INSTRUCTION MANUAL High Resolution Indoor Dome Camera Model: DBD14 Please read this manual thoroughly before use and keep it handy for future reference.
-2-
INTRODUCTION Features Model Features: 1/3 Sony Super HAD II CCD 2.8-10.5mm Varifocal Day/Night Lens 540 TV lines of resolution VIDEO OUT(BNC) Operates in 12VDC Indoor Dome Model Camera Mounting: Surface Full 3Axis movement Easy installation. SPECIFICATIONS General DBD14 Image Sensor 1/3 Sony Super HAD(tm) II CCD Effective Pixel H: 768 V: 494 Effective Pixel Area H: 5.59mm V: 4.68mm Scan System 2:1 Interlace NTSC Scan Frequency H: 15.734KHz, V: 59.94Hz Synchronization Internal Minimum Illumination 0.1 Lux F 1.2 S/N Ratio 50dB @ AGC Off Resolution 540 TV Line White Balance Auto 1800 K ~ 10500 K AES Speed 1/60~1/100000 Sec Gain Control Auto BLC Manual Video Output 1.0Vpp @ 75 ohm Termination BNC Female Lens/ Lens Mount Manual 2.8 10.5mm F1.4 Viewing Angle H: 96.7 24.1, V: 71.2 18.2, D: 124.3 30.2 Power Source 12Vdc Power Consumption Max 3.5W Operating Tem Range -10 C ~ 50 C Operating Range Within 90% RH Dimension 150x109mm Gamma 0.45 Housing Material ABS Dome Bubble Material Polycarbonate -3-
MEASUREMENTS 95.0 mm 3.74 in 140.0 mm 5.51 in 56.0 mm 2.20 in 109 mm 4.29 in 140.0 mm 5.51 in 150 mm 5.91 in PACKING CONTENTS Indoor Dome package contains the following: Camera in housing----------------------------------1 Instruction guide (This Document)--------------1 Drill Template-----------------------------------------1 Mounting screw pack-------------------------------1 PARTS DESCRIPTION Dome cover (transparent) Mounting Holes Camera body Body cover Wire hole Front View Dome base Bottom View -4-
INSTALLATION. INDOOR DOME 1 1) Remove camera base by twisting it clockwise to lign up the arrows on the side of the camera housing (see FIG 1). Remove the camera base by pulling it away from the camera. FIG 1 Note: Dome cover is attached to a cord to stop falling off. 2 Open 2) Remove the dome cover by inserting a flat screw driver into the slot next to the dome cover release clip (See FIG 2) and pressing down on the screwdriver FIG 2 3 Ceiling Dome base Cut Away for Cable side exit Note: If your installation requires cable to be from side of dome, remove the cut away portion of the base. 3) Attach base to surface using drill template as a guide. With base attached, re-fit the body of the camera onto the base using the arrows as a guide (see FIG 1) and turning the camera clockwise. 4 Camera Body Open Close -5-4) Adjust camera viewing angle and secure into place by tightening thumb screws. Re-attach the camera cover, using the dome cover release clip as a guide, until it snaps into place. Note: Lens adjustment levers are by default in the locked position. Turn counter clockwise to unlock. Tighten levers to secure lens setting.
TROUBLE SHOOTING Refer to the following table if you are experiencing trouble with your camera. Contact an authorized technician if the table does not provide you with a solution to the trouble. Nothing appears on the screen. Check that the power cord and line connection between the camera and monitor are connected properly. Check that you have properly connected VIDEO cable to the camera VIDEO output jack. The image on the screen is dim. Is lens stained with dirt? Clean lens with soft, clean cloth. Adjust the monitor contrast & brightness controls Re-position the camera if necessary. The image on the screen is dark. Adjust the contrast feature of the monitor. If you have an intermediate device, set the 75Ω / Hi-z properly. The camera is not working properly, and the surface of the camera is hot. Color is not correct. Under certain incandescent lighting,some color shifting may take place. This is normal due to sensitivity to IR light. When the resistance value of copper wire is at [20 C(68 F)] Copper wire size (AWG) #24(0.22mm2) #22(0.33mm2) #20(0.52mm2) #18(0.83mm2) Resistance (Ω/m) 0.078 0.050 0.030 0.018 Voltage Drop (V/m) 0.028 0.018 0.011 0.006 As shown in the table above, voltage decreases as the wire gets longer. Therefore use of an excessively long adaptor output line for connection to the camera may affect the performance of the camera. *Standard voltage for camera operation : DC 12V ±10% *There may be some deviation in voltage drop depending on the type of wire and the manufacturer. Notes Be sure to connect power only after all the installation is complete. Use the UL listed, CLASS 2 power transformer for 12v adaptor. -6-