COMMUNICATION CONVERTER FOR PROFIBUS

Similar documents
INSTRUCTION MANUAL FOR PC LINK UNIT CLT-20S

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Conductive Level Controller

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Operating instructions. Speed monitor D / / 2014

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module

Operating instructions. Switching amplifier DN0210 DN / / 2015

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Classification Enclosure rating Input voltage Type of

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

1. Safety Precautions (Read these precautions before use.)

DIGITAL TRANSMITTER PROFIBUS Interface OPT-563B-70. Instruction Manual EN B

Three-phase Phase-sequence Phase-loss Relay

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

User s Manual Power Supply IM E. 5th Edition

RM699B miniature relays

NIR Moisture Analyzer KB-30

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

RS232C/RS485 Data can be easily monitored by LAN

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

Solid-state Timer H3YN

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

RM84 miniature relays

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

2016 SIGLENT TECHNOLOGIES CO.,LTD

Thermal-Magnetic Circuit Breaker 2216-S

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E

QUINT-BUFFER/24DC/24DC/40

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

7032 Digital-Analog Multimeter

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Sensing method Appearance Connection method Sensing distance Output Model. M12 connector 10±3 mm. Size Type Appearance Cable length Model Straight

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

Single-phase Voltage Relay

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Magnetic and Hydraulic-Magnetic Circuit Breaker

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Cable specifications PVC

Model 2380 Rack-Mount Kit

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

E2K-X4ME1 2M E2K-X4ME2 2M

Preface. Essential Safety Precautions

GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

MIC-2 MKII Profibus module user s manual

RUC-M industrial relays for DC loads

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

EX-RC1 Remote I/O Adapter

One step ahead in performance and mounting ease

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

Model 2380 Rack-Mount Kit

TOS-SN-1 Extended Panel Operation Manual

RUC industrial relays of small dimensions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

TETRIS 2500 High Impedance Active Probe. Instruction Manual

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

RUC industrial relays of small dimensions

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PS345XA-HD40 Installation Guide. About the Manual. Safety Cautions. URL

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

XTM1250SA DIN rail three phase four wire LCD display energy meter

H3CA-8H-AC/100/110/120

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

series USER S MANUAL MICREX-F Personal Computer Loader Adapter <Type:FLT-ASFKA >

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

ELV12 Series. Instruction Manual

Package Contents. GP Options (Made by Digital)

Cylindrical Proximity Sensor

Mini Photoelectric Sensor

Transcription:

INSTRUCTION MANUAL COMMUNICATION CONVERTER FOR PROFIBUS IFP-100 No.IFP11E3 2012.01 Preface Thank you for purchasing our IFP-100, Communication Converter for PROFIBUS. This manual contains instructions for the mounting, functions, operations and notes for operating the IFP-100. To ensure safe and correct use, thoroughly read and understand this manual before using this instrument. To prevent accidents arising from the misuse of this unit, please ensure the operator receives this manual. Notes This instrument should be used in accordance with the specifications described in the manual. If it is not used according to the specifications, it may malfunction or cause a fire. Be sure to follow the warnings, cautions and notices. If they are not observed, serious injury or malfunction may occur. Specifications and the contents of this instruction manual are subject to change without notice. Care has been taken to ensure that the contents of this instruction manual are correct, but if there are any doubts, mistakes or questions, please inform our sales department. This instrument is designed to be installed on a DIN rail within a control panel. If it is not, measures must be taken to ensure that power terminals or other high voltage sections cannot be touched. Any unauthorized transfer or copying of this document, in part or in whole, is prohibited. Shinko Technos CO., LTD. is not liable for any damage or secondary damage(s) incurred as a result of using this product, including any indirect damages. Safety Precautions (Be sure to read these precautions before using our products.) The safety precautions are classified into two categories: Warning and Caution. Depending on the circumstances, procedures indicated by Caution may cause serious results, so be sure to follow the directions for correct usage. Warning Caution Procedures which may lead to dangerous conditions and cause death or serious injury, if not carried out properly. Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or damage the product, if not carried out properly. Warning To prevent an electric shock or fire, only Shinko or other qualified service personnel may handle the inner assembly. To prevent an electric shock, fire or damage to the instrument, parts replacement may only be undertaken by Shinko or other qualified service personnel. Safety Precautions To ensure safe and correct use, thoroughly read and understand this manual before using this instrument. This instrument is intended to be used for industrial machinery, machine tools and measuring equipment. Verify correct usage after purpose-of-use consultation with our agency or main office. (Never use this instrument for medical purposes with which human lives are involved.) External protection devices such as protection equipment against excessive temperature rise, etc. must be installed, as malfunction of this product could result in serious damage to the system or injury to personnel. Also proper periodic maintenance is required. This instrument must be used under the conditions and environment described in this manual. Shinko Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to the instrument being used under conditions not otherwise stated in this manual. Caution with respect to Export Trade Control Ordinance To avoid this instrument from being used as a component in, or as being utilized in the manufacture of weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the end users and the final use of this instrument. In the case of resale, ensure that this instrument is not illegally exported.

