Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Technical data sheet. Technical data

Power consumption In operation At rest For wire sizing

Technical data. Safety notes. Product features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

Functional data Factory settings Variable Setting Torque Inhibiting torque

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

s Spring return C / max C

Technical data sheets

Belimo Gateway MP to Modbus RTU - UK24MOD

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Belimo Gateway MP to Modbus RTU - UK24MOD

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Overview of types. Technical data

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Brief description. Type overview

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Products no longer available

VAV system solution for non-pressure dependent applications in enclosed spaces

Products no longer available

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Technical data sheet

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Air Damper Actuators Modbus RTU

Installation VAV-Compact Retrofit Set

VAV Compact Controller Modbus RTU

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

BUS. Adaptive control system for pressure applications (STP) Table of contents

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Air Damper Actuators Modbus RTU

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Product information. Technical data. Safety notes. Definitions

InReg Volume flow controller Pa

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

ZN230-24MP-1 MP-BUS

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

VAV compact controller KNX / PL-Link

Products no longer available

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

Belimo Gateway MP to BACnet MS/TP - UK24BAC

VAV compact controller GDB181.1E/3 GLB181.1E/3

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Modbus TCP/RTU MP-Bus converter

Belimo Gateway MP to LONWORKS - UK24LON

Rotary version, three-position control

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VAV compact controller

Universal Controller

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Actuators for CAV control lers

Non-communicating room controllers

Products no longer available

Compact Universal Controllers

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

InCos-P Pressure sensor 20 Pa Pa

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Handheld Tool for VAV compact and modular controllers

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Product information. Technical data. Safety notes. Definitions

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Zelio Control-modular measurement and control relays 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

Air damper actuators

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

LLR-MOD Modbus Light Level and Occupancy Sensor

Rotary actuator for ball valves KNX / PL-Link

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

ASI Systems ML5740A Series

Super universal modules

Transcription:

echnical data sheet LM24A-MOD Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 1 m² Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals Communication via Modbus RU (RS-485) echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 2.5 W Power consumption in rest position 1.3 W Power consumption for wire sizing 5 VA Connection supply / control Cable 1 m, 6 x 0.75 mm² Data bus communication Protocol Modbus RU (RS-485), not galvanically isolated Number of nodes Max. 32 (without repeater) ransmission formats 1-8-N-2, 1-8-N-1, 1-8-E-1, 1-8-O-1 Default: 1-8-N-2 (start bits, data bits, parity, stop bits) Baud rate 9600, 19,200, 38,400, 76,800, 115,200 Bd Default: 38,400 Bd erminating resistor 120 Ohm, can be switched Parameterisation with service tool ZH EU Pushbutton-operated fast addressing 1... 16 possible Functional data orque motor Min. 5 Nm orque variable 25%, 50%, 75% reduced Position accuracy ±5% Direction of motion motor selectable with switch 0 / 1 Direction of motion note Y = 0%: At switch position 0 for ccw rotation or 1 for cw rotation, respectively Direction of motion variable electronically reversible Manual override with push-button, can be locked Angle of rotation Max. 95 Angle of rotation note can be limited on both sides with adjustable mechanical end stops Running time motor 150 s / 90 Motor running time variable 35...150 s Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control, controllable via Modbus MAX (maximum position) = 100% MIN (minimum position) = 0% ZS (intermediate position) = 50% Override control variable MAX = (MIN + 32%)...100% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level motor 35 db(a) Spindle driver Universal spindle clamp 6...20 mm Position indication Mechanically, pluggable Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class UL UL Class 2 Supply Degree of protection IEC/EN IP54 Degree of protection NEMA/UL NEMA 2, UL Enclosure ype 2 www.belimo.com LM24A-MOD en-gb 2017-08-31 subject to changes 1

echnical data Safety EMC CE according to 2014/30/EU Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14 Certification UL culus according to UL 60730-1A, UL 60730-2- 14 and CAN/CSA E60730-1:02 Mode of operation ype 1 Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 0.65 kg Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Manual override Adjustable angle of rotation High functional reliability he actuator is fitted with an integrated interface for Modbus RU, it receives the digital positioning signal from the Modbus-Master and returns the current status. Connection option for a sensor (passive or active sensor or switching contact). In this way, the analogue sensor signal can be easily digitised and transferred to Modbus. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH EU. he Modbus communication parameters (address, baud rate etc.) are set with the ZH EU. Pressing push-button Address on the actuator while connecting the supply voltage resets the communication parameters to the factory setting. Quick addressing: he Modbus address can alternatively be set using push-buttons on the actuator from 1 to 16. he value selected is added to the «Basic address» parameter and results in the effective Modbus address. For example, with a basic address of 140, Modbus addresses between 141 and 156 can be parameterised using quick addressing. Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). Adjustable angle of rotation with mechanical end stops. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. 2 LM24A-MOD en-gb 2017-08-31 subject to changes www.belimo.com

