DICOM Conformance Statement for PenFetch

Similar documents
Hologic Physician s Viewer 5.0 DICOM Conformance Statement

XPLORE GESTION SCP WORKLIST CONFORMANCE STATEMENT

DICOM Conformance Statement

DICOM 3.0 Conformance Statement DXIMAGE RIS

Philips Medical Systems DICOM Conformance Statement USIT 1.5

Philips Medical Systems DICOM Conformance Statement USIT 1.5 L3

Kodak Point of Care CR systems. DICOM Conformance Statement

DICOM Conformance Statement

DxServer for Windows NT DICOM 3.0 Conformance Statement. Document Reference (Référence du document): 00/ Dec28/ABA/MM100/410A

Matrix Server and Client DICOM Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

Surgimap. DICOM Conformance Statement. Revision 2.0

DICOM Conformance Statement

DICOM Conformance Statement. EasyWeb 3.0. Document Number XZR January Copyright Philips Medical Systems Nederland B.V.

OASIS V4.0 DICOM Conformance Statement Rev. 3

DICOM Conformance Statement Product Name HCP DICOM Net Version

DICOM CONFORMANCE STATEMENT. BrainLAB PatXfer 5

DICOM Conformance Statement

PRO DATA Srl. DICOM MODALITY WORKLIST SCU Conformance Statement (MicroPrint-modality-worklist-scu.sxw)

HCP DICOM Net DICOM Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement

DICOM Conformance Statement

Medical Imaging Consultants, Inc.

NumaStore 1.0 DICOM 3.0 Conformance Statement

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

Philips Medical Systems DICOM Conformance Statement. Inturis Suite R2.2

SIEMENS. DICOM Conformance Statement

DICOM Conformance Statement, Biim Ultrasound App Version 1

SonoWin Picture Archiving System

JiveX Enterprise PACS Solutions. JiveX DICOM Worklist Broker Conformance Statement - DICOM. Version: As of

DCMburner version 3.3.0

Abstract. XrayVision DICOM Conformance Statement. Abstract Abstract

Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

Topcon Medical Systems

DICOM Conformance Statement (DCS) Rev 1.1. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

DICOM Conformance Statement for IMAGEnet 5

DICOM 3.0. ENsphere CONFORMANCE STATEMENT. Physician s Workstation

DAR Revision Date: July,

DICOM 3.0 Conformance Statement DICOMlink for DELTAmanager Send

Philips Medical Systems. Intera Document Number April 2003

Artwork consists of sixty-five (65) 8 ½ inch x 11 inch pages.

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

nstream Version 3.1 DICOM Conformance Statement

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

Philips Medical Systems. Xcelera R1.1L1. Document Number XPR July 2003

DICOM Conformance Statement (DCS) Rev 1.2. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0

Infinity Medical Soft, Inc ,Higashinaganuma,Inagishi, Tokyo JAPAN

DICOM Conformance Statement FORUM

Aloka ProSound DICOM

SonoWin Picture Archiving System

Application Launcher 2.2 DICOM Conformance Statement

DICOM Conformance Statement. CharruaPACS

DE32-DCM DentalEye 3.2. DICOM conformance statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)

X-Porte DICOM Conformance Statement

DICOM Conformance Statement. Forum

CHILI CHILI PACS. Digital Radiology. DICOM Conformance Statement CHILI GmbH, Heidelberg

WINRAD-32 Teleradiology System Conformance Claim

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

QCT PRO DICOM Conformance Statement

Sonovision DICOM Conformance Statement

Media Writer DICOM Conformance Statement

DICOM 3.0 Conformance Statement

DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:

ETIAM Nexus. DICOM Conformance Statement.

HEALTHCARE DICOM Conformance Statement

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

Beschreibung Gesamt / Total Description

Philips Medical Systems DICOM Conformance Statement

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

DICOM CONFORMANCE STATEMENT STORAGE SCU FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-053A or XIDF-056A (MIIXR0001EAB)

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

CONFORMANCE STATEMENT

DICOM Conformance Statement FORUM

dicom PACS DX-R Version 3.0

NumaLink-3.0 DICOM 3.0 Conformance Statement

DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement. for ES9410 DICOM

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

DAR-9400f / DAR-9500f DICOM Conformance Statement Revision J

REVISION HISTORY... 4 NOTE... 5 INTRODUCTION... 5 DICOM CONFORMANCE STATEMENT...

