DICOM Conformance Statement

Similar documents
JiveX Enterprise PACS Solutions. JiveX DICOM Worklist Broker Conformance Statement - DICOM. Version: As of

DIMEX REMOTE SETUP GUIDE

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

PRO DATA Srl. DICOM MODALITY WORKLIST SCU Conformance Statement (MicroPrint-modality-worklist-scu.sxw)

DICOM Conformance Statement for PenFetch

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

Sep, th Edition 897N101668H

DICOM CONFORMANCE STATEMENT

Kodak Point of Care CR systems. DICOM Conformance Statement

JiveX Web-enabled solutions for medical imagecommunication

Digital Lightbox 1.0

DICOM Conformance Statement

DICOM Conformance Statement. Forum

SonoWin Picture Archiving System

DICOM Conformance Statement FORUM

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

Surgimap. DICOM Conformance Statement. Revision 2.0

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

XPLORE GESTION SCP WORKLIST CONFORMANCE STATEMENT

Philips Medical Systems DICOM Conformance Statement USIT 1.5

PRO DATA Srl. MicroPrint. DICOM STORE SCU Conformance Statement (MicroPrint-prnsrv-store-scu.sxw)

1 CONFORMANCE STATEMENT OVERVIEW

DICOM Conformance Statement

DxServer for Windows NT DICOM 3.0 Conformance Statement. Document Reference (Référence du document): 00/ Dec28/ABA/MM100/410A

Topcon Medical Systems

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

DICOM Conformance Statement FORUM

MediPlus TM PACS&RIS Version 2.6

DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:

Philips Medical Systems DICOM Conformance Statement USIT 1.5 L3

Uscan. DICOM Conformance Statement

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

DICOM Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement

DICOM Conformance Statement Product Name HCP DICOM Net Version

Punctual Dicom Workstation

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DICOM Conformance Statement (DCS) Rev 1.1. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

AG Mednet Agent DICOM Conformance Statement Version 1.3

DICOM Conformance Statement. Fusion RIS Version 3.1

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

DICOM CONFORMANCE STATEMENT. BrainLAB PatXfer 5

SonoWin Picture Archiving System

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

Patterson DICOM Imaging. DICOM Conformance Statement

NumaStore 1.0 DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM. Infinix Celeve-i series / Infinix-i series Model XIDF-3DP801 AND ANGIO WORKSTATION

NumaLink-3.0 DICOM 3.0 Conformance Statement

HCP DICOM Net DICOM Conformance Statement

DICOM Conformance Statement (DCS) Rev 1.2. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number:

Parascript AccuDetect CAD Software System

OASIS V4.0 DICOM Conformance Statement Rev. 3

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

DICOM Conformance Statement

Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

efx Software DICONDE Conformance Statement

FUSION RIS 3.30 DICOM Conformance Statement

QCT PRO DICOM Conformance Statement

DICOM 3.0 Conformance Statement DXIMAGE RIS

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)

CHILI CHILI PACS. Digital Radiology. DICOM Conformance Statement CHILI GmbH, Heidelberg

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM. Infinix Celeve-i series / Infinix-i series Model DFP-8000 series V4.

DICOM 3.0 Conformance Statement for PlatinumOne Systems

DICOM Conformance Statement

DICOM Conformance Statement for Selenia Dimensions Acquisition Workstation Software Version 1.8 Part Number MAN Revision 002

DICOM Conformance Statement. EasyWeb 3.0. Document Number XZR January Copyright Philips Medical Systems Nederland B.V.

Image Display DICOM Conformance Statement EasyViz 7.2

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English

Matrix Server and Client DICOM Conformance Statement

DICOM Conformance Statement for IMAGEnet 5

DCMburner version 3.3.0

Infinity Medical Soft, Inc ,Higashinaganuma,Inagishi, Tokyo JAPAN

Abstract. XrayVision DICOM Conformance Statement. Abstract Abstract

DICOM Conformance Statement

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

Technical Publications

DICOM V3.0 Conformance Statement. SenoIris 1SP2

dicom PACS DX-R Version 3.0

DICOM CONFORMANCE STATEMENT FOR VANTAGE-GALAN TM VERSION V5.0

Lumify 1.8.x DICOM Conformance Statement

Echology Server. DICOM Conformance Statement Volume 1. <Storage and Query/Retrieve Server> Revision 1.0 Software Version 5.