1. Installation Precautions Caution This unit is intended to be used under the following environmental conditions (IEC61010-1): Overvoltage category, Pollution degree 2 Ensure the mounting location corresponds to the following conditions: A minimum of dust, and an absence of corrosive gases No flammable, explosive gases No mechanical vibrations or shocks No exposure to direct sunlight, an ambient temperature of 0 to 50 (32 to 122 ) that does not change rapidly, and no icing An ambient non-condensing humidity of 35 to 85%RH No large capacity electromagnetic switches or cables through which large current flows No water, oil or chemicals or where the vapors of these substances can come into direct contact with the unit When this unit is installed inside a control panel, the ambient temperature of the unit - not the ambient temperature of the control panel - must be kept to under 50. Otherwise the life of electronic parts (especially electrolytic capacitors) of the unit will be shortened. Note: Avoid setting this unit directly on or near flammable material even though the case of this unit is made of flame-resistant resin. 2. Wiring Precautions Caution Do not leave wire remnants in the unit as they may cause a fire or a malfunction. Insert the connecting cable into the designated connector securely to prevent malfunction. Connect the wire for the AC power source to its designated terminals as described in this instruction manual. The IFP-100 will be damaged if the AC power source wire is connected to incorrect terminals. When wiring terminals of the IFP-100 at the terminal block, use correct ferrules with an insulation sleeve fitting for the terminal screw. Tighten the terminal screw using the specified torque. If excessive force is applied to the screw when tightening, the screw or case may be damaged. For a 24V AC/DC power source, do not confuse polarity when using direct current (DC). This unit does not have a built-in power switch, circuit breaker or fuse. Therefore, it is necessary to install them near the instrument. (Recommended fuse: Time-lag fuse, rated voltage 250V AC, rated current 2A) 3. Operation and Maintenance Precautions Warning Do not touch live terminals. This may cause an electric shock or problems in operation. Turn the power supply to the instrument OFF before retightening the terminal or cleaning. Working on or touching the terminal with the power switched ON may result in severe injury or death due to Electric Shock. Use a soft, dry cloth when cleaning the unit. (Alcohol based substances may tarnish or deface the unit.) As the display section is vulnerable, do not strike or scratch it with a hard object or put pressure on it. 2

1. Overview 1.1 Overview of the IFP-100 IFP-100 is a communication converter, which is connected to the PROFIBUS master unit (SIEMENS PLC, etc.) as a PROFIBUS-DP slave unit to exchange data. A maximum of 31 units of Shinko temperature controllers (for C series, 16 units of CPT-200) with SHINKO protocol can be connected to the IFP-100. 1.2 System Configuration IFP-100 PROFIBUS Master Unit PROFIBUS-DP RS-422A (RS-485) (SIEMENS PLC, etc.) Approved PROFIBUS cable (Fig. 1.2-1) SHINKO Temperature Controllers C series (CPT-200), FC series, GC series, PC-900, FCL-100, etc. (Products with SHINKO protocol) About GSD File When using the IFP-100 as a PROFIBUS-DP slave, register the parameters to the master unit by using the GSD file in which the functions, data format, etc. are defined. Please download the GSD file from the Shinko website. http://www.shinko-technos.co.jp/e/ Download To download Software 2. Model 2.1 Model IFP-100: Communication converter for PROFIBUS. 2.2 How to Read the Model Label Warning Turn the power supply to the instrument OFF before checking the model label. Working on or touching the terminal with the power switched on may result in severe injury or death due to Electric Shock. Model labels are attached to the case and inner assembly. [Example] IFP-100 Model: IFP-100 No. x x x x x x Serial number (indicated only on the inner assembly.) 3

