Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

Similar documents
GROUND FAULT CIRCUIT INTERUPTERS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Why is my AFCI tripping?

Presentation Title ( Arial, Font size 28 ) Electrical Safety at Office

Entry Level Assessment Blueprint Electrical Occupations

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,

Electrical Components and Equipment for General Use Self Inspection Checklist

SureTest Model ST 1D Instructions

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

powerbrite led Lighting Systems & Modules

ATD Watt Fluorescent Underhood Light Owner s Manual

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS

110.4 Use of Equipment.

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

EMS Electrical Management System

Primary Injection Test Procedure

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Progressive Industries, Inc. EMS Electrical Management System

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

ft Aspen Fir Item # Commercial ITEM Lights

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

LITE TUNES #V

ATD SABER 2000 LUMENS CORDED UNDERHOOD LIGHT OWNER S MANUAL

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)


Source-Transfer Application Guide

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

EMS Electrical Management System

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Pulse LED Instruction Guide

Panduit Basic Rack PDU

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Autoranging True RMS Multimeter User Manual

EMS-PT30X & EMS-PT50X

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

The Different Types of AC Power Connectors in North America

THE CTB08D LIGHT CONTOLLER

PR3400 Series 1.4Mp USB Cameras Hardware Guide

EC Series. Safety Guide

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X

SUMMARY: The Consumer Product Safety Commission ( CPSC or Commission ) is issuing a

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

Model HM-535 Power Supply Installation and Service Instructions

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Conveyor Belt Alignment Switches from IDEM

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Emery County Senior Center Green River 06/07

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SAVE THESE INSTRUCTIONS

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

ESD CONTROL SURVEY - REPORT

Latex 110 Printer. Site preparation guide

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

Blueprint Drawings & Wiring Diagrams. for branch circuits

Panduit Basic Rack PDU with Local Meter

OSHA Top Ten: and a closer look. Steven L. Browning Safety and Health Compliance Officer Cleveland OSHA Office

SECTION PANELBOARDS

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Document C0. Use for:

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Please use the Q & A utility to ask us any questions concerning the material being presented.

GFCIs. GFCIs. GFCIs. IN OUR LINE OF THERE S BEEN A SURGE. Woodhead now offers a complete PERFORMANCE I RELIABILITY I SAFETY GFCI. line Woodhead LINE

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

DCM Digital Control Modules

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Power Supply and Fan Module Installation

* * Agilent Power Distribution Unit (PDU) Installation Guide

CONTENTS 3 EN :2006

MELTRIC Corporation. The best in industrial wiring devices. Product Technology & Safety. Value

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

TDM-170 TIMER DISPLAY

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

2008 Code Changes for Power Distribution

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Fall Test 21 due 12/11/2012

DTC P0AA6 - High Voltage Isolation Fault

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

Transcription:

Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI) GROUND FAULT CIRCUIT INTERRUPTERS Wiring design and protection. - 1926.404 Our company uses ground fault circuit interrupters. A ground fault circuit interrupter (GFCI) provides protection for all 120-volt, 15-, 20-, and 30-ampere receptacle outlets that are not a part of the permanent wiring by detecting lost current resulting from a short, overheating, and/or ground fault. It should be noted that an extension cord into which electrical devices are plugged are not part of the permanent wiring; therefore, GFCI's are required. A GFCI will "trip" when the amount of current amperes going to an electrical device in the hot conductor and the amount of current returning from an electrical device differs by approximately 5 milliamps. The GFCI can interrupt the current within as little as 1/40th of a second. The current that is missing is being lost through a ground fault, whether it is in the actual grounding, a short in the equipment or electricity going through the employee to the ground. A GFCI will not protect an employee who comes in contact with two hot wires or a hot wire and a neutral wire. A GFCI will provide protection against fires, overheating, damage to insulation, and, the most common form of electrical shock hazard -- the ground fault. GFCI s must be tested before use. In the event that we are performing work in a chemical plant or some other type of facility where a grounding conductor program is required we will use the program on the following pages. 1 of 5