Application Launcher 2.2 DICOM Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Image Display DICOM Conformance Statement

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

Technical Publications

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL DRAD-3000A, DRAD-3000E

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0

DICOM Conformance Statement

Technical Publications

Transcription:

DIMEX.HYBRID Schäf Systemtechnik GmbH Falkenstrasse 22 D-91580 Petersaurach Germany Phone: +49 (0) 9872 2002 Fax: +49 (0) 9872 2823 E-Mail: support@sstmed.com WWW: http://www.sstmed.com Page 1

TABLE OF CONTENTS Conformance Statement Overview... 4 Introduction... 4 Revision History... 4 Audience... 4 Remarks... 5 Definitions, Terms and Abbreviations... 5 Networking... 6 Application Data Flow... 6 Functional Definition of DICOM Storage SCP Service... 7 Functional Definition of DICOM Storage SCU Service... 7 Application Entity Specifications... 7 Dimex.Hybrid DICOM Storage SCP Service... 7 SOP Classes... 7 Association Acceptance Policy... 8 Description and Sequencing of Activities... 8 Accepted Presentation Contexts... 8 SOP Specific Conformance For Storage SOP Classes... 9 SOP Specific Conformance for Worklist SOP Class... 9 Network Interfaces... 10 Physical Network Interface... 10 Additional Protocols... 10 Configuration... 11 Local AE Titles... 11 Remote AE Title/Presentation Address Mapping... 11 Security... 11 Security Profiles... 11 Association Level Security... 12 Application Level Security... 12 Page 2

Annexes... 12 Private Transfer Syntaxes... 12 Page 3

CONFORMANCE STATEMENT OVERVIEW is applications that implement a DICOM Communication and allows to store and send images. SOP Classes User of Service (SCU) Provider of Service (SCP) Transfer Computed Radiography Image Storage Yes Yes Digital Mammography Image Storage For Presentation Digital Mammography Image Storage For Processing Yes Yes Yes Yes Digital X-Ray Image Storage For Presentation Yes Yes Digital X-Ray Image Storage For Processing Yes Yes INTRODUCTION This documents the conformance of the software with the Digital Imaging and Communications in Medicine (DICOM) standard. This document is essential in order to evaluate whether or not another DICOM compliant device can communicate with this software product. This statement is conforming to the recommended format as described in PS 3.2 of the DICOM standard. REVISION HISTORY Revision 1.0 Rossel 2010-06-09 Draft for official review Revision 1.0 Rossel 2010-06-10 Final draft AUDIENCE This document is intended for hospital staff, health system integrators, software designers or Implementers. It is assumed that the reader has understood the DICOM specifications. Page 4

REMARKS If another device matches this Conformance Statement when compared with its own Conformance Statement, there is a chance but no guarantee that they might interoperate. DICOM only deals with communication, it is not a standard with specifies what is needed for Certain applications to run on a device. DEFINITIONS, TERMS AND ABBREVIATIONS ASCII AE ANSI CR DICOM IOD MG NEMA SCP SCU SR TCP/IP UID American Standard Code for Information Interchange Application Entity American National Standards Institute Computed Radiography Digital Imaging and Communications in Medicine Information Object Definition Mammography National Electrical Manufactures Association Service Class Provider Service Class User Structured Report Transmission Control Protocol Unique Identifier Page 5

NETWORKING APPLICATION DATA FLOW The Modality Worklist query can be done at any time when running. The user can select modality form a list, and queries the specified Modality Worklist SCP to retrieves data for patient s scheduled to come in. Once the list is received from the SCP it is displayed, and will be automatically exported. Page 6

FUNCTIONAL DEFINITION OF DIMEX.HYBRID DICOM STORAGE SCP SERVICE Within the there is on DICOM Storage SCP Service that takes care of receiving the images and storing them to a temporary directory. FUNCTIONAL DEFINITION OF DIMEX.HYBRID DICOM STORAGE SCU SERVICE Within the there is on DICOM Storage SCU Service that are able to send the images. This application acts as a SCU for the Storage SOP classes. APPLICATION ENTITY SPECIFICATIONS DIMEX.HYBRID DICOM STORAGE SCP SERVICE The DICOM Storage SCP Service is an application entity that automatically starts together with the application. When the is terminated, the DICOM Storage SCP Service stops accepting any further associations and aborts all currently active associations. SOP CLASSES This application entity provides Standard Conformance to the following DICOM SOP Classes: SOP Class Name SOP Class UID SCU SCP Computed Radiography Image Storage Digital Mammography Image Storage For Presentation Digital Mammography Image Storage For Processing Digital X-Ray Image Storage For Presentation Digital X-Ray Image Storage For Processing Modality Worklist Information Model - FIND 1.2.840.10008.5.1.4.1.1.1 No Yes 1.2.840.10008.5.1.4.1.1.1.2 No Yes 1.2.840.10008.5.1.4.1.1.1.2.1 No Yes 1.2.840.10008.5.1.4.1.1.1.1 No Yes 1.2.840.10008.5.1.4.1.1.1.1.1 No Yes 1.2.840.10008.5.1.4.3.1 Yes No Page 7