3. Name and Functions of the Sections (1) (2) (3) (6) (4) (5) (Fig. 3-1) (1) POWER indicator While the power is turned on, the green indicator lights up. (2) TX/RX indicator During communication between the IFP-100 and controllers, the yellow indicator flashes. (3) BF indicator If PROFIBUS errors occur, the red indicator lights up. (4) Rotary switch for PROFIBUS address setting (x10) Sets IFP-100 s own address (the 2nd digit). (5) Rotary switch for PROFIBUS address setting (x1) Sets IFP-100 s own address (the 1st digit). (6) PROFIBUS-DP D-sub 9-pin connector Refer to (Fig. 3-2). 5 1: NC 9 2: NC 4 3: RxD/TxD-P 8 4: NC 3 5: DGND 7 6: VP 2 7: NC 6 8: RxD/TxD-N 1 9: NC (Fig. 3-2) 4

4. Mounting 4.1 Site Selection Caution Use within the following temperature and humidity ranges. Temperature: 0 to 50 (32 to 122 ) (No icing), Humidity: 35 to 85%RH (Non-condensing) If IFP-100 is mounted within a control panel, the ambient temperature of the unit - not the ambient temperature of the control panel - must be kept to under 50, otherwise the life of electronic parts (especially electrolytic capacitors) of the unit will be shortened. This instrument is intended to be used under the following environmental conditions (IEC61010-1): Overvoltage category, Pollution degree 2 Ensure the mounting location corresponds to the following conditions: A minimum of dust, and an absence of corrosive gases No flammable, explosive gases No mechanical vibrations or shocks No exposure to direct sunlight, an ambient temperature of 0 to 50 (32 to 122 ) that does not change rapidly An ambient non-condensing humidity of 35 to 85%RH No large capacity electromagnetic switches or cables through which large current is flowing No water, oil or chemicals or where the vapors of these substances can come into direct contact with the unit 4.2 External Dimensions (Scale: mm) DIN rail (EN50022) mounting 80 86 35.4 116 49 103 29 5 132 3.3 7.8 (Fig. 4.2-1) 2-4.5 hole 11-M3.5x7 screw with spring washer 4 80 40 Socket guide (indented) 50 (Fig. 4.2-2) 5

4.3 Mounting the Round Socket When shipped, the IFP-100 is attached to the Round socket. Remove the Round socket. (1) How to remove the Round socket from the IFP-100 Unlock Lock 1 at the top and bottom of the socket by moving them in the direction indicated by the arrow 1. If unlocked, pull out the IFP-100 in the direction indicated by the arrow 2. See (Fig. 4.3-1). 1 Lock 1 Lock 1 1 2 (Fig. 4.3-1) (2) How to mount the Round socket to the DIN rail Fit the socket upper side into the DIN rail first, then fit the lower side into the DIN rail. See (Fig. 4.3-2). The Round socket will be completely locked to the DIN rail with a clicking sound. Lock 2 (Fig. 4.3-2) How to remove the Round socket from the DIN rail: By using a flat bladed screwdriver, pull down Lock 2 at the bottom of the socket, and pull the socket up. When mounting the Round socket to the control panel, make sure the Socket guide (indented) aligned downward. Drill 2 holes of 4.5mm at 40mm pitch on the control panel, and mount the Round socket by tightening with screws and nuts (M4 x 20). 6

