*** If you have a Quick Designer project skip this section ***

Similar documents
PROFIBUS DP Slave Driver

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE

TS8000. Profibus DP Slave Configuration Application Note TS8922U001

Profibus DP Driver for JMobile

General MODBUS TCP Master Driver

SIMATIC S7 MPI Direct Driver

Device/PLC Connection Manuals

MODBUS TCP Master Driver

TECHNICAL NOTE TNOI30

28 Simply Confirming On-site Status

11.1 Try to Write Recipe Data in Device/PLC

ROC Plus Ethernet Driver

DVPPF02-SL PROFIBUS DP Slave Communication Module

12 Writing CSV File Data in Device/PLC

Import SIMATIC variables

MODBUS PLUS Driver. Schneider Electric Industries

Modicon Quantum and Siemens S7-300 PLC as DP slave System User Guide [source code]

SIMATIC S5 CPU Direct Driver

16 Starting Optional Application

SIMIT 7. Gateways. User Manual

LEARNING ACTIVITY PACKET MECHATRONICS BASIC PLC PROGRAMMING (SIEMENS S7-300/STEP 7) B25014-AA02UEN

Mitsubishi FX Driver for JMobile

APNT#1208 GP-Pro EX to Allen Bradley RIO via Gateway. Explore Newer Solutions

Danfoss FCD 300 AS-i and Siemens DP/AS-i Link 20E

7 Device/PLC Communication

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

FAQ Communication over PROFIBUS

SANYO DENKI Servo Amplifier SANMOTION R and Pro-face AGP-3****-CA1M/LT Connection Procedure. Instruction Manual. Version1.0 (

5 Creating a Form Using Excel

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

7 Writing Device/PLC Data in CSV File

SIMATIC S5 CPU Direct Driver

Korea PROFIBUS/PROFINET Association 각사회사이름 각사 LOGO

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Device/PLC Connection Manuals

Connecting UniOP to Simatic S7 Profibus

SIMATIC. S7 and Profibus- DP Configuration Guide G1026

CONTROLLER INFORMATION SHEET

Connecting UniOP to Profibus DP TI

7 Writing Device/PLC Data in CSV File

C O N T R O L L E R I N F O R M A T I O N S H E E T. Siemens S7-300 Series (Ethernet)

Profibus Gateway 3E V Technical Bulletin

Modbus TCP Server Driver for JMobile

25 Saving Setting Guide Import/Export Nodes and Symbols

Software Release Note

8.1 Settings Menu. Settings Menu

8 Writing Device/PLC Data in Database

ProfinetCommander User Manual 3.1 March 2010

Technical Application Note

Software Release History. Version No. Build Date No./ Release Date. Bugs Fixed/Changes. Supported OS Apply to Models New Features/Enhancements

SAPHIR SIO Driver. Siemens Building Technologies

IE/PB LINK PN IO. PROFINET applications

TECHNICAL NOTE TNOI38

CS & IT Conversions. Magnitude 10,000 1,

Think & Do Profibus Network Setup with the H0 PSCM

30 Symbol Registration

32 Symbol Registration

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL ADDITIONAL MANUAL. Hioki E.E. Corporation Controller Smart Site

Profibus PLC Setup Hardware setup, jumper settings and SYCON configuration. Design Studio driver configuration and I/O sheet setup.

Replacement Guidebook

11 Importing GP Capture Data (JPEG)

New Features: 1. Support auto device routing for MGate MB3270, MB3280, and MB3480 series.

SIEMENS S7-200 PPI Direct

ABB Modbus RTU Driver for JMobile

DIASYS Netmation MODBUS TCP Driver

Cover. Configuration of an IM 308-C as DP Slave to a CP as DP Master PROFIBUS DP. FAQ July Service & Support. Answers for industry.

Replacement Guidebook

Series 90 Ethernet Driver

GW-7553 PROFIBUS/Modbus TCP Gateway

SIMATIC S7-PLCSIM V5.0. User Manual. Edition 06/

Name: Date: Review Packet: Unit 1 The Number System

Device/PLC Connection Manuals

Upgrading from the 1785-PFB/B to the SST-PFB-PLC5

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

Connecting UniOP to Beckhoff ADS Ethernet

RM30xx Profibus Brief instructions efector400

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

Unit 2: Accentuate the Negative Name:

Additel/LogII Wireless Data Logging Software. User Manual

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

Interfacing to J1939 with PROFIBUS DP

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Easy! Smooth! ST400 Series->GP4000M Series Replacement Guidebook

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

PROFI-5053 PROFIBUS Remote I/O Module Quick Start Guide

Drive System Application

This Datasheet is for the IC693PBM200. Profibus DP Master Module.