ASSOCIATION ACCEPTANCE POLICY The DICOM Storage SCP Service application entity accepts an association after receiving an association request from a valid SCU. The application entity accepts incoming association requests on a single IP-address and a single port number as defined in the configuration. It accepts any association for which at least one presentation context is accepted. It creates a new thread for each incoming DICOM association request. The association remains open until one of the following events take place: The remote application entity closes the application An error condition leading to an association abort occurs A timeout occurs DESCRIPTION AND SEQUENCING OF ACTIVITIES This activity is initiated by a remote Storage SCU opening an association in order to transmit images to the Storage SCP Service. Diagram 1 shows a possible sequence of events for this activity. The remote Storage SCU opens an association and sends one or more DICOM images using C-STORE request messages. Finally, the remote Storage SCU closes the association. Diagram 1: Sequencing Diagram for Activity Receive Objects. ACCEPTED PRESENTATION CONTEXTS SOP Class Name SOP Class UID Transfer Syntax Role Extended Negotiation Computed Radiography Image Storage 1.2.840.10008.5.1.4.1.1.1 See below SCP None Page 8

Digital Mammography Image Storage For Presentation Digital Mammography Image Storage For Processing Digital X-Ray Image Storage For Presentation Digital X-Ray Image Storage For Processing 1.2.840.10008.5.1.4.1.1.1.2 See below SCP None 1.2.840.10008.5.1.4.1.1.1.2.1 See below SCP None 1.2.840.10008.5.1.4.1.1.1.1 See below SCP None 1.2.840.10008.5.1.4.1.1.1.1.1 See below SCP None Transfer Syntax Name Transfer Syntax UID Implicit VR Little Endian 1.2.840.10008.1.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 Explicit VR Big Endian 1.2.840.10008.1.2.2 JPEG Lossless 1.2.840.10008.1.2.4.70 JPEG2000 1.2.840.10008.1.2.4.90 The default behavior of the DICOM Storage SCP Service is to accept as SCP for each of the supported SOP Classes all presentation context containing one or more of the following transfer syntaxes. It is possible to configure the transfer syntaxes accepted by this application. The application entity will accept all presentation contexts that contain one of the supported SOP classes and one of the supported transfer syntaxes. The default behavior for the selection of the transfer syntax is to choose the first supported transfer syntax for each presentation context. SOP SPECIFIC CONFORMANCE FOR STORAGE SOP CLASSES The DICOM Storage SCP Service will receive any DICOM objects of a supported SOP Class type transmitted through an open association provided if the correct presentation context is used. If the objects have been successfully received, they are stored and ready to export. If the Storage SCP Service receives objects that are already present in the temporary directory (the SOP Instance UID already exists), the existing object will be kept and the transmission itself will be complete successfully. It is also possible to change the configuration to overwrite the existing object. SOP SPECIFIC CONFORMANCE FOR WORKLIST SOP CLASS provides standard conformance, a list of support keys are listed below: Page 9

Presentation Context Table For Modality Worklist Management Scheduled Procedure Step Modality (0008,0060) Scheduled Procedure Step Start Date (0040,0002) Scheduled Procedure Step Start Time (0040,0003) Scheduled Procedure Step Location (0040,0011) Performing Physician Name (0040,0006) Imaging Service Request Accession Number (0008,0050) Referring Physician Name (0008,0090) Body Part Examined (0018,0015) Patient Demographics Patient ID (0010,0020) Patient Name (0010,0010) Patient Sex (0010,0040) Date of Birth (0010,0030) Requested Procedure Study Instance UID (0020,000D) Requested Procedure ID (0040,1001) Requested Procedure Description (0032,1060) NETWORK INTERFACES PHYSICAL NETWORK INTERFACE The application is indifferent to the physical medium over which TCP/IP executes. ADDITIONAL PROTOCOLS When host names rather than IP addresses are used in the configuration to specify presentation addresses for remote AEs, the application is dependent on the name resolution mechanism of the underlying operation system. Page 10

CONFIGURATION LOCAL AE TITLES The local application entity names can be configured in the configuration. Application Entity Default AE Title Default TCP/IP Port DICOM Storage SCP Service DIMEX 4499 DICOM Storage SCU Service DIMEX Not applicable DICOM Worklist SCU Service DIMEX Not applicable REMOTE AE TITLE/PRESENTATION ADDRESS MAPPING The AE Title, host names and port numbers of remote applications can be configured in the configuration. All application entities that initiate associations must be configured together with the presentation address (TCP/IP address and port number) to be used in the configuration. This affects the following application entities: DICOM Storage SCU Service DICOM Worklist SCU Service The application entities accepting associations ignore the calling and the called application entity titles. This affects the following application entities: DICOM Storage SCP Service SECURITY SECURITY PROFILES Not supported. Page 11

ASSOCIATION LEVEL SECURITY Any calling application entity title may open an Association. APPLICATION LEVEL SECURITY The configuration console is password protected. ANNEXES PRIVATE TRANSFER SYNTAXES By default, no Private Transfer Syntaxes are supported Page 12