5. Wiring Warning Turn the power supply to the instrument OFF before wiring or checking. Working on or touching the terminal with the power switched on may result in severe injury or death due to Electric Shock. Caution Do not leave wire remnants in the unit as they may cause a fire or a malfunction. Insert the connecting cable into the designated connector securely to prevent malfunction. Connect the wire for the AC power source to its designated terminals as described in this instruction manual. The IFP-100 will be damaged if the AC power source wire is connected to incorrect terminals. When wiring terminals of the IFP-100 at the terminal block, use correct ferrules with an insulation sleeve fitting for the terminal screw. Tighten the terminal screw using the specified torque. If excessive force is applied to the screw when tightening, the screw or case may be damaged. For a 24V AC/DC power source, do not confuse polarity when using direct current (DC). This unit does not have a built-in power switch, circuit breaker or fuse. Therefore, it is necessary to install them near the instrument. (Recommended fuse: Time-lag fuse, rated voltage 250V AC, rated current 2A). 5.1 Terminal Arrangement 100 to 240 V AC 24V AC/DC + 8-7 6 5 4 SG 9 3 TXA 10 11 1 2 RXB RXA TXB RS- 422A (Fig. 5.1-1) 7

Solderless Terminal Use a solderless terminal with an insulation sleeve in which the M3.5 screw fits as shown below. The tightening torque is 0.7N m to 1.0N m. 3.7mm 3.7mm 6.6mm or less Solderless terminal Y type Ring type 5.2 Wiring Examples (Fig. 5.1-2) Manufacturer Model Tightening Torque Nichifu Terminal Industries CO., LTD. 1.25Y-3.5 Japan Solderless Terminal MFG CO., LTD. V1.25-YS3A Nichifu Terminal Industries CO., LTD. 1.25-3.5 Japan Solderless Terminal MFG CO., LTD. V1.25-M3 0.7N m Max. 1.0N m Notice Be sure to use a qualified PROFIBUS cable to connect PROFIBUS master unit and IFP-100. Use the communication cable CPM to connect IFP-100 and C series. Connect terminators to both ends of the unit. Use a thick wire (1.25 to 2.0mm 2 ) as a ground wire. [Connecting PROFIBUS master unit, IFP-100 and 1 block of C series] 6.6mm or less IFP-100 Communication cable, CPM C series Terminator (120 ) built-in RXA 1 RXB 11 4 3 RS-422A PROFIBUS Master unit (Siemens PLC) PROFIBUS cable TXA TXB SG 3 2 4 5 2 1 6 (Fig. 5.2-1) [Connecting PROFIBUS master unit, IFP-100 and multiple FC series] IFP-100 FC series Terminator (120 ) built-in RXA 1 RXB 11 11 12 YA YB PROFIBUS Master unit (Siemens PLC) PROFIBUS cable TXA 3 TXB 2 SG 4 16 COM (Fig. 5.2-2) 8 Terminator (120 ) 11 YA 12 YB 16 COM

[Connecting PROFIBUS master unit, IFP-100, 1 block of C series and multiple FC series] Terminator (120 ) built-in IFP-100 RXA 1 RXB 11 Communication cable, CPM 4 3 RS-422A C series PROFIBUS Master unit (Siemens PLC) PROFIBUS cable TXA TXB SG 3 2 4 5 2 1 6 Communication cable, CPM FC series 4 5 2 3 1 6 11 12 YA YB 16 COM (Fig 5.2-3) Terminator (120 ) 11 YA 12 YB 16 COM Use a qualified PROFIBUS cable to connect IFP-100 and PROFIBUS master unit. [Connecting Communication cable CPM and IFP-100] (Table 5.2-1) Communication cable CPM IFP-100 Terminal 4 Terminal 1 (RXA) Terminal 3 Terminal 11 (RXB) Terminal 5 Terminal 3 (TXA) Terminal 2 Terminal 2 (TXB) Terminals 1, 6 Terminal 4 (SG) [Connecting Communication cable CPM and SHINKO controller] (Table 5.2-2) Communication cable CPM SHINKO controller Terminals 4, 5 (YA) terminal Terminals 2, 3 (YB) terminal Terminals 1, 6 (COM) terminal Use Communication cable CPP to connect (multi-drop) multiple blocks of C series. 9