Product features Home position he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. 0 Y = 0% ccw 1 Y = 0% cw Adaption and synchronisation An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after pressing the gearbox disengagement button is configured. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) Accessories Description Electrical accessories Auxiliary switch, add-on, 1 x SPD S1A Auxiliary switch, add-on, 2 x SPD S2A Feedback potentiometer 140 Ohm, add-on P140A Feedback potentiometer 140 Ohm, add-on, grey P140A GR Feedback potentiometer 200 Ohm, add-on P200A Feedback potentiometer 500 Ohm, add-on P500A Feedback potentiometer 500 Ohm, add-on, grey P500A GR Feedback potentiometer 1 kohm, add-on P1000A Feedback potentiometer 1 kohm, add-on, grey P1000A GR Feedback potentiometer 2.8 kohm, add-on P2800A Feedback potentiometer 2.8 kohm, add-on, grey P2800A GR Feedback potentiometer 5 kohm, add-on P5000A Feedback potentiometer 5 kohm, add-on, grey P5000A GR Feedback potentiometer 10 kohm, add-on P10000A Feedback potentiometer 10 kohm, add-on, grey P10000A GR Connection cable 5 m, A+B: RJ12 6/6, o ZH/ZIP-USB-MP ZK1-GEN Connection cable 5 m, A: RJ11 6/4, B: Free wire end, o ZH/ZIP- USB-MP ZK2-GEN Description Mechanical accessories Shaft extension 170 mm, for damper spindles Ø 6...20 mm AV6-20 Spindle clamp for LM..A, clamping range 6...20 mm K-ELA Spindle clamp for LM..A, clamping range 6...10 mm K-ELA10 Spindle clamp for LM..A, clamping range 6...13 mm K-ELA13 Spindle clamp for LM..A, clamping range 6...16 mm K-ELA16 Universal mounting bracket 180 mm Z-ARS180 Form fit insert 8x8 mm, for LM..A ZF8-LMA Form fit insert 10x10 mm, for LM..A ZF10-LMA Form fit insert 12x12 mm, for LM..A ZF12-LMA Form fit insert 8x8 mm, with angle of rotation limiter and position ZFRL8-LMA indication for LM..A Form fit insert 10x10 mm, with angle of rotation limiter and position ZFRL10-LMA indication for LM..A Form fit insert 12x12 mm, with angle of rotation limiter and position ZFRL12-LMA indication for LM..A Position indication for LM..A, NM..A, SM..A, GM..A Z-PI ype ype www.belimo.com LM24A-MOD en-gb 2017-08-31 subject to changes 3

Accessories Description Service ools Service tool for parametrisable and communicative Belimo actuators / VAV controller and HVAC performance devices Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH EU MF-P MF-C Electrical installation! Wiring diagrams Modbus wiring GND D D + Master Notes Connection via safety isolating transformer. he wiring of Modbus RU (RS485) is to be carried out in accordance with applicable regulations (www.modbus.org). he device has switchable resistors for bus termination. Modbus-GND: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. Modbus (RS-485) 1 2 3 5 6 7 1 2 3 5 6 7 + AC/DC 24 V MF D D+ MF D D+ + AC/DC 24 V Slave 1 Slave 32 Connection with passive sensor, e.g. Pt1000, Ni1000, NC + D D + Modbus (RS-485) 1 2 3 5 6 7 Ni1000 28...+98 C 850...1600 Ω 2) MF D D+ P1000 35...+155 C 850...1600 Ω 2) NC 10...+160 C 1) 200 Ω...60 kω 2) 1) depending on type 2) Resolution 1 Ohm Connection with switching contact, e.g. pressure control device p + D D + Modbus (RS-485) 1 2 3 5 6 7 MF D D+ Requirements for switching contact: he switching contact must be able to accurately switch a current of 16 ma @ 24 V. 4 LM24A-MOD en-gb 2017-08-31 subject to changes www.belimo.com

