User s Manual. Models /436102/436103/436104/ µr10000 Recorder Portable Type. IM 04P01B01-51E 1st Edition. Yokogawa Electric Corporation

Similar documents
User s Manual. Models /437102/437103/437104/ /437112/437118/437124/ µr20000 Recorder Portable Type. IM 04P02B01-51E 1st Edition

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112

Operation Guide Models /436102/436103/436104/ µr10000 Recorder

VC200 Mobile Phone Tester Please Read before Use

User s Manual. Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

User s Manual Power Supply IM E. 5th Edition

MFT Remote Controller

PR Series Paperless Recorders

XL112, XL114 ポータブルデータロガ

DAQSTATION DX100P/DX200P

Customer Maintenance Parts List

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

User s Manual Models MV2008/MV2010/MV2020/MV2030/ MV2040/MV2048 MV2000 First Step Guide

User s Manual DAQSTATION DX200. Model DX204/DX208/DX210/DX220/DX230. IM 04L02A01-01E 6th Edition. Yokogawa Electric Corporation

Product Documentation

RADCOM s Platform Specifications. Valid from Version 7.10

VC3300 Wireless Communication Tester Please Read before Use

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 Operation Guide

User s Manual DAQSTATION DX100P. Model DX102P/DX104P/DX106P/DX112P. IM 04L05A01-01E 4th Edition. Yokogawa Electric Corporation

General Specifications

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Portable Paperless Recorder MV1000/MV2000

Advanced Test Equipment Rentals ATEC (2832)

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Enhanced Mini-Chansim Model VCS-232

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

RD2000, 5.6" display. All models shown smaller than actual size.

INTELLIGENT SERVER. Model: BMS-LSV6E

User s Manual DAQSTATION DX200P. Model DX204P/DX208P/ DX210P/DX220P/DX230P. IM 04L06A01-01E 5th Edition. Yokogawa Electric Corporation

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

Digital Manometer. IM E 2nd Edition

Daqstation DXAdvanced DX1000/DX2000 DX1000/DX2000. Bulletin 04L41B01-01E.

User s Manual Models FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 First Step Guide

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

Industrial Recorders

AQ2200 Series Multi-Application Test System Remote Viewer

MW100 Data Acquisition Unit

MC 11 EB-2 Power supply cabinet with external bus, AC version

POWERCERT PC parameter setting tool (For the PR300, UPM100, and UPM101)

Model VC-SHIELD Shield Box

±15 V Current-Limited Power Supply

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

User s Manual Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

Interface Conversion Adaptor (DVI to LVDS) IA-573-A. User s Manual. Ver.1.02

High Power over Ethernet Midspans PD Port Model PD Port Model

DX1000/DX2000. Bulletin 04L41B01-01E.

Industrial Recorders. Bulletin 04P01B01-01E

Time Inter val Analyzer

Agilent 70612B K18 Switch Matrix

APC Next Generation Rack ATS

General Specifications

ASCO 920 Remote Control (RC) Switches

User s Manual Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

MODEL 805 USER MANUAL

Dell MD1280 Storage Enclosure Getting Started Guide

Daqstation DXAdvanced DX1000/DX2000. Bulletin 04L41B01-01E.

General Specifications

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

User s Manual Model FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 Paperless Recorder First Step Guide

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

SNAP-IT-1U Installation Guide

920 Remote Control (RC) Switches

General Specifications

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

User s Manual. AQ6150/AQ6151 Optical Wavelength Meter Getting Started Guide IM AQ EN. 1st Edition

Disclaimer. Note that the Midspan is designed for indoor use only.

ALLEN BRADLEY RELAY Bulletin 700-HF

Line Impedance Stabilization Network (LISN)

Multi-batch Function (/BT)

User s Manual Model /436102/436103/436104/436106/ /437102/437103/437104/437106/ /437118/437124

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

PR series User Manual

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Network Camera. Installation Manual Before operating the unit, please read this manual thoroughly and retain it for future reference.