Assured Equipment Grounding Conductor Program 29 CFR 1926.404 Per paragraph (b)(1)(i), 29 CFR 1926.404, Wiring Design and Protection, ground fault protection for our employees will be provided by the use of ground fault circuit interrupters or an Assured Equipment Grounding Conductor Program. As a general rule, the use ground fault circuit interrupters is sufficient for employee protection. However, if we are working within a facility that requires the use of an Assured Equipment Grounding Conductor Program or if the client requires an Assured Equipment Grounding Conductor Program, the following applies. The provisions of our Assured Equipment Grounding Conductor Program cover all cord sets, receptacles which are not a part of a building or structure, and equipment which is connected by cord and plug for use, or used by, our employees on our construction sites. These procedures and guidelines are designed to eliminate all injuries resulting from possible malfunctions, improper grounding and/or defective electrical tools. A copy of this program will be maintained at all job sites where it is in use and it will be available for review by affected employees as well as inspection and copying by authorized representatives of OSHA. At least one competent person (one who by virtue of training or experience is capable of identifying existing and predictable hazards as they relate to electrical safety and has the authorization to take prompt corrective measures to eliminate them) will be designated to implement our program and be responsible for the program execution. This person or persons will be identified on our Job Site Form, Designation of Competent Persons, found in our Project Manual. The designated competent person(s) will ensure that: a. each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug [except cord sets and receptacles which are fixed and not exposed to damage] are visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective will be disposed of or be tagged out of service and not used until repaired. b. the following tests are performed on all cord sets, receptacles which are not a part of the permanent wiring of the building or structure, and cord- and plug-connected equipment required to be grounded: 2 of 5

i all equipment grounding conductors will be tested for continuity. Equipment grounding conductors must be electrically continuous. ii each receptacle and attachment cap or plug will be tested for correct attachment of the equipment grounding conductor. The equipment grounding conductor must be connected to its proper terminal. c. the above tests will be performed: i before first use; ii before equipment is returned to service following any repairs; iii before equipment is used after any incident which can be reasonably suspected to have caused damage (for example, when a cord set is run over); and iv at intervals not to exceed 3 months, except that cord sets and receptacles which are fixed and not exposed to damage will be tested at intervals not exceeding 6 months. Employees are not permitted to use any equipment which falls within the scope of this program which has not passed the above tests and inspections noted in paragraphs a., b., and c., above. Faulty equipment will be immediately discarded or tagged as faulty and immediately sent for repair. The above tests and inspections must be recorded. The test record will identify each receptacle, cord set, and cord- and plug-connected equipment that passed the test and shall indicate the last date it was tested or the interval for which it was tested. The test record will be kept by logs, color coding, or other effective means. Only the latest log must be available at the job site for inspection and review by affected employees or OSHA representatives. Previous logs may be destroyed. While a written log identifying the equipment and the test date is acceptable, using colored electrical tape on cords, receptacles and equipment indicating the time period of the tests might be easier to accomplish and less confusing. The competent person will ensure that outlet devices have an ampere rating not less than the load to be served and that they comply with the following: a. Single receptacles: a single receptacle installed on an individual branch circuit shall have an ampere rating of not less than that of the branch circuit. 3 of 5

b Two or more receptacles: where connected to a branch circuit supplying two or more receptacles or outlets, receptacle ratings shall conform to the values listed in below table. c. Receptacles used for the connection of motors: the rating of an attachment plug or receptacle used for cord- and plugconnection of a motor to a branch circuit will not exceed 15 amperes at 125 volts or 10 amperes at 250 volts if individual overload protection is omitted. TABLE: Receptacle Ratings for Various Size Circuits Circuit rating amperes Receptacle rating amperes 15 Not over 15 20 15 or 20 30 30 40 40 or 50 50 50 4 of 5

Assured Equipment Grounding Conductor Test Log A [Use Test Log A or B and retain most current log] Page of Reference 1926.404(b)(iii)(G). As of,, (time) (date) All equipment grounding conductors identified by (color of tape or other means) have been tested for continuity and are electrically continuous. Additionally, all receptacles and attachment caps or plugs [identified by the same color tape or other means] have been tested for correct attachment of the equipment grounding conductor and the grounding conductor is connected to its proper terminal. Note: If color coding is used, previous and subsequent tests will use a different color code. (Competent Person Signature) (Date) Test for continuity and electrically continuous Test Log B [Use Test Log A or B and retain most current log] Fail and removed Pass from Svc (Equipment Grounding Conductor Identity) Test for receptacle and attachment cap or plug for correct attachment of equipment grounding conductor Note: The equipment grounding conductor must be connected to its proper terminal. (Receptacle & attachment cap or plug & equipment identity) (Competent Person Signature) (Date) 5 of 5