Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

Similar documents
Instruction Manual HPH-8

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 (pg. 6) Flat; Corner (pg. 5) Wire Size PERFORMANCE

ICS Entrance Management Sign Installation Guide. Version 1.0

Satellite INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

QuantumR Light Management Hub (QP2)

Single Phase Systems-North American PC125/PC420 Series

CS XL XM. EcoSystem Bus Supply

QuantumR Light Management Hub

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 Flat; Corner Wire Size PERFORMANCE. Field of View CRI Lumen Maintenance Binning Tolerance Warranty + +

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

CAUTION READ CAREFULLY

MAJOR VA Power Inverter

920 Remote Control (RC) Switches

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

SECTION SWITCHBOARDS

TALON Network Manager- 2 & 6 Express

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Control different load types with one device

ASCO 920 Remote Control (RC) Switches

Control different load types with one device

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Premium Online Series

TILE Interior TILE Tunable White LINE

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Scout Select System White

TAC I/NETTM 1284, 1280, Security Control Unit

TRC-190 User s Manual

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Model DMX24DIM Installation and Operations Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

LANDSCAPE TRANSFORMERS

PANELITE ENCLOSURE LIGHTS OVERVIEW

High Power over Ethernet Midspans PD Port Model PD Port Model

PowerLogic High Density Metering System 1-Meter Enclosure

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

Multi-Point Gas Detection and Control System

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

General-Purpose Photoelectric Sensor

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

Temperature. Power requirements. Weight. Dimensions

10/100/1000TxBase-T(X) P.D. input port and two 10/100/1000TxBase-T(X) P.S.E. output ports, the device not only pass on

Avanti HP Series Centrifuges Preinstallation

Three Phase Systems-International PC302-I/MTD

C-Bus Interface Devices for wider control of a home or building.

Specifications, Installation, and Operating Instructions

ORB TM 4-20 ma Input Box Installation & Operation Manual

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

TRC-190 User s Manual

INJ-24A Series Quick Installation Guide

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

Switched Relay Controller - Relay Panel with Breakers

ecna-5 D-Cinema Automation System

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Transceiver Hub with Integral Camera Power

Electrical Demand Specification (Reference SOP: )

SAVE THESE INSTRUCTIONS

Series Amp Pad Mount Quick Connect Input and Output Power Panels

PowerFlex 400 AC Drive Guide Specification

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Installation and Hardware Guide

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

onlinecomponents.com

iconverter 2-Module Power Chassis

XBR V4 INSTALLATION AND USER GUIDE

Model DMX8DIM Installation and Operations Manual

PROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:

PV Rapid Shutdown device

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Multi-Point Gas Detection and Control System

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

SECTION ( ) LIGHTING CONTROL PANELBOARD


SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Active UTP Transceiver Hub with Integral Isolated Camera Power

MOXA EtherDevice Switch & PoE Splitter

Multi-Point Gas Detection and Control System

System Installation guide

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

PT-7728/7828 Quick Installation Guide

Transcription:

DCP-A Panel Network DALI Control Panel for DALI Ballast, DALI Relays and DALI Dimmers 24 20 6 The DCP-A electronic network control panel with Clipsal DCDALCIP250-2 serial interfaces supports applications requiring multiple DALI communication buses. The wall mount enclosure is available with up to 4 DALI lines interfaces supporting a maximum of 256 DALI Ballasts, DALI Relays or DALI 120V Dimmers. Additional space is provided in the panel for mounting an optional Clipsal DCB2-1608 Ethernet-to-Serial RTC controllers or LAN to RS-232 multi-port serial hub. Control and monitor multiple DALI communication buses Equipped for Digital two-way communications with RS-232 serial devices. LAN communication requires optional interface Easily adds additional DALI buses to existing systems Field-expandable (for up to 4 DALI buses) Convenient 120 V electrical outlet for powering optional LAN interface Optional 120 VAC outlet Optional additional 24V DC Transformer for driving external 24V occupancy sensors Approved for Class 1 and Class 2 DALI control wiring installations 5-port 10/100Mb Ethernet Switch UL508-A NEMA-1 wall mount enclosure with hinged door Safety: ETL UL916, CSA C22.2 No. 205 1 year warranty Order Description Panel Voltage Panel Watts * DALI bus Maximum number of DALI Number VAC W support addressable devices (ballast) SLS-DCP-A-2 DCP-A-w/ 1 DALI Lines 120 500 2 128 SLS-DCP-A-4 DCP-A-w/ 4 DALI Lines 120 500 4 256 Each loop can be loaded up to a maximum of 220 ma nominal at 15VDC. Accessories Order Description Wattage Input Voltage Output Voltage Number BM-2600 DALI Ethernet/Serial Controller w/rtc, 2 RS-232 ports, 1 RJ45, 16 inputs <1W 24V DC - NP-5410 DALI-MX LAN 4xRS232 Moxa LAN interface with 4 RS-232 ports <1W 24V DC - DR30-12 MEANWELL DR30 Transformer. 120VAC input, 30W @12VDC output 30 W 120V AC 12V DC DR60-24 MEANWELL DR60 Transformer. 120VAC input, 60W @24VDC output 60 W 120V AC 24V DC