Sartorius Research. R 160 P Electronic Semi-Microbalance

Operation Guide MX100 Data Acquisition Unit

General Specifications

Please Read This First. Userʼs Manual. Data Acquisition System GM. First Step Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

OBIS LX/LS 6-Laser Remote

iologik 4000 Series (M) Modules

SX 6000 Paperless Recorder

General Specifications

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Solar Combiner Enclosure

PTU300 Combined Pressure, Humidity and Temperature Transmitter

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

EMC1600 Series Media Converter and Ethernet Extender Chassis

MW100 Data Acquisition Unit

Transcription:

User s Manual Models 436101/436102/436103/436104/436106 µr10000 Recorder Portable Type * 4 P 1 B 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition

Foreword Notes Trademarks Revisions Thank you for purchasing the µr10000 (hereafter referred to as recorder). This user s manual contains information about the recorder with the /H5x option specification (the portable type). Please also refer to the user s manual for the standard version of the recorder (IM04P01B01-01E) when operating this model. The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument s performance and functions. Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact your nearest YOKOGAWA dealer. Copying or reproduction of all or any part of the contents of this manual without the permission of Yokogawa Electric Corporation is strictly prohibited. All the brands or names of Yokogawa Electric s products used in this manual are either trademarks or registered trademarks of Yokogawa Electric Corporation. Adobe, Acrobat, and PostScript are trademarks of Adobe Systems Incorporated. The company and product names used in this manual are not accompanied by the trademark or registered trademark symbols ( and ). Company and product names used in this manual are trademarks or registered trademarks of their respective holders. 1st Edition February 2006 1st Edition: February 2006 (YK) All Rights Reserved, Copyright 2006 Yokogawa Electric Corporation 1

Safety Precautions The following describes warnings that are specific to the portable type. Please also refer to pages iii and iv of IM04P01B01-01E for warnings that apply to all models of the recorder. WARNING Power Supply Before connecting the power cord, ensure that the power supply voltage matches the voltage rating for the instrument, and that it is within the maximum rated voltage for the power cord itself. Use the Correct Power Cord and Plug The main power plug can only be plugged into an outlet with a protective grounding terminal. Do not disable the protection feature of the instrument by using an extension cord without protective grounding. Connect the Protective Grounding Terminal Make sure to connect the protective grounding to prevent electric shock before turning ON the power. The power cord included with the portable type is a 3- prong cord with a grounding wire. Connect the power cord to a 3-prong AC outlet with a protective grounding terminal. 2

R Checking the Contents of the Package Unpack the box and check the contents before operating the software. If some items are missing or otherwise inconsistent with the contents description, please contact your dealer or nearest YOKOGAWA dealer. Checking the Model Name Check the name plate on the recorder to ensure that the model name and suffix code match the ones you ordered. MODEL SUFFIX RECORDER STYLE SUPPLY C US 172608 TAG NO. MODEL SUFFIX SUPPLY RECORDER STYLE FREQUENCY NO. FREQUENCY NO. N200 Made in China Made in China Model and Suffix Codes Model 436101 Suffix Code Optional Code 436102 436103 436104 436106-1 -2-3 Description µr10000 1 pen recorder µr10000 2 pen recorder µr10000 3 pen recorder µr10000 4 pen recorder µr10000 6 dot recorder Japanese English/German/French & deg F / DST Chinese & deg F / DST /A1 Alarm output relay 2 points 1 /A2 Alarm output relay 4 points 1 /A3 Alarm output relay 6 points 1, 2 /C3 RS-422A/485 interface 3 /C7 Ethernet (10BASE-T) interface 3 /F1 Fail/Chart end detection and output 2 /H2 Clamped input terminal 4 /H3 Non-glare door glass /H5D Portable type Power cord UL, CSA st'd 7 /H5F Portable type Power cord VDE st'd 7 /H5R Portable type Power cord AS st'd 7 /H5J Portable type Power cord BS st'd 7 /H5H Portable type Power cord GB st'd 7 /M1 Mathematical function /N1 Cu10, Cu25 RTD input /N2 3 legs isolated RTD 4, 5 /N3 Expansion inputs 6 /P1 24 VDC/AC power supply 7 /R1 Remote control 5 points /CC1 Calibration Correction 1 /A1, /A2, and /A3 cannot be specified simultaneously. 2 /A3 and /F1 cannot be specified simultaneously. 3 /C3 and /C7 cannot be specified simultaneously. 4 /H2 and /N2 cannot be specified simultaneously. 5 Valid only on the model 436106. 6 14 types of input including Pt50 RTD, PR40-20, and Platinel TC 7 /H5x and /P1 cannot be specified simultaneously. 3