DICOM Conformance Statement Merge Eye Care PACS v. 4.0

Digital Imaging COmmunications in Medicine. DICOM in a Nutshell

NMKOMMT. pfaf`lj =tip. af`lj=`çåñçêã~ååé=pí~íéãéåí= båöäáëü. spkm. oéäé~ëéç=oqlmtlommt. Ñçê=éêçÇìÅí=îÉêëáçå=Ñêçã=PKM=çåï~êÇë

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

DICOM V3.0 Conformance Statement. SenoIris 1SP2

DAR-9400f/DAR-9500f with Gateway Option DICOM Conformance Statement. Revision D

DICOM Conformance Statement

ASTERIS MDS. DICOM Conformance Statement. for. Asteris Modality Distribution System (MDS) Software. Last Document Update: July 22, 2008.

Merge PACS TM v. 7.0 DICOM CONFORMANCE STATEMENT MODALITY WORKLIST. Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029

TITAN DICOM Conformance Statement

Transcription:

Penrad Technologies, Inc. DICOM Conformance Statement for PenFetch 10580 Wayzata Blvd. Suite 200 Minnetonka, MN 55305 www.penrad.com Copyright PenRad Technologies, Inc. May 2007 Page 1 of 9

1 Introduction...3 1.1 Scope and Field of Application...3 1.2 Acronyms...3 2 Implementation Model...4 2.1 Application Data Flow Diagram...4 2.2 Functional Definitions of Application Entities...5 2.3 Sequencing of Real-World Activities...5 3 AE Specifications...5 3.1 AE Specifications for PenFetch...5 3.1.1 Association Establishment Policies...6 3.1.1.1 General...6 3.1.1.2 Number of Associations...6 3.1.1.3 Implementation Identifying Information...6 3.1.2 Association Initiation Policy...6 3.1.2.1 Move Studies to a Remote System...6 3.1.2.1.1 Associated Real World Activity...6 3.1.2.1.2 Accepted Presentation Contexts...6 3.1.2.2 Retrieve a Modality Worklist from a Remote System...7 3.1.2.2.1 Associated Real World Activity...7 3.1.2.2.2 Accepted Presentation Contexts...7 3.1.2.2.3 SOP Specific Conformance for SOP Class Storage...7 3.1.2.3 Query Study/Series from a Remote System...7 3.1.2.3.1 Associated Real World Activity...7 3.1.2.3.2 Accepted Presentation Contexts...8 3.1.2.3.3 SOP Specific Conformance for Query SOP Classes...8 4 Communication Profiles...8 4.1 Supported Communication Stacks...8 4.2 TCP/IP Stack...8 4.2.1 Physical Media Supported...9 5 Extensions/Specialization/Privatizations...9 6 Configuration...9 Copyright PenRad Technologies, Inc. May 2007 Page 2 of 9

1 Introduction 1.1 Scope and Field of Application To provide Dicom pre-fetch capabilities for view stations. 1.2 Acronyms The following acronyms and abbreviations are used in this document. AE ACR ANSI DICOM GUI HIS IOD NEMA PACS PDU RIS SCP SCU SOP TCP/IP UID VR Application Entity American College of Radiology American National Standards Institute Digital Imaging and Communications in Medicine Graphical User Interface Hospital Information System Information Object Definition National Electrical Manufacturers Association Picture Archiving and Communications System Protocol Data Unit Radiological Information System Service Class Provider Service Class User Service Object Pair Transmission Control Protocol/Internet Protocol Unique Identifier Value Representation Furthermore, all symbols, abbreviations, and definitions used herein are described in the Digital Imaging and Communications in Medicine (DICOM) standard, parts 1 through 13 (NEMA PS3.1-13). Copyright PenRad Technologies, Inc. May 2007 Page 3 of 9

2 Implementation Model 2.1 Application Data Flow Diagram DICOM STANDARD INTERFACE Verification SCU/SCP PenFetch DICOM Service Move SCU Modality Worklist SCU Query/ Retrieve SCU DICOM STANDARD INTERFACE Copyright PenRad Technologies, Inc. May 2007 Page 4 of 9

2.2 Functional Definitions of Application Entities The PenFetch system supports Verification Services as a SCP. The DICOM Service Class User may request a C-ECHO operation to verify communications with the SCP. The PenFetch system acts as a SCU for Verification, Move, Modality Worklist, and Query/Retrieve SOP classes. 2.3 Sequencing of Real-World Activities No sequencing of Real World activities is required. An association is opened at the beginning of each activity and the association is ended when the activity is completed. 3 AE Specifications 3.1 AE Specifications for PenFetch The PenFetch system Application Entity provides Standard Conformance to the following DICOM v3.0 SOP Class as a SCP: SOP Classes as SCP SOP Class UID SOP Class Name Verification 1.2.840.10008.1.1 Verification The PenFetch system Application Entity provides Standard Conformance to the following DICOM v3.0 SOP Class as a SCU: SOP Classes as SCU SOP Class UID SOP Class Name Verification 1.2.840.10008.1.1 Verification Move 1.2.840.10008.5.1.4.1.2.2.2 Study Root Move Modality Worklist Management 1.2.840.10008.5.1.4.31 Modality Worklist Information Model Query 1.2.840.10008.5.1.4.1.2.1.1 Patient Root Query Copyright PenRad Technologies, Inc. May 2007 Page 5 of 9

