PRO DATA Srl. DICOM MODALITY WORKLIST SCU Conformance Statement (MicroPrint-modality-worklist-scu.sxw)

Similar documents
PRO DATA Srl. MicroPrint. DICOM STORE SCU Conformance Statement (MicroPrint-prnsrv-store-scu.sxw)

PRO DATA Srl. MicroPrint. DICOM PRINT SCU Conformance Statement (MicroPrint-prnsrv-print-scu.sxw)

dicom PACS DX-R Version 3.0

DICOM Conformance Statement

JiveX Enterprise PACS Solutions. JiveX DICOM Worklist Broker Conformance Statement - DICOM. Version: As of

SonoWin Picture Archiving System

DICOM Conformance Statement for PenFetch

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010

XPLORE GESTION SCP WORKLIST CONFORMANCE STATEMENT

DxServer for Windows NT DICOM 3.0 Conformance Statement. Document Reference (Référence du document): 00/ Dec28/ABA/MM100/410A

QCT PRO DICOM Conformance Statement

FUSION RIS 3.30 DICOM Conformance Statement

Matrix Server and Client DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement

Topcon Medical Systems

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

Digital Lightbox 1.0

Medical Imaging Consultants, Inc.

DICOM Conformance Statement. Fusion RIS Version 3.1

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

OASIS V4.0 DICOM Conformance Statement Rev. 3

Merge PACS TM v. 7.0 DICOM CONFORMANCE STATEMENT MODALITY WORKLIST. Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

Kodak Point of Care CR systems. DICOM Conformance Statement

DICOM Conformance Statement DragonflyPACS - Rev. 004 Page 3 / 33

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

Abstract. XrayVision DICOM Conformance Statement. Abstract Abstract

SwissVision TR4000. DICOM Conformance Statement Modality Performed Procedure Step (MPPS) Services. Program Version 9.3 or later Document Revision 1.

1 CONFORMANCE STATEMENT OVERVIEW

Application Launcher 2.2 DICOM Conformance Statement

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

SonoWin Picture Archiving System

DICOM Conformance Statement

DICOM Conformance Statement

DICOM 3.0 Conformance Statement DXIMAGE RIS

Surgimap. DICOM Conformance Statement. Revision 2.0

AVIA (Dx MM) DICOM 3.0 Conformance Statement

NumaLink-3.0 DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

dicom PACS 5 Version 5.2

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DICOM Conformance Statement

Philips Medical Systems DICOM Conformance Statement USIT 1.5

DICOM Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

WINRAD-32 Teleradiology System Conformance Claim

NumaStore 1.0 DICOM 3.0 Conformance Statement

Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

DICOM V3.0 Conformance Statement. SenoIris 1SP2

VM PACS DICOM Conformance Statement

TOSHIBA AMERICA MEDICAL SYSTEMS

Punctual Dicom Workstation

DICOM Conformance Statement. CharruaPACS

DICOM 3.0 Conformance Statement

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

nstream Version 3.1 DICOM Conformance Statement

HCP DICOM Net DICOM Conformance Statement

Philips Medical Systems DICOM Conformance Statement USIT 1.5 L3

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

DICOM Conformance Statement. Forum

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

DICOM 3.0 Conformance Statement

DICOM Conformance Statement for IMAGEnet 5

DICOM Conformance Statement

GE Healthcare. Technical Publications. ConnectR Plus Version 5.0 DICOM CONFORMANCE STATEMENT. GE Healthcare IT. Direction DOC Revision 0.

DICOM Conformance Statement FORUM

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0

HEALTHCARE DICOM Conformance Statement

DICOM Conformance Statement Product Name HCP DICOM Net Version

DICOM 3.0 Conformance Statement DICOMlink for DELTAmanager Send

AGFA HEALTHCARE DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

ETIAM Nexus. DICOM Conformance Statement.

Parascript AccuDetect CAD Software System

ASTERIS MDS. DICOM Conformance Statement. for. Asteris Modality Distribution System (MDS) Software. Last Document Update: July 22, 2008.

M517-E092C Feb Digital Radiography System SDR-150C. DICOM Conformance Statement

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT. BrainLAB PatXfer 5

DICOM Conformance Statement

No. MIIMS0002EAG TOSHIBA MEDICAL SYSTEMS CORPORATION ALL RIGHTS RESERVED

BRIT Systems. DICOM Conformance Statement

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

DICOM Conformance Statement FORUM

DICOM CONFORMANCE STATEMENT for Keratograph ( )

SIEMENS. DICOM Conformance Statement

DICOM Conformance Statement. EasyWeb 3.0. Document Number XZR January Copyright Philips Medical Systems Nederland B.V.