6. Setup Warning Turn the power supply to the instrument OFF before wiring or checking. Working on or touching the terminal with the power switched on may result in severe injury or death due to Electric Shock. Notice Be sure to set a PROFIBUS address of IFP-100 before the power supply to the unit is turned ON. Set up the Rotary switches. Using a small flat bladed screwdriver, set a PROFIBUS address of IFP-100. Setting range: 0 to 99 A maximum of 127 units are connectable for PROFIBUS, however, up to 99 can be set for the IFP-100 address. (Fig. 6-1) 7. Data Configuration When using the IFP-100 as a PROFIBUS-DP slave, register the parameters to the master unit by using the GSD file in which the functions, data format, etc. are defined. 7.1 Data Type Fixed length code: 1 or 20-item of data length can be set. For the FC series, etc., set 1-data length. For the C series, set 20-data length. When the FC series, etc. and C series are used together, set 20-data length. 7.2 Data Structure Data type: Fixed length code There are 2 buffers: Output buffer: Outputs the data from the PROFIBUS master unit to the IFP-100. Input buffer: Inputs the data from the IFP-100 to the PROFIBUS master unit. When configuring the output buffer and input buffer using the Hardware configuration, configure the output buffer first. If the input buffer is configured first, the PROFIBUS communication cannot be performed, and the BF indicator lights up. Data structure of Fixed length code (Output buffer, Input buffer) is shown on the next page. 10

[Output buffer] Data structure when the amount of data is 1. Information Address Sub address Command type Data item Data Data structure when the amount of data is 20. Information Address Sub address Command type Data item Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7 Data 8 Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 Data 16 Data 17 Data 18 Data 19 Data 20 Information: b7 b6 b5 b4 b3 b2 b1 b0 Command flag 0 Amount of data (01H to 32H) Address: Numbers by which the PROFIBUS master discerns each slave. Instrument number 0 to 94 and Global address 95. ASCII codes (20H to 7FH) are used by adding 20H to instrument numbers 0 to 95 (00H to 5FH). 95 (7FH) is called Global address, which is used when the same command is sent to all the slaves connected. However, the response is not returned. Sub address: 20H fixed Command type: Code to discern Reading command or Setting command. 22H/20H: Reading command 52H/50H: Setting command Data item: Data classification of the command object. (Refer to the Communication command of the controller connected to the IFP-100.) Data: Setting value, binary 11

[Input buffer] Data structure when the amount of data is 1. Information Address Sub address Command type Data item Data Data structure when the amount of data is 20. Information Address Sub address Command type Data item Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7 Data 8 Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 Data 16 Data 17 Data 18 Data 19 Data 20 b7 b6 b5 b4 b3 b2 b1 b0 Information: Response flag 0 0 0 Error code Address: The origin of the response. The same code as the received command is used for the response. Sub address: 20H fixed Command type: Code to discern Reading command or Setting command. 22H/20H: Reading command 52H/50H: Setting command Data item: Data classification of the command object. (Refer to the Communication command of the controller connected to the IFP-100.) Data: Reading value, binary Error code: Represents an error type. Error code Contents 0H No error (Acknowledgement) 1H Non-existent command 2H Incorrect designation of pattern, step 3H Setting value outside of the range 4H Status unable to be set (during AT) 5H During the setting mode by keypad operation 6H No response 7H Amount of data outside of the range 8H Any other error 12

