Table INSTNTNEOUS HEX DECIML No. OF UNIT PRMETER DDRESS DDRESS WORDS SERIL NUMBER_H. 0X340 832 1 SERIL NUMBER_L. 0X341 833 1 R-PHSE TO NEUTRL VOLTGE 0X342 834 1 Volt/10 Y-PHSE TO NEUTRL VOLTGE 0X343 835 1 Volt/10 B-PHSE TO NEUTRL VOLTGE 0x344 836 1 Volt/10 PHSE TO PHSE VOLTGE (R-Y) 0x345 837 1 Volt/10 PHSE TO PHSE VOLTGE (Y-B) 0x346 838 1 Volt/10 PHSE TO PHSE VOLTGE (B-R) 0x347 839 1 Volt/10 R-PHSE CURRENT 0x348 840 1 mp/10 Y-PHSE CURRENT 0x349 841 1 mp/10 B-PHSE CURRENT 0x34 842 1 mp/10 R-PHSE VERGE CURRENT 0x34B 843 1 mp/10 Y-PHSE VERGE CURRENT 0x34C 844 1 mp/10 B-PHSE VERGE CURRENT 0x34D 845 1 mp/10 Operation and Instruction Manual 6 PRMETER HEX DECIML No. OF UNIT DDRESS DDRESS WORDS R-PHSE MXIMUM CURRENT 0x34E 846 1 mp/10 Y-PHSE MXIMUM CURRENT 0x34F 847 1 mp/10 B-PHSE MXIMUM CURRENT 0x350 848 1 mp/10 TOTL CURRENT 0x351 849 1 mp CTIVE POWER (R-PHSE ) 0x352 850 1 kw/10 CTIVE POWER (Y-PHSE) 0x353 851 1 kw/10 CTIVE POWER (B-PHSE) 0x354 852 1 kw/10 PPRENT POWER (R-PHSE ) 0x355 853 1 kv/10 PPRENT POWER (Y-PHSE) 0x356 854 1 KV/10 PPRENT POWER (B-PHSE) 0x357 855 1 kv/10 RECTIVE POWER (R-PHSE ) 0x358 856 1 kvr/10 RECTIVE POWER (Y-PHSE) 0x359 857 1 KVR/10 RECTIVE POWER (B-PHSE) 0x35 858 1 KVR/10 POWER FCTOR (R-PHSE) 0x35B 859 1.01 POWER FCTOR (Y-PHSE) 0x35C 860 1.01 POWER FCTOR (B-PHSE) 0x35D 861 1.01 SYSTEM POWER FCTOR 0x35E 862 1.01 Σ CTIVE POWER 0x35F 863 1 kw/10 Σ PPRENT POWER 0x360 864 1 kv/10 Σ RECTIVE POWER 0x361 865 1 kvr/10 VERGE VLUE Σ CTIVE POWER 0x362 866 1 kw/10 VERGE VLUE Σ PPRENT POWER 0x363 867 1 kv/10 VERGE VLUE Σ RECTIVE POWER 0x364 868 1 kvr/10 MXIMUM VLUE Σ CTIVE POWER 0x365 869 1 kw/10 Operation and Instruction Manual 7