Mounting and Environment The electronic network control panel is designed for wall mounting. Panel should be installed in an electrical or mechanical equipment room. The unit should be mounted a minimum of 6 inches away from any other enclosure. Panel should not be exposed to the weather or used in an environment where humidity is condensing on it. Mount enclosure with door hinge on the left side. Verify that a minimum door swing clearance of 28 inches is provided. Panel Wiring Class 1 5-wire in conduit DALI wires 600V 120/277 VAC DALI Bus Connections The enclosure requires connection of 120VAC for the duplex receptacles. Receptacles are intended for powering the Busmaster interfaces and optional communication interface. Receptacles are not intended to power other equipment. Refer to table for power loading requirement. Class 2 The cavity in the middle of the enclosure is designed to house an optional interface to convert LAN Ethernet communications to serial RS-232. DALI bus wiring can be installed as either a Class 1 or Class 2 installation (reference drawings). Class 1 installation: Wiring for DALI Bus and AC load wiring in same conduit. Class 2 installation with the DALI bus wiring separated from AC load wiring. The DALI CONTROL PANEL is a complete DALI head-end panel enclosing CLIPSAL DCBM2-1608 intelligent real-time-clock schedulers, DALI (220 ma) power supplies plus DALI Serial interfaces, to support up to 4 DALI loops. Via the building Ethernet, the panels are connected to both individual users & administrators both building level overrides, automated sweeps and individual user level control of their assigned fixtures. D A L I C O N T R O L P A N E L 120/277 VAC DALI Bus

24V DC Device Layout and Conduit Access 120V AC Into panel DALI Out to Loop 120V 15 Amp Circuit Breaker 120V Distribution 24V Transformer Clipsal DCBM2-1802 DALI Controller 120V Socket Clipsal DCDAL- CIP250-2 24V Distribution 5-Port Ethernet Switch Ethernet DALI to Relay Panel Scale 4:1 Low Voltage Switches

DCBM2-1608 DALI Control Panel DCP-A DCBM2-1608 DALI CONTROL PANEL A WIRING DETAILS 120 VAC CIRCUIT BREAKER DALI CONTROL PANEL A 120VAC DISTRIBUTION 24V DC CLASS 1 CLIPSAL DCDAL- CIP250-2 DALI POWER SUP- PLIES AND SE- RIAL I/F 24VDC DISTRIBUTION ETHERNET SWITCH CLASS 2 ETHERNET DALI DALI LOOPS 1-4

Installation Instructions: When installing enclosure and making electrical connections it is important to follow all codes applicable to lighting control equipment. 1) See enclosure drawing for additional support information. 2) Locate area on wall to mount enclosure. 1. Panel dimension is (DCP-A) 24"x20"x6" with hinge door on left side. 2. Panel dimension is (DCP-B) 36"x24"x6" with hinge door on left side. 3) It is recommended that a minimum space of 8 inches is available between enclosure and other object (wall or other enclosure). 4) Position the enclosure with the door hinge on the left side. Fasten enclosure to wall using mounting holes located at each corner of the back enclosure. 5) Route all power (120V classified as Class One wiring) to the left side top of the enclosure that contains the circuit breaker. a. Feed 120VAC into the Class One wiring compartment. Connect 120VAC power to circuit breaker within enclosure according to National and Local Electrical Codes. i) Torque 120V Hot and Neutral Terminals to 21 lb-in ii) Torque Ground Terminal to 14 lb-in b. Identify DALI loops and connect them to the terminal blocks provided on each BusMaster. (Caution - DO NOT CONNECT 120VAC to the DALI terminal blocks) 6) Route the computer interface cable into the right side of the enclosure (classified as Class 2 wiring). a. Verify the proper computer interface is installed into the compartment on the right side of the enclosure. b. Verify the serial communication cables between the network interface and the BusMaster(s) are in place. 7) Connect network interface cable to the communications adaptor located in the compartment. 8) Check all wiring to make sure there are no loose connections. Make sure the enclosure is properly grounded (per code requirements). 9) Close enclosure door after completing the installation and wiring. Operation checklist: 1. Verify that 120VAC power is available to the outlets located in the enclosure. 2. Check that the green power LEDs on all AC/DC Transformers are illuminated. 3. Check that the green power LEDs on each BusMaster is illuminated. 4. Make sure that the power indicator of the Ethernet switch is illuminated. 5. Make sure that the power indicator of the computer interface (Moxa or BM2600) is illuminated. 6. To check enclosure functionally, refer to system operating and commissioning guides.

Dimensions Dimensions In inches