Sep, th Edition 897N101668H

DICOM Conformance Statement

Technical Publications

Whole Body X-ray CT System Supria. DICOM Conformance Statement

DICOM Conformance Statement

Privilege/Prestige. DICOM Conformance Statement. Version Algotec Systems Ltd.

Uscan. DICOM Conformance Statement

Transcription:

PRO DATA Srl MicroPrint DICOM MODALITY WORKLIST SCU Conformance Statement (MicroPrint-modality-worklist-scu.sxw) Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 1 / 11

TABLE OF CONTENTS 1 INTRODUCTION...3 1.1 Revision History...3 1.2 Abbreviations and Acronyms...3 1.3 Scope...4 2 IMPLEMENTATION MODEL...5 2.1 Application Data Flow Diagram...5 2.2 Functional Definitions of Aes...5 2.2.1 Modality Worklist SCU...5 3 AE SPECIFICATION...6 3.1 Modality Worklist SCU...6 3.1.1 Association Establishment Policies...6 3.1.1.1 General...6 3.1.1.2 Number of Associations...6 3.1.1.3 Asynchronous Nature...6 3.1.1.4 Implementation Identifying Information... 6 3.1.2 Association Initiation by Real-World Activity...6 3.1.2.1 Real-World Activity Modality Worklist QUERY...6 3.1.2.1.1 Proposed Presentation Context...6 3.1.2.1.1.1 SOP Specific Conformance for Storage SOP Classes... 7 3.1.3 Association Acceptance Policy...7 4 COMMUNICATION PROFILES...8 4.1 Supported Communication Stacks...8 4.2 OSI Stack...8 4.3 TCP/IP Stack...8 4.3.1 API...8 4.3.2 Physical Media Support...8 4.4 Point-to-Point Stack...8 5 EXTENSIONS/SPECIALIZATIONS/PRIVATIZATIONS...9 5.1 Standard Extended/Specialized/Private SOPs...9 5.2 Private Transfer Syntaxes...9 6 CONFIGURATION...10 6.1 AE Title / Presentation Address Mapping...10 6.2 Configurable Parameters...10 6.2.1 Modality Worklist SCU...10 7 SUPPORT OF EXTENDED CHARACTER SETS...11 Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 2 / 11

1 INTRODUCTION This DICOM conformance statement specifies the behavior and functionality of the MODALITY WORKLIST module of Microprint application. This software provides the following capabilities: 1. Acts as a dicom C-FIND Modality Worklist scu service to retrieve Patient Data 1.1 Revision History Version Date Author NOTE 1.0 19/10/2002 R.Ruggeri Initial release 1.2 Abbreviations and Acronyms ASCII American Standard Code for Information Interchange AE Application Entity ANSI American National Standards Institute CR Computed Radiography CT Computed Tomography DICOM Digital Imaging and Communications in Medicine ECR European Congress of Radiology GSPS Grayscale Softcopy Presentation State HIMSS Healthcare Information and Management Systems Society IE Information Entity IHE Integrating the Healthcare Enterprise IOD Information Object Definition ISO International Standards Organization NEMA National Electrical Manufacturers Association OSI Open Systems Interconnection PDU Protocol Data Unit RSNA Radiological Society of North America SCP Service Class Provider SCU Service Class User SOP Service Object Pair SR Structured Reporting TCP/IP Transmission Control Protocol / Internet Protocol TLS Transport Layer Security UID Unique Identifier VM Value Multiplicity VR Value Representation Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 3 / 11

1.3 Scope This DICOM Conformance Statement documents the conformance of the MODALITY WORKLIST software module of Microprint application with the Digital Imaging and Communications in Medicine (DICOM) standard. This document is essential in order to evaluate whether or not another DICOM compliant device can communicate with this software product. This statement is conformant with the recommended format as described in PS 3.2 of the DICOM standard Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 4 / 11

2 IMPLEMENTATION MODEL 2.1 Application Data Flow Diagram Microprint consists of an application which query Modality Worklist as a Service Class User (SCU). Modality Worklist SCU is activated by Microprint application when the user requests to query patient demographics data from a remote node. The application entity titles are freely configurable. Microprint C-FIND Remote Modality Worklist SCP DICOM Standard Interface Disegno 1Implementation Model 2.2 Functional Definitions of Aes 2.2.1 Modality Worklist SCU Modality Worklist SCU is an application entity that implements the DICOM Modality Worklist Service Class as SCU. Modality Worklist SCU is started when user requests to retrieve patient data from a remote node. This prevents the need to enter patient demographics manually. Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 5 / 11