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL. Control Logix 5000 Series (Ethernet)

GP-2301S/L->GP4000M Series Replacement Guidebook

PROTOCOL COMMUNICATION pag. 1/22 NEMO 96 HD/HD+ Profibus DP Interface. Application manual

How to Use the TIA Portal to Set a Siemens PLC and the MGate 5103

Programmable Controllers

M-series Profibus DP Series 2 Plus Interface Card

Polling Data Registers from Siemens PLC Series S7-300, S7-400 & S7-1200

Hilscher Universal Driver Help Kepware Technologies

2.6 Configuring the Ethernet Communication Module as an EtherNet/IP Adapter

A complement number system is used to represent positive and negative integers. A complement number system is based on a fixed length representation

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE

Using PROFIsafe modules in combination with PROFIBUS-DP and PROFINET Application note

Transcription:

Application Note #1232: PROFIBUS Migration to GP-Pro EX Introduction GP-Pro PB3 and Quick Designer projects can be converted into GP-Pro EX projects using a project converter. However additional steps are required because each software package uses a different method of addressing PROFIBUS direct input and output I/O data. GP-Pro EX uses the more recent PROFIBUS standard peripheral address format. This is a guide to convert the original project direct I/O addressing to the PROFIBUS standard peripheral input (PI) and peripheral output (PQ) format. Both GP-Pro EX and the existing project configuration software will be required to complete the migration process. When a project is converted to GP-Pro EX the source project I/O addressing is retained in the result for programmer reference. All I/O these references must be manually converted in the GP-Pro EX project to peripheral I/O format. Requirements To replace an existing HMI the following items will be required: GP-Pro EX Pro-face configuration software Existing project file in editable form Configuration software for the existing project (GP-Pro PB3 or Quick Designer) CA5-PFSALL/EX-01 Pro-face PROFIBUS adapter GP3000 series Pro-face display compatible with the above adapter PROFIBUS master configuration software (from PROFIBUS master manufacturer) GSD electronic data sheet for CA5-PFSALL/EX-01 Pro-face available at: http://www.hmisource.com/otasuke/download/exdriver/plc/profibus_dp.htm GP-Pro PB3 to GP-Pro EX *** If you have a Quick Designer project skip this section *** GP-Pro EX includes a utility Project Converter to convert your GP-Pro PB3 project into a GP- Pro EX project. At the time of this writing only GP3000 series displays and a CA5-PFSALL/EX- 01 PROFIBUS DP slave communication module can connect to PROFIBUS. When configuring the Project Converter a dialog box Convert Destination will open with a request to Select a model. Page 1 of 9

The available choices may not include available GP3000 series models. In that case simply accept the default model. You can change it later in GP-Pro EX. Upon successfully converting a GP-Pro PB3 project to GP-Pro EX the following warning will appear: Actually the Direct Input/Output registers referred to are the LS addresses assigned to the PROFIBUS direct I/O in GP-Pro PB 3. The message is a notification that they were not modified during the conversion to GP-Pro EX. The Address Block Conversion feature in GP- Pro EX can be used to change these LS addresses to the PROFIBUS standard PI and PQ address format used in GP-Pro EX. Note: The term Input Area in GP-Pro refers to outputs from the perspective of the PROFIBUS PLC or master. GP-Pro EX uses the PLC or master perspective PROFIBUS standard addressing, so Input Area becomes PQ and PQW output addresses. Likewise Output Area in GP-Pro becomes PI and PIW input addresses in GP-Pro EX. To convert word references: 1. Open the original project in GP-Pro PB3 for reference. a. Click on GP Setup b. Click on the Communications Settings tab. 2. Open the converted project in GP Pro EX. a. Save a copy of the project under a different file name. b. At the top of the screen click on Project > Utility > Convert Addresses c. The Address Block Conversion window will open. Page 2 of 9

3. For Address Type select Word. 4. For Address to Convert Click on the button to the right of the entry field. a. For Device/PLC select #INTERNAL. Keep the default LS selection. b. In the numeric field enter the GP-Pro PB3 Direct I/O start Address value. c. To that value add Input Area Size minus 1 and enter the result in the field to the right. 5. For Addresses After Conversion click on the button and select PQW. The address should remain 0000. 6. Click [Convert] 7. Verify Address Type selection is Word. Page 3 of 9