3.1.1 Association Establishment Policies 3.1.1.1 General Application Context Name 1.2.840.10008.3.1.1.1 Maximum PDU size offered Maximum PDU size accepted Unlimited Unlimited 3.1.1.2 Number of Associations Not configurable 3.1.1.3 Implementation Identifying Information Implementation UID Implementation Version Name TBD PenFetch 3.1.2 Association Initiation Policy 3.1.2.1 Move Studies to a Remote System 3.1.2.1.1 Associated Real World Activity The PenFetch system can be configured to move studies to any number of remote systems. PenFetch will search for studies a view station will need for display. PenFetch will issue a C-Move to a PACS on selected studies for each remote system(s) configured. 3.1.2.1.2 Accepted Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Name UID Name UID Study Root Move 1.2.840.10008.5.1.4.1.2.2.2 Implicit VR Little Endian Extended Negotiation 1.2.840.10008.1.2 SCU None Copyright PenRad Technologies, Inc. May 2007 Page 6 of 9

3.1.2.2 Retrieve a Modality Worklist from a Remote System 3.1.2.2.1 Associated Real World Activity The PenFetch system will query a remote device(s) for a Modality Worklist to determine which patients need prior studies moved to the view station(s). The PenFetch system has two uses for the worklist. First, will populate the view stations with x number of prior studies. The other is looking for current studies added during the day. 3.1.2.2.2 Accepted Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Name UID Name UID Modality Worklist Query 1.2.840.10008.5.1.4.31 Implicit VR Little Endian Extended Negotiation 1.2.840.10008.1.2 SCU None 3.1.2.2.3 SOP Specific Conformance for SOP Class Storage The fields below are always included in the query request to ask the SCP to return them for each response. Modality Worklist Query Module Description Tag Scheduled Procedure Step Patient Identification Schedule Procedure Step Sequence (0040,0100) > Schedule Procedure Step Start Time (0040,0002) > Schedule Procedure Step Stop Time (0040,0003) > Modality (0008,0060) Patient s Name (0010,0010) Patient ID (0010,0020) Other Patient ID s (0010,1040) Patient Demographics Patient Birth Date (0010,0030) Patient Sex (0010,0040) Imaging Service Referring Physicians Name Request (0008,0090) Requested Procedure Requesting Physician (0032,1032) 3.1.2.3 Query Study/Series from a Remote System 3.1.2.3.1 Associated Real World Activity The PenFetch system will query a remote device(s) for Study and/or Series information. After querying a Modality Worklist, PenFetch determines which studies to Move to remote destinations. It will query the Study level using Patient ID and a Date range for Study Date. PenFetch may query the Series Level using Patient ID and Study Instance UID. Copyright PenRad Technologies, Inc. May 2007 Page 7 of 9

3.1.2.3.2 Accepted Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Name UID Name UID Patient Root Query 1.2.840.10008.5.1.4.1.2.1.1 Implicit VR Little Endian Extended Negotiation 1.2.840.10008.1.2 SCU None 3.1.2.3.3 SOP Specific Conformance for Query SOP Classes Fields retrieved are listed in the tables below. Patient Root Query Study Level Module Description Tag Patient Identification Patient ID (0010,0020) General Study Study Date (0008,0020) Study Time (0008,0030) Accession Number (0008,0050) Modalities In Study (0008,0061) Study Description (0008,1030) Study Instance UID (0020,000D) Patient Root Query Series Level Module Description Tag Patient Identification Patient ID (0010,0020) General Study Study Instance UID (0020,000D) General Series Modality (0008,0060) Body Part Examined (0018,0015) Series Instance UID (0020,000E) 4 Communication Profiles 4.1 Supported Communication Stacks The PenFetch system provides DICOM v3.0 TCP/IP Network Communication Support as defined in Part 8 of the DICOM Standard 4.2 TCP/IP Stack The PenFetch system utilizes the TCP/IP stack from the Microsoft Windows platform. Copyright PenRad Technologies, Inc. May 2007 Page 8 of 9

4.2.1 Physical Media Supported The PenFetch system is independent of the physical medium over which TCP/IP executes. Any device listed in the Microsoft Windows Hardware compatibility list may be used 5 Extensions/Specialization/Privatizations Not applicable. 6 Configuration The PenFetch system utilizes XML configuration files for the setting of all configurable settings. Copyright PenRad Technologies, Inc. May 2007 Page 9 of 9