3 AE SPECIFICATION 3.1 Modality Worklist SCU This application entity provides standard conformance to the following DICOM SOP classes as an SCU: SOP Class Name SOP Class UID Modality Worklist Information Model - FIND 1.2.840.10008.5.1.4.31 3.1.1 Association Establishment Policies 3.1.1.1 General The DICOM standard application context name, which is always proposed, is: Application context name 1.2.840.10008.3.1.1.1 The maximum PDU length can be configured at installation time in the range 4096..131072 bytes. The default is 16384 bytes. SOP Class extended negotiation is not supported. 3.1.1.2 Number of Associations Modality Worklist SCU will only propose a single association. 3.1.1.3 Asynchronous Nature Asynchronous mode of operation is not supported. 3.1.1.4 Implementation Identifying Information The implementation UID of this application is: OFFIS DCMTK 3.5.1 Implementation Class UID 1.2.276.0.7230010.3.0.3.5.1 3.1.2 Association Initiation by Real-World Activity 3.1.2.1 Real-World Activity Modality Worklist QUERY Microprint opens an Association with remote Worklist SCP for the purpose of querying for a Modality Worklist. Microprint sends an C-FIND query to remote server. It queries its database using the attributes from the C-FIND Request and returns 0 to N C-FIND responses depending on matches returned from the database. Worklist SCP sends the final C-FIND response then Microprint closes the Association. 3.1.2.1.1 Proposed Presentation Context The default behavior of the Modality Worklist SCU is to propose as SCU for each of the supported SOP classes a single presentation context containing one or more of the following transfer syntaxes: Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 6 / 11

Implicit VR Little Endian 1.2.840.10008.1.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 Explicit VR Big Endian 1.2.840.10008.1.2.2. 3.1.2.1.1.1 SOP Specific Conformance for Storage SOP Classes FIND-SCU provides standard conformance to the supported C-FIND SOP Classes. Only a single information model, Study Root, is supported. All queries are initiated at the highest level of the information model (the STUDY level), and then for each response received, recursively repeated at the next lower levels (the SERIES and then IMAGE levels), in order to completely elucidate the tree of instances available on the remote AE (from which the user may subsequently request a retrieval at any level). No CANCEL requests are ever issued. Unexpected attributes returned in a C-FIND response (those not requested) are listed in the browser at the appropriate level if present in the dictionary. Requested return attributes not returned by the SCP are ignored. Non-matching responses returned by the SCP due to unsupported (hopefully optional) matching keys are not filtered locally by the FIND-SCU and thus will still be presented in the browser. No attempt is made to filter out duplicate responses. Specific Character Set will always be included at every query level. If present in the response, Specific Character Set will be used to identify character sets other than the default character set for display of strings in the browser. 3.1.3 Association Acceptance Policy This application entity never accepts associations. Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 7 / 11

4 COMMUNICATION PROFILES 4.1 Supported Communication Stacks DICOM Upper Layer over TCP/IP is supported. 4.2 OSI Stack Not supported. 4.3 TCP/IP Stack The TCP/IP stack is inherited from the underlying operating system 4.3.1 API The application makes use of the WinSock interface on Win32 platforms. 4.3.2 Physical Media Support DICOM is indifferent to the physical medium over which TCP/IP executes. 4.4 Point-to-Point Stack Not supported. Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 8 / 11

5 EXTENSIONS/SPECIALIZATIONS/PRIVATIZATIONS 5.1 Standard Extended/Specialized/Private SOPs Not supported or negotiated. 5.2 Private Transfer Syntaxes Not supported or negotiated. Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 9 / 11

6 CONFIGURATION 6.1 AE Title / Presentation Address Mapping The mapping of application entity titles to presentation addresses is configurable in the configuration file, see details below. 6.2 Configurable Parameters 6.2.1 Modality Worklist SCU For the Modality Worklist SCU component, the following parameters are configurable for each send target: Presentation address (DNS hostname or IP address) IP port number Called application entity title Calling application entity title Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 10 / 11

7 SUPPORT OF EXTENDED CHARACTER SETS This application supports only ISO_IR 100 (ISO 8859-1 Latin 1) as extended character set. Microprint - DICOM MODALITY WORKLIST SCU Conformance Statement Pag 11 / 11