8. For Address to Convert Click on the button to the right of the entry field. a. For Device/PLC select #INTERNAL. Keep the default LS selection b. In the numeric field enter the sum of GP-Pro PB3 Direct I/O start Address + Input Area Size. c. To that value add Output Area Size minus 1 and enter the result in the field to the right. 9. Addresses After Conversion should be [PLC1]PIW0000. If it is not click on the button and select PIW. 10. Click [Convert] 11. Save the project under another name to preserve these changes before proceeding. To convert bit references: PROFIBUS addressing is Byte oriented. GP-Pro PB 3 exchanges data between PROFIBUS direct I/O and arrays in LS memory. LS memory is word oriented so each word address consists of 2 byte addresses of PROFIBUS I/O. Also in the case of the GP-Pro EX PB3 Siemens PROFIBUS device driver, like Siemens S7 PLCs and some other Intel oriented devices, the bytes are swapped when combined into a word. Because the bytes are swapped when converting LS registers to PROFIBUS addressing LS word bits 15 8 become bit 7 0 in the first byte and LS bits 7 0 become bits 7 0 in the next byte. Note: LS bit registers are word address followed by the bit reference. Examples the bit reference LS4312 is LS word 43 bit 12. Bit reference LS12304 is LS word 123 bit 04. Assuming words are byte swapped and even numbered byte addressed in Siemens S7 format use this procedure. In each entry the appropriate bit value must be appended to the word address: 1. For Address Type select Bit. 2. For Address to Convert Click on the button to the right of the entry field. a. For Device/PLC select #INTERNAL. Keep the default LS selection b. In the numeric field enter the GP-Pro PB3 Direct I/O start Address. Append the digits 08. Click Enter. Example: If Direct I/O Start Address is 20 the entry is 2008. c. In the field to the right enter the result of the expression ( Direct I/O start Address + Input Area Size 1). Append the digits 07. Click enter. Example: Direct I/O Start Address is 20 and the Input area size is 16 the entry is 3507. 3. Addresses After Conversion should be [PLC1]PQ0000.0 If it is not click on the button and select PQ. Page 4 of 9

4. Click [Convert] 5. Verify Address Type selection is Bit. 6. For Address to Convert Click on the button to the right of the entry field. a. For Device/PLC select #INTERNAL. Keep the default LS selection b. In the numeric field enter the sum of GP-Pro PB3 Direct I/O start Address + Input Area Size. Append the digits 08. Click Enter. c. To the sum of Direct I/O start Address + Input Area Size + Output Area Size subtract 1 and enter the result in the field to the right. Append the digits 07. Press enter. 7. Addresses After Conversion should be [PLC1]PI0000.0 If it is not click on the button and select PI. 8. Click [Convert] Compare the Results Compare a range of addresses in the GP-Pro EX with the original GP-Pro project to confirm the results of the address conversion are correct. If Data Packet is Selected If Individual Device Settings in GP-Pro EX has Use Packet Transfer checked the System Area Start Address and Watchdog Write Address in GP-Pro EX must be defined. Please select valid Data Block integer (word) addresses from the PLC project. Warning: Be sure to carefully verify the final results for proper addressing and byte and bit orientation before operating machinery. Verify data exchanged between the PROFIBUS master device and GP-Pro EX is the correct value and in the expected location for each data type. Page 5 of 9