Electrical installation Connection with active sensor, e.g. 0...10 V @ 0...50 C + D D + Modbus (RS-485) 1 2 3 5 6 7 MF D D+ Possible voltage range: 0...32 V (resolution 30 mv) www.belimo.com LM24A-MOD en-gb 2017-08-31 subject to changes 5

Modbus communication parameters Register No. Adr Register 1 0 Setpoint [%] 2 1 Override control 3 2 Command 4 3 Actuator type 5 4 Relative position [%] 6 5 Absolute position [ ] [mm] 7 6 Relative volumetric flow [%] (only for VAV/EPIV) 8 7 Absolute volumetric flow (pressure) [m 3 /h] [l/min] [Pa] (only for VAV/EPIV) 9 8 Sensor value [mv] [Ω] [ ] 101 100 Series number 1st part 102 101 Series number 2nd part 103 102 Series number 4th part 104 103 Firmware version (Modbus module) 105 104 Malfunction and service information 106 105 Min [%] 107 106 Max [%] 108 107 Sensor type 109 108 Bus fail position 110 109-111 110 Nominal volumetric flow (pressure) [m3/h] [l/min] [Pa] (only for VAV/EPIV) In operation Service Registers in Bold can be written Registers <100 (In operation) which can be written are volatile and should therefore be updated periodically Registers >100 which can be written are non-volatile Commands Note regarding Read Discrete Inputs he command reads one or more bits and can alternatively be used for register 105 (Malfunction and service information). he start address to be used is 1664. All data is arranged in a table and addressed by 1..n (register) or 0..n-1 (address). No distinction is made between data types (Discrete Inputs, Coils, Input Registers, Holding Registers). As a consequence, all data can be accessed with the two commands for Holding Register. he commands for Discrete Inputs and Input Registers can be used as an alternative. Standard commands: Read Holding Registers [3] Write Single Register [6] Optional commands: Read Discrete Inputs [2] Read Input Registers [4] Write Multiple Registers [16] 6 LM24A-MOD en-gb 2017-08-31 subject to changes www.belimo.com

Modbus communication parameters Register 1: Setpoint Register 2: Override control Register 3: Command Register 4: Actuator type Register 5: Relative position Register 6: Absolute position Register 7: Relative volumetric flow Register 8: Absolute volumetric flow Setpoint for actuator setting or volumetric fl ow in hundredths of one percent, i.e. 0 10 000 corresponds to 0 100% Overriding the setpoint with defined values Override control 0 None 1 Open 2 Close 3 Min 5 Max Initiation of actuator functions for service and test; the register is reset automatically. Command 0 None 1 Adaption 2 est run 3 Synchronisation 4 Reset actuator malfunctions Actuator type; the allocation may deviate from the basic category with some actuators. Actuator type 0 Actuator not connected / not known 1 Air/water actuators with/without safety function 2 Volumetric flow controller VAV / EPIV 3 Fire damper actuator Relative position in hundredths of one percent, i.e. 0 10 000 correspond to 0 100% Absolute position 0 10 000 (65535 if not supported by the actuator) he unit depends on the device: [ ] for actuators with rotary movement [mm] for actuators with linear movement Relative volumetric fl ow in hundredths of one percent of Vnom, i.e. 0 10 000 correspond to 0 100% his value is available only for VAV controllers and EPIV devices (actuator type: 2). For all other types, 65535 will be entered. Absolute volumetric fl ow his value is available only for VAV controllers and EPIV devices (actuator type: 2). For all other types, 65535 will be entered. he unit depends on the device: [m 3 /h] for VAV controllers (or [Pa] for pressure applications) [l/min] for EPIV devices Register 9: Sensor value Current sensor value; dependent on the setting in Register 108 he unit depends on the sensor type: [mv] [Ω] [-] Register 101-103: Series number Register 104: Firmware Version Each device has an unambiguous series number which is either impr essed on or glued to the housing. he series number consists of 4 segments, although only parts 1, 2 and 4 are displayed on Modbus. Example: 00839-31324-064-008 Register 101 Register 102 Register 103 1st part 2nd part 4th part 00839 31234 008 Firmware version of Modbus module (VX.XX) e.g. 101 V1.01 www.belimo.com LM24A-MOD en-gb 2017-08-31 subject to changes 7