7.3 Data Setting Procedures (1) Confirm that Command flag = 0 and Response flag = 0. (2) Set the address, sub address, command type and data item (Output buffer). (3) Set the setting value to the data section (Output buffer). (4) Set the amount of data (Output buffer). (5) Set the command flag to 1. (6) Wait until the Response flag becomes 1. (7) Confirm that the error code is 0, which means normal setting (Input buffer). (8) Set the command flag to 0. (9) The procedure is complete after response flag becomes 0. 7.4 Data Reading Procedures (1) Confirm that Command flag = 0 and Response flag = 0. (2) Set the address, sub address, command type and data item (Output buffer). (3) Set the amount of data (Output buffer). (4) Set the command flag to 1. (5) Wait until the Response flag becomes 1. (6) Confirm that the error code is 0, then read data from the data section (Input buffer). (7) Set the command flag to 0. (8) The procedure is complete after response flag becomes 0. 7.5 Data Flow Data flow of setting value and reading value is shown in (Fig. 7.5-1). PROFIBUS Master Unit PROFIBUS Communication IFP-100 Slave Data setting Writing via the program Data Buffer Buffer Data reading Reading via the program Data Buffer Buffer Shinko Controllers (with SHINKO protocol) (Fig. 7.5-1) 13

8. Specifications Model Communication converter for PROFIBUS Name IFP-100 Supply voltage 100 to 240V AC, 50/60Hz 24V AC/DC, 50/60Hz Allowable voltage fluctuation range 100 to 240V AC: 85 to 264V AC 24V AC/DC: 20 to 28V AC/DC External dimensions 49 x 80 x 132mm (W x H x D) (including Round socket) Mounting DIN rail mounting Case Flame-resistant resin, Black Indicators While the power is turned on, the green LED (POWER) lights up. During communication between IFP-100 and controllers, the yellow LED (TX/RX) flashes. When PROFIBUS is in error, the red LED (BF) lights up. Setting PROFIBUS address setting by the Rotary switch Setting range: 0 to 99 Communication functions Communication between the IFP-100 and PROFIBUS master unit Communication line: PROFIBUS-DP (RS-485) Communication speed: 9.6kbps, 19.2kbps, 93.75kbps, 187.5kbps, 500kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps (Automatically selected) The lowest communication speed of the instrument connected to the same PROFIBUS communication line is automatically selected as the default. Communication between the IFP-100 and Shinko controllers Communication line: RS-422A (RS-485) Communication speed: 19.2kbps fixed Data format: Stop bit: 1 Data length: 7 Parity: Even Stop bit: 1 Circuit insulation configuration RS-422A/RS-485 For controller communication Isolated Power Isolated CPU 5V DC power For PROFIBUS communication Isolated (Fig. 8.1-1) Insulation resistance 10M or more, at 500V DC Between power terminal and controller s communication terminal Between power terminal and PROFIBUS communication terminal 14

Dielectric strength Between power terminal and terminal No. 4 (SG) ----- 1.5kV AC for 1 minute Power consumption Approx. 5VA Ambient temperature 0 to 50 (32 to 122 ) Weight Approx. 200g Accessories Instruction manual: 1 copy 9. Troubleshooting If any malfunction occurs, refer to the following items after checking that power is being supplied to the PROFIBUS master unit, IFP-100 and Shinko controllers. Warning Turn the power supply to the instrument OFF before wiring or checking. Working on or touching the terminal with the power switched on may result in severe injury or death due to Electric Shock. Problem: Communication Failure Presumed Cause The communication cable is disconnected or imperfect contact between the cable and terminal. The PROFIBUS address of IFP-100 is not set. The wiring of communication cable is not correct. The terminators are not connected to both ends of unit. Solution Change the cables, or tighten the screw of the terminal securely. Set the address. (See Section 6. Setup.) Check that wiring is correct. (See Section 5. Wiring.) Connect terminators. (See Section 5. Wiring.) For all other malfunctions, please contact our main office or dealers. 15

******* Inquiry ******* For any inquiries about this unit, please contact our agency or the vendor where you purchased the unit after checking the following. [Example] Model --------------------------- IFP-100 Serial number ----------------- No. xxxxxx In addition to the above, please let us know the details of the malfunction, or discrepancy, and the operating conditions. Head Office : URL: E-mail: SHINKO TECHNOS CO.,LTD. OVERSEAS DIVISION 2-5-1, Senbahigashi, Minoo, Osaka, Japan http://www.shinko-technos.co.jp overseas@shinko-technos.co.jp Tel : Fax: 81-72-727-6100 81-72-727-7006 16