Checking the Contents of the Package Standard Accessories Power cord /H5D /H5F /H5R /H5J /H5H One of these power cord types is supplied according to the instrument s suffix code Part Number Q ty Note A1006WD 1 Provided when /H5D is specified for the optional code. Maximum rated power voltage: 125V A1009WD 1 Provided when /H5F is specified for the optional code. Maximum rated power voltage: 250V A1024WD 1 Provided when /H5R is specified for the optional code. Maximum rated power voltage: 250V A1023WD 1 Provided when /H5J is specified for the optional code. Maximum rated power voltage: 250V A1064WD 1 Provided when /H5H is specified for the optional code. Maximum rated power voltage: 250V For information on standard accessories besides the power cord and optional accessories (sold separately), see page vi of the user s manual, IM04L01B01-01E. 4

Installation and Connecting the Power Supply Installation The following describes warnings that are specific to the portable type. For all other details regarding installation, see section 2.2 of IM04L01B01-01E, Installation. Precautions Regarding the Installation Location The portable type is not equipped to be installed in an instrumentation panel. For the portable type, we recommend that you maintain a 50 mm or greater margin of space around the front, back, sides, and top of the instrument. This instrument is for indoor use only. Do not use the instrument outdoors. Connecting the Power Supply Points to Note When Connecting the Power Supply Please heed the following warnings when connecting the power supply to the instrument. Failure to heed the following warnings may result in electric shock or damage to instruments. WARNING Ensure that the source voltage matches the rated power supply voltage of the instrument before connecting the power cord. Check that the power switch to the instrument is turned OFF before connecting the power cord. Make sure to connect protective earth grounding to prevent electric shock. Connect the power cord of the portable type to a three-prong power outlet equipped with a protective earth terminal. Do not use an extension cord that does not have a protective grounding wire. The protective features of the instrument will be rendered ineffective. Use a power supply that meets the conditions indicated below. Item Condition Rated supply voltage 100 to 240 VAC Supply voltage range used 90 to 132, 180 to 264 VAC Rated supply voltage frequency 50/60 Hz Permitted supply voltage frequency range 50/60 Hz ±2% Maximum power consumption Pen model: 40 VA, dot model: 40 VA Note Do not use a supply voltage in the range 132 to 180 VAC, as this may have adverse effects on the measurement accuracy. 5

40VA MAX Installation and Connecting the Power Supply Connections 1. Check that the power switch to the instrument is turned OFF. 2. Connect the plug on the accessory power cord to the power supply connector on the rear panel. 100-240V~ 50/60Hz 3. Ensure that the power outlet to be used meets the conditions on the previous page and that the voltage of the power supply is within the maximum voltage rating of the power cord, then connect the other end of the power cord to the power supply outlet. The AC outlet must be of a three-prong type with a protective earth ground terminal. 6

R Names of Parts The following describes only the names of parts that are specific to the portable type. For all other part names, see section 3.1 of IM04P01B01-01E, Names of Parts and Functions. 1 100-240V~ 50/60Hz 40VA MAX TAG NO. RECORDER STYLE N200 C US 172608 MODEL SUFFIX SUPPLY FREQUENCY NO. Made in China Rear Panel 1. Carrying handle 2. Protective ground terminal (spare) 3. Power terminal with protective ground terminal (attach the specified power cord) 4. Feet (four) 2 3 4 7

R Specifications and Dimensional Drawings Specifications The following describes specifications that are specific to the portable type. For other specifications, see chapter 12 of IM04P01B01-01E, Specifications. Dimensional Drawings Portable Type (/H5x) Carrying handle The x in /H5x designates the power cord specification. D: Power cord (UL and CSA compliant) F: Power cord (VDE compliant) R: Power cord (SAA compliant) J: Power cord (BS compliant) H: Power cord (GB compliant) 138.5 (5.45) Unit: mm (approx. inch) Unless otherwise specified, tolerance is ±3% (however, tolerance is ±0.3 mm when below 10 mm). 100-240V~ 50/60Hz 40VA MAX 144 (5.67) 27.5 (1.08) 285 (11.2) 176 (6.93) 81.5 (3.21) 144 (5.67) C US 172608 TAG NO. MODEL SUFFIX SUPPLY RECORDER STYLE 141.5 (5.57) 12.4 (0.49) 187 (7.36) FREQUENCY N200 NO. Made in China 8