Modbus communication parameters Register 105: Malfunction and service information he status information is split into messages about the actuator (malfunctions) and other service information. Malfunctions (low byte) Service (high byte) Bit Description 0 Excessive utilisation 1 Mechanical travel increased 2 Mechanical overload 3 4 Safety-relevant faults (fire protection only) 5 Damper test error (fire protection only) 6 Duct temperature too high (fire protection only) 7 Smoke detector tripped (fire protection only) 8 Internal activity (test run, adaption, ) 9 Gear disengagement active 10 Bus watchdog triggered 11 12 13 14 15 he malfunction bits can be reset with Register 3 (command 4) or with the Belimo PC-ool. Malfunctions 0 and 4 cannot be reset. Register 106: Min / Vmin setting Register 107: Max / Vmax setting Register 108: Sensor type Notes After changing the sensor type, the actuator must always be restarted in order for correct sensor values to be read out. By using actuator variants with RJ12 sockets (J6) sensor values are not available, as connecting a sensor is not possible. Register 109: Bus fail position Register 110: (Reserved) Register 111: Nominal volumetric flow Minimum limit (position or volumetric flow) in hundredths of one percent, i.e. 0 10 000 correspond to 0 100% Caution: Changing the setting may result in malfunctions. Maximum limit (position or volumetric flow) in hundredths of one percent, i.e. 2000 10 000 correspond to 20 100% Caution: Changing the setting may result in malfunctions. Sensor type connected to the actuator; in the absence of sensor specification, the switching at the Y input will have the effect of a local compulsion. Sensor type 0 None 1 Active sensor (mv) 2 Passive sensor 1 k (Ω) 3 Passive sensor 1 20 k (Ω) 4 Switching contact (0 / 1) Modbus communication is not monitored as standard. In the event of a breakdown in communication, the actuator retains the current setpoint. he bus monitoring controls the Modbus communication. If neither the setpoint (Register 1) nor the override control (Register 2) is renewed within 120 seconds, the actuator controls to the bus fail position. riggered bus monitoring is indicated in Register 105. Bus fail position 0 Last setpoint (no bus monitoring) 1 Fast close if time is exceeded 2 Fast open if time is exceeded 3 Parameterized intermediate position Mid if time is exceeded Not used in this device. his value is available only for VAV controllers and EPIV devices (actuator type: 2). For all other types, 65535 will be entered. he unit depends on the device: [m3/h] for VAV controllers (or [Pa] for pressure applications) [l/min] for EPIV devices 8 LM24A-MOD en-gb 2017-08-31 subject to changes www.belimo.com

Operating controls and indicators 4 1 Adaption Address 0 1 2 Power 3 Status 1 Direction of rotation switch Switch over: Direction of rotation changes 2 Push-button and LED display green Off: No power supply or malfunction On: In operation Flashing: In address mode: Pulses according to set address (1...16) When starting: Reset to factory setting (Communication) Press button: In standard mode: riggers angle of rotation adaptation In address mode: Confirmation of set address (1...16) 5 3 Push-button and LED display yellow Off: On: Flickering: Press button: Standard mode Adaptation or synchronising process active or actuator in address mode (LED display green flashing) Modbus communication active In operation (>3 s): Switch address mode on and off In address mode: Address setting by pressing several times When starting (>5 s): Reset to factory setting (Communication) 4 Gear disengagement button Press button: Gear disengages, motor stops, manual override possible Release button: Gear engages, synchronisation starts, followed by standard mode 5 Service plug For connecting parameterisation and service tools Check power supply connection 2 Off and 3 On Possible wiring error in power supply Service Quick adressing Modbus Service ools connection 1. Press the Address button until the green Power LED is no longer illuminated. he green Adaption LED flashes in accordance with the previously set address. 2. Set the address by pressing the Address button the corresponding number of times (1-16). 3. he green LED flashes in accordance with address that has been entered (1-16). If the address is not correct, then this can be reset in accordance with Step 2. 4. Confirm the address setting by pressing the green Adaption button. If no confirmation occurs for 60 seconds, then the address procedure is ended. Any address change that has been made will be discarded. he resulting Modbus address is made up of the set basic address plus the short address (e.g. 140+7=147). he actuator can be parameterised by ZH EU via the service socket. For an extended parameterisation the PC tool can be connected. + AC 24 V DC 24 V 1 2 3 5 6 7 MP USB ZH EU i esc OK BELIMO PC-ool MF D D+ USB www.belimo.com LM24A-MOD en-gb 2017-08-31 subject to changes 9

Dimensions [mm] Spindle length Dimensional drawings L Min. 37 6...20 6 20-66 47 116 61 22 116 41 Further documentation ool connections 10 LM24A-MOD en-gb 2017-08-31 subject to changes www.belimo.com