Quick Designer to GP-Pro EX *** If you have a GP-Pro project skip this section.*** A free Quick Designer to GP-Pro EX project migration tool, the Panel Station Import Utility, is available from Pro-face at: http://www.profaceamerica.com/cms/site/6d600be545e5a6af/index.html Review the Panel Station Import utility help manual carefully before beginning the conversion. You will also need the Quick Designer editor to make changes before the conversion and to compare the results after the conversion. At the time of this writing only GP3000 series displays and a PROFIBUS DP slave communication module p/n CA5-PFSALL/EX-01 are offered for hardware migration. Note: Quick Designer has various options for Word and bit Storage format and addressing. The following steps assume Siemens Step 7 bit and word orientation as well as byte addressing. If your Quick Designer project is configured differently following the steps below may not provide the correct results. The conversion: 1. Save a copy of the project so it can be opened later in Quick Designer for reference. 2. The Panel Station Import Tool does not support the PROFIBUS protocol. Open the Quick Designer project and change the protocol setting to <no protocol>. 3. Make any other changes to the project as suggested by the Panel Import Utility help manual and follow the steps to perform the migration to GP-Pro EX. 4. Open the converted project in GP-Pro EX. 5. Click on Project > System Settings> Device/PLC. Click Add Device/PLC. 6. Under Device Specific Settings click on the button to the right of PLC1. 7. Open the original Quick Designer project. Click on Setup > Protocol > Configure I/O 8. Copy these settings from the original Quick Designer project I/O Configuration dialog box to the new GP-Pro EX project Individual Device Settings dialog box. a. Copy Input # of Words to Direct I/O Input Size. b. Copy Output # of Words to Direct I/O Output Size. 9. Open Common Settings > Symbol Variables Quick Designer uses the actual PROFIBUS master I/O addresses. These addresses are retained in the converted project as Symbol Variables. The symbols have an underscore instead of a dot between the address and the bit. The next four steps describe how to replace the Memlink addresses with PROFIBUS Peripheral PI and PQ addresses. Note: If your project is large it may be easier to make a few sample address change of each data type and then export the Symbol Variable table to Excel to complete the addressing. Page 6 of 9

10. Input Words appear in the Name columns as IW** where ** is the PROFIBUS master address. The data type is Word Address. a. Click on the address field to the right of the Name. Click on the button that appears. Select PLC1. Select the default PIW. b. For the address subtract the original Quick Designer Project I/O configuration dialog box Inputs Start Address from the value in the GP-Pro EX Name column. Note: If the Quick Designer I/O Configuration is set to Word Boundaries multiply the Name column value x 2. c. Click on Enter. d. Repeat steps a. to d. for each input word. 11. Output Words appear in the Name columns as QW** where ** is the PROFIBUS master address. The data type is Word Address. a. Click on the address field to the right of the Name. Click on the button that appears. Select PLC1. Select the default PQW. b. For the address subtract the original Quick Designer Project I/O configuration dialog box Outputs Start Address from the value in the GP-Pro EX Name column. Note: If the Quick Designer I/O Configuration is set to Word Boundaries multiply the Name column value x 2. c. Click on Enter. d. Repeat steps a. to d. for each output word. Note: If the Quick Designer I/O Configuration is set to Word Boundaries or bytes are not swapped in the Quick Designer project the following steps for bit addressing are not expected to produce the correct results. Several scenarios are possible depending on the settings selected in Quick Designer and the PROFIBUS master configuration. Page 7 of 9

12. Input Bits appear in the Name column as I**_* where the decimal point is replaced by an underscore separating the master PRFIBUS address and bit designation. a. Click on the address field to the right of the Name. Click on the button that appears. Select PLC1. Select the default PI. b. For the address subtract the original Quick Designer Project I/O configuration dialog box Inputs Start Address from the value to the left of the underscore in the GP-Pro EX Name column. c. Enter a decimal point followed by the value to the right of the underscore in the Name column. d. Click on Enter. e. Repeat steps a. to e. for each input word. 13. Output Bits appear in the Name column as Q**_* with the decimal point separating the master byte address and bit designation replaced with an underscore. a. Click on the address field to the right of the Name. Click on the button that appears. Select PLC1. Select the default PI. b. For the address subtract the original Quick Designer Project I/O configuration dialog box Outputs Start Address from the value to the left of the underscore in the GP-Pro EX Name column. c. Enter a decimal point followed by the value to the right of the underscore in the Name column. d. Click on Enter. e. Repeat steps a. to e. for each input word. Compare the Results Compare a range of addresses in the GP-Pro EX with the original Quick Designer project to confirm the results of the address conversion are correct. Warning: Be sure to carefully verify the final results for proper addressing and byte and bit orientation before operating machinery. Verify data exchanged between the PROFIBUS master device and GP-Pro EX is the correct value and in the expected location for each data type. --------------------------------------------------------------------------------------- For more information on Pro-face and our full line of HMI, Operator Interface and Industrial PC products please visit our web site at www.profaceamerica.com. For technical support email: support@profaceamerica.com or call: 800.289.9266. --------------------------------------------------------------------------------------- 2015 Pro-face America. Specifications may change without notice. Pro-face is a registered trademark of Digital Corporation. Other brand or product names are the property of their respective owners. Page 8 of 9

Page 9 of 9